Abstract

This Project evaluated a human visual system model (JNDmetrix) based on just noticeable difference (JND) and frequency-channel vision-modeling principles to assess whether a Cathode ray tube (CRT) or a liquid crystal display (LCD) monochrome display monitor would yield better observer performance in radiographic interpretation. Key physical characteristics, such as veiling glare and modulation transfer function (MTF) of the CRT and LCD were measured. Regions of interest from mammographic images with masses of different contrast levels were shown once on each display to six radiologists using a counterbalanced presentation order. The images were analyzed using the JNDmetrix model. Performance as measured by receiver operating characteristic (ROC) analysis was significantly better overall on the LCD display (P = 0.0120). The JNDmetrix model predicted the result (P = 0.0046) and correlation between human and computer observers was high (r 2 (quadratic) = 0.997). The results suggest that observer performance with LCD displays is superior to CRT viewing, at least for on-axis viewing.
Literature
1.
go back to reference Huang, HK 2003Some historical remarks on picture archiving and communication systemsComput Med Imaging Graph279399CrossRefPubMed Huang, HK 2003Some historical remarks on picture archiving and communication systemsComput Med Imaging Graph279399CrossRefPubMed
2.
go back to reference Sinha, U, Bui, A, Taira, R, et al. 2002A review of medical imaging informaticsAnn Med Imaging Inform980168197 Sinha, U, Bui, A, Taira, R,  et al. 2002A review of medical imaging informaticsAnn Med Imaging Inform980168197
4.
go back to reference Bennett, WF, Vaswani, KK, Mendiola, JA, et al. 2002PACS monitors: an evolution of radiologists’ viewing techniquesJ Digit Imaging15171174CrossRefPubMed Bennett, WF, Vaswani, KK, Mendiola, JA,  et al. 2002PACS monitors: an evolution of radiologists’ viewing techniquesJ Digit Imaging15171174CrossRefPubMed
5.
go back to reference Horii, SC 2002WorkstationsMehta, ADreyer, KJThrall, JH eds. PACS: A Guide to the Digital RevolutionSpringer-VerlagNew York191235 Horii, SC 2002WorkstationsMehta, ADreyer, KJThrall, JH eds. PACS: A Guide to the Digital RevolutionSpringer-VerlagNew York191235
6.
go back to reference Badano, A 2003Principles of cathode-ray tube and liquid crystal display devicesSamei, EFlynn, MJ eds. Advances in Digital Radiography: Categorical Course in Diagnostic Radiology Physics 2003 SyllabusRSNAOak Brook, IL91102 Badano, A 2003Principles of cathode-ray tube and liquid crystal display devicesSamei, EFlynn, MJ eds. Advances in Digital Radiography: Categorical Course in Diagnostic Radiology Physics 2003 SyllabusRSNAOak Brook, IL91102
7.
go back to reference Hwang, SA, Seo, JB, Choi, BK, et al. 2003Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodulesKorean J Radiol4153156PubMedCrossRef Hwang, SA, Seo, JB, Choi, BK,  et al. 2003Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodulesKorean J Radiol4153156PubMedCrossRef
8.
go back to reference Blume, H, Steven, PM, Cobb, M, et al. 2002Characterization of high-resolution liquid-crystal displays for medical imagesProc SPIE Med Imag4681271292CrossRef Blume, H, Steven, PM, Cobb, M,  et al. 2002Characterization of high-resolution liquid-crystal displays for medical imagesProc SPIE Med Imag4681271292CrossRef
9.
go back to reference Roehrig, H, Krupinski, E, Chawla, AS, et al. 2003Spatial noise and threshold contrasts in LCD displaysProc SPIE Med Imag5034174186CrossRef Roehrig, H, Krupinski, E, Chawla, AS,  et al. 2003Spatial noise and threshold contrasts in LCD displaysProc SPIE Med Imag5034174186CrossRef
10.
