Skip to main content
Top
Published in: Neurosurgical Review 2/2003

01-05-2003 | Review

Computer-aided navigation in neurosurgery

Authors: P. Grunert, K. Darabi, J. Espinosa, R. Filippi

Published in: Neurosurgical Review | Issue 2/2003

Login to get access

Abstract

The article comprises three main parts: a historical review on navigation, the mathematical basics for calculation and the clinical applications of navigation devices. Main historical steps are described from the first idea till the realisation of the frame-based and frameless navigation devices including robots. In particular the idea of robots can be traced back to the Iliad of Homer, the first testimony of European literature over 2500 years ago. In the second part the mathematical calculation of the mapping between the navigation and the image space is demonstrated, including different registration modalities and error estimations. The error of the navigation has to be divided into the technical error of the device calculating its own position in space, the registration error due to inaccuracies in the calculation of the transformation matrix between the navigation and the image space, and the application error caused additionally by anatomical shift of the brain structures during operation. In the third part the main clinical fields of application in modern neurosurgery are demonstrated, such as localisation of small intracranial lesions, skull-base surgery, intracerebral biopsies, intracranial endoscopy, functional neurosurgery and spinal navigation. At the end of the article some possible objections to navigation-aided surgery are discussed.
Footnotes
1
"Autos" means "self" in Greek
 
Literature
1.
go back to reference Adams L, Krybus W, Meyer-Ebrecht D, Rüger R, Gilsbach JM, Mösges R, Schlöndorff G (1990) Computer assisted surgery. IEEE Computer Graphics Appl 10:43CrossRef Adams L, Krybus W, Meyer-Ebrecht D, Rüger R, Gilsbach JM, Mösges R, Schlöndorff G (1990) Computer assisted surgery. IEEE Computer Graphics Appl 10:43CrossRef
2.
go back to reference Albert TJ, Klein GR, Vaccaro AR (1999) Image-guided anterior cervical corpectomy. A feasible study. Spine 15:826–830CrossRef Albert TJ, Klein GR, Vaccaro AR (1999) Image-guided anterior cervical corpectomy. A feasible study. Spine 15:826–830CrossRef
3.
go back to reference Alberti O, Dorward NL, Kitchen ND, Thomas DGT (1997) Neuronavigation—impact on operating time. Stereotact Funct Neurosurg 68:44–48PubMed Alberti O, Dorward NL, Kitchen ND, Thomas DGT (1997) Neuronavigation—impact on operating time. Stereotact Funct Neurosurg 68:44–48PubMed
4.
go back to reference Alexander E III, Moriarty TM, Kikinis R, Black P, Jolesz FM (1997) The present and future role of intraoperative MRI in neurosurgical procedures. Stereotact Funct Neurosurg 68:10–17PubMed Alexander E III, Moriarty TM, Kikinis R, Black P, Jolesz FM (1997) The present and future role of intraoperative MRI in neurosurgical procedures. Stereotact Funct Neurosurg 68:10–17PubMed
5.
go back to reference Altuchow NW (1891) Encephalometric investigation of brain in connection with sex, age and cranium size. Publisher unknown, Moscow Altuchow NW (1891) Encephalometric investigation of brain in connection with sex, age and cranium size. Publisher unknown, Moscow
6.
go back to reference Apuzzo ML, Chen JC (1999) Stereotaxy, navigation and the temporal concatenation. Stereotact Funct Neurosurg 72:82–88PubMed Apuzzo ML, Chen JC (1999) Stereotaxy, navigation and the temporal concatenation. Stereotact Funct Neurosurg 72:82–88PubMed
7.
go back to reference Apuzzo Ml, Sabshin JK (1983) Computed tomographic guidance stereotaxis in the management of the intracranial mass lesions. Neurosurgery 12:277–284PubMed Apuzzo Ml, Sabshin JK (1983) Computed tomographic guidance stereotaxis in the management of the intracranial mass lesions. Neurosurgery 12:277–284PubMed
8.
go back to reference Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Intraoperative localization using an armless, frameless stereotactic wand. J Neurosurg 78:510–514PubMed Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Intraoperative localization using an armless, frameless stereotactic wand. J Neurosurg 78:510–514PubMed
9.
go back to reference Barnett GH, Miller DW (1998) Brain biopsy and related procedures. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 181–191 Barnett GH, Miller DW (1998) Brain biopsy and related procedures. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 181–191
10.
go back to reference Barnett GH (1996) Surgical management of convexity and falcine meningeomas using interactive image-guided surgery systems. Neurosurg Clin N Am 7:279–284PubMed Barnett GH (1996) Surgical management of convexity and falcine meningeomas using interactive image-guided surgery systems. Neurosurg Clin N Am 7:279–284PubMed
11.
go back to reference Barnett GH, Steiner CP, Roberts DW (1998) Surgical navigation system technologies. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 17–32 Barnett GH, Steiner CP, Roberts DW (1998) Surgical navigation system technologies. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 17–32
12.
go back to reference Belliveau JW, Kennedy DN, McKinstry RC (1991) Functional mapping of the human visual cortex by magnetic resonance imaging. Science 254:716–719PubMed Belliveau JW, Kennedy DN, McKinstry RC (1991) Functional mapping of the human visual cortex by magnetic resonance imaging. Science 254:716–719PubMed
13.
go back to reference Benabid A, Lavallee S, Hoffmann D, Cinquin P, Demongeot J, Danel F (1992) Computer-driven robot for stereotactic neurosurgery. Computers in stereotactic surgery. Blackwell Scientific, Boston, pp 330–342 Benabid A, Lavallee S, Hoffmann D, Cinquin P, Demongeot J, Danel F (1992) Computer-driven robot for stereotactic neurosurgery. Computers in stereotactic surgery. Blackwell Scientific, Boston, pp 330–342
14.
go back to reference Bingaman WE, Barnett GH (1998) Social and economic impact of surgical navigation systems. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided surgery. Quality Medical, St. Louis, pp 231–249 Bingaman WE, Barnett GH (1998) Social and economic impact of surgical navigation systems. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided surgery. Quality Medical, St. Louis, pp 231–249
15.
go back to reference Boecher-Schwarz HG, Grunert P, Guenthner M, Kessel G, Mueller-Forell W (1996) Stereotactically guided cavernous malformation surgery. Minim Invas Neurosurg 39:50–55 Boecher-Schwarz HG, Grunert P, Guenthner M, Kessel G, Mueller-Forell W (1996) Stereotactically guided cavernous malformation surgery. Minim Invas Neurosurg 39:50–55
16.
go back to reference Bolger C, Wigfield C, Melkent T, Smith K (1999) Frameless stereotaxy and anterior cervical surgery. Comput Aided Surg 4:322–327PubMed Bolger C, Wigfield C, Melkent T, Smith K (1999) Frameless stereotaxy and anterior cervical surgery. Comput Aided Surg 4:322–327PubMed
17.
go back to reference Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and review of the first 120 procedures. J Neurosurg 92:175–180PubMed Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and review of the first 120 procedures. J Neurosurg 92:175–180PubMed
18.
go back to reference Boroojerdi B, Folys H, Krings T, Spetzger U, Thron A, Topper R (1999) Localization of the motor hand area using transcranial magnetic stimulation and functional magnetic resonance imaging. Clin Neurophysiol 110:699–704PubMed Boroojerdi B, Folys H, Krings T, Spetzger U, Thron A, Topper R (1999) Localization of the motor hand area using transcranial magnetic stimulation and functional magnetic resonance imaging. Clin Neurophysiol 110:699–704PubMed
19.
go back to reference Brinker T, Arango G, Kaminsky S, Samii A, Thorns U, Vorkapic P, Samii M (1998) An experimental approach to image guided skull base surgery employing a microscope based neuronavigation system. Acta Neurochir (Wien) 140:883–889 Brinker T, Arango G, Kaminsky S, Samii A, Thorns U, Vorkapic P, Samii M (1998) An experimental approach to image guided skull base surgery employing a microscope based neuronavigation system. Acta Neurochir (Wien) 140:883–889
20.
go back to reference Brommeland T, Henning R (2000) A new procedure for frameless computer navigated stereotaxy. Acta Neurochir (Wien) 142:443–447 Brommeland T, Henning R (2000) A new procedure for frameless computer navigated stereotaxy. Acta Neurochir (Wien) 142:443–447
21.
go back to reference Bucholz R, Marzouk S, Levy A (1999) Image guidance and the operating microscope: stealth and neural navigation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 345–355 Bucholz R, Marzouk S, Levy A (1999) Image guidance and the operating microscope: stealth and neural navigation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 345–355
22.
go back to reference Bucholz R, Macneil WR, Henderson J (1997) Anatomical surface contour matching for efficient registration in image guided neurosurgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 772–777 Bucholz R, Macneil WR, Henderson J (1997) Anatomical surface contour matching for efficient registration in image guided neurosurgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 772–777
23.
go back to reference Capek K (1931) Rossum's universal robots [Czech]. Aventinum Praha X. Vydani Capek K (1931) Rossum's universal robots [Czech]. Aventinum Praha X. Vydani
24.
go back to reference Carl AL, Khanuja HS, Sachs BL, Gatto CA, vom Lehm S, Vosburg K, Schenck J (1997) In vitro simulation. Early results of stereotaxy for pedicle screw placement. Spine 22:1160–1164PubMed Carl AL, Khanuja HS, Sachs BL, Gatto CA, vom Lehm S, Vosburg K, Schenck J (1997) In vitro simulation. Early results of stereotaxy for pedicle screw placement. Spine 22:1160–1164PubMed
25.
go back to reference Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vom Lehm J, Schenck J, Rohling K, Lorensen W, Vosburg K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13:225–229PubMed Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vom Lehm J, Schenck J, Rohling K, Lorensen W, Vosburg K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13:225–229PubMed
26.
go back to reference Carrau RL, Snyderman CH, Curin HD, Janecka IP, Stechison M, Weissman JL (1996) Computer-assisted intraoperative navigation during skull base surgery. Am J Otolaryng 17:95–101 Carrau RL, Snyderman CH, Curin HD, Janecka IP, Stechison M, Weissman JL (1996) Computer-assisted intraoperative navigation during skull base surgery. Am J Otolaryng 17:95–101
27.
go back to reference Clarke R (1906) On a method of investigating the deep ganglia and tracts of the central nervous system. Br Med J 2:1799–1800 Clarke R (1906) On a method of investigating the deep ganglia and tracts of the central nervous system. Br Med J 2:1799–1800
28.
go back to reference Cormack AM (1963) Representation of a function by its line integrals, with some radiological applications. J Appl Phys 34:2722–2727 Cormack AM (1963) Representation of a function by its line integrals, with some radiological applications. J Appl Phys 34:2722–2727
29.
go back to reference Cormack AM (1964) Representation of a function by its line integrals with some radiological applications II. J Appl Phys 35:195–207 Cormack AM (1964) Representation of a function by its line integrals with some radiological applications II. J Appl Phys 35:195–207
30.
go back to reference Coste E, Rousseau J, Gibon D, Deleume JF, Blond S, Marchandise X (1993) Frameless method of stereotactic localization with DSA. Neuroradiology 189:829–834 Coste E, Rousseau J, Gibon D, Deleume JF, Blond S, Marchandise X (1993) Frameless method of stereotactic localization with DSA. Neuroradiology 189:829–834
31.
go back to reference Cosgrove GR, Buchbinder BR, Jiang H (1999) Functional magnetic resonance imaging for planning cortical resections. Thieme, New York, pp 201–207 Cosgrove GR, Buchbinder BR, Jiang H (1999) Functional magnetic resonance imaging for planning cortical resections. Thieme, New York, pp 201–207
32.
go back to reference Cushing H (1909) A note on the faradic stimulation of the postcentral gyrus in conscious patients. Brain 32:44–53 Cushing H (1909) A note on the faradic stimulation of the postcentral gyrus in conscious patients. Brain 32:44–53
33.
