To examine in vitro whether an assessment of flow in normal and obstructed vessels is essentially possible using modern multislice CT-scanners. An experimental model allowed known stenoses to be perfused at defined flow rates. Aorta and coronary arteries were simulated by silicone tubes. A pulsatile pump was used to perfuse water through the system with intermittent injection of a bolus of radio-opaque contrast agent. CT-measurements were carried out with slice orientation perpendicular to the tubes. 50–90% concentric stenoses were examined 5 times at 4 different stenosis slice distances. A mathematical algorithm calculated the temporal density changes within a ROI in the tube cross-sections. Quantitative assessment of the data simultaneously acquired with the 16-slice system for the “coronary” and “aortal” time-density curves showed that the model allowed for exclusion of a ≥ 80% stenosis grade with a 99% probability when the slopes of the density increase quotient was > 0.79; a stenosis grade of ≥ 90% could be excluded when the slopes of the density increase quotient was > 0.52. A Quotient > 0.94 for “peak density” was associated with a 99% probability of a stenosis grade ≥ 70%. The 64-slice system allowed stenosis grades of ≥ 80% to be discriminated from lower grades. The general feasibility of the in vitro approach was verified in an in vivo model. The spatial, contrast and temporal resolution of CT scanners with at least 16 detector rows enables qualitative and semiquantitative assessment of stenotic changes in flow.
Literature
1.
go back to reference Bluemke DA, Achenbach S, Budoff M et al (2008) Noninvasive coronary artery imaging: magnetic resonance angiography and multidetector computed tomography angiography: a scientific statement from the american heart association committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young. Circulation 118(5):586–606. Epub 2008 Jun 27 Bluemke DA, Achenbach S, Budoff M et al (2008) Noninvasive coronary artery imaging: magnetic resonance angiography and multidetector computed tomography angiography: a scientific statement from the american heart association committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young. Circulation 118(5):586–606. Epub 2008 Jun 27
2.
go back to reference Budoff MJ, Dowe D, Jollis JG et al (2008) Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 52(21):1724–1732PubMedCrossRef Budoff MJ, Dowe D, Jollis JG et al (2008) Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 52(21):1724–1732PubMedCrossRef
3.
go back to reference Garcia MJ, Lessick J, Hoffmann KH for the CATSCAN Study Investigators (2006) Accuracy of 16-row multidetecor computed tomography for the assessment of coronary artery stenosis. JAMA 296:403–411 Garcia MJ, Lessick J, Hoffmann KH for the CATSCAN Study Investigators (2006) Accuracy of 16-row multidetecor computed tomography for the assessment of coronary artery stenosis. JAMA 296:403–411
4.
go back to reference Groothuis JG, Beek AM, Brinckman SL et al (2010) Low to intermediate probability of coronary artery disease: comparison of coronary CT angiography with first-pass MR myocardial perfusion imaging. Radiology 254:384–392PubMedCrossRef Groothuis JG, Beek AM, Brinckman SL et al (2010) Low to intermediate probability of coronary artery disease: comparison of coronary CT angiography with first-pass MR myocardial perfusion imaging. Radiology 254:384–392PubMedCrossRef
5.
go back to reference Mowatt G, Cook JA, Hillis GS, Walker S, Fraser C et al (2008) 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94(11):1386–1393. (Epub) 2008 Jul 31. Review Mowatt G, Cook JA, Hillis GS, Walker S, Fraser C et al (2008) 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94(11):1386–1393. (Epub) 2008 Jul 31. Review
6.
go back to reference Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructed coronary artery disease. Circulation 110:2638–2643PubMedCrossRef Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructed coronary artery disease. Circulation 110:2638–2643PubMedCrossRef
7.
go back to reference Meijboom WB, Meijs MF, Schuijf JD et al (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144PubMedCrossRef Meijboom WB, Meijs MF, Schuijf JD et al (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144PubMedCrossRef
8.
go back to reference Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359(22):2324–2336PubMedCrossRef Miller JM, Rochitte CE, Dewey M et al (2008) Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 359(22):2324–2336PubMedCrossRef
9.
go back to reference Gould KL (2009) Does coronary flow trump coronary anatomy? JACC Cardiovasc Imaging 2(8):1009–1023PubMedCrossRef Gould KL (2009) Does coronary flow trump coronary anatomy? JACC Cardiovasc Imaging 2(8):1009–1023PubMedCrossRef
10.
go back to reference Axel L (1983) Tissue mean tranit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 18:94–99PubMedCrossRef Axel L (1983) Tissue mean tranit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 18:94–99PubMedCrossRef
11.
go back to reference Bell MR, Lerman LO, Rumberger JA (1999) Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers. Heart 81:628–635PubMed Bell MR, Lerman LO, Rumberger JA (1999) Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers. Heart 81:628–635PubMed
12.
go back to reference Rumberger JA, Feiring AJ, Lipton MJ, Higgins CB, Ell SR, Marcus ML (1987) Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a premininary report. J Am Coll Cardiol 9:59–69PubMedCrossRef Rumberger JA, Feiring AJ, Lipton MJ, Higgins CB, Ell SR, Marcus ML (1987) Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a premininary report. J Am Coll Cardiol 9:59–69PubMedCrossRef
13.
go back to reference Wang T, Wu X, Chung N, Ritman EL (1989) Myocardial blood flow estimated by synchronous multislice, high-speed computed tomography. IEEE Trans Med Imaging 8(1):70–76PubMedCrossRef Wang T, Wu X, Chung N, Ritman EL (1989) Myocardial blood flow estimated by synchronous multislice, high-speed computed tomography. IEEE Trans Med Imaging 8(1):70–76PubMedCrossRef
14.
go back to reference Wolfkiel CJ, Ferguson JL, Chomka EV, Law WR, Labin IN, Tenzer ML, Booker M, Brundage BH (1987) Measurement of myocardial blood flow by ultrafast computed tomography. Circulation 76:1262–1273PubMedCrossRef Wolfkiel CJ, Ferguson JL, Chomka EV, Law WR, Labin IN, Tenzer ML, Booker M, Brundage BH (1987) Measurement of myocardial blood flow by ultrafast computed tomography. Circulation 76:1262–1273PubMedCrossRef
15.
go back to reference Nagao M, Kido T, Watanabe K, Saeki H, Okayama H, Kurata A, Hosokawa K, Higashino H, Mochizuki T (2010) Functional assessment of coronary artery flow using adenosine stress dual-energy CT: a preliminary study. Int J Cardiovasc Imaging 26(6):567–569 Nagao M, Kido T, Watanabe K, Saeki H, Okayama H, Kurata A, Hosokawa K, Higashino H, Mochizuki T (2010) Functional assessment of coronary artery flow using adenosine stress dual-energy CT: a preliminary study. Int J Cardiovasc Imaging 26(6):567–569
Metadata
Title
In vitro measurements of flow using multislice computed tomography (MSCT)
Authors
Klaus Lackner
Henning Bovenschulte
Hartmut Stützer
Thomas Just
Hassan Al-Hassani
Barbara Krug
Publication date
01-07-2011
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 6/2011
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-010-9728-7

Other articles of this Issue 6/2011

The International Journal of Cardiovascular Imaging 6/2011 Go to the issue