Published in: The International Journal of Cardiovascular Imaging 9/2016

01-09-2016 | Original Paper

Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera

Authors: Vladimír Kincl, Milan Kamínek, Jiří Vašina, Roman Panovský, Martin Havel

Published in: The International Journal of Cardiovascular Imaging | Issue 9/2016

Login to get access

Abstract

High efficiency cadmium–zinc–telluride (CZT) cameras provide an opportunity to lower the injected activities of radiopharmaceuticals for single photon emission tomography (SPECT) myocardial perfusion imaging (MPI). The limits for reducing activities of thallium have not been determined, particularly in obese patients. After an injection of 0.7 megabecquerel (MBq) of thallium/kg, we collected an average 1.5 million counts for the 10-min acquisition in a pilot cohort of ten patients. After extrapolation, we reduced the administered activity to 0.5 MBq/kg to obtain the expected 1 million counts. We studied the image quality in 124 patients (86 men, 43 obese with body mass index over 30 kg/m2) referred for MPI. The quality of images was assessed by a number of recorded counts and visually by a four-grade scale (one-poor quality, four-excellent quality). In non-obese and obese patients, the average number of recorded counts was 1.1 vs. 1.07 million counts for the 10-min stress acquisition, 1.04 vs. 1.06 million counts for the 13-min rest acquisition, and the average quality score was 3.97 vs. 3.90, respectively (p = NS).The mean administered activity was 39.2 ± 7 MBq for non-obese and 48.7 ± 6 for obese patients (p < 0.0001), and the calculated effective dose was 4.0 ± 0.7 and 4.9 ± 0.6 mSv respectively (p < 0.0001). The ultra-low-dose thallium stress-redistribution protocol, including post-stress prone imaging, provides good quality of images with a low radiation burden, even in obese patients.
Literature
1.
go back to reference Slomka PJ, Patton JA, Berman DS, Germano G (2009) Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 16:255–276CrossRefPubMed Slomka PJ, Patton JA, Berman DS, Germano G (2009) Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 16:255–276CrossRefPubMed
2.
go back to reference Imbert L, Poussier S, Franken PR et al (2012) Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med 53:1897–1903CrossRefPubMed Imbert L, Poussier S, Franken PR et al (2012) Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med 53:1897–1903CrossRefPubMed
3.
go back to reference Nakazato R, Berman DS, Hayes SW et al (2013) Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol. J Nucl Med 54(3):373–379CrossRefPubMedPubMedCentral Nakazato R, Berman DS, Hayes SW et al (2013) Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol. J Nucl Med 54(3):373–379CrossRefPubMedPubMedCentral
4.
go back to reference Songy B, Guernou M, Lussato D, Queneau M, Geronazzo R (2012) Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera. Nucl Med Commun 33(5):464–469CrossRefPubMed Songy B, Guernou M, Lussato D, Queneau M, Geronazzo R (2012) Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera. Nucl Med Commun 33(5):464–469CrossRefPubMed
5.
go back to reference Tanaka H, Chikamori T, Tanaka N et al (2014) Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve. Circ J 78(11):2727–2734CrossRefPubMed Tanaka H, Chikamori T, Tanaka N et al (2014) Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve. Circ J 78(11):2727–2734CrossRefPubMed
6.
go back to reference Verberne HJ, Acampa W, Anagnostopoulos C et al (2015) EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 42:1929–1940CrossRefPubMedPubMedCentral Verberne HJ, Acampa W, Anagnostopoulos C et al (2015) EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 42:1929–1940CrossRefPubMedPubMedCentral
7.
go back to reference Sharir T, Pinskiy M, Pardes A et al (2016) Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: automated quantification of one-day, stress-first SPECT using a CZT camera. J Nucl Cardiol 23(1):11–20CrossRefPubMed Sharir T, Pinskiy M, Pardes A et al (2016) Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: automated quantification of one-day, stress-first SPECT using a CZT camera. J Nucl Cardiol 23(1):11–20CrossRefPubMed
8.