go back to reference Dandy WE (1918) Ventriculography following the injection of air into the cerebral ventricles. Ann Surg 68:5–12 Dandy WE (1918) Ventriculography following the injection of air into the cerebral ventricles. Ann Surg 68:5–12
34.
go back to reference Darabi K, Grunert P, Perneczky A (1997) Accuracy of intraoperative navigation using skin markers. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 920–924 Darabi K, Grunert P, Perneczky A (1997) Accuracy of intraoperative navigation using skin markers. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 920–924
35.
go back to reference David NE (1999) Ergebnisse der rahmenbasierten und rahmenlosen intraoperativen Lokalisation von Gehirnprozessen unter besonderer Berücksichtigung des klinischen Outcomes. Inaugural Dissertation, Mainz David NE (1999) Ergebnisse der rahmenbasierten und rahmenlosen intraoperativen Lokalisation von Gehirnprozessen unter besonderer Berücksichtigung des klinischen Outcomes. Inaugural Dissertation, Mainz
36.
go back to reference Dean D, Kamath J, Duerk JL, Ganz E (1998) Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery. IEEE Trans Med Imaging 17:810–816CrossRefPubMed Dean D, Kamath J, Duerk JL, Ganz E (1998) Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery. IEEE Trans Med Imaging 17:810–816CrossRefPubMed
37.
go back to reference Denavit J, Hartenberg RS (1955) A kinematic notation for lower-pair mechanisms based on matrices. ASME J Appl Mechanics 22:215–221 Denavit J, Hartenberg RS (1955) A kinematic notation for lower-pair mechanisms based on matrices. ASME J Appl Mechanics 22:215–221
38.
go back to reference Descartes R (1984) Passions de l'âme. Meiner, Hamburg Descartes R (1984) Passions de l'âme. Meiner, Hamburg
39.
go back to reference Dorward NL, Alberti O, Zhao J, Dijkstra A, Buurman J, Palmer JD, Hawkes D, Thomas DGT (1998) Interactive image-guided neuroendoscopy: development and early clinical experience. Minim Invasive Neurosurg 41:31–34PubMed Dorward NL, Alberti O, Zhao J, Dijkstra A, Buurman J, Palmer JD, Hawkes D, Thomas DGT (1998) Interactive image-guided neuroendoscopy: development and early clinical experience. Minim Invasive Neurosurg 41:31–34PubMed
40.
go back to reference Dorward NL, Alberti O, Velani B, Gertsen FA, Harkness WF, Kitchen ND, Thomas DGT (1998) Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation. J Neurosurg 88:656–662PubMed Dorward NL, Alberti O, Velani B, Gertsen FA, Harkness WF, Kitchen ND, Thomas DGT (1998) Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation. J Neurosurg 88:656–662PubMed
41.
go back to reference Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DGT (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. J Neurosurg 90:160–168 Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DGT (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. J Neurosurg 90:160–168
42.
go back to reference Doshi PK, Lemmieux L, Fish DR, Shorvon SD, Harkness WH, Thomas DGT (1995) Frameless stereotaxy and interactive neurosurgery with the ISG viewing wand. Acta Neurochir Suppl (Wien) 64:49–53 Doshi PK, Lemmieux L, Fish DR, Shorvon SD, Harkness WH, Thomas DGT (1995) Frameless stereotaxy and interactive neurosurgery with the ISG viewing wand. Acta Neurochir Suppl (Wien) 64:49–53
43.
go back to reference Drake JM, Joy M, Goldenberg A, Kreindler D (1991) Computer-and robot-assisted resection of thalamic astrocytomas in children. Neurosurgery 29:27–33PubMed Drake JM, Joy M, Goldenberg A, Kreindler D (1991) Computer-and robot-assisted resection of thalamic astrocytomas in children. Neurosurgery 29:27–33PubMed
44.
go back to reference Drake JM, Rutka JT, Hoffmann HJ (1994) ISG viewing wand. Neurosurgery 34:1094–1097 Drake JM, Rutka JT, Hoffmann HJ (1994) ISG viewing wand. Neurosurgery 34:1094–1097
45.
go back to reference Drake JM, Prudencio J, Holowaka S, Rutka JT, Hoffmann HJ, Humphrey RP (1994) Frameless stereotaxy in children. Pediatr Neurosurg 20:152–159PubMed Drake JM, Prudencio J, Holowaka S, Rutka JT, Hoffmann HJ, Humphrey RP (1994) Frameless stereotaxy in children. Pediatr Neurosurg 20:152–159PubMed
46.
go back to reference Duffau H (2000) Intraoperative direct subcortical stimulation for identification of the internal capsule, combined with an image-guided stereotactic system during surgery for basal ganglia lesions. Surg Neurol 53:250–254PubMed Duffau H (2000) Intraoperative direct subcortical stimulation for identification of the internal capsule, combined with an image-guided stereotactic system during surgery for basal ganglia lesions. Surg Neurol 53:250–254PubMed
47.
go back to reference Dyer PV, Patel N, Pell GM, Cumminis B, Sandeman DR (1995) The ISG viewing wand: an application to atlanto-axial cervical surgery using the Le Fort I maxillary osteotomy. Br J Oral Maxillofac Surg 33:370–374PubMed Dyer PV, Patel N, Pell GM, Cumminis B, Sandeman DR (1995) The ISG viewing wand: an application to atlanto-axial cervical surgery using the Le Fort I maxillary osteotomy. Br J Oral Maxillofac Surg 33:370–374PubMed
48.
go back to reference Ebeling U, Hasdemir MG, Barth A (1993) Stereotaktisch geleitete Mikrochirurgie zerebraler Prozesse. Schweiz Med Wochenschr 123:1585–1590PubMed Ebeling U, Hasdemir MG, Barth A (1993) Stereotaktisch geleitete Mikrochirurgie zerebraler Prozesse. Schweiz Med Wochenschr 123:1585–1590PubMed
49.
go back to reference Ebeling U, Steinmetz H, Huang Y, Kahn T (1989) Topography and identification of the inferior precentral sulcus in MR image. AJNR 10:937–942 Ebeling U, Steinmetz H, Huang Y, Kahn T (1989) Topography and identification of the inferior precentral sulcus in MR image. AJNR 10:937–942
50.
go back to reference Elias WJ, Chadduck JB, Alden TD, Laws ER Jr (1999) Frameless stereotaxy for transsphenoidal surgery. Neurosurgery 45:271–275PubMed Elias WJ, Chadduck JB, Alden TD, Laws ER Jr (1999) Frameless stereotaxy for transsphenoidal surgery. Neurosurgery 45:271–275PubMed
51.
go back to reference Ende G, Treuer H, Boesecke R (1992) Optimization and evaluation of landmark-based image correlation. Phys Med Biol 37:261–271CrossRefPubMed Ende G, Treuer H, Boesecke R (1992) Optimization and evaluation of landmark-based image correlation. Phys Med Biol 37:261–271CrossRefPubMed
52.
go back to reference El Jamel MS (1997) Accuracy, efficacy, and clinical applications of the radionics operating arm system. Comput Aid Surg 2:292–297CrossRef El Jamel MS (1997) Accuracy, efficacy, and clinical applications of the radionics operating arm system. Comput Aid Surg 2:292–297CrossRef
53.
go back to reference Ettinger GJ, Grimson WEL, Leventon ME (1996) Noninvasive functional brain mapping using registered transcranial magnetic stimulation. Proceedings of the IEEE workshop on mathematical methods in biomedical image analysis, San Francisco, pp 21–22 Ettinger GJ, Grimson WEL, Leventon ME (1996) Noninvasive functional brain mapping using registered transcranial magnetic stimulation. Proceedings of the IEEE workshop on mathematical methods in biomedical image analysis, San Francisco, pp 21–22
54.
go back to reference Fleig OJ, Edwards PJ, Chandra S, Süttler H, Hawkes DJ (1998) Automated microscope calibration for image guided surgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 747–752 Fleig OJ, Edwards PJ, Chandra S, Süttler H, Hawkes DJ (1998) Automated microscope calibration for image guided surgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 747–752
55.
go back to reference Forstad H, Hariz M, Ljunggren B (1991) History of Clare's stereotactic instrument. Stereotact Funct Neurosurg 57:130–140PubMed Forstad H, Hariz M, Ljunggren B (1991) History of Clare's stereotactic instrument. Stereotact Funct Neurosurg 57:130–140PubMed
56.
go back to reference Fankhauser H, Glauser D, Flury P, Piguet Y, Epitaux M, Favre J, Meuli RA (1994) Robot for CT-guided stereotactic neurosurgery. Stereotact Funct Neurosurg 63:93–98PubMed Fankhauser H, Glauser D, Flury P, Piguet Y, Epitaux M, Favre J, Meuli RA (1994) Robot for CT-guided stereotactic neurosurgery. Stereotact Funct Neurosurg 63:93–98PubMed
57.
go back to reference Fries G, Perneczky A (1999) Intracranial endoscopy. In: Cohadon F (ed) Advances and technical standards in neurosurgery, vol 25. Springer, Vienna, pp 21–60 Fries G, Perneczky A (1999) Intracranial endoscopy. In: Cohadon F (ed) Advances and technical standards in neurosurgery, vol 25. Springer, Vienna, pp 21–60
58.
go back to reference Friets EM, Strobehn JW, Hatch JF, Roberts DW (1989) A frameless stereotactic operating microscope for neurosurgery. IEEE Trans Biomed Eng 36:608–617CrossRefPubMed Friets EM, Strobehn JW, Hatch JF, Roberts DW (1989) A frameless stereotactic operating microscope for neurosurgery. IEEE Trans Biomed Eng 36:608–617CrossRefPubMed
59.
go back to reference Gallen CC, Tecoma E, Iragui V, Sobel DF, Schwartz BJ, Bloom FE (1997) Magnetic source imaging of abnormal low frequency magnetic activity in presurgical evaluation of epilepsy. Epilepsia 38:452–460PubMed Gallen CC, Tecoma E, Iragui V, Sobel DF, Schwartz BJ, Bloom FE (1997) Magnetic source imaging of abnormal low frequency magnetic activity in presurgical evaluation of epilepsy. Epilepsia 38:452–460PubMed
60.
go back to reference Gallen CC, Schwartz BJ, Bucholz RD, Malik G, Barkley GL, Smith J, Tung H, Copeland B, Bruno L, Assam S, Hirschkoff E, Bloom F (1995) Presurgical localization of functional cortex using magnetic source imaging. J Neurosurg 82:988–994PubMed Gallen CC, Schwartz BJ, Bucholz RD, Malik G, Barkley GL, Smith J, Tung H, Copeland B, Bruno L, Assam S, Hirschkoff E, Bloom F (1995) Presurgical localization of functional cortex using magnetic source imaging. J Neurosurg 82:988–994PubMed
61.
go back to reference Galloway RL, Maciunas RJ, Edwards CA (1992) Interactive image-guided neurosurgery. IEEE Trans Biomed Eng 39:1226–1231CrossRefPubMed Galloway RL, Maciunas RJ, Edwards CA (1992) Interactive image-guided neurosurgery. IEEE Trans Biomed Eng 39:1226–1231CrossRefPubMed
62.
go back to reference Germano IM, Queenan JV (1998) Clinical experience with intracranial needle biopsy using frameless surgical navigation. Comput Aided Surg 3:33–39CrossRefPubMed Germano IM, Queenan JV (1998) Clinical experience with intracranial needle biopsy using frameless surgical navigation. Comput Aided Surg 3:33–39CrossRefPubMed
63.
go back to reference Germano IM, Villalobos H, Silvers A, Post KD (1999) Clinical use of the optical digitizer for intracranial neuronavigation. Neurosurgery 45:261–269PubMed Germano IM, Villalobos H, Silvers A, Post KD (1999) Clinical use of the optical digitizer for intracranial neuronavigation. Neurosurgery 45:261–269PubMed
64.
