Published in: Journal of Artificial Organs 2/2011

01-06-2011 | Original Article

Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device

Authors: Wei Shi, Itsuro Saito, Takashi Isoyama, Hidemoto Nakagawa, Yusuke Inoue, Toshiya Ono, Akimasa Kouno, Kou Imachi, Yusuke Abe

Published in: Journal of Artificial Organs | Issue 2/2011

Login to get access

Abstract

Significant progress in the development of implantable ventricular assist devices using continuous-flow blood pumps has been made recently. However, a control method has not been established. The blood pressure in the inflow cannula (inlet pressure) is one of the candidates for performing an adequate control. This could also provide important information about ventricle sucking. However, no calibration method for an inlet pressure sensor exists. In this study, an automatic calibration algorithm of the inlet pressure sensor from the pressure waveform at the condition of ventricle sucking was proposed. The calibration algorithm was constructed based on the consideration that intrathoracic pressure could be substituted for atmospheric pressure because the lung is open to air. We assumed that the inlet pressure at the releasing point of the sucking would represent the intrathoracic pressure, because the atrial pressure would be low owing to the sucking condition. A special mock circulation system that can reproduce ventricle sucking was developed to validate the calibration algorithm. The calibration algorithm worked well with a maximum SD of 2.1 mmHg for 3-min measurement in the mock circulation system. While the deviation was slightly large for an elaborate calibration, it would still be useful as a primitive calibration. The influence of the respiratory change and other factors as well as the reliability of the calibration value should be investigated with an animal experiment as a next step.
Literature
1.
go back to reference Takatani S, Matsuda H, Hanatani A, Nojiri C, Yamazaki K, Motomura T, Ohuchi K, Sakamoto T, Yamane T. Mechanical circulatory support devices (MCSD) in Japan: current status and future directions. J Artif Organs. 2005;8:13–27.PubMedCrossRef Takatani S, Matsuda H, Hanatani A, Nojiri C, Yamazaki K, Motomura T, Ohuchi K, Sakamoto T, Yamane T. Mechanical circulatory support devices (MCSD) in Japan: current status and future directions. J Artif Organs. 2005;8:13–27.PubMedCrossRef
2.
go back to reference Koul B, Solem JO, Steen S, Casimir-Ahn H, Granfeldt H, Lonn UJ. HeartMate left ventricular assist device as bridge to heart transplantation. Ann Thorac Surg. 1998;65:1625–30.PubMedCrossRef Koul B, Solem JO, Steen S, Casimir-Ahn H, Granfeldt H, Lonn UJ. HeartMate left ventricular assist device as bridge to heart transplantation. Ann Thorac Surg. 1998;65:1625–30.PubMedCrossRef
3.
go back to reference Portner PM, Jansen PG, Oyer PE, Wheeldon DR, Ramasamy N. Improved outcomes with an implantable left ventricular assist system: a multicenter study. Ann Thorac Surg. 2001;71:205–9.PubMedCrossRef Portner PM, Jansen PG, Oyer PE, Wheeldon DR, Ramasamy N. Improved outcomes with an implantable left ventricular assist system: a multicenter study. Ann Thorac Surg. 2001;71:205–9.PubMedCrossRef
4.
go back to reference Mehta SM, Pae WE Jr, Rosenberg G, Snyder AJ, Weiss WJ, Lewis JP, Frank DJ, Thompson JJ, Pierce WS. The LionHeart LVD-2000: a completely implanted left ventricular assist device for chronic circulatory support. Ann Thorac Surg. 2001;71:S156–61. (discussion S183–184).PubMedCrossRef Mehta SM, Pae WE Jr, Rosenberg G, Snyder AJ, Weiss WJ, Lewis JP, Frank DJ, Thompson JJ, Pierce WS. The LionHeart LVD-2000: a completely implanted left ventricular assist device for chronic circulatory support. Ann Thorac Surg. 2001;71:S156–61. (discussion S183–184).PubMedCrossRef
5.
go back to reference Nojiri C, Kijima T, Maekawa J, Horiuchi K, Kido T, Sugiyama T, Mori T, Sugiura N, Asada T, Umemura W, Ozaki T, Suzuki M, Akamatsu T, Westaby S, Katsumata T, Saito S. Development status of Terumo implantable left ventricular assist system. Artif Organs. 2001;25:411–3.PubMedCrossRef Nojiri C, Kijima T, Maekawa J, Horiuchi K, Kido T, Sugiyama T, Mori T, Sugiura N, Asada T, Umemura W, Ozaki T, Suzuki M, Akamatsu T, Westaby S, Katsumata T, Saito S. Development status of Terumo implantable left ventricular assist system. Artif Organs. 2001;25:411–3.PubMedCrossRef
