Skip to main content
Top
Published in: Emergency Radiology 6/2007

01-03-2007 | Original Article

Yield and utility of radiographic “shunt series” in the evaluation of ventriculo-peritoneal shunt malfunction in adult emergency patients

Authors: Richard T. Griffey, Stephen Ledbetter, Ramin Khorasani

Published in: Emergency Radiology | Issue 6/2007

Login to get access

Abstract

We examined the yield and utility of shunt series (SS) performed for suspected shunt malfunction and whether an abnormal SS lead to shunt revision when head computed tomography (CT) was normal or unchanged. We reviewed medical records for all adult emergency patients over a 34-month period with suspected shunt malfunction imaged with both SS and head CT to determine whether a shunt revision was performed contemporaneous with imaging. Nine (3.4%) abnormal SS were identified among 263 studies performed. Among the 192 cases in which CT was normal or unchanged, two patients with abnormal SS underwent contemporaneous shunt revision. Yield of SS is very low, and in the presence of a normal or unchanged head CT, SS provides the imaging basis for contemporaneous shunt revision in 1% (2/192) of cases.
Literature
1.
go back to reference Hunter TB et al (2004) Medical devices of the head, neck, and spine. Radiographics 24(1):257–285, Jan–FebPubMedCrossRef Hunter TB et al (2004) Medical devices of the head, neck, and spine. Radiographics 24(1):257–285, Jan–FebPubMedCrossRef
2.
go back to reference Gilbreath PL, Mulligan ME, Sileo DR (1999) Utilization and cost effectiveness review of SS to rule out ventriculoperitoneal shunt malfunction. Emerg Radiol 6:345–349, DecCrossRef Gilbreath PL, Mulligan ME, Sileo DR (1999) Utilization and cost effectiveness review of SS to rule out ventriculoperitoneal shunt malfunction. Emerg Radiol 6:345–349, DecCrossRef
3.
go back to reference Zorc JJ, Krugman SD, Ogborn J, Benson J (2002) Radiographic evaluation for suspected cerebrospinal fluid shunt obstruction. Pediatr Emerg Care 18(5):337–340, OctPubMedCrossRef Zorc JJ, Krugman SD, Ogborn J, Benson J (2002) Radiographic evaluation for suspected cerebrospinal fluid shunt obstruction. Pediatr Emerg Care 18(5):337–340, OctPubMedCrossRef
4.
go back to reference Iskandar BJ, McLaughlin C, Mapstone TB et al (1998) Pitfalls in the diagnosis of ventricular shunt dysfunction: radiology reports and ventricular size. Pediatrics 101:1031–1036PubMedCrossRef Iskandar BJ, McLaughlin C, Mapstone TB et al (1998) Pitfalls in the diagnosis of ventricular shunt dysfunction: radiology reports and ventricular size. Pediatrics 101:1031–1036PubMedCrossRef
5.
go back to reference Murtagh FR, Quencer RM, Poole CA (1979) Cerebrospinal fluid shunt function and hydrocephalus in the pediatric age group. Radiology 132:385–388PubMed Murtagh FR, Quencer RM, Poole CA (1979) Cerebrospinal fluid shunt function and hydrocephalus in the pediatric age group. Radiology 132:385–388PubMed
Metadata
Title
Yield and utility of radiographic “shunt series” in the evaluation of ventriculo-peritoneal shunt malfunction in adult emergency patients
Authors
Richard T. Griffey
Stephen Ledbetter
Ramin Khorasani
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
Emergency Radiology / Issue 6/2007
Print ISSN: 1070-3004
Electronic ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-006-0557-x

Other articles of this Issue 6/2007

Emergency Radiology 6/2007 Go to the issue