go back to reference Gildenberg PL (1997) The history of stereotactic and functional neurosurgery. In: Gildenberg PL, Tasker RR (eds) Textbook of stereotactic and functional neurosurgery. McGraw-Hill, New York, pp 1–15 Gildenberg PL (1997) The history of stereotactic and functional neurosurgery. In: Gildenberg PL, Tasker RR (eds) Textbook of stereotactic and functional neurosurgery. McGraw-Hill, New York, pp 1–15
65.
go back to reference Giorgi C, Eisenberg H, Costi G, Gallo E, Garibotto G, Casolino D (1995) A robot assisted microscope for neurosurgery. Proceedings of MRCAS, pp 334–339 Giorgi C, Eisenberg H, Costi G, Gallo E, Garibotto G, Casolino D (1995) A robot assisted microscope for neurosurgery. Proceedings of MRCAS, pp 334–339
66.
go back to reference Giorgi C, Casolino DS (1997) Preliminary clinical experience with intraoperative stereotactic ultrasound imaging. Stereotact Funct Neurosurg 68:54–58PubMed Giorgi C, Casolino DS (1997) Preliminary clinical experience with intraoperative stereotactic ultrasound imaging. Stereotact Funct Neurosurg 68:54–58PubMed
67.
go back to reference Glauser D, Fankhauser H, Epitaux M, Hefti JL, Jaccottet A (1995) Neurosurgical robot minerva: first results and current developments. J Image Guid Surg 1:266–272CrossRefPubMed Glauser D, Fankhauser H, Epitaux M, Hefti JL, Jaccottet A (1995) Neurosurgical robot minerva: first results and current developments. J Image Guid Surg 1:266–272CrossRefPubMed
68.
go back to reference Glossop N, Hu R (1997) Effect of registration method on clinical accuracy of image guided pedicle screw surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 884–888 Glossop N, Hu R (1997) Effect of registration method on clinical accuracy of image guided pedicle screw surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 884–888
69.
go back to reference Glossop N, Hu R (1997) Clinical use accuracy in image guided surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 889–893 Glossop N, Hu R (1997) Clinical use accuracy in image guided surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 889–893
70.
go back to reference Goertz RC (1963) Manipulators used for handling radioactive materials. In: Benett EM (ed) Human factors in technology. McGraw-Hill, New York Goertz RC (1963) Manipulators used for handling radioactive materials. In: Benett EM (ed) Human factors in technology. McGraw-Hill, New York
71.
go back to reference Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1996) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 83:287–292 Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1996) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 83:287–292
72.
go back to reference Grimson WEL, Ettinger GJ, White SJ, Lozano-Perez T, Wells WM III, Kikinis R (1996) An automatic registration method for frameless stereotaxy, image guided surgery and enhanced reality visualization. IEEE Trans Med Imaging 5:129–140CrossRef Grimson WEL, Ettinger GJ, White SJ, Lozano-Perez T, Wells WM III, Kikinis R (1996) An automatic registration method for frameless stereotaxy, image guided surgery and enhanced reality visualization. IEEE Trans Med Imaging 5:129–140CrossRef
73.
go back to reference Grunert P, Hopf N, Perneczky A (1997) Framebased and frameless endoscopic procedures in the third ventricle. Stereotact Funct Neurosurg 68:80–89PubMed Grunert P, Hopf N, Perneczky A (1997) Framebased and frameless endoscopic procedures in the third ventricle. Stereotact Funct Neurosurg 68:80–89PubMed
74.
go back to reference Grunert P, Mueller-Forell W, Darabi K, Reisch R, Busert C, Hopf N, Perneczky A (1998) Basic principles and clinical applications of neuronavigation and intraoperative computed tomography. Comput Aid Surg 3:166–173 Grunert P, Mueller-Forell W, Darabi K, Reisch R, Busert C, Hopf N, Perneczky A (1998) Basic principles and clinical applications of neuronavigation and intraoperative computed tomography. Comput Aid Surg 3:166–173
75.
go back to reference Grunert P, Mäurer J, Müller-Forell W (1999) Accuracy of stereotactic coordinate transformation using a localization frame and computed tomographic imaging. Part I. Influence of the mathematical and physical properties of the CT on the image of the rods of the localization frame and the determination of their centres. Neurosurg Rev 22:173–187PubMed Grunert P, Mäurer J, Müller-Forell W (1999) Accuracy of stereotactic coordinate transformation using a localization frame and computed tomographic imaging. Part I. Influence of the mathematical and physical properties of the CT on the image of the rods of the localization frame and the determination of their centres. Neurosurg Rev 22:173–187PubMed
76.
go back to reference Grunert P (1999) Accuracy of stereotactic coordinate transformation using a localization frame and computed tomographic imaging. Part II. Analysis of matrix-based coordinate transformation. Neurosurg Rev 22:188–203PubMed Grunert P (1999) Accuracy of stereotactic coordinate transformation using a localization frame and computed tomographic imaging. Part II. Analysis of matrix-based coordinate transformation. Neurosurg Rev 22:188–203PubMed
77.
go back to reference Grunert P, Perneczky A, Resch K (1994) Endoscopic procedures through the foramen of Monro under stereotactic conditions. Minim Invas Neurosurg 37:2–8 Grunert P, Perneczky A, Resch K (1994) Endoscopic procedures through the foramen of Monro under stereotactic conditions. Minim Invas Neurosurg 37:2–8
78.
go back to reference Gugino LD, Potts GF, Aglio LS, Alexander E III, Grimson WEL, Kikinis R, Shenton M, Black P, Ettinger GJ, Coste WA, Leventon M, Gonzalez AA (1999) Localization of eloquent cortex using transcranial magnetic stimulation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 163–199 Gugino LD, Potts GF, Aglio LS, Alexander E III, Grimson WEL, Kikinis R, Shenton M, Black P, Ettinger GJ, Coste WA, Leventon M, Gonzalez AA (1999) Localization of eloquent cortex using transcranial magnetic stimulation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 163–199
79.
go back to reference Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab vectorvision neuronavigation system: technology and clinical experience in 131 cases. Neurosurgery 44:97–104PubMed Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab vectorvision neuronavigation system: technology and clinical experience in 131 cases. Neurosurgery 44:97–104PubMed
80.
go back to reference Gunkel AR, Freysinger W, Hensler E, Auer T, Eichinger P, Auberger T, Bale RJ, Vogele M, Martin A, Thumfart WF, Lukas P (1997) Computer assisted stereotactic frameless interstitial brachytherapy. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 404–409 Gunkel AR, Freysinger W, Hensler E, Auer T, Eichinger P, Auberger T, Bale RJ, Vogele M, Martin A, Thumfart WF, Lukas P (1997) Computer assisted stereotactic frameless interstitial brachytherapy. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 404–409
81.
go back to reference Guthrie BL (1994) Graphic-interactive cranial surgery: the operating arm system. In: Pell MF, Thomas DGT (eds) Handbook of stereotaxy using the CRW apparatus. Williams and Wilkins, Baltimore, pp 193–210 Guthrie BL (1994) Graphic-interactive cranial surgery: the operating arm system. In: Pell MF, Thomas DGT (eds) Handbook of stereotaxy using the CRW apparatus. Williams and Wilkins, Baltimore, pp 193–210
82.
go back to reference Guthrie BL, Adler JR (1992) Computer-assisted preoperative planning, interactive surgery and frameless stereotaxy. Clin Neurosurg 38:112–131PubMed Guthrie BL, Adler JR (1992) Computer-assisted preoperative planning, interactive surgery and frameless stereotaxy. Clin Neurosurg 38:112–131PubMed
83.
go back to reference Guthrie BL (1998) Cerebral metastatic disease. In: Roberts DW, Barnet GH, Maciunas RJ (eds) Image guided neurosurgery. Quality Medical, St. Louis, pp 73–76 Guthrie BL (1998) Cerebral metastatic disease. In: Roberts DW, Barnet GH, Maciunas RJ (eds) Image guided neurosurgery. Quality Medical, St. Louis, pp 73–76
84.
go back to reference Haase J (1999) Image-guided neurosurgery/neuronavigation/the surgiscope. Reflections on a theme. Minim Invasive Neurosurg 42:53–59PubMed Haase J (1999) Image-guided neurosurgery/neuronavigation/the surgiscope. Reflections on a theme. Minim Invasive Neurosurg 42:53–59PubMed
85.
86.
go back to reference Hamadeh A, Lavallee S, Cinquin P (1998) Automated 3-dimensional computed tomographic and fluoroscopic image registration. Comput Aided Surg 3:11–19PubMed Hamadeh A, Lavallee S, Cinquin P (1998) Automated 3-dimensional computed tomographic and fluoroscopic image registration. Comput Aided Surg 3:11–19PubMed
87.
go back to reference Hamilton R, Sweeney P, Pelizzari C, Yetkin F, Holman B, Garada B, Weichselbaum R, Chen G (1997) Functional imaging in treatment planning of brain lesions. Int J Radiol Oncol Biol Phys 37:181–188 Hamilton R, Sweeney P, Pelizzari C, Yetkin F, Holman B, Garada B, Weichselbaum R, Chen G (1997) Functional imaging in treatment planning of brain lesions. Int J Radiol Oncol Biol Phys 37:181–188
88.
go back to reference Hardenack M, Bucher N, Falk A, Harders A (1998) Preoperative and intraoperative navigation: status quo and perspectives. Comput Aided Surg 3:153–158PubMed Hardenack M, Bucher N, Falk A, Harders A (1998) Preoperative and intraoperative navigation: status quo and perspectives. Comput Aided Surg 3:153–158PubMed
89.
go back to reference Hassfeld S, Zoller J, Albert FK, Wirtz CR, Knauth M, Muhling J (1998) Preoperative planning and intraoperative navigation in skullbase surgery. J Craniomaxillofac Surg 26:220–225PubMed Hassfeld S, Zoller J, Albert FK, Wirtz CR, Knauth M, Muhling J (1998) Preoperative planning and intraoperative navigation in skullbase surgery. J Craniomaxillofac Surg 26:220–225PubMed
90.
go back to reference Hata N, Dohi T, Iseki H, Takakura K (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration. Neurosurgery 41:608–613PubMed Hata N, Dohi T, Iseki H, Takakura K (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration. Neurosurgery 41:608–613PubMed
91.
go back to reference Hauser R, Westermann B, Probst R (1997) Non-invasive tracking of patients' head movements during computer-assisted intranasal microscopic surgery. Laryngoscope 107:491–499PubMed Hauser R, Westermann B, Probst R (1997) Non-invasive tracking of patients' head movements during computer-assisted intranasal microscopic surgery. Laryngoscope 107:491–499PubMed
92.
go back to reference Hauser R, Westermann B, Probst R (1997) A noninvasive patient registration and reference system for interactive intraoperative sinus surgery. Proc Inst Mech Eng 211:327–334 Hauser R, Westermann B, Probst R (1997) A noninvasive patient registration and reference system for interactive intraoperative sinus surgery. Proc Inst Mech Eng 211:327–334
93.
go back to reference Heilbrun MP (1984) Computed tomography-guided stereotactic system. Clin Neurosurg 31:564–581 Heilbrun MP (1984) Computed tomography-guided stereotactic system. Clin Neurosurg 31:564–581
94.
go back to reference Heilbrun MP, McDonald P, Wiker C (1992) Stereotactic localization and guidance using a machine vision technique. Stereotact Funct Neurosurg 58:94–98PubMed Heilbrun MP, McDonald P, Wiker C (1992) Stereotactic localization and guidance using a machine vision technique. Stereotact Funct Neurosurg 58:94–98PubMed
95.
go back to reference Helm PA, Eckel T (1998) Accuracy of registration methods in frameless stereotaxis. Comput Aided Surg 3:51–56CrossRefPubMed Helm PA, Eckel T (1998) Accuracy of registration methods in frameless stereotaxis. Comput Aided Surg 3:51–56CrossRefPubMed
96.