6.
go back to reference Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;50:461–5.PubMedCrossRef Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;50:461–5.PubMedCrossRef
7.
go back to reference Frazier OH, Shah NA, Myers TJ, Robertson KD, Gregoric ID, Delgado R. Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation. Cardiology. 2004;101:111–6.PubMedCrossRef Frazier OH, Shah NA, Myers TJ, Robertson KD, Gregoric ID, Delgado R. Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation. Cardiology. 2004;101:111–6.PubMedCrossRef
8.
go back to reference Chung MK, Zhang N, Tansley GD, Qian Y. Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump. Artif Organs. 2004;28:1089–94.PubMedCrossRef Chung MK, Zhang N, Tansley GD, Qian Y. Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump. Artif Organs. 2004;28:1089–94.PubMedCrossRef
9.
go back to reference Nitta S, Katahira Y, Yambe T, Sonobe T, Hayashi H, Tanaka M, Sato N, Miura M, Mohri H, Esashi M. Micro-pressure sensor for continuous monitoring of a ventricular assist device. Int J Artif Organs. 1990;13:823–9.PubMed Nitta S, Katahira Y, Yambe T, Sonobe T, Hayashi H, Tanaka M, Sato N, Miura M, Mohri H, Esashi M. Micro-pressure sensor for continuous monitoring of a ventricular assist device. Int J Artif Organs. 1990;13:823–9.PubMed
10.
go back to reference Bullister E, Reich S, d’Entremont P, Silverman N, Sluetz J. A blood pressure sensor for long-term implantation. Artif Organs. 2001;25:376–9.PubMedCrossRef Bullister E, Reich S, d’Entremont P, Silverman N, Sluetz J. A blood pressure sensor for long-term implantation. Artif Organs. 2001;25:376–9.PubMedCrossRef
11.
go back to reference Yamagishi H, Sankai Y, Yamane T, Jikuya T, Tsutsui T. Development of built-in type and noninvasive sensor systems for smart artificial heart. ASAIO J. 2003;49:265–70.PubMedCrossRef Yamagishi H, Sankai Y, Yamane T, Jikuya T, Tsutsui T. Development of built-in type and noninvasive sensor systems for smart artificial heart. ASAIO J. 2003;49:265–70.PubMedCrossRef
12.
go back to reference Saito I, Chinzei T, Isoyama T, Miura H, Kouno A, Ono T, Nakagawa H, Yamaguchi-Sekino S, Shi W, Inoue Y, Kishi A, Abe Y. Implementation of the natural heartbeat synchronize control for the undulation pump ventricular assist device using the inflow pressure. IFMBE Proceedings. 2008;19:62–5.CrossRef Saito I, Chinzei T, Isoyama T, Miura H, Kouno A, Ono T, Nakagawa H, Yamaguchi-Sekino S, Shi W, Inoue Y, Kishi A, Abe Y. Implementation of the natural heartbeat synchronize control for the undulation pump ventricular assist device using the inflow pressure. IFMBE Proceedings. 2008;19:62–5.CrossRef
13.
go back to reference Abe Y, Isoyama T, Saito I, Mochizuki S, Ono M, Nakagawa H, Taniguchi N, Mitsumune N, Sugino A, Mitsui M, Takiura K, Ono T, Kouno A, Chinzei T, Takamoto S, Imachi K. Development of mechanical circulatory support device at the University of Tokyo. J Artif Organs. 2007;10:60–70.PubMedCrossRef Abe Y, Isoyama T, Saito I, Mochizuki S, Ono M, Nakagawa H, Taniguchi N, Mitsumune N, Sugino A, Mitsui M, Takiura K, Ono T, Kouno A, Chinzei T, Takamoto S, Imachi K. Development of mechanical circulatory support device at the University of Tokyo. J Artif Organs. 2007;10:60–70.PubMedCrossRef
14.
go back to reference Imachi K, Mabuchi K, Chinzei T, Abe Y, Imanishi K, Yonezawa T, Nozawa H, Isoyama T, Kouno A, Ono T, Atsumi K, Iwao F. The jellyfish valve: a polymer membrane valve for the artificial heart. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 4. Tokyo: Springer; 1993. p. 41–4. Imachi K, Mabuchi K, Chinzei T, Abe Y, Imanishi K, Yonezawa T, Nozawa H, Isoyama T, Kouno A, Ono T, Atsumi K, Iwao F. The jellyfish valve: a polymer membrane valve for the artificial heart. In: Akutsu T, Koyanagi H, editors. Heart replacement—artificial heart 4. Tokyo: Springer; 1993. p. 41–4.
Metadata
Title
Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device
Authors
Wei Shi
Itsuro Saito
Takashi Isoyama
Hidemoto Nakagawa
Yusuke Inoue
Toshiya Ono
Akimasa Kouno
Kou Imachi
Yusuke Abe
Publication date
01-06-2011
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 2/2011
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-011-0556-x

Other articles of this Issue 2/2011

Journal of Artificial Organs 2/2011 Go to the issue