Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 7/2022

05-02-2022 | Angiography | Original Paper

Diagnostic agreement of quantitative flow ratio with fractional flow reserve in a Latin-American population

Authors: Mauro Echavarría-Pinto, Tim P. Van de Hoef, Nancy Pacheco-Beltran, Jesus Eduardo Reyes-Carrera, Eduardo Rangel-Alvarado, Elizabeth Ledezma-Ledezma, Laura Alicia Aguilar-Castillo, Andrea Itzel Tovar-Becerra, Juan Ernesto Muñoz Arellano, María Neftalí Maqueda Ramírez, Miriam Muruaga, Ana Maria Ibarra-Rangel, Carlos Alberto Montes-Collantes, Jorge Luis Castrejon-Mora, Irma Hualtal Chong-Benitez, Luis Homero Vargas-Torrrescano, Hector M. García-García

Published in: The International Journal of Cardiovascular Imaging | Issue 7/2022

Login to get access

Abstract

Quantitative flow ratio (QFR) is a recently proposed angiographic index that allows to assess the pressure loss in coronary arteries in a similar fashion as the fractional flow reserve (FFR). The purpose of this study was to evaluate the diagnostic performance of QFR as compared to FFR, in a Latin-American population of patients with suspected ischaemic heart disease. QFR was retrospectively derived from coronary angiograms. The association, diagnostic performance, and continuous agreement of fixed-flow QFR (fQFR) and contrast-flow QFR (cQFR) with FFR was assessed by continuous and dichotomous methods. 90 vessels form 66 patients were finally included. The study comprised coronary stenoses of intermediate severity, both angiographically (diameter stenosis: 46.6 ± 12.8%) and physiologically [median FFR = 0.83 (quartile 1–3, 0.76–0.89)]. The correlation of FFR with both fQFR [ρ = 0.841, (95% CI 0.767 to 0.893), p < 0.001] and cQFR [ρ = 0.833, (95% CI 0.755 to 0.887), p < 0.001] was strong. The diagnostic performance of cQFR was good [area under the ROC curve of 0.92 (95% CI 0.86 to 0.97, p < 0.001)], with 0.80 as the optimal cQFR cut-off against FFR ≤ 0.80. This 0.80 cQFR cut-off classified correctly 83.3% of total stenoses, with a sensitivity of 85.2% and specificity of 80.6%. QFR was strongly associated with FFR and exhibited a high diagnostic performance in this Latin-American population.
Literature
1.
go back to reference Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, Prescott E, Storey RF, Deaton C, Cuisset T, Agewall S, Dickstein K, Edvardsen T, Escaned J, Gersh BJ, Svitil P, Gilard M, Hasdai D, Hatala R, Mahfoud F, Masip J, Muneretto C, Valgimigli M, Achenbach S, Bax JJ, ESC Scientific Document Group (2020) 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 41:407–477CrossRefPubMed Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, Prescott E, Storey RF, Deaton C, Cuisset T, Agewall S, Dickstein K, Edvardsen T, Escaned J, Gersh BJ, Svitil P, Gilard M, Hasdai D, Hatala R, Mahfoud F, Masip J, Muneretto C, Valgimigli M, Achenbach S, Bax JJ, ESC Scientific Document Group (2020) 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 41:407–477CrossRefPubMed
2.
go back to reference van de Hoef TP, Lee JM, Echavarria-Pinto M, Koo B-K, Matsuo H, Patel MR, Davies JE, Escaned J, Piek JJ (2020) Non-hyperaemic coronary pressure measurements to guide coronary interventions. Nat Rev Cardiol 17:629–640CrossRefPubMed van de Hoef TP, Lee JM, Echavarria-Pinto M, Koo B-K, Matsuo H, Patel MR, Davies JE, Escaned J, Piek JJ (2020) Non-hyperaemic coronary pressure measurements to guide coronary interventions. Nat Rev Cardiol 17:629–640CrossRefPubMed
3.
