Published in: Journal of Digital Imaging 1/2003

01-03-2003

The Digital Imaging Workstation

Authors: Ronald L. Arenson, M.D., Dev P. Chakraborty, Ph.D., Sridhar B. Seshadri, M.S.E.E., Harold L. Kundel, M.D.

Published in: Journal of Imaging Informatics in Medicine | Issue 1/2003

Login to get access

Abstract

Picture archiving and communication systems (PACS) are expected to convert film-based radiology into a computer-based digital environment, with associated cost savings and improved physician communication. The digital workstation will be used by physicians to display these “soft-copy” images; however, difficult technical challenges must be met for the workstation to compete successfully with the familiar viewbox. Issues relating to image perception and the impact on physicians’ practice must be carefully considered. The spatial and contrast resolutions required vary according to imaging modality, type of procedure, and class of user. Rule-based software allows simple physician interaction and speeds image display. A consensus appears to be emerging concerning the requirements for the PACS workstation. Standards such as the American College of Radiology/National Electrical Manufacturers’ Association Digital Imaging and Communication Standard are facilitating commercial applications. Yet much careful study is needed before PACS workstations will be fully integrated into radiology departments.
Literature
1.
go back to reference Seshadri SB, Arenson RL, DeSimone D, Hiss S: Cost-savings associated with a digital radiology department: a preliminary study. Presented at the Ninth Conference on Computer Applications in Radiology, Hilton Head, SC, June 1988 Seshadri SB, Arenson RL, DeSimone D, Hiss S: Cost-savings associated with a digital radiology department: a preliminary study. Presented at the Ninth Conference on Computer Applications in Radiology, Hilton Head, SC, June 1988
2.
go back to reference Gee, JC, DeSoto, LA, Kim, Y, Haynor, DR, Loop, JW 1989User interface design for a radiological imaging workstation.SPIE Med Imaging III1093122132 Gee, JC, DeSoto, LA, Kim, Y, Haynor, DR, Loop, JW 1989User interface design for a radiological imaging workstation.SPIE Med Imaging III1093122132
3.
go back to reference Braudes, SE, Mun, SK, Sibert, J, Schnizlein, J, Horii, S 1989Workstation modelling and development: clinical definition of a picture archiving and communication system (PACS) user interface.SPIE Med Imaging III1093376386 Braudes, SE, Mun, SK, Sibert, J, Schnizlein, J, Horii, S 1989Workstation modelling and development: clinical definition of a picture archiving and communication system (PACS) user interface.SPIE Med Imaging III1093376386
4.
go back to reference Cox, GG, McMillan, JH, Wetzel, LH, Siegel, EL, Templeton, AW, Dwyer III, SJ 1989Direct diagnosis from a 2,000 × 2,000 × 12-bit displays: comparison with hard copy (abstr).Radiology173471 Cox, GG, McMillan, JH, Wetzel, LH, Siegel, EL, Templeton, AW, Dwyer III, SJ 1989Direct diagnosis from a 2,000 × 2,000 × 12-bit displays: comparison with hard copy (abstr).Radiology173471
5.
go back to reference MacMahon, H, Metz, C, Doi, K, Kim, T, Giger, ML, Chan, H 1988Digital chest radiography: effect on diagnostic accuracy of hard copy.Radiology168669673PubMed MacMahon, H, Metz, C, Doi, K, Kim, T, Giger, ML, Chan, H 1988Digital chest radiography: effect on diagnostic accuracy of hard copy.Radiology168669673PubMed
6.
go back to reference Yamasaki, K, Sato, K, Kusumoto, M, Adachi, S, Kuno, M 1989Comparative studies of physical characteristics and clinical efficacy of digitized chest image (abstr).Radiology173226 Yamasaki, K, Sato, K, Kusumoto, M, Adachi, S, Kuno, M 1989Comparative studies of physical characteristics and clinical efficacy of digitized chest image (abstr).Radiology173226
7.
go back to reference Oestmann, JW, Greene, R, Rubens, JR, et al. 1989High-frequency edge enhancement in the detection of fine pulmonary lines.Invest Radiol24643646PubMed Oestmann, JW, Greene, R, Rubens, JR,  et al. 1989High-frequency edge enhancement in the detection of fine pulmonary lines.Invest Radiol24643646PubMed
8.