go back to reference Henderson JM, Smith KR, Bucholz RD (1994) An accurate and ergonomic method for registration for image-guided surgery. Comput Med Imaging Graph 18:273–277PubMed Henderson JM, Smith KR, Bucholz RD (1994) An accurate and ergonomic method for registration for image-guided surgery. Comput Med Imaging Graph 18:273–277PubMed
97.
go back to reference Homer (1974) Iliad. Murray AT (ed) Harvard University Press, London Homer (1974) Iliad. Murray AT (ed) Harvard University Press, London
98.
go back to reference Homer (1974) Odyssey. Murray AT (ed) Harvard University Press, London Homer (1974) Odyssey. Murray AT (ed) Harvard University Press, London
99.
go back to reference Hopf NJ, Grunert P, Darabi K, Busert C, Bettag M (1999) Frameless neuronavigation applied to endoscopic neurosurgery. Minim Invasive Neurosurg 42:187–193PubMed Hopf NJ, Grunert P, Darabi K, Busert C, Bettag M (1999) Frameless neuronavigation applied to endoscopic neurosurgery. Minim Invasive Neurosurg 42:187–193PubMed
100.
go back to reference Horsley V, Clarke RH (1908) The structure and functions of the cerebellum examined by a new method. Brain 31:45–124 Horsley V, Clarke RH (1908) The structure and functions of the cerebellum examined by a new method. Brain 31:45–124
101.
go back to reference Horstmann GA, Reinhardt HF (1994) Ranging accuracy test of the sonic microstereotactic system. Neurosurgery 34:754–755PubMed Horstmann GA, Reinhardt HF (1994) Ranging accuracy test of the sonic microstereotactic system. Neurosurgery 34:754–755PubMed
102.
go back to reference Hounsfield GN (1973) Computerized transaxial scanning (tomography). Part I: Description of a system. Br J Radiol 46:1016–1022PubMed Hounsfield GN (1973) Computerized transaxial scanning (tomography). Part I: Description of a system. Br J Radiol 46:1016–1022PubMed
103.
go back to reference Hunnerup PB, Nielsen JB (1994) Real time navigation. System for neurosurgery. Master's thesis. Aalborg University, Denmark Hunnerup PB, Nielsen JB (1994) Real time navigation. System for neurosurgery. Master's thesis. Aalborg University, Denmark
104.
go back to reference Kai J, Shiomi H, Sasama T, Sato Y, Inoue T, Tamura S (1998) An optical high-precision 3-D position measurement system suitable for head motion tracking in frameless stereotactic radiosurgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 599–604 Kai J, Shiomi H, Sasama T, Sato Y, Inoue T, Tamura S (1998) An optical high-precision 3-D position measurement system suitable for head motion tracking in frameless stereotactic radiosurgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 599–604
105.
go back to reference Kato A, Yoshimine T, Hayakawa T, Tomita Y, Ikeda T, Mitomo M, Harada K, Mogami H (1991) A frameless, armless navigation system for computer-assisted neurosurgery. J Neurosurg 74:845–849PubMed Kato A, Yoshimine T, Hayakawa T, Tomita Y, Ikeda T, Mitomo M, Harada K, Mogami H (1991) A frameless, armless navigation system for computer-assisted neurosurgery. J Neurosurg 74:845–849PubMed
106.
go back to reference Kelly PJ (1999) Electromagnetic operative guidance: the regulus navigator. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 365–372 Kelly PJ (1999) Electromagnetic operative guidance: the regulus navigator. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 365–372
107.
go back to reference Kelly PJ, Kall B, Goerss S (1984) Transposition of volumetric information derived from CT scanning in stereotactic space. Surg Neurol 21:465–471PubMed Kelly PJ, Kall B, Goerss S (1984) Transposition of volumetric information derived from CT scanning in stereotactic space. Surg Neurol 21:465–471PubMed
108.
go back to reference Kirschner M (1933) Die Punktionstechnik und die Elektrokoagulation des Ganglion Gasseri. Über gezielte Operationen. Arch Klin Chir 176:581–620 Kirschner M (1933) Die Punktionstechnik und die Elektrokoagulation des Ganglion Gasseri. Über gezielte Operationen. Arch Klin Chir 176:581–620
109.
go back to reference Kiya N, Dureca C, Fukushima T, Maroon JC (1997) Computer navigational microscope for minimally invasive neurosurgery. Minim Invasive Neurosurg 40:110–115PubMed Kiya N, Dureca C, Fukushima T, Maroon JC (1997) Computer navigational microscope for minimally invasive neurosurgery. Minim Invasive Neurosurg 40:110–115PubMed
110.
go back to reference Knauth M, Wirtz CR, Tronnier VM, Staubert A, Kunze S, Sartor K (1998) Intraoperative magnetic resonance tomography for control of extent of neurosurgical operations. Radiologe 38:218–224CrossRefPubMed Knauth M, Wirtz CR, Tronnier VM, Staubert A, Kunze S, Sartor K (1998) Intraoperative magnetic resonance tomography for control of extent of neurosurgical operations. Radiologe 38:218–224CrossRefPubMed
111.
go back to reference Ko K (1998) Superimposed holographic image-guided neurosurgery. Technical note. J Neurosurg 88:777–781PubMed Ko K (1998) Superimposed holographic image-guided neurosurgery. Technical note. J Neurosurg 88:777–781PubMed
112.
go back to reference Konen W, Scholz M, Tombrock S (1998) The VN project: endoscopic image processing for neurosurgery. Comput Aided Surg 3:144–148CrossRefPubMed Konen W, Scholz M, Tombrock S (1998) The VN project: endoscopic image processing for neurosurgery. Comput Aided Surg 3:144–148CrossRefPubMed
113.
go back to reference Kosugi Y, Watanabe E, Goto J (1988) An articulated neurosurgical navigation system using MRI and CT images. IEEE Trans Biomed Eng 35:147–152PubMed Kosugi Y, Watanabe E, Goto J (1988) An articulated neurosurgical navigation system using MRI and CT images. IEEE Trans Biomed Eng 35:147–152PubMed
114.
go back to reference Koivukangas J, Louhisalmi Y, Alakuijala J, et al (1993) Ultrasound-controlled neuronavigator-guided brain surgery. J Neurosurg 79:36–42PubMed Koivukangas J, Louhisalmi Y, Alakuijala J, et al (1993) Ultrasound-controlled neuronavigator-guided brain surgery. J Neurosurg 79:36–42PubMed
115.
go back to reference Krings T, Reul J, Spetzger U, Klusmann A, Roessler F, Gilsbach JM, Thron A (1998) Functional magnetic resonance mapping of sensory motor cortex for image-guided neurosurgical intervention. Acta Neurochir (Wien) 140:215–222 Krings T, Reul J, Spetzger U, Klusmann A, Roessler F, Gilsbach JM, Thron A (1998) Functional magnetic resonance mapping of sensory motor cortex for image-guided neurosurgical intervention. Acta Neurochir (Wien) 140:215–222
116.
go back to reference Krombach GA, Spetzger U, Rohde V, Gilsbach JM (1998) Intraoperative localization of functional regions in the sensomotor cortex by neuronavigation and cortical mapping. Comput Aided Surg 3:64–73PubMed Krombach GA, Spetzger U, Rohde V, Gilsbach JM (1998) Intraoperative localization of functional regions in the sensomotor cortex by neuronavigation and cortical mapping. Comput Aided Surg 3:64–73PubMed
117.
go back to reference Kwoh YS, Hou J, Jonckheere EA, Hayati S (1988) A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery. IEEE Trans Biomed Eng 35:153–160CrossRefPubMed Kwoh YS, Hou J, Jonckheere EA, Hayati S (1988) A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery. IEEE Trans Biomed Eng 35:153–160CrossRefPubMed
118.
go back to reference Laborde G, Klimek L, Harders A, Gilsbach J (1993) Frameless stereotactic drainage of intracranial abscesses. Surg Neurol 40:16–21PubMed Laborde G, Klimek L, Harders A, Gilsbach J (1993) Frameless stereotactic drainage of intracranial abscesses. Surg Neurol 40:16–21PubMed
119.
go back to reference Lavallee S (1996) Registration for computer-integrated surgery: methodology, state of the art. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer-integrated surgery. MIT Press, Cambridge, pp 77–97 Lavallee S (1996) Registration for computer-integrated surgery: methodology, state of the art. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer-integrated surgery. MIT Press, Cambridge, pp 77–97
120.
go back to reference Lavallee S, Szelisky R, Brunie L (1996) Anatomy-based registration of three-dimensional medical images, range images, X-ray projections, and three-dimensional models using octree-splines. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer-integrated surgery. MIT Press, Cambridge, pp 115–143 Lavallee S, Szelisky R, Brunie L (1996) Anatomy-based registration of three-dimensional medical images, range images, X-ray projections, and three-dimensional models using octree-splines. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer-integrated surgery. MIT Press, Cambridge, pp 115–143
121.
go back to reference Lawton MT, Spetzler RF (1999) Clinical experience with a frameless stereotactic arm in intracranial neurosurgery. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 321–332 Lawton MT, Spetzler RF (1999) Clinical experience with a frameless stereotactic arm in intracranial neurosurgery. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 321–332
122.
go back to reference Leksell L (1949) A stereotactic apparatus for intracranial surgery. Acta Chir Scand 99:229–233 Leksell L (1949) A stereotactic apparatus for intracranial surgery. Acta Chir Scand 99:229–233
123.
go back to reference Leksell L (1951) The stereotactic method and radiosurgery of the brain. Acta Chir Scand 102:316–319 Leksell L (1951) The stereotactic method and radiosurgery of the brain. Acta Chir Scand 102:316–319
124.
go back to reference Lewis JT, Galloway RL Jr, Schreiner S (1998) An ultrasound approach to localization of fiducial markers for interactive, image-guided neurosurgery. Part I: Principles. IEEE Trans Biomed Eng 45:620–630CrossRefPubMed Lewis JT, Galloway RL Jr, Schreiner S (1998) An ultrasound approach to localization of fiducial markers for interactive, image-guided neurosurgery. Part I: Principles. IEEE Trans Biomed Eng 45:620–630CrossRefPubMed
125.
go back to reference Longerich UJ, Carls FR, Broennimann R, Sailer HF (1997) The accuracy of the virtual patient system for cranio-maxillofacial navigation. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 729–732 Longerich UJ, Carls FR, Broennimann R, Sailer HF (1997) The accuracy of the virtual patient system for cranio-maxillofacial navigation. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 729–732
126.
go back to reference Luber J, Mackevics A (1995) Multiple coordinate manipulator (MKM). A computer assisted microscope. In: Lemke HU, Vannier MW (eds) CAR 95. Elsevier, Amsterdam pp 1121–1125 Luber J, Mackevics A (1995) Multiple coordinate manipulator (MKM). A computer assisted microscope. In: Lemke HU, Vannier MW (eds) CAR 95. Elsevier, Amsterdam pp 1121–1125
127.
go back to reference Maciunas RJ, Galloway RL, Fitzpatrick JR, Mandava VR, Edwards CA, Allen GS (1992) A universal system for interactive image-directed neurosurgery. Stereotact Funct Neurosurg 58:108–113PubMed Maciunas RJ, Galloway RL, Fitzpatrick JR, Mandava VR, Edwards CA, Allen GS (1992) A universal system for interactive image-directed neurosurgery. Stereotact Funct Neurosurg 58:108–113PubMed
128.
go back to reference Maciunas RJ (1999) Overview of interactive image-guided neurosurgery: principles, applications, and new techniques. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 15–32 Maciunas RJ (1999) Overview of interactive image-guided neurosurgery: principles, applications, and new techniques. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 15–32
129.
