Skip to main content
Top
Published in: Lasers in Medical Science 4/2012

01-07-2012 | Original Article

Effects of different application durations of scanning laser method on debonding strength of laminate veneers

Authors: Mehmet Oguz Oztoprak, Murat Tozlu, Ufuk Iseri, Feyza Ulkur, Tulin Arun

Published in: Lasers in Medical Science | Issue 4/2012

Login to get access

Abstract

Porcelain laminate veneers as esthetic and minimally invasive restorations are being used as an alternative to full veneer crowns. However, the removal of porcelain veneers that have failed may be an uncomfortable and time-consuming procedure because of the high bond strength between the porcelain laminate veneers and the tooth surface. The purpose of this study was to prepare a simple and reliable method for porcelain laminate veneer debonding by using an Er:YAG laser with the scanning method and to determine the amount of lasing time required. Eighty cylindrical specimens with a thickness of 0.7 mm and a diameter of 5 mm were fabricated from Empress II ceramic material. They were cemented on the labial surface of extracted bovine mandibular incisors using Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein) and light cured for 40 s. The specimens were randomly divided into four groups of 20. The first group was assigned as the control group and no laser application was performed. The Er:YAG laser was applied on each specimen in the other three study groups for 3, 6, and 9 s by using the scanning method. One second after the lasing, a mechanical force was applied to remove the laminate veneers by using an Instron Universal Testing machine. Results of this study exhibited statistically significant differences between the control group and the three study groups. Intergroup comparison of shear bond strengths of the three study groups showed a statistically significant difference (p = 0.0001). This study showed that all three application times of Er-YAG laser were effective for debonding ceramic laminate veneers by softening the adhesive resin.
Literature
1.
go back to reference Shaini FJ, Shortall AC, Marquis PM (1997) Clinical performance of porcelain laminate veneers. A retrospective evaluation over a period of 6.5 years. J Oral Rehabil 24:553–559PubMedCrossRef Shaini FJ, Shortall AC, Marquis PM (1997) Clinical performance of porcelain laminate veneers. A retrospective evaluation over a period of 6.5 years. J Oral Rehabil 24:553–559PubMedCrossRef
2.
go back to reference Dunne SM, Millar BJ (1993) A longitudinal study of the clinical performance of porcelain veneers. Br Dent J 175:317–321PubMedCrossRef Dunne SM, Millar BJ (1993) A longitudinal study of the clinical performance of porcelain veneers. Br Dent J 175:317–321PubMedCrossRef
3.
4.
go back to reference Tocchio RM, Williams PT, Mayer FS, Standing KG (1993) Laser debonding of ceramic orthodontic brackets. Am J Orthod Dentofac Orthop 103:155–162CrossRef Tocchio RM, Williams PT, Mayer FS, Standing KG (1993) Laser debonding of ceramic orthodontic brackets. Am J Orthod Dentofac Orthop 103:155–162CrossRef
5.
go back to reference Strobl K, Bahns TL, Willham L, Bishara SE, Stwalley WC (1992) Laser-aided debonding of orthodontic ceramic brackets. Am J Orthod Dentofac Orthop 101:152–158CrossRef Strobl K, Bahns TL, Willham L, Bishara SE, Stwalley WC (1992) Laser-aided debonding of orthodontic ceramic brackets. Am J Orthod Dentofac Orthop 101:152–158CrossRef
6.
go back to reference Obata A, Tsumura T, Niwa K, Ashizawa Y, Deguchi T, Ito M (1999) Super pulse CO2 laser for bracket bonding and debonding. Eur J Orthod 21:193–198PubMedCrossRef Obata A, Tsumura T, Niwa K, Ashizawa Y, Deguchi T, Ito M (1999) Super pulse CO2 laser for bracket bonding and debonding. Eur J Orthod 21:193–198PubMedCrossRef
7.
go back to reference Oztoprak MO, Nalbantgil D, Erdem AS, Tozlu M, Arun T (2010) Debonding of ceramic brackets by a new scanning laser method. Am J Orthod Dentofac Orthop 138:195–200CrossRef Oztoprak MO, Nalbantgil D, Erdem AS, Tozlu M, Arun T (2010) Debonding of ceramic brackets by a new scanning laser method. Am J Orthod Dentofac Orthop 138:195–200CrossRef
8.
go back to reference Nalbantgil D, Oztoprak MO, Tozlu M, Arun T (2010) Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding. Lasers Med Sci. doi:10.1007/s10103-010-0796-7 Nalbantgil D, Oztoprak MO, Tozlu M, Arun T (2010) Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding. Lasers Med Sci. doi:10.​1007/​s10103-010-0796-7
9.