go back to reference Ishida, M, Frank, PH, Doi, K, Lehr, JL 1983High quality digital radiographic images: improved detection of low-contrast objects and preliminary clinical studies.RadioGraphics3325338 Ishida, M, Frank, PH, Doi, K, Lehr, JL 1983High quality digital radiographic images: improved detection of low-contrast objects and preliminary clinical studies.RadioGraphics3325338
9.
go back to reference Sheline, ME, Brikman, I, Epstein, D, Mezrich, J, Kundel, HL, Arenson, RL 1989The diagnosis of pulmonary nodules; comparison between standard and inverse digitized images and conventional chest radiographs.AJR152261263 Sheline, ME, Brikman, I, Epstein, D, Mezrich, J, Kundel, HL, Arenson, RL 1989The diagnosis of pulmonary nodules; comparison between standard and inverse digitized images and conventional chest radiographs.AJR152261263
10.
go back to reference Cornsweet, TH, Pensker, HM 1965Luminance discrimination of brief flashes under various conditions of adaption.J Physiol (Lond)176294310 Cornsweet, TH, Pensker, HM 1965Luminance discrimination of brief flashes under various conditions of adaption.J Physiol (Lond)176294310
11.
go back to reference Hendee, WR 1983The physical principles of computed tomography.Little BrownBoston Hendee, WR 1983The physical principles of computed tomography.Little BrownBoston
12.
go back to reference Kundel, HL, Nodine, CF, Thickman, D, Carmody, D, Toto, L 1985Nodule detection with and without a chest image.Invest Radiol209499PubMed Kundel, HL, Nodine, CF, Thickman, D, Carmody, D, Toto, L 1985Nodule detection with and without a chest image.Invest Radiol209499PubMed
13.
go back to reference Metz, CE 1986ROC methodology in radiologic imaging.Invest Radiol21720733PubMed Metz, CE 1986ROC methodology in radiologic imaging.Invest Radiol21720733PubMed
14.
go back to reference Foley, WD, Wilson, CR, Keyes, GS, et al. 1981The effect of varying spatial resolution on the detectability of diffuse pulmonary nodules.Radiology1412531PubMed Foley, WD, Wilson, CR, Keyes, GS,  et al. 1981The effect of varying spatial resolution on the detectability of diffuse pulmonary nodules.Radiology1412531PubMed
15.
go back to reference Huebener, K-H 1983Scanned projection radiography of the chest versus standard film radiography: a comparison of 250 cases.Radiology148363368PubMed Huebener, K-H 1983Scanned projection radiography of the chest versus standard film radiography: a comparison of 250 cases.Radiology148363368PubMed
16.
go back to reference Seeley, GW, Newell, JD 1985The use of psychophysical principles in the design of a total digital radiology department.Radiol Clin North Am23341348PubMed Seeley, GW, Newell, JD 1985The use of psychophysical principles in the design of a total digital radiology department.Radiol Clin North Am23341348PubMed
17.
go back to reference MacMahon, H, Vyborny, CJ, Metz, CE, Doi, K, Sabeti, V, Solomon, S 1986Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.Radiology1582126PubMed MacMahon, H, Vyborny, CJ, Metz, CE, Doi, K, Sabeti, V, Solomon, S 1986Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.Radiology1582126PubMed
18.
go back to reference Lams, PM, Cocklin, ML 1986Spatial resolution requirements for digital chest radiographs: an ROC study of observer performance in selected cases.Radiology1581119PubMed Lams, PM, Cocklin, ML 1986Spatial resolution requirements for digital chest radiographs: an ROC study of observer performance in selected cases.Radiology1581119PubMed
19.
go back to reference Goodman, LR, Foley, WD, Wilson, DR, Rimm, AA, Lawson, TL 1986Digital and conventional chest images: observer performance with film digital radiography system.Radiology1582733PubMed Goodman, LR, Foley, WD, Wilson, DR, Rimm, AA, Lawson, TL 1986Digital and conventional chest images: observer performance with film digital radiography system.Radiology1582733PubMed
20.
go back to reference Chakraborty, DP, Breatnach, ES, Yester, MV, Soto, B, Barnes, GT, Fraser, R 1986Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules.Radiology1583539PubMed Chakraborty, DP, Breatnach, ES, Yester, MV, Soto, B, Barnes, GT, Fraser, R 1986Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules.Radiology1583539PubMed
21.