go back to reference Maciunas RJ, Fitzpatrick JM, Gadamsetty S, Mauer CR Jr (1996) A universal method for geometric correction of magnetic resonance images for stereotactic neurosurgery. Stereotact Funct Neurosurg 66:137–140PubMed Maciunas RJ, Fitzpatrick JM, Gadamsetty S, Mauer CR Jr (1996) A universal method for geometric correction of magnetic resonance images for stereotactic neurosurgery. Stereotact Funct Neurosurg 66:137–140PubMed
130.
go back to reference Maciunas RJ, Berger MS, Copeland B, Mayberg MR, Selker R, Allen GS (1996) A technique for interactive image-guided neurosurgical intervention in primary brain tumors. Neurosurg Clin N Ann 7:245–266 Maciunas RJ, Berger MS, Copeland B, Mayberg MR, Selker R, Allen GS (1996) A technique for interactive image-guided neurosurgical intervention in primary brain tumors. Neurosurg Clin N Ann 7:245–266
131.
go back to reference Maciunas RJ, Galloway RL, Latimer JW (1994) The application accuracy of stereotactic frames. Neurosurgery 35:682–695PubMed Maciunas RJ, Galloway RL, Latimer JW (1994) The application accuracy of stereotactic frames. Neurosurgery 35:682–695PubMed
132.
go back to reference Maldijian J, Atlas SW, Howard RS II, Greenstein E, Alsop D, Detre JA, Liesterud J, D'Exposito M, Flamm ES (1996) Functional magnetic resonance imaging of regional brain activity in patients with intracerebral arteriovenous malformations before surgical or endovascular therapy. J Neurosurg 84:477–483PubMed Maldijian J, Atlas SW, Howard RS II, Greenstein E, Alsop D, Detre JA, Liesterud J, D'Exposito M, Flamm ES (1996) Functional magnetic resonance imaging of regional brain activity in patients with intracerebral arteriovenous malformations before surgical or endovascular therapy. J Neurosurg 84:477–483PubMed
133.
go back to reference Manwaring KH (1999) Neuronavigation using magnetic fields. Workshop on endoscopy and navigation. Greifswald (personal communication) Manwaring KH (1999) Neuronavigation using magnetic fields. Workshop on endoscopy and navigation. Greifswald (personal communication)
134.
go back to reference Masamune K, Ji L, Suzuki M, Dohi T, Iseki H, Takakura K (1998) A new development of stereotactic robot with detachable drive for neurosurgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 664–669 Masamune K, Ji L, Suzuki M, Dohi T, Iseki H, Takakura K (1998) A new development of stereotactic robot with detachable drive for neurosurgery. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 664–669
135.
go back to reference Matula C, Roessler K, Reddy M, Schindler E, Koos WT (1998) Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow. Comput Aided Surg 3:174–182PubMed Matula C, Roessler K, Reddy M, Schindler E, Koos WT (1998) Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow. Comput Aided Surg 3:174–182PubMed
136.
go back to reference Maurer CR, Maciunas RJ, Fitzpatrick JM (1998) Registration of head CT images to physical space using a weighted combination of points and surfaces. IEEE Trans Med Imaging 17:753–761PubMed Maurer CR, Maciunas RJ, Fitzpatrick JM (1998) Registration of head CT images to physical space using a weighted combination of points and surfaces. IEEE Trans Med Imaging 17:753–761PubMed
137.
go back to reference Maurer CR, Aboutanos GB, Dawant BM, Gadamsetty S, Margolin RA, Maciunas RJ (1996) Effect of geometrical distortion correction in MR on image registration accuracy. J Comput Assist Tomogr 20:666–679CrossRefPubMed Maurer CR, Aboutanos GB, Dawant BM, Gadamsetty S, Margolin RA, Maciunas RJ (1996) Effect of geometrical distortion correction in MR on image registration accuracy. J Comput Assist Tomogr 20:666–679CrossRefPubMed
138.
go back to reference Maurer CR, Fitzpatrick JM, Wang MY, Galloway RL Jr, Maciunas RJ, Allen GS (1997) Registration of head volume images using implantable fiducial markers. IEEE Trans Med Imaging 16:447–462CrossRefPubMed Maurer CR, Fitzpatrick JM, Wang MY, Galloway RL Jr, Maciunas RJ, Allen GS (1997) Registration of head volume images using implantable fiducial markers. IEEE Trans Med Imaging 16:447–462CrossRefPubMed
139.
go back to reference Mauerer CR, Hill DL, Martin AJ, Liu H, McCue M, Rueckert D, Lloret D, Hall WA, Maxwell RC, Hawkes DJ, Truwit CL (1998) Investigation of intraoperative brain deformation using a 1.5 T interventional MR system. preliminary results. IEEE Trans Med Imaging 17:817–825CrossRefPubMed Mauerer CR, Hill DL, Martin AJ, Liu H, McCue M, Rueckert D, Lloret D, Hall WA, Maxwell RC, Hawkes DJ, Truwit CL (1998) Investigation of intraoperative brain deformation using a 1.5 T interventional MR system. preliminary results. IEEE Trans Med Imaging 17:817–825CrossRefPubMed
140.
go back to reference McDermott MW (1998) Intracranial gliomas. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 77–86 McDermott MW (1998) Intracranial gliomas. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 77–86
141.
go back to reference Merloz P, Tonetti J, Cinquin P, Lavalles S, Troccaz J, Pitet L (1998) Chirurgie assistée par ordinateur: visage automatisé de pèdicules vertebreaux. Chirurgie 123:482–490PubMed Merloz P, Tonetti J, Cinquin P, Lavalles S, Troccaz J, Pitet L (1998) Chirurgie assistée par ordinateur: visage automatisé de pèdicules vertebreaux. Chirurgie 123:482–490PubMed
142.
go back to reference Miga MI, Paulsen KD, Lemery JM, Eisner SD, Hartov A, Kennedy FE, Roberts DW (1999) Model-updated image guidance: initial clinical experiences with gravity-induced brain deformation. IEEE Trans Med Imaging 18:866–874CrossRefPubMed Miga MI, Paulsen KD, Lemery JM, Eisner SD, Hartov A, Kennedy FE, Roberts DW (1999) Model-updated image guidance: initial clinical experiences with gravity-induced brain deformation. IEEE Trans Med Imaging 18:866–874CrossRefPubMed
143.
go back to reference Moniz E (1927) L'encephalographie arterielle, s'importance dans la localisation des tumeurs cerebrales. Rev Neurol 2:72–89 Moniz E (1927) L'encephalographie arterielle, s'importance dans la localisation des tumeurs cerebrales. Rev Neurol 2:72–89
144.
go back to reference Mösges R, Schlöndorff G (1988) A new imaging method for intraoperative therapy control in skull base surgery. Neurosurg Rev 11:245–247PubMed Mösges R, Schlöndorff G (1988) A new imaging method for intraoperative therapy control in skull base surgery. Neurosurg Rev 11:245–247PubMed
145.
go back to reference Mösges R, Lavallee S (1996) Multimodal information for computer-integrated surgery. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer integrated surgery. MIT Press, Cambridge, pp 5–19 Mösges R, Lavallee S (1996) Multimodal information for computer-integrated surgery. In: Taylor RH, Lavallee S, Burdea GC, Mösges R (eds) Computer integrated surgery. MIT Press, Cambridge, pp 5–19
146.
go back to reference Muacevic A, Steiger HJ (1999) Computer-assisted resection of cerebral arteriovenous malformations. Neurosurgery 45:1164–1170PubMed Muacevic A, Steiger HJ (1999) Computer-assisted resection of cerebral arteriovenous malformations. Neurosurgery 45:1164–1170PubMed
147.
go back to reference Muacevic A, Muller A (1999) Image-guided endoscopic ventriculostomy with a new frameless armless neuronavigation system. Comput Aided Surg 4:87–92PubMed Muacevic A, Muller A (1999) Image-guided endoscopic ventriculostomy with a new frameless armless neuronavigation system. Comput Aided Surg 4:87–92PubMed
148.
go back to reference Nabavi A, Manthei G, Blömer U, Kumpf L, Klinge H, Mehdorn HM (1995) Neuronavigation. Computerunterstütztes Operieren in der Neurochirurgie. Radiologe 35:573–577PubMed Nabavi A, Manthei G, Blömer U, Kumpf L, Klinge H, Mehdorn HM (1995) Neuronavigation. Computerunterstütztes Operieren in der Neurochirurgie. Radiologe 35:573–577PubMed
149.
go back to reference Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer aided fixation of spinal implants. J Image Guided Surg 1:88–93CrossRef Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer aided fixation of spinal implants. J Image Guided Surg 1:88–93CrossRef
150.
go back to reference Nguyen JP, Lefaucher JP, Decq P, Uchiyama T, Carpentier A, Fontaine D, Brugieres P, Pollin B, Feve A, Rostaing S, Cesaro P, Keravel Y (1999) Chronic motor cortex stimulation in the treatment of central and neuropathic pain. Correlation between clinical, electrophysiological and anatomical data. Pain 82:245–251CrossRefPubMed Nguyen JP, Lefaucher JP, Decq P, Uchiyama T, Carpentier A, Fontaine D, Brugieres P, Pollin B, Feve A, Rostaing S, Cesaro P, Keravel Y (1999) Chronic motor cortex stimulation in the treatment of central and neuropathic pain. Correlation between clinical, electrophysiological and anatomical data. Pain 82:245–251CrossRefPubMed
151.
go back to reference Paleologos TS, Wadley JP, Kitchen ND, Thomas DG (2000) Clinical utility and cost-effectiveness of interactive image-guided craniotomy: clinical comparison between conventional and image-guided meningeoma surgery. Neurosurgery 47:40–47PubMed Paleologos TS, Wadley JP, Kitchen ND, Thomas DG (2000) Clinical utility and cost-effectiveness of interactive image-guided craniotomy: clinical comparison between conventional and image-guided meningeoma surgery. Neurosurgery 47:40–47PubMed
152.
go back to reference Pelizzari CA, Chen GTY (1987) Registration of multiple diagnostic image scans using surface fitting. In: The use of computers in radiation therapy. Elsevier, Amsterdam, pp 437–440 Pelizzari CA, Chen GTY (1987) Registration of multiple diagnostic image scans using surface fitting. In: The use of computers in radiation therapy. Elsevier, Amsterdam, pp 437–440
153.
go back to reference Penfield W, Roberts L (1959) Speech and brain mechanisms. Princeton University Press, Princeton Penfield W, Roberts L (1959) Speech and brain mechanisms. Princeton University Press, Princeton
154.
go back to reference Penfield W, Boldrey E (1937) Somatic motor and sensory representation in the cerebral cortex of man as studied by electrical stimulation. Brain 60:389–443 Penfield W, Boldrey E (1937) Somatic motor and sensory representation in the cerebral cortex of man as studied by electrical stimulation. Brain 60:389–443
155.
go back to reference Perneczky A, Fries G (1998) Endoscope-assisted brain surgery. Part I. Evolution, basic concept, and current technique. Neurosurgery 42:219–225PubMed Perneczky A, Fries G (1998) Endoscope-assisted brain surgery. Part I. Evolution, basic concept, and current technique. Neurosurgery 42:219–225PubMed
156.
go back to reference Perneczky A, Tschabitscher M, Resch KDM (1993) Endoscopic anatomy for neurosurgery. Thieme, Stuttgart Perneczky A, Tschabitscher M, Resch KDM (1993) Endoscopic anatomy for neurosurgery. Thieme, Stuttgart
157.
go back to reference Perneczky A, Müller-Forell W, van Lindert E (1998) Key hole concept in neurosurgery with endoscope-assisted microsurgery. Twenty-five case studies. Thieme, Stuttgart Perneczky A, Müller-Forell W, van Lindert E (1998) Key hole concept in neurosurgery with endoscope-assisted microsurgery. Twenty-five case studies. Thieme, Stuttgart
158.
go back to reference Pieper DL (1968) The kinematics of manipulators under computer control. Standford artificial intelligence laboratory, Standford University AIM 72 Pieper DL (1968) The kinematics of manipulators under computer control. Standford artificial intelligence laboratory, Standford University AIM 72
159.
