Differential Use of Image Enhancement Techniques by Experienced and Inexperienced Observers

Authors: Elizabeth A. Krupinski, Ph.D., Hans Roehrig, Ph.D., William Dallas, Ph.D., Jiahua Fan, M.S.

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2005

Login to get access

Abstract

Full-field digital mammography (FFDM) systems are currently being used to acquire mammograms in digital format, but digital displays are less than ideal compared to traditional film-screen display. Certain physical properties of softcopy displays [e.g., modulation transfer function (MTF)] are less than optimal compared to film. We developed methods to compensate for some of these softcopy display deficiencies, based on careful physical characterization of the displays and image-processing software. A series of 100 FFDM and 60 digitized images was shown to six observers—half experienced (mammographers) and half inexperienced (radiology residents). The observers had to decide if a mass or microcalcification cluster was present and classify it as benign or malignant. A window could be activated that brought the image detail within the window to full resolution and corrected for the nonisotropic MTF of the Cathode Ray Tube (CRT) display. Experienced readers had better diagnostic performance and took less time to view the images. Experienced readers used window/level more than inexperienced readers, but inexperienced readers used magnification and the MTF compensation tool more often. Use of the magnification and the MTF tool increased reader decision confidence. Experienced and inexperienced readers use image-processing tools differently, with certain tools increasing reader confidence. Understanding how observers use image-processing tools may help in the development of better and more automated user interfaces.
Literature
1.
go back to reference Fischer, U, Baum, F, Obenauer, S, et al. 2002Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammographyEur Radiol1226792683PubMed Fischer, U, Baum, F, Obenauer, S,  et al. 2002Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammographyEur Radiol1226792683PubMed
2.
go back to reference Obenauer, S, Hermann, KP, Marten, K, et al. 2003Soft copy versus hard copy reading in digital mammographyJ Digit Imaging16341344CrossRefPubMed Obenauer, S, Hermann, KP, Marten, K,  et al. 2003Soft copy versus hard copy reading in digital mammographyJ Digit Imaging16341344CrossRefPubMed
3.
go back to reference Cole, E, Pisano, ED, Brown, M, et al. 2004Diagnostic accuracy of Fischer Senoscan Digital Mammography versus screen-film mammography in a diagnostic mammography populationAcad Radiol11879886CrossRefPubMed Cole, E, Pisano, ED, Brown, M,  et al. 2004Diagnostic accuracy of Fischer Senoscan Digital Mammography versus screen-film mammography in a diagnostic mammography populationAcad Radiol11879886CrossRefPubMed
4.
go back to reference Pisano, ED, Cole, EB, Kistner, EO, et al. 2002Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film displayRadiol223483488 Pisano, ED, Cole, EB, Kistner, EO,  et al. 2002Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film displayRadiol223483488
5.
go back to reference Krupinski, EA, Johnson, J, Roehrig, H, Nafziger, J, Fan, J, Lubin, J 2004Use of a human visual system model to predict observer performance with CRT vs LCD display of imagesJ Digit Imaging17258263CrossRefPubMed Krupinski, EA, Johnson, J, Roehrig, H, Nafziger, J, Fan, J, Lubin, J 2004Use of a human visual system model to predict observer performance with CRT vs LCD display of imagesJ Digit Imaging17258263CrossRefPubMed
6.
go back to reference Badano, A, Flynn, MJ, Martin, S, Kanicki, J 2003Angular dependence of the luminance and contrast in medical monochrome liquid crystal displaysMed Phys3026022613CrossRefPubMed Badano, A, Flynn, MJ, Martin, S, Kanicki, J 2003Angular dependence of the luminance and contrast in medical monochrome liquid crystal displaysMed Phys3026022613CrossRefPubMed
7.
go back to reference Kundel, HL, Weinstein, SP, Conant, EF, Toto, LC, Nodine, CF 1999A perceptually tempered display for digital mammogramsRadiographics1913131318PubMed Kundel, HL, Weinstein, SP, Conant, EF, Toto, LC, Nodine, CF 1999A perceptually tempered display for digital mammogramsRadiographics1913131318PubMed
8.
go back to reference Pisano, ED, Cole, EB, Hemminger, BM, Yaffe, MJ, Aylward, SR, et al. 2000Image processing algorithms for digital mammography: a pictorial essayRadiographics2014791491PubMed Pisano, ED, Cole, EB, Hemminger, BM, Yaffe, MJ, Aylward, SR,  et al. 2000Image processing algorithms for digital mammography: a pictorial essayRadiographics2014791491PubMed
9.