go back to reference Niklason, LT, Hickey, NM, Chakraborty, DP, et al. 1986Simulated pulmonary nodules: detection with dual energy digital versus conventional radiography.Radiology160589593PubMed Niklason, LT, Hickey, NM, Chakraborty, DP,  et al. 1986Simulated pulmonary nodules: detection with dual energy digital versus conventional radiography.Radiology160589593PubMed
22.
go back to reference Kushner, DC, Cleveland, RH, Herman, TE, et al. 1987Low-dose flying spot digital radiography of the chest: sensitivity studies.Radiology163685688PubMed Kushner, DC, Cleveland, RH, Herman, TE,  et al. 1987Low-dose flying spot digital radiography of the chest: sensitivity studies.Radiology163685688PubMed
23.
go back to reference Barnes, GT, Sabbagh, EA, Chakraborty, DP, et al. 1989A comparison of dual-energy digital radiography and screen-film imaging in the detection of subtle interstitial pulmonary disease.Invest Radiol24585591PubMed Barnes, GT, Sabbagh, EA, Chakraborty, DP,  et al. 1989A comparison of dual-energy digital radiography and screen-film imaging in the detection of subtle interstitial pulmonary disease.Invest Radiol24585591PubMed
24.
go back to reference Chan, H, Vyborny, CJ, MacMahon, H, Metz, CE, Doi, K, Sickles, EA 1987Digital mammography ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications.Invest Radiol22581589PubMed Chan, H, Vyborny, CJ, MacMahon, H, Metz, CE, Doi, K, Sickles, EA 1987Digital mammography ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications.Invest Radiol22581589PubMed
25.
go back to reference Oestmann, JW, Kopans, D, Hall, DA, McCarthy, KA, Rubens, JR, Greene, R 1988A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications.Invest Radiol23726723 Oestmann, JW, Kopans, D, Hall, DA, McCarthy, KA, Rubens, JR, Greene, R 1988A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications.Invest Radiol23726723
26.
go back to reference Seeley, GW, Stempski, M, Roehrig, H, Nudelman, S, Capp, MP October 1982Psychophysical comparison of a video display system to film by using bone fracture images. Presented at the First International Symposium on Medical Imaging and Image Interpretation.Federal Republic of GermanyBerlin Seeley, GW, Stempski, M, Roehrig, H, Nudelman, S, Capp, MP October 1982Psychophysical comparison of a video display system to film by using bone fracture images. Presented at the First International Symposium on Medical Imaging and Image Interpretation.Federal Republic of GermanyBerlin
27.
go back to reference Murphey, MD 1989Digital skeletal radiography: spatial resolution requirements for detection of subperiosteal resorption.AJR152541546 Murphey, MD 1989Digital skeletal radiography: spatial resolution requirements for detection of subperiosteal resorption.AJR152541546
28.
go back to reference Kastan, DJ, Ackerman, LV, Feczko, PJ 1987Digital gastrointestinal imaging: the effect of pixel size on detection of subtle mucosal abnormalities.Radiology167853856 Kastan, DJ, Ackerman, LV, Feczko, PJ 1987Digital gastrointestinal imaging: the effect of pixel size on detection of subtle mucosal abnormalities.Radiology167853856
29.
go back to reference Fajardo, LL, Hillman, BJ, Hunter, TB, Claypool, HR, Westerman, BR, Mockbee, B 1987Excretory urography using computed radiography.Radiology162345351PubMed Fajardo, LL, Hillman, BJ, Hunter, TB, Claypool, HR, Westerman, BR, Mockbee, B 1987Excretory urography using computed radiography.Radiology162345351PubMed
30.
go back to reference Rose, A 1973Vision, human and electronic.PlenumNew York Rose, A 1973Vision, human and electronic.PlenumNew York
31.
go back to reference Kruger, RA, Mistretta, CA, Riederer, SJ 1981Physical and technical considerations of computerized fluoroscopy difference imaging.IEEE Trans Nucl SciNS28205212 Kruger, RA, Mistretta, CA, Riederer, SJ 1981Physical and technical considerations of computerized fluoroscopy difference imaging.IEEE Trans Nucl SciNS28205212
32.