go back to reference Ogawa S, Tank DW, Menon R (1992) Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. Proc Natl Acad Sci U S A 89:5951–5955PubMed Ogawa S, Tank DW, Menon R (1992) Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. Proc Natl Acad Sci U S A 89:5951–5955PubMed
160.
go back to reference Ojeman G, Ojeman J, Lettich E, Berger M (1989) Cortical language localization in left, dominant hemisphere. J Neurosurg 71:316–326PubMed Ojeman G, Ojeman J, Lettich E, Berger M (1989) Cortical language localization in left, dominant hemisphere. J Neurosurg 71:316–326PubMed
161.
go back to reference Olivier A, Germano IM, Cukiert A, Peters T (1994) frameless stereotaxy for surgery of the epilepsies: preliminary experience. J Neurosurg 81:629–633PubMed Olivier A, Germano IM, Cukiert A, Peters T (1994) frameless stereotaxy for surgery of the epilepsies: preliminary experience. J Neurosurg 81:629–633PubMed
162.
go back to reference Olivier A, Cyr M, Comeau R, Peters T, Boling W, Klein D, Reutens D (1999) Image guided surgery of epilepsy and intrinsic brain tumors. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 469–482 Olivier A, Cyr M, Comeau R, Peters T, Boling W, Klein D, Reutens D (1999) Image guided surgery of epilepsy and intrinsic brain tumors. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 469–482
163.
go back to reference Ostertag CB, Warnke PC (1999) Neuronavigation. Computerassistierte Neurochirurgie. Nervenarzt 70:517–521CrossRefPubMed Ostertag CB, Warnke PC (1999) Neuronavigation. Computerassistierte Neurochirurgie. Nervenarzt 70:517–521CrossRefPubMed
164.
go back to reference Radon J (1917) Über die Bestimmung von Functionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten. Berichte Sächsischer Akademie der Wissenschaften. Leipzig Math-Phys Kl 69:262–277 Radon J (1917) Über die Bestimmung von Functionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten. Berichte Sächsischer Akademie der Wissenschaften. Leipzig Math-Phys Kl 69:262–277
165.
go back to reference Reinges MH, Spetzger U, Rohde V, Adams L, Gilsbach JM (1998) Experience with a new multifunctional articulated instrument holder in minimally invasive navigated surgery. Minim Invas Neurosurg 41:149–151 Reinges MH, Spetzger U, Rohde V, Adams L, Gilsbach JM (1998) Experience with a new multifunctional articulated instrument holder in minimally invasive navigated surgery. Minim Invas Neurosurg 41:149–151
166.
go back to reference Reinhardt HF, Meyer H, Amrein E (1988) A computer-assisted device for intraoperative CT-correlated localization of brain tumors. Eur Surg Res 20:51–58PubMed Reinhardt HF, Meyer H, Amrein E (1988) A computer-assisted device for intraoperative CT-correlated localization of brain tumors. Eur Surg Res 20:51–58PubMed
167.
go back to reference Reinhardt HF, Horstmann GA, Gratzl O (1993) Sonic stereometry in microsurgical procedures for deep-seated brain tumors and vascular malformations. Neurosurgery 32:51–57PubMed Reinhardt HF, Horstmann GA, Gratzl O (1993) Sonic stereometry in microsurgical procedures for deep-seated brain tumors and vascular malformations. Neurosurgery 32:51–57PubMed
168.
go back to reference Reinhardt HF, Trippl M, Westermann B, Horstmann GA, Gratzl O (1996) Computer assisted brain surgery for small lesions in the central sensorimotor region. Acta Neurochir (Wien) 138:200–205 Reinhardt HF, Trippl M, Westermann B, Horstmann GA, Gratzl O (1996) Computer assisted brain surgery for small lesions in the central sensorimotor region. Acta Neurochir (Wien) 138:200–205
169.
go back to reference Rhoten RL, Luciano MG, Barnett GH (1997) Computer-assisted endoscopy for neurosurgical procedures: technical note. Neurosurgery 40:632–637PubMed Rhoten RL, Luciano MG, Barnett GH (1997) Computer-assisted endoscopy for neurosurgical procedures: technical note. Neurosurgery 40:632–637PubMed
170.
go back to reference Riechert T, Wolff M (1952) Ein neues Zielgerät für die Koagulation des Ganglion Gasseri und andere intracerebrale Eingriffe. Acta Neurochir 2:405–407 Riechert T, Wolff M (1952) Ein neues Zielgerät für die Koagulation des Ganglion Gasseri und andere intracerebrale Eingriffe. Acta Neurochir 2:405–407
171.
go back to reference Roberts LG (1963) Machine perception of three-dimensional Solids. Lincoln Laboratory, Massachusetts Institute of Technology report no. 315 Roberts LG (1963) Machine perception of three-dimensional Solids. Lincoln Laboratory, Massachusetts Institute of Technology report no. 315
172.
go back to reference Roberts LG (1965) Homogenous matrix representation and manipulation of N-dimensional constructs. Lincoln Laboratory, Massachusetts Institute of Technology document no. MS1045 Roberts LG (1965) Homogenous matrix representation and manipulation of N-dimensional constructs. Lincoln Laboratory, Massachusetts Institute of Technology document no. MS1045
173.
go back to reference Roberts DW (1999) Stereotactic guidance with the operating microscope: surgiscope. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 333–343 Roberts DW (1999) Stereotactic guidance with the operating microscope: surgiscope. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 333–343
174.
go back to reference Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD (1999) Intraoperatively updated neuroimaging using brain modeling and sparse data. Neurosurgery 45:1199–1206PubMed Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD (1999) Intraoperatively updated neuroimaging using brain modeling and sparse data. Neurosurgery 45:1199–1206PubMed
175.
go back to reference Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, Czech T, Koos WT (1997) Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system. Acta Neurochir (Wien) 139:551–559 Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, Czech T, Koos WT (1997) Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system. Acta Neurochir (Wien) 139:551–559
176.
go back to reference Roessler K, Ungersboeck K, Czech T, Aichholzer M, Dietrich W, Goerzer H, Matula C, Koos WT (1997) Contour-guided brain tumor surgery using a stereotactic navigation microscope. Stereotact Funct Neurosurg 68:33–38PubMed Roessler K, Ungersboeck K, Czech T, Aichholzer M, Dietrich W, Goerzer H, Matula C, Koos WT (1997) Contour-guided brain tumor surgery using a stereotactic navigation microscope. Stereotact Funct Neurosurg 68:33–38PubMed
177.
go back to reference Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Czech T, Heimberger K, Matula C, Koos WT (1998) Image-guided neurosurgery comparing a pointer device system with a navigating microscope: a retrospective analysis of 208 cases. Minim Invasive Neurosurg 41:53–57PubMed Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Czech T, Heimberger K, Matula C, Koos WT (1998) Image-guided neurosurgery comparing a pointer device system with a navigating microscope: a retrospective analysis of 208 cases. Minim Invasive Neurosurg 41:53–57PubMed
178.
go back to reference Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C, Czech T, Koos WT (1998) Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope. Surg Neurol 49:282–288PubMed Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C, Czech T, Koos WT (1998) Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope. Surg Neurol 49:282–288PubMed
179.
go back to reference Roessler K, Czech T, Dietrich W, Ungersboeck K, Nasel C, Hainfellner JA, Koos WT (1998) Frameless stereotactic-directed tissue sampling during surgery of suspected low-grade gliomas to avoid histological undergrading. Minim Invasive Neurosurg 41:183–186PubMed Roessler K, Czech T, Dietrich W, Ungersboeck K, Nasel C, Hainfellner JA, Koos WT (1998) Frameless stereotactic-directed tissue sampling during surgery of suspected low-grade gliomas to avoid histological undergrading. Minim Invasive Neurosurg 41:183–186PubMed
180.
go back to reference Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43:749–760PubMed Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43:749–760PubMed
181.
go back to reference Roberts DW, Nakayama T, Brodwater BK; Pavlidis J, Friets EM, Fagan E, Hartov A, Strohbehn JW (1992) Further development and clinical application of the stereotactic operating microscope. Stereotact Funct Neurosurg 58:114–117PubMed Roberts DW, Nakayama T, Brodwater BK; Pavlidis J, Friets EM, Fagan E, Hartov A, Strohbehn JW (1992) Further development and clinical application of the stereotactic operating microscope. Stereotact Funct Neurosurg 58:114–117PubMed
182.
go back to reference Roberts DW (1998) Fundamentals of registration. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 1–15 Roberts DW (1998) Fundamentals of registration. In: Roberts DW, Barnett GH, Maciunas RJ (eds) Image-guided neurosurgery. Quality Medical, St. Louis, pp 1–15
183.
go back to reference Rohde V, Reinges MH, Krombach GA, Gilsbach JM (1998) The combined use of image-guided frameless stereotaxy and neuroendoscopy for the surgical management of occlusive hydrocephalus and intracranial cysts. Br J Neurosurg 12:531–538PubMed Rohde V, Reinges MH, Krombach GA, Gilsbach JM (1998) The combined use of image-guided frameless stereotaxy and neuroendoscopy for the surgical management of occlusive hydrocephalus and intracranial cysts. Br J Neurosurg 12:531–538PubMed
184.
go back to reference Rohde V, Rohde I, Reinges MH, Mayfrank L, Gilsbach JM (2000) Frameless stereotactically guided catheter placement and fibrinolytic therapy for spontaneous intracerebral hematomas: technical aspects and initial clinical results. Minim Invasive Neurosurg 43:9–17CrossRefPubMed Rohde V, Rohde I, Reinges MH, Mayfrank L, Gilsbach JM (2000) Frameless stereotactically guided catheter placement and fibrinolytic therapy for spontaneous intracerebral hematomas: technical aspects and initial clinical results. Minim Invasive Neurosurg 43:9–17CrossRefPubMed
185.
go back to reference Rosenberg J (1972) A history of numerical control 1949–1972. The technical development, transfer to industry, and assimilation. Report no. ISI-RR-72–3. USC Information Sciences Institute, Marina del Rey Rosenberg J (1972) A history of numerical control 1949–1972. The technical development, transfer to industry, and assimilation. Report no. ISI-RR-72–3. USC Information Sciences Institute, Marina del Rey
186.
go back to reference Rousseau J, Gibon D, Coste E, Blond S, Pertuzon B, Coche B, Vasseur C, Marchandise X (1995) A frameless stereotactic localization system using MRI, CT, and DSA. Acta Neurochir Suppl (Wien) 64:40–44 Rousseau J, Gibon D, Coste E, Blond S, Pertuzon B, Coche B, Vasseur C, Marchandise X (1995) A frameless stereotactic localization system using MRI, CT, and DSA. Acta Neurochir Suppl (Wien) 64:40–44
187.
go back to reference Roux FE, Ranjeva JP, Boulanouar K, Manelfe C, Sabatier J, Tremoulet M, Berry I (1997) Motor functional MRI for presurgical evaluation of cerebral tumors. Stereotactic Funct Neurosurg 68:106–111 Roux FE, Ranjeva JP, Boulanouar K, Manelfe C, Sabatier J, Tremoulet M, Berry I (1997) Motor functional MRI for presurgical evaluation of cerebral tumors. Stereotactic Funct Neurosurg 68:106–111
188.
go back to reference Ryan MJ, Erickson RK, Levin DN, Pelizzari CA, Macdonald RL, Dohrmann GJ (1996) Frameless stereotaxy with real time tracking of patient's head movement and retrospective patient-image registration. J Neurosurg 85:287–292PubMed Ryan MJ, Erickson RK, Levin DN, Pelizzari CA, Macdonald RL, Dohrmann GJ (1996) Frameless stereotaxy with real time tracking of patient's head movement and retrospective patient-image registration. J Neurosurg 85:287–292PubMed
189.