go back to reference Badano, A, Flynn, MJ 2000Method for measuring veiling glare in high-performance display devicesAppl Opt3920592066CrossRefPubMed Badano, A, Flynn, MJ 2000Method for measuring veiling glare in high-performance display devicesAppl Opt3920592066CrossRefPubMed
11.
go back to reference Krupinski, EA, Johnson, J, Roehrig, H, et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of display phosphorAcad Radiol10161166PubMed Krupinski, EA, Johnson, J, Roehrig, H,  et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of display phosphorAcad Radiol10161166PubMed
12.
go back to reference Krupinski, EA, Johnson, J, Roehrig, H, et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of MTF compensationAcad Radiol1010301035PubMed Krupinski, EA, Johnson, J, Roehrig, H,  et al. 2003Using a human visual system model to optimize soft-copy mammography display: influence of MTF compensationAcad Radiol1010301035PubMed
13.
go back to reference Johnson, JP, Nafziger, J, Krupinski, EA, et al. 2003Effects of grayscale window/level parameters on breast lesion detectabilityProc SPIE Med Imag5034462473CrossRef Johnson, JP, Nafziger, J, Krupinski, EA,  et al. 2003Effects of grayscale window/level parameters on breast lesion detectabilityProc SPIE Med Imag5034462473CrossRef
14.
go back to reference Roehrig, H 2000The monochrome cathode ray tube and its performanceKim, YHorii, SC eds. Handbook of Medical Imaging, Volume 3. Display and PACSSPIE PressBellingham, WA155220 Roehrig, H 2000The monochrome cathode ray tube and its performanceKim, YHorii, SC eds. Handbook of Medical Imaging, Volume 3. Display and PACSSPIE PressBellingham, WA155220
15.
go back to reference Lubin, J 1995A visual system discrimination model for imaging system design and evaluationPeli, E eds. Visual Models for Target Detection and RecognitionWorld Scientific PublishersRiver Edge, NJ245283 Lubin, J 1995A visual system discrimination model for imaging system design and evaluationPeli, E eds. Visual Models for Target Detection and RecognitionWorld Scientific PublishersRiver Edge, NJ245283
16.
go back to reference Lubin, J 1993The use of psychophysical data and models in the analysis of display system performanceWatson, AB eds. Digital Images and Human VisionMIT PressCambridge MA163178 Lubin, J 1993The use of psychophysical data and models in the analysis of display system performanceWatson, AB eds. Digital Images and Human VisionMIT PressCambridge MA163178
18.
go back to reference Dorfman, DD, Berbaum, KS, Metz, CE 1992Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife methodInvest Radiol27723731PubMed Dorfman, DD, Berbaum, KS, Metz, CE 1992Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife methodInvest Radiol27723731PubMed
19.
go back to reference Badano, A, Flynn, MJ, Martin, S, et al. 2003Angular dependence of the luminance and contrast in medical monochrome liquid crystal displaysMed Phys3026022613CrossRefPubMed Badano, A, Flynn, MJ, Martin, S,  et al. 2003Angular dependence of the luminance and contrast in medical monochrome liquid crystal displaysMed Phys3026022613CrossRefPubMed
20.
go back to reference Badano, A, Gallas, BD, Myers, KJ, et al. 2003Effect of viewing angle on visual detection in liquid crystal displaysProc SPIE Med Imag5029474483CrossRef Badano, A, Gallas, BD, Myers, KJ,  et al. 2003Effect of viewing angle on visual detection in liquid crystal displaysProc SPIE Med Imag5029474483CrossRef
Metadata
Title
Use of a Human Visual System Model to Predict Observer Performance with CRT vs LCD Display of Images
Authors
Elizabeth A. Krupinski, PhD
Jeffrey Johnson, PhD
Hans Roehrig, PhD
John Nafziger, PhD
Jiahua Fan, MS
Jeffery Lubin, PhD
Publication date
01-12-2004
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2004
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-004-1016-4

Other articles of this Issue 4/2004

Journal of Digital Imaging 4/2004 Go to the issue