go back to reference Rimkus, D, Baily, NA 1984Patient exposure requirements for high contrast resolution in digital radiographic systems.AJR142603608 Rimkus, D, Baily, NA 1984Patient exposure requirements for high contrast resolution in digital radiographic systems.AJR142603608
33.
go back to reference Tannas, LE 1985Flat-panel displays and CRTs.Van Nostrand ReinholdNew York Tannas, LE 1985Flat-panel displays and CRTs.Van Nostrand ReinholdNew York
34.
go back to reference Suddarth, SA, Johnson, GA, Sherrier, RH, Ravin, CE 1987Performance of high-resolution monitors for digital chest imaging.Med Phys14253257CrossRefPubMed Suddarth, SA, Johnson, GA, Sherrier, RH, Ravin, CE 1987Performance of high-resolution monitors for digital chest imaging.Med Phys14253257CrossRefPubMed
35.
go back to reference Johnston RE: Display monitors. Presented at the American Association of Physicists in Medicine Summer School in Image Communication and Image Analysis, Ann Arbor, Mien, July 12-17, 1987 Johnston RE: Display monitors. Presented at the American Association of Physicists in Medicine Summer School in Image Communication and Image Analysis, Ann Arbor, Mien, July 12-17, 1987
36.
go back to reference O’Malley, KG, Giunta, JA 1988The alternator: determination of its fundamental features, as a basis for design of a PACS.SPIE Med Imaging II914988994 O’Malley, KG, Giunta, JA 1988The alternator: determination of its fundamental features, as a basis for design of a PACS.SPIE Med Imaging II914988994
37.
go back to reference Kasaday, LR 1986Human factor considerations in PACS design.SPIE Med XIV PACS IV626581592 Kasaday, LR 1986Human factor considerations in PACS design.SPIE Med XIV PACS IV626581592
38.
go back to reference Rogers, DC, Johnston, RE, Brenton, B, Staab, EV, Thomson, B, Perry, JR 1985Predicting PACS console requirements from radiologists’ reading habits.SPIE PACS III5368896 Rogers, DC, Johnston, RE, Brenton, B, Staab, EV, Thomson, B, Perry, JR 1985Predicting PACS console requirements from radiologists’ reading habits.SPIE PACS III5368896
39.
go back to reference Beard, D, Pizer, S, Rogers, D, Cromartie, R 1987A prototype single-screen PACS console development using human computer interaction techniques.SPIE Med Imaging767646653 Beard, D, Pizer, S, Rogers, D, Cromartie, R 1987A prototype single-screen PACS console development using human computer interaction techniques.SPIE Med Imaging767646653
40.
go back to reference Johnston RE, Beard DV, Creasy JL, Perry JR: UNC PACS II: consoles. Presented at the Ninth Conference on Computer Applications in Radiology, Hilton Head, SC, June 1-4, 1988 Johnston RE, Beard DV, Creasy JL, Perry JR: UNC PACS II: consoles. Presented at the Ninth Conference on Computer Applications in Radiology, Hilton Head, SC, June 1-4, 1988
41.
go back to reference Lo, SB, Mun, SK, Braudes, RE, Levine, BA 1989A workstation for rapid image presentation.SPIE Med ImagingIII10931098 Lo, SB, Mun, SK, Braudes, RE, Levine, BA 1989A workstation for rapid image presentation.SPIE Med ImagingIII10931098
42.
go back to reference Human Factors Society1988American national standards for human factors engineering of visual display terminal workstations.Human Factors SocietySanta Monica, Calif Human Factors Society1988American national standards for human factors engineering of visual display terminal workstations.Human Factors SocietySanta Monica, Calif
43.
go back to reference van der Voorde, F, Arenson, RL, Kundel, HL, et al. 1986Development of a physician friendly digital image display console.PACS IV626541548 van der Voorde, F, Arenson, RL, Kundel, HL,  et al. 1986Development of a physician friendly digital image display console.PACS IV626541548
44.
go back to reference Alter, AJ, Kargas, GA, Kargas, SA, et al. 1982The influence of ambient and viewbox light upon visual detection of low-contrast targets in a radiograph.Invest Radiol17402406PubMed Alter, AJ, Kargas, GA, Kargas, SA,  et al. 1982The influence of ambient and viewbox light upon visual detection of low-contrast targets in a radiograph.Invest Radiol17402406PubMed
45.