go back to reference Samii M, Carvalho GA, Tatagiba M, Matthies C, Vorkapic P (1996) Meningeomas of the tentorial notch: surgical anatomy and management. J Neurosurg 84:375–381PubMed Samii M, Carvalho GA, Tatagiba M, Matthies C, Vorkapic P (1996) Meningeomas of the tentorial notch: surgical anatomy and management. J Neurosurg 84:375–381PubMed
190.
go back to reference Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/Elekta viewing wand. Acta Neurochir Suppl 64:54–58 Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/Elekta viewing wand. Acta Neurochir Suppl 64:54–58
191.
go back to reference Sandeman D, Moufild A (1998) Interactive image-guided pituitary surgery. An experience of 101 procedures. Neurochirurgie 44:331–338PubMed Sandeman D, Moufild A (1998) Interactive image-guided pituitary surgery. An experience of 101 procedures. Neurochirurgie 44:331–338PubMed
192.
go back to reference Scarabin JM, Jannin P, Schartz D, Morandi X. MEG and 3-D navigation in image guided neurosurgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam pp 767–771 Scarabin JM, Jannin P, Schartz D, Morandi X. MEG and 3-D navigation in image guided neurosurgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam pp 767–771
193.
go back to reference Scheinmann VD (1969) Design of a computer manipulator. Standford artificial intelligence laboratory. Standford University, AIM 92 Scheinmann VD (1969) Design of a computer manipulator. Standford artificial intelligence laboratory. Standford University, AIM 92
194.
go back to reference Schmerber S, Chen B, Lavallee S, Chirosel JP, Poyet A, Colomb M, Reyt E (1997) Markerless hybrid registration method for computer assisted endoscopic ENT surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam pp 799–806 Schmerber S, Chen B, Lavallee S, Chirosel JP, Poyet A, Colomb M, Reyt E (1997) Markerless hybrid registration method for computer assisted endoscopic ENT surgery. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam pp 799–806
195.
go back to reference Schmieder K, Hardenack M, Harders A (1998) Neuronavigation in daily routine of a neurosurgical department. Comput Aided Surg 3:159–161CrossRefPubMed Schmieder K, Hardenack M, Harders A (1998) Neuronavigation in daily routine of a neurosurgical department. Comput Aided Surg 3:159–161CrossRefPubMed
196.
go back to reference Schleidt DT, Dobrzeniecky AB, Dirksen KL, Larsen P, Kreiborg S (1998) Volume imaging for maxillofacial applications: estimation and analysis of CT measurement errors. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 773–779 Schleidt DT, Dobrzeniecky AB, Dirksen KL, Larsen P, Kreiborg S (1998) Volume imaging for maxillofacial applications: estimation and analysis of CT measurement errors. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 773–779
197.
go back to reference Schlöndorff G, Meyer-Ebrecht D, Mösges R, Krybus W, Adams L (1987) CAS, computer assisted surgery. Arch Otorhinolaryng [Suppl] 2:45 Schlöndorff G, Meyer-Ebrecht D, Mösges R, Krybus W, Adams L (1987) CAS, computer assisted surgery. Arch Otorhinolaryng [Suppl] 2:45
198.
go back to reference Schreiner S, Galloway RL Jr, Lewis JT, Bass WA, Muratore DM (1998) An ultrasound approach to localization of fiducial markers for interactive image-guided neurosurgery. Part II: Implementation and automation. IEEE Trans Biomed Eng 45:631–641CrossRefPubMed Schreiner S, Galloway RL Jr, Lewis JT, Bass WA, Muratore DM (1998) An ultrasound approach to localization of fiducial markers for interactive image-guided neurosurgery. Part II: Implementation and automation. IEEE Trans Biomed Eng 45:631–641CrossRefPubMed
199.
go back to reference Schröder HW, Gaab MR (1999) Endoscopic aqueductoplasty: technique and results. Neurosurgery 45:508–515PubMed Schröder HW, Gaab MR (1999) Endoscopic aqueductoplasty: technique and results. Neurosurgery 45:508–515PubMed
200.
go back to reference Schul C, Wassermann H, Skopp GB, Marinov M, Wolfer J, Schuierer G, Joos U, Willich N (1998) Surgical management of intraosseous skull base tumors with aid of operating arm system. Comput Aided Surg 3:312–319CrossRefPubMed Schul C, Wassermann H, Skopp GB, Marinov M, Wolfer J, Schuierer G, Joos U, Willich N (1998) Surgical management of intraosseous skull base tumors with aid of operating arm system. Comput Aided Surg 3:312–319CrossRefPubMed
201.
go back to reference Smith KP, Frank KJ, Bucholz RD (1994) The neurostation—a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imaging Graph 18:247–256PubMed Smith KP, Frank KJ, Bucholz RD (1994) The neurostation—a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imaging Graph 18:247–256PubMed
202.
go back to reference Schulder M, Maldjian JA, Liu WC, Mun IK, Carmel PW (1997) Functional MRI-guided surgery of intracranial tumors. Stereotact Funct Neurosurg 68:98–105PubMed Schulder M, Maldjian JA, Liu WC, Mun IK, Carmel PW (1997) Functional MRI-guided surgery of intracranial tumors. Stereotact Funct Neurosurg 68:98–105PubMed
203.
go back to reference Schulder M, Fontana P, Lavenhar MA, Carmel PW (1999) The relationship of imaging techniques to the accuracy of frameless stereotaxy. Stereotact Funct Neurosurg 72:136–141CrossRefPubMed Schulder M, Fontana P, Lavenhar MA, Carmel PW (1999) The relationship of imaging techniques to the accuracy of frameless stereotaxy. Stereotact Funct Neurosurg 72:136–141CrossRefPubMed
204.
go back to reference Selesnick SH, Kacker A (1999) Image-guided surgical navigation in otology and neurotology. Am J Otol 20:688–693PubMed Selesnick SH, Kacker A (1999) Image-guided surgical navigation in otology and neurotology. Am J Otol 20:688–693PubMed
205.
go back to reference Sipos EP, Tebo SA, Zinreich SJ, Long DM, Brem H (1996) In vivo accuracy testing and clinical experience with the ISG viewing wand. Neurosurgery 39:194–202PubMed Sipos EP, Tebo SA, Zinreich SJ, Long DM, Brem H (1996) In vivo accuracy testing and clinical experience with the ISG viewing wand. Neurosurgery 39:194–202PubMed
206.
go back to reference Spetzger U, Laborde G, Gilsbach JM (1995) Frameless neuronavigation in modern neurosurgery. Minim Invas Neurosurg 38:163–166 Spetzger U, Laborde G, Gilsbach JM (1995) Frameless neuronavigation in modern neurosurgery. Minim Invas Neurosurg 38:163–166
207.
go back to reference Spiegel EA, Wycis HT, Marks M, Lee AJ (1947) Stereotactic apparatus for operations on the human brain. Science 106:349–350 Spiegel EA, Wycis HT, Marks M, Lee AJ (1947) Stereotactic apparatus for operations on the human brain. Science 106:349–350
208.
go back to reference Spiegel EA, Wycis HT (1952) Stereoencephalotomy. Methods and stereotactic atlas of human brain. Grune and Stratton, New York Spiegel EA, Wycis HT (1952) Stereoencephalotomy. Methods and stereotactic atlas of human brain. Grune and Stratton, New York
209.
go back to reference Talairach J, Hecaen H, David M, Monnier M, De Ajuriaguerra J (1949) Recherches sur la coagulation therapeutique des structures sous-corticales chez l'homme. Rev Neurol 81:4–24 Talairach J, Hecaen H, David M, Monnier M, De Ajuriaguerra J (1949) Recherches sur la coagulation therapeutique des structures sous-corticales chez l'homme. Rev Neurol 81:4–24
210.
go back to reference Tanaka T, Olivier A, Hashizume K, Hodozuka A, Nakai H (1999) Image-guided epilepsy surgery. Neurol Med Chir (Tokyo) 39:895–900 Tanaka T, Olivier A, Hashizume K, Hodozuka A, Nakai H (1999) Image-guided epilepsy surgery. Neurol Med Chir (Tokyo) 39:895–900
211.
go back to reference Taren J, Ross D, Lu Y, Harmon L (1995) 3D laser scanning for image guided stereotactic neurosurgery. Acta Neurochir Suppl (Wien) 64:45–48 Taren J, Ross D, Lu Y, Harmon L (1995) 3D laser scanning for image guided stereotactic neurosurgery. Acta Neurochir Suppl (Wien) 64:45–48
212.
go back to reference Tebo SA, Leopold DA, Long DM (1996) An optical digitizer for frameless stereotactic surgery. IEEE Comput Graph Applicat 16:55–64CrossRef Tebo SA, Leopold DA, Long DM (1996) An optical digitizer for frameless stereotactic surgery. IEEE Comput Graph Applicat 16:55–64CrossRef
213.
go back to reference Thomas DGT, Doward NL, Kingsley D, Kitchen ND, Palmer JD, Alberti O, Velani B, Hawkes D, Zhao J, Dijkstra A, Gieles P, Buurman J, Gerritsen FA (1997) Clinical experience with the easy guide neuronavigation system. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 757–760 Thomas DGT, Doward NL, Kingsley D, Kitchen ND, Palmer JD, Alberti O, Velani B, Hawkes D, Zhao J, Dijkstra A, Gieles P, Buurman J, Gerritsen FA (1997) Clinical experience with the easy guide neuronavigation system. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 757–760
214.
go back to reference Tronnier VM, Wirtz CR, Knauth M, Lenz G, Pastyr O, Bonsanto MM, Albert FK, Kuth R, Staubert A, Schlegel W, Sartor K, Kunze S (1997) Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery. Neurosurgery 40:891–902PubMed Tronnier VM, Wirtz CR, Knauth M, Lenz G, Pastyr O, Bonsanto MM, Albert FK, Kuth R, Staubert A, Schlegel W, Sartor K, Kunze S (1997) Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery. Neurosurgery 40:891–902PubMed
215.
go back to reference Uematsu S, Lesser R, Fisher RS, Gordon B, Hara K, Kraus GL, Vining EP, Webber RW (1992) Motor and sensory cortex in humans: topography studied with chronic subdural stimulation. Neurosurgery 31:59–72PubMed Uematsu S, Lesser R, Fisher RS, Gordon B, Hara K, Kraus GL, Vining EP, Webber RW (1992) Motor and sensory cortex in humans: topography studied with chronic subdural stimulation. Neurosurgery 31:59–72PubMed
216.
go back to reference Ungersboeck K, Aichholzer M, Günthner M, Rössler K, Görzer H, Koos WT (1997) Cavernous malformations: from frame-based to frameless stereotactic localization. Minim Invasive Neurosurg 40:134–138PubMed Ungersboeck K, Aichholzer M, Günthner M, Rössler K, Görzer H, Koos WT (1997) Cavernous malformations: from frame-based to frameless stereotactic localization. Minim Invasive Neurosurg 40:134–138PubMed
217.
go back to reference van Herk M, Kooy HM (1994) Automatic three dimensional correlation of CT-CT, CT-MRI, CT-SPECT using chamfer matching. Med Phys 21:1163–1178PubMed van Herk M, Kooy HM (1994) Automatic three dimensional correlation of CT-CT, CT-MRI, CT-SPECT using chamfer matching. Med Phys 21:1163–1178PubMed
218.