go back to reference Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, Nef H, Tebaldi M, Murasato Y, Lansky A, Barbato E, van der Heijden LC, Reiber JHC, Holm NR, Wijns W, FAVOR Pilot Trial Study Group (2016) Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR Pilot study. JACC Cardiovasc Interv 9:2024–2035CrossRefPubMed Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, Nef H, Tebaldi M, Murasato Y, Lansky A, Barbato E, van der Heijden LC, Reiber JHC, Holm NR, Wijns W, FAVOR Pilot Trial Study Group (2016) Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR Pilot study. JACC Cardiovasc Interv 9:2024–2035CrossRefPubMed
4.
go back to reference Duarte A, Llewellyn A, Walker R, Schmitt L, Wright K, Walker S, Rothery C, Simmonds M (2021) Non-invasive imaging software to assess the functional significance of coronary stenoses: a systematic review and economic evaluation. Health Technol Assess Winch Engl 25:1–230CrossRef Duarte A, Llewellyn A, Walker R, Schmitt L, Wright K, Walker S, Rothery C, Simmonds M (2021) Non-invasive imaging software to assess the functional significance of coronary stenoses: a systematic review and economic evaluation. Health Technol Assess Winch Engl 25:1–230CrossRef
6.
go back to reference Fuensalida A, Vergara F, Hameau R, Quitral J, Sepúlveda P, Martínez A, Valenzuela E, Martínez G (2021) Evaluación no invasiva de la significancia funcional de las lesiones coronarias mediante Quantitative Flow Ratio (QFR). Validación con Reserva de Flujo Fraccional (FFR). Rev Chil Cardiol 40:96–103CrossRef Fuensalida A, Vergara F, Hameau R, Quitral J, Sepúlveda P, Martínez A, Valenzuela E, Martínez G (2021) Evaluación no invasiva de la significancia funcional de las lesiones coronarias mediante Quantitative Flow Ratio (QFR). Validación con Reserva de Flujo Fraccional (FFR). Rev Chil Cardiol 40:96–103CrossRef
7.
go back to reference Escaned J, Echavarría-Pinto M, Garcia-Garcia HM, van de Hoef TP, de Vries T, Kaul P, Raveendran G, Altman JD, Kurz HI, Brechtken J, Tulli M, Von Birgelen C, Schneider JE, Khashaba AA, Jeremias A, Baucum J, Moreno R, Meuwissen M, Mishkel G, van Geuns R-J, Levite H, Lopez-Palop R, Mayhew M, Serruys PW, Samady H, Piek JJ, Lerman A, ADVISE II Study Group (2015) Prospective assessment of the diagnostic accuracy of instantaneous wave-free ratio to assess coronary stenosis relevance: results of ADVISE II international, multicenter study (ADenosine Vasodilator Independent Stenosis Evaluation II). JACC Cardiovasc Interv 8:824–833CrossRefPubMed Escaned J, Echavarría-Pinto M, Garcia-Garcia HM, van de Hoef TP, de Vries T, Kaul P, Raveendran G, Altman JD, Kurz HI, Brechtken J, Tulli M, Von Birgelen C, Schneider JE, Khashaba AA, Jeremias A, Baucum J, Moreno R, Meuwissen M, Mishkel G, van Geuns R-J, Levite H, Lopez-Palop R, Mayhew M, Serruys PW, Samady H, Piek JJ, Lerman A, ADVISE II Study Group (2015) Prospective assessment of the diagnostic accuracy of instantaneous wave-free ratio to assess coronary stenosis relevance: results of ADVISE II international, multicenter study (ADenosine Vasodilator Independent Stenosis Evaluation II). JACC Cardiovasc Interv 8:824–833CrossRefPubMed
8.