go back to reference Rogers, DC, Johnston, RE 1987Effect of ambient light on electronically displayed medical images as measured by luminance-discrimination thresholds.J Opt Soc Am [A]4976983 Rogers, DC, Johnston, RE 1987Effect of ambient light on electronically displayed medical images as measured by luminance-discrimination thresholds.J Opt Soc Am [A]4976983
46.
go back to reference Seshadri, SB, Arenson, RL, Khalsa, SS, Brikman, IS, van der Voorde, F 1987Prototype image management system (MIMS) at the University of Pennsylvania: software design considerations.SPIE Med Imaging767793800 Seshadri, SB, Arenson, RL, Khalsa, SS, Brikman, IS, van der Voorde, F 1987Prototype image management system (MIMS) at the University of Pennsylvania: software design considerations.SPIE Med Imaging767793800
47.
go back to reference Haynor, DR, Saarinen, AO 1989“Old study” and the correlative study: implications for PACS.SPIE Med Imaging III10931012 Haynor, DR, Saarinen, AO 1989“Old study” and the correlative study: implications for PACS.SPIE Med Imaging III10931012
48.
go back to reference Cox, GG, Templeton, AW, Anderson, WH, Cook, LT, Hensley, KS, Dwyer, SJ 1986Estimating digital information throughput rates for radiology networks.Invest Radiol21162169PubMed Cox, GG, Templeton, AW, Anderson, WH, Cook, LT, Hensley, KS, Dwyer, SJ 1986Estimating digital information throughput rates for radiology networks.Invest Radiol21162169PubMed
49.
go back to reference Arenson, RL, Seshadri, SB, Stevens, F, van der Voorde, F 1987The overlapping domains and interface between radiology information management systems and medical image management systems (PACS).Proceedings of computer assisted radiology.Springer-VerlagBerlin855865 Arenson, RL, Seshadri, SB, Stevens, F, van der Voorde, F 1987The overlapping domains and interface between radiology information management systems and medical image management systems (PACS).Proceedings of computer assisted radiology.Springer-VerlagBerlin855865
50.
go back to reference Arenson, RL, Seshadri, SB, Kundel, HL, et al. 1988Clinical evaluation of a medical image management system for chest images.AJR1505559 Arenson, RL, Seshadri, SB, Kundel, HL,  et al. 1988Clinical evaluation of a medical image management system for chest images.AJR1505559
51.
go back to reference Gershon-Cohen, J, Fisher, JF 1959Television contrast expansion of single roentgenograms.AJR81325327 Gershon-Cohen, J, Fisher, JF 1959Television contrast expansion of single roentgenograms.AJR81325327
52.
go back to reference Meyers, PH, Becker, HC, Sweeney, JW, Nice, C, Nettleton, WJ 1963Evaluation of a computer retrieved radiographic image.Radiology2018385 Meyers, PH, Becker, HC, Sweeney, JW, Nice, C, Nettleton, WJ 1963Evaluation of a computer retrieved radiographic image.Radiology2018385
53.
go back to reference Nathan, R 1968Picture enhancement for the moon, Mars, and man.Cheng, GCLedley, RSPollock, DKRosenfeld, A eds. Pictorial pattern recognition.ThomsonWashington, DC239266 Nathan, R 1968Picture enhancement for the moon, Mars, and man.Cheng, GCLedley, RSPollock, DKRosenfeld, A eds. Pictorial pattern recognition.ThomsonWashington, DC239266
54.
go back to reference Kundel, HL, Revesz, G, Stauffer, HM 1969The electro-optical processing of radiographic images.Radiol Clin North Am8447460 Kundel, HL, Revesz, G, Stauffer, HM 1969The electro-optical processing of radiographic images.Radiol Clin North Am8447460
55.
go back to reference Mistretta, CA, Crummy, AB 1981Diagnosis of cardiovascular disease by digital subtraction angiography.Science214761765PubMed Mistretta, CA, Crummy, AB 1981Diagnosis of cardiovascular disease by digital subtraction angiography.Science214761765PubMed
56.