219.
go back to reference van Roost D, Schaller C, Meyer B, Schramm J (1997) Can neuronavigation contribute to standardization of selective amygdalohippocampectomy? Stereotact Funct Neurosurg 69:239–242 van Roost D, Schaller C, Meyer B, Schramm J (1997) Can neuronavigation contribute to standardization of selective amygdalohippocampectomy? Stereotact Funct Neurosurg 69:239–242
220.
go back to reference Villalobos H, Germano IM (1999) Clinical evaluation of multimodality registration in frameless stereotaxy. Comput Aided Surg 4:45–49CrossRefPubMed Villalobos H, Germano IM (1999) Clinical evaluation of multimodality registration in frameless stereotaxy. Comput Aided Surg 4:45–49CrossRefPubMed
221.
go back to reference Vrionis FD, Foley KT, Robertson JH, Shea JJ (1997) Use of cranial surface anatomic fiducials for interactive image-guided navigation in the temporal bone: a cadaveric study. Neurosurgery 40:755–763PubMed Vrionis FD, Foley KT, Robertson JH, Shea JJ (1997) Use of cranial surface anatomic fiducials for interactive image-guided navigation in the temporal bone: a cadaveric study. Neurosurgery 40:755–763PubMed
222.
go back to reference Wadley JP, Dorward NL, Breeuwer M, Gerritsen FA, Kitchen ND, Thomas DGT (1998) Neuronavigation in 210 cases: further development of applications and full integration into contemporary neurosurgical practice. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 635–640 Wadley JP, Dorward NL, Breeuwer M, Gerritsen FA, Kitchen ND, Thomas DGT (1998) Neuronavigation in 210 cases: further development of applications and full integration into contemporary neurosurgical practice. In: Lemke HU, Vannier MW, Inamura K, Farman A (eds) CAR 98. Elsevier, Amsterdam, pp 635–640
223.
go back to reference Wadley J, Kitchen N, Thomas D (1999) Image-guided neurosurgery. Hosp Med 60:34–38PubMed Wadley J, Kitchen N, Thomas D (1999) Image-guided neurosurgery. Hosp Med 60:34–38PubMed
224.
go back to reference Wadley J, Dorward N, Kitchen N, Thomas D (1999) Preoperative and intraoperative guidance in modern neurosurgery: a review of 300 cases. Ann R Coll Surg Engl 81:217–225 Wadley J, Dorward N, Kitchen N, Thomas D (1999) Preoperative and intraoperative guidance in modern neurosurgery: a review of 300 cases. Ann R Coll Surg Engl 81:217–225
225.
go back to reference Wagner W, Tschiltschke W, Niendorf WR, Schroeder HWS, Gaab MR (1997) Infrared-based neuronavigation and cortical motor stimulation in the management of central-region tumours. Stereotact Funct Neurosurg 68:112–116PubMed Wagner W, Tschiltschke W, Niendorf WR, Schroeder HWS, Gaab MR (1997) Infrared-based neuronavigation and cortical motor stimulation in the management of central-region tumours. Stereotact Funct Neurosurg 68:112–116PubMed
226.
go back to reference Wagner W, Gaab MR, Schroeder HW, Sehl U, Tschiltschke W (1999) Experiences with cranial neuronavigation in pediatric neurosurgery. Pediatr Neurosurg 31:231–236PubMed Wagner W, Gaab MR, Schroeder HW, Sehl U, Tschiltschke W (1999) Experiences with cranial neuronavigation in pediatric neurosurgery. Pediatr Neurosurg 31:231–236PubMed
227.
go back to reference Warnick R (1997) The cost-effectiveness of image-guided craniotomy for metastatic brain tumors workshop. November 8–10, Mainz (personal communication) Warnick R (1997) The cost-effectiveness of image-guided craniotomy for metastatic brain tumors workshop. November 8–10, Mainz (personal communication)
228.
go back to reference Wells TH, Cosman ER, Ball RE (1987) The Brown-Roberts-Wells (BRW) arc: its concept as a spatial navigation system. Appl Neurophysiol 50:127–132PubMed Wells TH, Cosman ER, Ball RE (1987) The Brown-Roberts-Wells (BRW) arc: its concept as a spatial navigation system. Appl Neurophysiol 50:127–132PubMed
229.
go back to reference Wang MY, Maurer CR Jr, Fitzpatrick JM, Maciunas RJ (1996) An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head. IEEE Trans Biomed Eng 43:627–637CrossRefPubMed Wang MY, Maurer CR Jr, Fitzpatrick JM, Maciunas RJ (1996) An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head. IEEE Trans Biomed Eng 43:627–637CrossRefPubMed
230.
go back to reference Watanabe E, Watanabe T, Manaka S, Mayanagi Y, Takakura K (1987) Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotactic surgery. Surg Neurol 27:543–547PubMed Watanabe E, Watanabe T, Manaka S, Mayanagi Y, Takakura K (1987) Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotactic surgery. Surg Neurol 27:543–547PubMed
231.
go back to reference Watanabe E, Mayanagi Y, Kosugi Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm. Neurosurgery 28:792–800PubMed Watanabe E, Mayanagi Y, Kosugi Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm. Neurosurgery 28:792–800PubMed
232.
go back to reference Westermann B, Hauser R (1997) Precise tracking of an operating microscope for intranasal image guided surgery: improved accuracy with a laser-supported method. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 878–883 Westermann B, Hauser R (1997) Precise tracking of an operating microscope for intranasal image guided surgery: improved accuracy with a laser-supported method. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 878–883
233.
go back to reference Westermann B, Hauser R (1996) Non-invasive 3D patient registration for image-guided skull base surgery. Comput Graph 20:793–799CrossRef Westermann B, Hauser R (1996) Non-invasive 3D patient registration for image-guided skull base surgery. Comput Graph 20:793–799CrossRef
234.
go back to reference Westermann B, Trippel M, Reinhardt H (1995) Optically navigable operating microscope for image-guided surgery. Minim Invas Neurosurg 38:112–116 Westermann B, Trippel M, Reinhardt H (1995) Optically navigable operating microscope for image-guided surgery. Minim Invas Neurosurg 38:112–116
235.
go back to reference Wichmann MW (1967) The use of optical feedback in computer control of an arm. Standford Artificial Intelligence Laboratory, Standford University, AIM 56 Wichmann MW (1967) The use of optical feedback in computer control of an arm. Standford Artificial Intelligence Laboratory, Standford University, AIM 56
236.
go back to reference Wirtz CR, Tronnier VM, Bonsanto MM, Knauth M, Staubert A, Kunze S (1997) Image-guided neurosurgery with intraoperative MRI: update of frameless stereotaxy and radicality control. Stereotact Funct Neurosurg 68:39–43PubMed Wirtz CR, Tronnier VM, Bonsanto MM, Knauth M, Staubert A, Kunze S (1997) Image-guided neurosurgery with intraoperative MRI: update of frameless stereotaxy and radicality control. Stereotact Funct Neurosurg 68:39–43PubMed
237.
go back to reference Wirtz CR, Tronnier VM, Bonsanto MM, Hassfeld S, Knauth M, Kunze S (1998) Neuronavigation. Methods and prospects. Nervenarzt 69:1029–1036CrossRefPubMed Wirtz CR, Tronnier VM, Bonsanto MM, Hassfeld S, Knauth M, Kunze S (1998) Neuronavigation. Methods and prospects. Nervenarzt 69:1029–1036CrossRefPubMed
238.
go back to reference Wirtz CR, Knauth M, Hassfeld S, Tronnier VM, Albert FK, Bonsanto MM, Kunze S (1998) Neuronavigation. First experiences with three different commercially available systems. Zentralbl Neurochir 59:14–22PubMed Wirtz CR, Knauth M, Hassfeld S, Tronnier VM, Albert FK, Bonsanto MM, Kunze S (1998) Neuronavigation. First experiences with three different commercially available systems. Zentralbl Neurochir 59:14–22PubMed
239.
go back to reference Wolf M, Heissler E, Wust P, Beier J, Stahl H, Felix R, Bier J (1997) Test of navigation systems for image-guided implantation of catheters. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 909–913 Wolf M, Heissler E, Wust P, Beier J, Stahl H, Felix R, Bier J (1997) Test of navigation systems for image-guided implantation of catheters. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 909–913
240.
go back to reference Wurm G, Wies W, Schnizer M, Trenkler J, Holl K (2000) Advanced surgical approach for selective amygdalohippocampectomy through neuronavigation. Neurosurgery 46:1377–1382PubMed Wurm G, Wies W, Schnizer M, Trenkler J, Holl K (2000) Advanced surgical approach for selective amygdalohippocampectomy through neuronavigation. Neurosurgery 46:1377–1382PubMed
241.
go back to reference Yasargil MG (1984) Microneurosurgery, vol 1. Thieme, Stuttgart Yasargil MG (1984) Microneurosurgery, vol 1. Thieme, Stuttgart
242.
go back to reference Yasargil MG (1984) Microneurosurgery, vol 2. Thieme, Stuttgart Yasargil MG (1984) Microneurosurgery, vol 2. Thieme, Stuttgart
243.
go back to reference Yasargil MG (1987) Microneurosurgery, vol 3A. Thieme, Stuttgart Yasargil MG (1987) Microneurosurgery, vol 3A. Thieme, Stuttgart
244.
go back to reference Yasargil MG (1988) Microneurosurgery, vol 3B. Thieme, Stuttgart Yasargil MG (1988) Microneurosurgery, vol 3B. Thieme, Stuttgart
245.
go back to reference Yasargil MG (1994) Microneurosurgery, vol 4A. Thieme, Stuttgart Yasargil MG (1994) Microneurosurgery, vol 4A. Thieme, Stuttgart
246.
go back to reference Yasargil MG (1996) Microneurosurgery, vol 4B. Thieme, Stuttgart Yasargil MG (1996) Microneurosurgery, vol 4B. Thieme, Stuttgart
247.
go back to reference Young RF (1987) Application of robotics to stereotactic neurosurgery. Neurol Res 9:123–128PubMed Young RF (1987) Application of robotics to stereotactic neurosurgery. Neurol Res 9:123–128PubMed
248.
go back to reference Zamorano L, Nolte LP, Kadi AM (1993) Interactive intraoperative localization using infrared-based system. Neurol Res 15:290–298PubMed Zamorano L, Nolte LP, Kadi AM (1993) Interactive intraoperative localization using infrared-based system. Neurol Res 15:290–298PubMed
249.
go back to reference Zamorano L, Jiang C, Chavantes C, Diaz FG (1999) Stereotactic and interactive image-guided neuroendoscopy. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 311–320 Zamorano L, Jiang C, Chavantes C, Diaz FG (1999) Stereotactic and interactive image-guided neuroendoscopy. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme, New York, pp 311–320
250.
go back to reference Zeilenhofer HF, Krol Z, Sader R, Hoffmann KH, Hogg M, Schwaiger M, Gerhardt P, Horch HH (1997) Multimodal images in diagnostics of head and neck area using efficient registration and visualization methods. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 723–728 Zeilenhofer HF, Krol Z, Sader R, Hoffmann KH, Hogg M, Schwaiger M, Gerhardt P, Horch HH (1997) Multimodal images in diagnostics of head and neck area using efficient registration and visualization methods. In: Lemke HU, Vannier MW, Inamura K (eds) CAR 97. Elsevier, Amsterdam, pp 723–728
251.
go back to reference Zernov DN (1890) L'encephalometrie. Rev Gen Clin Ther 19:302 Zernov DN (1890) L'encephalometrie. Rev Gen Clin Ther 19:302
252.
go back to reference Zinreich SJ, Tebo SA, Long DM, Brem H, Mattox DE, Loury ME, Van der Kolk CA, Koch WM, Kennedy DW, Bryan RN (1993) Frameless stereotactic integration of CT imaging data: accuracy and initial applications. Radiology 188:735–742PubMed Zinreich SJ, Tebo SA, Long DM, Brem H, Mattox DE, Loury ME, Van der Kolk CA, Koch WM, Kennedy DW, Bryan RN (1993) Frameless stereotactic integration of CT imaging data: accuracy and initial applications. Radiology 188:735–742PubMed
Metadata
Title
Computer-aided navigation in neurosurgery
Authors
P. Grunert
K. Darabi
J. Espinosa
R. Filippi
Publication date
01-05-2003
Publisher
Springer-Verlag
Published in
Neurosurgical Review / Issue 2/2003
Print ISSN: 0344-5607
Electronic ISSN: 1437-2320
DOI
https://doi.org/10.1007/s10143-003-0262-0

Other articles of this Issue 2/2003

Neurosurgical Review 2/2003 Go to the issue

Announcements

May 2003