Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2011

Open Access 01-02-2011 | Original Paper

Dedicated bifurcation analysis: basic principles

Authors: Joan C. Tuinenburg, Gerhard Koning, Andrei Rareş, Johannes P. Janssen, Alexandra J. Lansky, Johan H. C. Reiber

Published in: The International Journal of Cardiovascular Imaging | Issue 2/2011

Login to get access

Abstract

Over the last several years significant interest has arisen in bifurcation stenting, in particular stimulated by the European Bifurcation Club. Traditional straight vessel analysis by QCA does not satisfy the requirements for such complex morphologies anymore. To come up with practical solutions, we have developed two models, a Y-shape and a T-shape model, suitable for bifurcation QCA analysis depending on the specific anatomy of the coronary bifurcation. The principles of these models are described in this paper, as well as the results of validation studies carried out on clinical materials. It can be concluded that the accuracy, precision and applicability of these new bifurcation analyses are conform the general guidelines that have been set many years ago for conventional QCA-analyses.
Literature
1.
go back to reference Tu S, Koning G, Jukema W, Reiber JHC (2010) Assessment of obstruction length an optimal viewing angle from biplane X-ray angiograms. Int J Cardiovasc Imaging 26:5–17PubMedCrossRef Tu S, Koning G, Jukema W, Reiber JHC (2010) Assessment of obstruction length an optimal viewing angle from biplane X-ray angiograms. Int J Cardiovasc Imaging 26:5–17PubMedCrossRef
2.
go back to reference Tu S, Huang Z, Koning G, Cui K, Reiber JHC (2010) A novel three-dimensional quantitative coronary angiography system: in vivo comparison with intravascular ultrasound for assessing arterial segment length. Catheter Cardiovasc Interv 76:291–298PubMedCrossRef Tu S, Huang Z, Koning G, Cui K, Reiber JHC (2010) A novel three-dimensional quantitative coronary angiography system: in vivo comparison with intravascular ultrasound for assessing arterial segment length. Catheter Cardiovasc Interv 76:291–298PubMedCrossRef
4.
go back to reference Lefevre T, Louvard Y, Morice MC, Loubeyre C, Piechaud JF, Dumas P (2001) Stenting of bifurcation lesions: a rational approach. J Interv Cardiol 14(6):573–585PubMedCrossRef Lefevre T, Louvard Y, Morice MC, Loubeyre C, Piechaud JF, Dumas P (2001) Stenting of bifurcation lesions: a rational approach. J Interv Cardiol 14(6):573–585PubMedCrossRef
5.
go back to reference Lespérance J, Bilodeau L, Reiber JHC, Koning G, Hudon G, Bourassa M (1998) Issues in the performance of quantitative coronary angiography in clinical research trials. In: Reiber JHC, van der Wall EE (eds) What’s new in cardiovascular imaging?. Kluwer Academic Publishers, Dordrecht, pp 31–46 Lespérance J, Bilodeau L, Reiber JHC, Koning G, Hudon G, Bourassa M (1998) Issues in the performance of quantitative coronary angiography in clinical research trials. In: Reiber JHC, van der Wall EE (eds) What’s new in cardiovascular imaging?. Kluwer Academic Publishers, Dordrecht, pp 31–46
6.
go back to reference Beleslin B, Ostojic M, Nedeljkovic M et al (1995) Assessment of the reproducibility of the basic parameters obtained from quantitative coronary arteriography analyses. Eur Heart J 16(abstract Suppl):296 Beleslin B, Ostojic M, Nedeljkovic M et al (1995) Assessment of the reproducibility of the basic parameters obtained from quantitative coronary arteriography analyses. Eur Heart J 16(abstract Suppl):296
7.
go back to reference Janssen JP, Koning G, de Koning PJ, Tuinenburg JC, Reiber JHC (2002) A novel approach for the detection of pathlines in X-ray angiograms: the wavefront propagation algorithm. Int J Cardiovasc Imaging 18(5):317–324PubMedCrossRef Janssen JP, Koning G, de Koning PJ, Tuinenburg JC, Reiber JHC (2002) A novel approach for the detection of pathlines in X-ray angiograms: the wavefront propagation algorithm. Int J Cardiovasc Imaging 18(5):317–324PubMedCrossRef
8.
go back to reference Janssen JP, Koning G, de Koning PJ, Tuinenburg JC, Reiber JH (2004) Validation of a new method for the detection of pathlines in vascular x-ray images. Invest Radiol 39(9):524–530PubMedCrossRef Janssen JP, Koning G, de Koning PJ, Tuinenburg JC, Reiber JH (2004) Validation of a new method for the detection of pathlines in vascular x-ray images. Invest Radiol 39(9):524–530PubMedCrossRef
9.