go back to reference Ishida, M, Frank, PH, Doi, K, Lehr, JL 1982High quality digital radiographic images: improved detection of low-contrast objects and preliminary clinical studies.RadioGraphics3325338 Ishida, M, Frank, PH, Doi, K, Lehr, JL 1982High quality digital radiographic images: improved detection of low-contrast objects and preliminary clinical studies.RadioGraphics3325338
57.
go back to reference Kundel, HL 1986Visual perception and image display terminals.Radiol Clin North Am246978PubMed Kundel, HL 1986Visual perception and image display terminals.Radiol Clin North Am246978PubMed
58.
go back to reference Schreiber, WF 1986Fundamentals of electronic imaging systems.Springer-VerlagBerlin Schreiber, WF 1986Fundamentals of electronic imaging systems.Springer-VerlagBerlin
59.
go back to reference Pizer, SM, Chan, FH 1980Evaluation of the number of discernible levels produced by a display.Dipaola, RKahn, E eds. Information processing in medical imaging. Proceedings of the VIth International Conference on Information Processing in Medical Imaging. Vol 88.INSERMParis Pizer, SM, Chan, FH 1980Evaluation of the number of discernible levels produced by a display.Dipaola, RKahn, E eds. Information processing in medical imaging. Proceedings of the VIth International Conference on Information Processing in Medical Imaging. Vol 88.INSERMParis
60.
go back to reference Cromartie, RC, Johnston, RE, Pizer, SM, Rogers, D 1987Standardization of electronic display devices based on human perception. University of North Carolina Department of Computer Science technical report 88-002.University of North CarolinaChapel Hill, NC Cromartie, RC, Johnston, RE, Pizer, SM, Rogers, D 1987Standardization of electronic display devices based on human perception. University of North Carolina Department of Computer Science technical report 88-002.University of North CarolinaChapel Hill, NC
61.
go back to reference Pizer, SM, Zimmerman, JB, Staab, EV 1984Adaptive grey level assignment in CT scan display.J Comput Assist Tomogr8300305PubMed Pizer, SM, Zimmerman, JB, Staab, EV 1984Adaptive grey level assignment in CT scan display.J Comput Assist Tomogr8300305PubMed
62.
go back to reference McShan, DL, Glickman, AS 1987Color displays for medical imaging in color and the computer.Durrett, HJ eds. Color and the computer.Academic PressSan Diego189204 McShan, DL, Glickman, AS 1987Color displays for medical imaging in color and the computer.Durrett, HJ eds. Color and the computer.Academic PressSan Diego189204
63.
go back to reference Chan, FH, Pizer, SM 1976An ultrasonogram display system using natural color.JCU4335338PubMed Chan, FH, Pizer, SM 1976An ultrasonogram display system using natural color.JCU4335338PubMed
64.
go back to reference Vannier, MW, Rickman, D 1989Multispectral and color-aided displays.Invest Radiol248891PubMed Vannier, MW, Rickman, D 1989Multispectral and color-aided displays.Invest Radiol248891PubMed
65.
go back to reference DeSimone, DN, Kundel, HL, Arenson, RL, et al. 1988Effect of a digital imaging network on physician behavior in an intensive care unit.Radiology1694144PubMed DeSimone, DN, Kundel, HL, Arenson, RL,  et al. 1988Effect of a digital imaging network on physician behavior in an intensive care unit.Radiology1694144PubMed
66.
go back to reference Swett, HA, Miller, PL 1987ICON: computer-based approach to differential diagnosis in radiology.Radiology163555558PubMed Swett, HA, Miller, PL 1987ICON: computer-based approach to differential diagnosis in radiology.Radiology163555558PubMed
67.
go back to reference Fischer, HW 1988Danger ahead (editorial).Radiology169267 Fischer, HW 1988Danger ahead (editorial).Radiology169267
68.
go back to reference Arenson, RL 1988Opportunity ahead (editorial response).Radiology169267268 Arenson, RL 1988Opportunity ahead (editorial response).Radiology169267268
Metadata
Title
The Digital Imaging Workstation
Authors
Ronald L. Arenson, M.D.
Dev P. Chakraborty, Ph.D.
Sridhar B. Seshadri, M.S.E.E.
Harold L. Kundel, M.D.
Publication date
01-03-2003
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 1/2003
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-002-6004-y

Other articles of this Issue 1/2003

Journal of Digital Imaging 1/2003 Go to the issue