go back to reference Hemminger, BM, Zong, S, Muller, KE, Coffey, CS, et al. 2001Improving the detection of simulated masses in mammograms through two different image-processing techniquesAcad Radiol8845855CrossRefPubMed Hemminger, BM, Zong, S, Muller, KE, Coffey, CS,  et al. 2001Improving the detection of simulated masses in mammograms through two different image-processing techniquesAcad Radiol8845855CrossRefPubMed
10.
go back to reference Stefanoyiannis, AP, Costaridou, L, Skiadopoulos, S, Panayiotakis, G 2003A digital equalization technique improving visualization of dense mammary gland and breast periphery in mammographyEur J Radiol45139149CrossRefPubMed Stefanoyiannis, AP, Costaridou, L, Skiadopoulos, S, Panayiotakis, G 2003A digital equalization technique improving visualization of dense mammary gland and breast periphery in mammographyEur J Radiol45139149CrossRefPubMed
11.
go back to reference Cole, EB, Pisano, ED, Kistner, EO, Muller, KE, Brown, ME, Feig, ME, et al. 2003Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: effects of image processing and lesion typeRadiol.216153160 Cole, EB, Pisano, ED, Kistner, EO, Muller, KE, Brown, ME, Feig, ME,  et al. 2003Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: effects of image processing and lesion typeRadiol.216153160
12.
go back to reference Kallergi, M, Heine, JJ, Berman, CG, Hersh, MR, Romilly, AP, Clark, AP 2004Improved interpretation of digitized mammography with wavelet processing: a localization response operating characteristic studyAm J Roentgenol182697703 Kallergi, M, Heine, JJ, Berman, CG, Hersh, MR, Romilly, AP, Clark, AP 2004Improved interpretation of digitized mammography with wavelet processing: a localization response operating characteristic studyAm J Roentgenol182697703
13.
go back to reference Nunes, FL, Schiabel, H, Benatti, RH 2002Contrast enhancement in dense breast images using the modulation transfer functionMed Phys2929252936CrossRefPubMed Nunes, FL, Schiabel, H, Benatti, RH 2002Contrast enhancement in dense breast images using the modulation transfer functionMed Phys2929252936CrossRefPubMed
14.
go back to reference Krupinski, EA, Johnson, J, Roehrig, H, Engstrom, M, et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of MTF compensationAcad Radiol1010301035CrossRefPubMed Krupinski, EA, Johnson, J, Roehrig, H, Engstrom, M,  et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of MTF compensationAcad Radiol1010301035CrossRefPubMed
15.
go back to reference Reiker, GG, Blume, H, Slone, RM, Woodward, PM, et al. 1997Filmless digital chest radiography within the radiology departmentProc SPIE Med Imag3035355368CrossRef Reiker, GG, Blume, H, Slone, RM, Woodward, PM,  et al. 1997Filmless digital chest radiography within the radiology departmentProc SPIE Med Imag3035355368CrossRef
16.
go back to reference Roehrig, H 2000The monochrome cathode ray tube display and its performanceKim, YHorii, SC eds. Handbook of Medical Imaging Volume 3. Display and PACSSPIE PressBellingham, WA155220 Roehrig, H 2000The monochrome cathode ray tube display and its performanceKim, YHorii, SC eds. Handbook of Medical Imaging Volume 3. Display and PACSSPIE PressBellingham, WA155220
17.
go back to reference Blume, H, Steven, P, Ho, A, Stevens, F, Abileah, A, Robinson, S, et al. 2003Characterization of liquid-crystal displays for medical images—part 2Proc SPIE Med Imag5029449473CrossRef Blume, H, Steven, P, Ho, A, Stevens, F, Abileah, A, Robinson, S,  et al. 2003Characterization of liquid-crystal displays for medical images—part 2Proc SPIE Med Imag5029449473CrossRef
18.
go back to reference Dorfman, DD, Berbaum, KS, Metz, CE 1992Receiver operating characteristic analysis: generalization to the population of readers and patients with the jackknife methodInvest Radiol27723731PubMed Dorfman, DD, Berbaum, KS, Metz, CE 1992Receiver operating characteristic analysis: generalization to the population of readers and patients with the jackknife methodInvest Radiol27723731PubMed
19.
go back to reference Krupinski, EA 1996Visual scanning patterns of radiologists searching mammogramsAcad Radiol3137144PubMed Krupinski, EA 1996Visual scanning patterns of radiologists searching mammogramsAcad Radiol3137144PubMed
20.
go back to reference Nodine, CF, Mello-Thoms, C, Kundel, HL, Weinstein, SP 2002Time course of perception and decision making during mammographic interpretationAm J Roentgenol179917923 Nodine, CF, Mello-Thoms, C, Kundel, HL, Weinstein, SP 2002Time course of perception and decision making during mammographic interpretationAm J Roentgenol179917923
Metadata
Title
Differential Use of Image Enhancement Techniques by Experienced and Inexperienced Observers
Authors
Elizabeth A. Krupinski, Ph.D.
Hans Roehrig, Ph.D.
William Dallas, Ph.D.
Jiahua Fan, M.S.
Publication date
01-12-2005
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2005
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-005-7666-z

Other articles of this Issue 4/2005

Journal of Digital Imaging 4/2005 Go to the issue

OriginalPaper

Blogging Your PACS