go back to reference Askew JW, Miller TD, Ruter RL et al (2011) Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging. J Nucl Cardiol 18:840–846CrossRefPubMed Askew JW, Miller TD, Ruter RL et al (2011) Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging. J Nucl Cardiol 18:840–846CrossRefPubMed
9.
go back to reference Esteves FP, Raggi P, Folks RD et al (2009) Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol 16:927–934CrossRefPubMedPubMedCentral Esteves FP, Raggi P, Folks RD et al (2009) Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol 16:927–934CrossRefPubMedPubMedCentral
10.
go back to reference Herzog BA, Buechel RR, Katz R et al (2010) Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med 51:46–51CrossRefPubMed Herzog BA, Buechel RR, Katz R et al (2010) Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med 51:46–51CrossRefPubMed
11.
go back to reference Buechel RR, Herzog BA, Husmann L et al (2010) Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging 37:773–778CrossRefPubMed Buechel RR, Herzog BA, Husmann L et al (2010) Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging 37:773–778CrossRefPubMed
12.
go back to reference Einstein AJ, Blankstein R, Andrews H et al (2014) Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J Nucl Med 55:1430–1437CrossRefPubMedPubMedCentral Einstein AJ, Blankstein R, Andrews H et al (2014) Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J Nucl Med 55:1430–1437CrossRefPubMedPubMedCentral
13.
go back to reference Nakazato R, Slomka PJ, Fish M et al (2015) Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22(2):266–275CrossRefPubMed Nakazato R, Slomka PJ, Fish M et al (2015) Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22(2):266–275CrossRefPubMed
14.
go back to reference Bradley-Moore PR, Lebowitz E, Greene MW, Atkins HL, Ansari AN (1975) Thallium-201 for medical use. II: Biologic behavior. J Nucl Med 16:156–160PubMed Bradley-Moore PR, Lebowitz E, Greene MW, Atkins HL, Ansari AN (1975) Thallium-201 for medical use. II: Biologic behavior. J Nucl Med 16:156–160PubMed
15.
go back to reference Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542CrossRefPubMed Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542CrossRefPubMed
16.
go back to reference Andersson M, Johansson L, Minarik D et al (2014) Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors. EJNMMI Phys 1(1):9CrossRefPubMedPubMedCentral Andersson M, Johansson L, Minarik D et al (2014) Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors. EJNMMI Phys 1(1):9CrossRefPubMedPubMedCentral
17.
go back to reference Leppo JA, Meerdink DJ (1989) Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ Res 65:632–639CrossRefPubMed Leppo JA, Meerdink DJ (1989) Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ Res 65:632–639CrossRefPubMed
18.
go back to reference Berman DS, Kang X, Tamarappoo B et al (2009) Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2(3):273–282CrossRefPubMed Berman DS, Kang X, Tamarappoo B et al (2009) Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2(3):273–282CrossRefPubMed
19.
go back to reference Matsunari I, Böning G, Ziegler SI et al (1998) Attenuation-corrected rest thallium-201/stress technetium 99m sestamibi myocardial SPECT in normals. J Nucl Cardiol 5(1):48–55CrossRefPubMed Matsunari I, Böning G, Ziegler SI et al (1998) Attenuation-corrected rest thallium-201/stress technetium 99m sestamibi myocardial SPECT in normals. J Nucl Cardiol 5(1):48–55CrossRefPubMed
20.
go back to reference Duvall WL, Guma KA, Kamen J et al (2013) Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: impact of stress-only imaging and high-efficiency SPECT camera technology. J Nucl Med 54(8):1251–1257CrossRefPubMed Duvall WL, Guma KA, Kamen J et al (2013) Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: impact of stress-only imaging and high-efficiency SPECT camera technology. J Nucl Med 54(8):1251–1257CrossRefPubMed
Metadata
Title
Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera
Authors
Vladimír Kincl
Milan Kamínek
Jiří Vašina
Roman Panovský
Martin Havel
Publication date
01-09-2016
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 9/2016
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-016-0919-8

Other articles of this Issue 9/2016

The International Journal of Cardiovascular Imaging 9/2016 Go to the issue