go back to reference Dostalova T, Jelinkova H, Sulc J, Nemec M, Jelinek M, Fibrich M, Michalik P, Miyagi M, Seydlova M (2011) Ceramic bracket debonding by Tm:YAP laser irradiation. Photomed Laser Surg 29:477–484PubMedCrossRef Dostalova T, Jelinkova H, Sulc J, Nemec M, Jelinek M, Fibrich M, Michalik P, Miyagi M, Seydlova M (2011) Ceramic bracket debonding by Tm:YAP laser irradiation. Photomed Laser Surg 29:477–484PubMedCrossRef
10.
go back to reference Feldon PJ, Murray PE, Burch JG, Meister M, Freedmand MA (2010) Diode laser debonding of ceramic brackets. Am J Orthod Dentofac Orthop 138:458–462CrossRef Feldon PJ, Murray PE, Burch JG, Meister M, Freedmand MA (2010) Diode laser debonding of ceramic brackets. Am J Orthod Dentofac Orthop 138:458–462CrossRef
11.
go back to reference Tehranchi A, Fekrazad R, Zafar M, Eslami B, Kalhori KM, Gutknecht N (2010) Evaluation of the effects of CO2 laser on debonding of orthodontics porcelain brackets vs. the conventional method. Lasers Med Sci. doi:10.1007/s10103-010-0820-y Tehranchi A, Fekrazad R, Zafar M, Eslami B, Kalhori KM, Gutknecht N (2010) Evaluation of the effects of CO2 laser on debonding of orthodontics porcelain brackets vs. the conventional method. Lasers Med Sci. doi:10.​1007/​s10103-010-0820-y
13.
go back to reference Nakamichi I, Iwaku M, Fusayama T (1983) Bovine teeth as possible substitutes in the adhesion test. J Dent Res 62:1076–1081PubMedCrossRef Nakamichi I, Iwaku M, Fusayama T (1983) Bovine teeth as possible substitutes in the adhesion test. J Dent Res 62:1076–1081PubMedCrossRef
14.
go back to reference Smith HZ, Casko JS, Leinfelder KF, Utley JD (1976) Comparison of orthodontic bracket bond strengths: human vs bovine enamel. J Dent Res 55:B-153, Abstr. 367 Smith HZ, Casko JS, Leinfelder KF, Utley JD (1976) Comparison of orthodontic bracket bond strengths: human vs bovine enamel. J Dent Res 55:B-153, Abstr. 367
15.
go back to reference Strassler HE, Nathanson D (1989) Clinical evaluation of etched porcelain veneers over a period of 18 to 42 months. J Esthet Dent 1:21–28PubMedCrossRef Strassler HE, Nathanson D (1989) Clinical evaluation of etched porcelain veneers over a period of 18 to 42 months. J Esthet Dent 1:21–28PubMedCrossRef
16.
go back to reference Kihn PW, Barnes DM (1998) The clinical evaluation of porcelain veneers: a 48-month clinical evaluation. JADA 129:747–752PubMed Kihn PW, Barnes DM (1998) The clinical evaluation of porcelain veneers: a 48-month clinical evaluation. JADA 129:747–752PubMed
17.
go back to reference Calamia JR (1989) Clinical evaluation of etched porcelain veneers. Am J Dent 2:9–15PubMed Calamia JR (1989) Clinical evaluation of etched porcelain veneers. Am J Dent 2:9–15PubMed
18.
go back to reference Stacey GD (1993) A shear stress analysis of the bonding of porcelain veneers to enamel. J Prosthet Dent 70:395–402PubMedCrossRef Stacey GD (1993) A shear stress analysis of the bonding of porcelain veneers to enamel. J Prosthet Dent 70:395–402PubMedCrossRef
19.
go back to reference Wigdor H, Abt E, Ashrafi S, Walsh JT (1993) The effect of lasers on dental hard tissues. J Am Dent Assoc 124:65–70PubMed Wigdor H, Abt E, Ashrafi S, Walsh JT (1993) The effect of lasers on dental hard tissues. J Am Dent Assoc 124:65–70PubMed
20.
go back to reference Mehl A, Kremers L, Salzmann K, Hickel R (1997) 3D volume-ablation rate and thermal side effects with the Er:YAG and Nd:YAG laser. Dent Mater 13:246–251PubMedCrossRef Mehl A, Kremers L, Salzmann K, Hickel R (1997) 3D volume-ablation rate and thermal side effects with the Er:YAG and Nd:YAG laser. Dent Mater 13:246–251PubMedCrossRef
21.
go back to reference Chirila TV, Constable IJ, van Saarloos PP, Barrett GD (1990) Laser-induced damage to transparent polymers: chemical effect of short-pulsed (Q-switched) Nd:YAG laser radiation on ophthalmic acrylic biomaterials: I: a review. Biomater 11:305–312CrossRef Chirila TV, Constable IJ, van Saarloos PP, Barrett GD (1990) Laser-induced damage to transparent polymers: chemical effect of short-pulsed (Q-switched) Nd:YAG laser radiation on ophthalmic acrylic biomaterials: I: a review. Biomater 11:305–312CrossRef
Metadata
Title
Effects of different application durations of scanning laser method on debonding strength of laminate veneers
Authors
Mehmet Oguz Oztoprak
Murat Tozlu
Ufuk Iseri
Feyza Ulkur
Tulin Arun
Publication date
01-07-2012
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 4/2012
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-011-0959-1

Other articles of this Issue 4/2012

Lasers in Medical Science 4/2012 Go to the issue