go back to reference Reiber JHC, Serruys PW, Kooijman CJ, Wijns W, Slager CJ, Gerbrands JJ et al (1985) Assessment of short-, medium-, long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation 71(2):280–288PubMed Reiber JHC, Serruys PW, Kooijman CJ, Wijns W, Slager CJ, Gerbrands JJ et al (1985) Assessment of short-, medium-, long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation 71(2):280–288PubMed
10.
go back to reference Reiber JHC, van der Zwet PM, Koning G, von Land CD, van Meurs B, Gerbrands JJ et al (1993) Accuracy, precision of quantitative digital coronary arteriography: observer-, short-, medium-term variabilities. Cathet Cardiovasc Diagn 28(3):187–198PubMed Reiber JHC, van der Zwet PM, Koning G, von Land CD, van Meurs B, Gerbrands JJ et al (1993) Accuracy, precision of quantitative digital coronary arteriography: observer-, short-, medium-term variabilities. Cathet Cardiovasc Diagn 28(3):187–198PubMed
11.
go back to reference Reiber JHC, Koning G, Dijkstra J, Wahle A, Goedhart B, Sheehan FH et al (2001) Angiography and intravascular ultrasound. In: Sonka M, Fitzpatrick JM (eds) Handbook of medical imaging—volume 2: medical image processing and analysis. SPIE Press, Belligham, pp 711–808 Reiber JHC, Koning G, Dijkstra J, Wahle A, Goedhart B, Sheehan FH et al (2001) Angiography and intravascular ultrasound. In: Sonka M, Fitzpatrick JM (eds) Handbook of medical imaging—volume 2: medical image processing and analysis. SPIE Press, Belligham, pp 711–808
12.
go back to reference Reiber JHC, Tuinenburg JC, Koning G, Janssen JP, Rares A, Lansky AJ, Goedhart B (2009) Ch 2.2 Quantitative coronary arteriography. In: Oudkerk M, Reiser MF (eds) Medical radiology—Diagnostic imaging, volume Coronary radiology, 2nd revised edn. Springer-Verlag, Berlin/Heidelberg, pp 41–65 Reiber JHC, Tuinenburg JC, Koning G, Janssen JP, Rares A, Lansky AJ, Goedhart B (2009) Ch 2.2 Quantitative coronary arteriography. In: Oudkerk M, Reiser MF (eds) Medical radiology—Diagnostic imaging, volume Coronary radiology, 2nd revised edn. Springer-Verlag, Berlin/Heidelberg, pp 41–65
13.
go back to reference Lansky AJ, Tuinenburg JC, Costa M, Maeng M, Koning G, Popma J et al (2009) Quantitative angiographic methods for bifurcation lesions: A consensus statement from the European Bifurcation Group. Catheter Cardiovasc Intervent 73:258–266CrossRef Lansky AJ, Tuinenburg JC, Costa M, Maeng M, Koning G, Popma J et al (2009) Quantitative angiographic methods for bifurcation lesions: A consensus statement from the European Bifurcation Group. Catheter Cardiovasc Intervent 73:258–266CrossRef
14.
go back to reference Reiber JHC, Koning G, von Land CD, van der Zwet PM (1994) Why and how should QCA systems be validated? In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 33–48 Reiber JHC, Koning G, von Land CD, van der Zwet PM (1994) Why and how should QCA systems be validated? In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 33–48
15.
go back to reference Reiber JHC, von Land CD, Koning G, van der Zwet PM, van Houdt R, Schalij M et al (1994) Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systems. In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 67–85 Reiber JHC, von Land CD, Koning G, van der Zwet PM, van Houdt R, Schalij M et al (1994) Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systems. In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 67–85
16.
go back to reference Beauman G, Reiber JHC, Koning G, van Houdt R, Vogel R (1994) Angiographic core laboratories analyses of arterial phantom images: Comparative evaluations of accuracy and precision. In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 87–104 Beauman G, Reiber JHC, Koning G, van Houdt R, Vogel R (1994) Angiographic core laboratories analyses of arterial phantom images: Comparative evaluations of accuracy and precision. In: Reiber JHC, Serruys PW (eds) Progress in quantitative coronary arteriography. Kluwer Academic Publishers, Dordrecht, pp 87–104
17.
go back to reference Janssen JP, Rares A, Tuinenburg JC, Koning G, Lansky AJ, Reiber JHC (2010) New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis. Int J Cardiovasc Imaging 26(3):259–271PubMedCrossRef Janssen JP, Rares A, Tuinenburg JC, Koning G, Lansky AJ, Reiber JHC (2010) New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis. Int J Cardiovasc Imaging 26(3):259–271PubMedCrossRef
Metadata
Title
Dedicated bifurcation analysis: basic principles
Authors
Joan C. Tuinenburg
Gerhard Koning
Andrei Rareş
Johannes P. Janssen
Alexandra J. Lansky
Johan H. C. Reiber
Publication date
01-02-2011
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 2/2011
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-010-9795-9

Other articles of this Issue 2/2011

The International Journal of Cardiovascular Imaging 2/2011 Go to the issue