Skip to main content
Top
Published in: Odontology 2/2024

08-11-2023 | Original Article

Influence of light exposure techniques on in vitro pulp temperature rise during bulk fill composite Class I restorations

Authors: Juliana Anany Gonzales Guarneri, Maria Victoria Arteaga Chima, Danielle Gomes Assis, Frederick Allen Rueggeberg, Cesar Augusto Galvão Arrais

Published in: Odontology | Issue 2/2024

Login to get access

Abstract

This in vitro study assessed peak temperature and temperature increase (ΔT) within the pulp chamber during different extended photoactivation techniques (EPT—applying similar radiant exposure values) to resin-based composites (RBCs) placed in a Class I cavity preparation in an extracted human lower third molar. A T-type thermocouple was placed in the pulp chamber and connected to a temperature analysis device (Thermes, Physitemp). The tooth was attached to an assembly simulating the in vivo environment (controlled baseline pulp chamber temperature and fluid flow). The real-time pulp chamber temperature was evaluated throughout the photoactivation (Bluephase N, Ivoclar Vivadent) of two bulk-fill RBCs: Tetric N Ceram Bulk Fill (TBF; shade: IVA; Ivoclar Vivadent); Surefill SDR flow + (SDR, shade: Universal; Dentsply Sirona), which were exposed to different curing techniques: 40 s-occlusal surface; 20 s-occlusal + 10 s-buccal + 10 s-lingual surfaces; 10 s-buccal + 10 s + lingual + 20 s-occlusal surfaces. Each EPT delivered 42.4 J/cm2. Vickers hardness (VHN) was measured on the removed, sectioned RBC restorations at the top and bottom middle areas after curing. ΔT and VHN data were analyzed using 2-way ANOVA followed by Bonferroni post-hoc test (α = 0.05). Peak temperature data were analyzed using one-way ANOVA and Dunnett’s post-hoc test (α = 0.05). SDR showed higher ΔT values than TBF (p = 0.008) in some EPTs. Neither technique resulted in ΔT values greater than 5.5 °C. Both composites had acceptable bottom/top hardness ratios (greater than 80%), regardless of the photoactivation technique. The evaluated EPTs may be considered safe as a low-temperature increase was noticed within the pulp chamber.
Literature
18.
go back to reference Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol. 1965:515–30. Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol. 1965:515–30.
26.
go back to reference Kim S, Dorscher-Kim JE, Liu M. Microcirculation of the dental pulp and its autonomic control. Proc Finn Dent Soc. 1989;85(4–5):279–87.PubMed Kim S, Dorscher-Kim JE, Liu M. Microcirculation of the dental pulp and its autonomic control. Proc Finn Dent Soc. 1989;85(4–5):279–87.PubMed
Metadata
Title
Influence of light exposure techniques on in vitro pulp temperature rise during bulk fill composite Class I restorations
Authors
Juliana Anany Gonzales Guarneri
Maria Victoria Arteaga Chima
Danielle Gomes Assis
Frederick Allen Rueggeberg
Cesar Augusto Galvão Arrais
Publication date
08-11-2023
Publisher
Springer Nature Singapore
Published in
Odontology / Issue 2/2024
Print ISSN: 1618-1247
Electronic ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-023-00867-0

Other articles of this Issue 2/2024

Odontology 2/2024 Go to the issue