go back to reference Xu B, Tu S, Song L, Jin Z, Yu B, Fu G, Zhou Y, Wang J, Chen Y, Pu J, Chen L, Qu X, Yang J, Liu X, Guo L, Shen C, Zhang Y, Zhang Q, Pan H, Fu X, Liu J, Zhao Y, Escaned J, Wang Y, Fearon WF, Dou K, Kirtane AJ, Wu Y, Serruys PW, Yang W, Wijns W, Guan C, Leon MB, Qiao S, Stone GW, FAVOR III China study group (2021) Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial. Lancet Lond Engl 398(10317):2149–2159CrossRef Xu B, Tu S, Song L, Jin Z, Yu B, Fu G, Zhou Y, Wang J, Chen Y, Pu J, Chen L, Qu X, Yang J, Liu X, Guo L, Shen C, Zhang Y, Zhang Q, Pan H, Fu X, Liu J, Zhao Y, Escaned J, Wang Y, Fearon WF, Dou K, Kirtane AJ, Wu Y, Serruys PW, Yang W, Wijns W, Guan C, Leon MB, Qiao S, Stone GW, FAVOR III China study group (2021) Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial. Lancet Lond Engl 398(10317):2149–2159CrossRef
9.
go back to reference Buderer NM (1996) Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity. Acad Emerg Med Off J Soc Acad Emerg Med 3:895–900CrossRef Buderer NM (1996) Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity. Acad Emerg Med Off J Soc Acad Emerg Med 3:895–900CrossRef
10.
go back to reference Zimmermann FM, Omerovic E, Fournier S, Kelbæk H, Johnson NP, Rothenbühler M, Xaplanteris P, Abdel-Wahab M, Barbato E, Høfsten DE, Tonino PAL, Boxma-de Klerk BM, Fearon WF, Køber L, Smits PC, De Bruyne B, Pijls NHJ, Jüni P, Engstrøm T (2019) Fractional flow reserve-guided percutaneous coronary intervention vs medical therapy for patients with stable coronary lesions: meta-analysis of individual patient data. Eur Heart J 40:180–186CrossRefPubMed Zimmermann FM, Omerovic E, Fournier S, Kelbæk H, Johnson NP, Rothenbühler M, Xaplanteris P, Abdel-Wahab M, Barbato E, Høfsten DE, Tonino PAL, Boxma-de Klerk BM, Fearon WF, Køber L, Smits PC, De Bruyne B, Pijls NHJ, Jüni P, Engstrøm T (2019) Fractional flow reserve-guided percutaneous coronary intervention vs medical therapy for patients with stable coronary lesions: meta-analysis of individual patient data. Eur Heart J 40:180–186CrossRefPubMed
11.
go back to reference Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR (2018) diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II europe-japan study. J Am Heart Assoc 7:e009603CrossRefPubMedPubMedCentral Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR (2018) diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II europe-japan study. J Am Heart Assoc 7:e009603CrossRefPubMedPubMedCentral
12.
go back to reference Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, Guo L, Sun Z, Li Z, Tian F, Fang W, Chen J, Li W, Guan C, Holm NR, Wijns W, Hu S (2017) Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol 70:3077–3087CrossRefPubMed Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, Guo L, Sun Z, Li Z, Tian F, Fang W, Chen J, Li W, Guan C, Holm NR, Wijns W, Hu S (2017) Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol 70:3077–3087CrossRefPubMed
Metadata
Title
Diagnostic agreement of quantitative flow ratio with fractional flow reserve in a Latin-American population
Authors
Mauro Echavarría-Pinto
Tim P. Van de Hoef
Nancy Pacheco-Beltran
Jesus Eduardo Reyes-Carrera
Eduardo Rangel-Alvarado
Elizabeth Ledezma-Ledezma
Laura Alicia Aguilar-Castillo
Andrea Itzel Tovar-Becerra
Juan Ernesto Muñoz Arellano
María Neftalí Maqueda Ramírez
Miriam Muruaga
Ana Maria Ibarra-Rangel
Carlos Alberto Montes-Collantes
Jorge Luis Castrejon-Mora
Irma Hualtal Chong-Benitez
Luis Homero Vargas-Torrrescano
Hector M. García-García
Publication date
05-02-2022
Publisher
Springer Netherlands
Keyword
Angiography
Published in
The International Journal of Cardiovascular Imaging / Issue 7/2022
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-022-02547-6

Other articles of this Issue 7/2022

The International Journal of Cardiovascular Imaging 7/2022 Go to the issue