Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 6/2012

01-08-2012 | Original Paper

Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography

Authors: Byeong-Keuk Kim, Jung-Sun Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong

Published in: The International Journal of Cardiovascular Imaging | Issue 6/2012

Login to get access

Abstract

Minimal data have been published on the correlation between angiographic late loss (LL) and incomplete neointimal coverage of struts after drug-eluting stent (DES) implantation. Therefore, we evaluated the relationship between angiographic LL and the percentage of uncovered struts on follow-up optical coherence tomography (OCT) images, in all cross-sections of the lesions. From the OCT registry database, 219 lesions without restenosis after DES implantation were divided into tertiles based on angiographic LL: tertile I (LL ≤ 0.26 mm), tertile II (0.26 < LL < 0.59 mm), and tertile III (≥0.59 mm). Lesions with the percentage of uncovered struts in the highest quartile (≥75th percentile; >6.0%) were defined as highly uncovered; in an independent analysis, lesions without any uncovered strut(s) were defined as completely covered. Higher percentages of uncovered struts were observed in tertile I than in both tertile II and III (10.3 ± 12.8% vs. 4.2 ± 7.4% vs. 2.4 ± 5.1%, respectively; P < 0.001 for I vs. II and I vs. III). Angiographic LL correlated significantly with the percentage of uncovered struts on OCT (r = −0.340, P < 0.001). The best cut-off values of angiographic LL to predict highly uncovered and completely covered lesions were 0.29 mm (area under curves [AUC] = 0.723, P < 0.001) and 0.61 mm (AUC = 0.692, P < 0.001), respectively. Angiographic LL inversely and significantly correlated with the percentage of uncovered struts on OCT after DES implantation.
Literature
1.
go back to reference Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef
2.
go back to reference Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Jüni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW (2007) Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet 369:667–678PubMedCrossRef Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Jüni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW (2007) Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet 369:667–678PubMedCrossRef
3.
go back to reference Ellis SG, Popma JJ, Lasala JM, Koglin JJ, Cox DA, Hermiller J, O’shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Stone GW (2005) Relationship between angiographic late loss and target lesion revascularization after coronary stent implantation: analysis from the TAXUS-IV trial. J Am Coll Cardiol 45:1193–1200PubMedCrossRef Ellis SG, Popma JJ, Lasala JM, Koglin JJ, Cox DA, Hermiller J, O’shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Stone GW (2005) Relationship between angiographic late loss and target lesion revascularization after coronary stent implantation: analysis from the TAXUS-IV trial. J Am Coll Cardiol 45:1193–1200PubMedCrossRef
4.
go back to reference Mauri L, Orav EJ, Kuntz RE (2005) Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison. Circulation 111:3435–3442PubMedCrossRef Mauri L, Orav EJ, Kuntz RE (2005) Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison. Circulation 111:3435–3442PubMedCrossRef
5.
go back to reference Mauri L, Orav EJ, Candia SC, Cutlip DE, Kuntz RE (2005) Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials. Circulation 112:2833–2839PubMedCrossRef Mauri L, Orav EJ, Candia SC, Cutlip DE, Kuntz RE (2005) Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials. Circulation 112:2833–2839PubMedCrossRef
6.
go back to reference Moreno R, Fernandez C, Sanchez-Recalde A, Galeote G, Calvo L, Alfonso F, Hernandez R, Sánchez-Aquino R, Angiolillo DJ, Villarreal S, Macaya C, Lopez-Sendon JL (2007) Clinical impact of in-stent late loss after drug-eluting coronary stent implantation. Eur Heart J 28:1583–1591PubMedCrossRef Moreno R, Fernandez C, Sanchez-Recalde A, Galeote G, Calvo L, Alfonso F, Hernandez R, Sánchez-Aquino R, Angiolillo DJ, Villarreal S, Macaya C, Lopez-Sendon JL (2007) Clinical impact of in-stent late loss after drug-eluting coronary stent implantation. Eur Heart J 28:1583–1591PubMedCrossRef
7.
go back to reference Pocock SJ, Lansky AJ, Mehran R, Popma JJ, Fahy MP, Na Y, Dangas G, Moses JW, Pucelikova T, Kandzari DE, Ellis SG, Leon MB, Stone GW (2008) Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials. J Am Coll Cardiol 51:23–32PubMedCrossRef Pocock SJ, Lansky AJ, Mehran R, Popma JJ, Fahy MP, Na Y, Dangas G, Moses JW, Pucelikova T, Kandzari DE, Ellis SG, Leon MB, Stone GW (2008) Angiographic surrogate end points in drug-eluting stent trials: a systematic evaluation based on individual patient data from 11 randomized, controlled trials. J Am Coll Cardiol 51:23–32PubMedCrossRef
8.
go back to reference Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706PubMedCrossRef Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706PubMedCrossRef
9.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef
10.
go back to reference Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef
11.
go back to reference Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247PubMedCrossRef Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247PubMedCrossRef
12.
go back to reference Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51:968–969PubMedCrossRef Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51:968–969PubMedCrossRef
13.
go back to reference Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef
14.
go back to reference Chen BX, Ma FY, Luo W, Ruan JH, Xie WL, Zhao XZ, Sun SH, Guo XM, Wang F, Tian T, Chu XW (2008) Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 94:566–570PubMedCrossRef Chen BX, Ma FY, Luo W, Ruan JH, Xie WL, Zhao XZ, Sun SH, Guo XM, Wang F, Tian T, Chu XW (2008) Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 94:566–570PubMedCrossRef
15.
go back to reference Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (2010). Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415 (For the expert’s OCT review document) Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (2010). Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415 (For the expert’s OCT review document)
16.
go back to reference Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, Di Mario C (2010) Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol 141:151–156PubMedCrossRef Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, Di Mario C (2010) Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol 141:151–156PubMedCrossRef
17.
go back to reference Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef
18.
go back to reference Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 115:1440–1455PubMedCrossRef Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 115:1440–1455PubMedCrossRef
19.
go back to reference Rivero F, Moreno R, Barreales L, Galeote G, Sánchez-Recalde A, Calvo L, Jimenez-Valero S, Villate A, Vanegas M, López-Sendón JL (2008) Lower levels of in-stent late loss are not associated with the risk of stent thrombosis in patients receiving drug-eluting stents. EuroIntervention 4:124–132PubMedCrossRef Rivero F, Moreno R, Barreales L, Galeote G, Sánchez-Recalde A, Calvo L, Jimenez-Valero S, Villate A, Vanegas M, López-Sendón JL (2008) Lower levels of in-stent late loss are not associated with the risk of stent thrombosis in patients receiving drug-eluting stents. EuroIntervention 4:124–132PubMedCrossRef
20.
go back to reference Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef
21.
go back to reference Garg P, Cohen DJ, Gaziano T, Mauri L (2008) Balancing the risks of restenosis and stent thrombosis in bare-metal versus drug-eluting stents: results of a decision analytic model. J Am Coll Cardiol 51:1844–1853PubMedCrossRef Garg P, Cohen DJ, Gaziano T, Mauri L (2008) Balancing the risks of restenosis and stent thrombosis in bare-metal versus drug-eluting stents: results of a decision analytic model. J Am Coll Cardiol 51:1844–1853PubMedCrossRef
Metadata
Title
Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography
Authors
Byeong-Keuk Kim
Jung-Sun Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
Publication date
01-08-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 6/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9944-9

Other articles of this Issue 6/2012

The International Journal of Cardiovascular Imaging 6/2012 Go to the issue