Skip to main content
Top
Published in: Hernia 4/2005

01-12-2005 | Original Article

A prospective study between two different techniques for the repair of a large recurrent ventral hernia: a double mesh intraperitoneal repair versus onlay mesh repair

Author: Raafat Y. Afifi

Published in: Hernia | Issue 4/2005

Login to get access

Abstract

Background: Massive ventral hernias are difficult to repair, especially with multiple recurrences. Numerous methods of repair have been described with an overall recurrence rate up to 33% after first repair and 44% after second repair, mostly occurring within 3 years of the repair. Methods: This is a prospective study on 41 patients who underwent surgery between January 2000 and August 2004 for recurrent large ventral hernias. Patients were randomized into two groups: group A included 22 patients, who were subjected to suture repair with an onlay polypropylene mesh, and group B, which included 19 patients, who were subjected to a tailored double mesh (Vicryl+polypropylene) intraperitoneal repair. Results: Superficial wound infection occurred in two patients (4.8%), one in each group. By a median follow up of 30 months, seroma formation or hernia recurrence was not found in group B in comparison to seven and six cases, respectively, in group A (p≤0.000). There was no intraabdominal complication in the cases subjected to double mesh intraperitoneal repair due to the protective effect of the inner Vicryl layer, which is characterized by its low reactivity. Conclusions: A double mesh intraperitoneal repair (ADMIR) is successful for the repair of recurrent large ventral hernias as it is applicable to all sites of ventral hernias. The mesh is mostly hidden within the abdomen with relatively affordable pain allowing for early mobilization, the complication rate is low and so far no recurrence was reported. A long-term follow up with a larger number of cases is advisable in order to determine the long-term success of this kind of repair.
Literature
1.
go back to reference Temudom T, Siadati M, Sarr MG (1996) Repair of complex giant or recurrent ventral hernias by using tension-free intraperitoneal prosthetic mesh (Stoppa technique): lessons learned from out initial experience (fifty patients). Surgery 120:738–744PubMedCrossRef Temudom T, Siadati M, Sarr MG (1996) Repair of complex giant or recurrent ventral hernias by using tension-free intraperitoneal prosthetic mesh (Stoppa technique): lessons learned from out initial experience (fifty patients). Surgery 120:738–744PubMedCrossRef
2.
go back to reference Sensoz O, Unlu RE, Ortak T, Baran C (2003) The overlap flap: a method of repairing recurrent large abdominal hernias. Plast Reconstr Surg 111:831–836PubMedCrossRef Sensoz O, Unlu RE, Ortak T, Baran C (2003) The overlap flap: a method of repairing recurrent large abdominal hernias. Plast Reconstr Surg 111:831–836PubMedCrossRef
3.
go back to reference Mathes SJ, Steinwald PM, Foster RD, Hoffman WY, Anthony JP (2000) Complex abdominal wall reconstruction: a comparison of flap and mesh closure. Ann Surg 232:586–596CrossRefPubMed Mathes SJ, Steinwald PM, Foster RD, Hoffman WY, Anthony JP (2000) Complex abdominal wall reconstruction: a comparison of flap and mesh closure. Ann Surg 232:586–596CrossRefPubMed
4.
go back to reference DiBello JN, Moore JH (1996) Sliding myofascial flap of the rectus abdominus muscles for the closure of recurrent ventral hernias. Plast Reconstr Surg 98:464–469PubMedCrossRef DiBello JN, Moore JH (1996) Sliding myofascial flap of the rectus abdominus muscles for the closure of recurrent ventral hernias. Plast Reconstr Surg 98:464–469PubMedCrossRef
5.
go back to reference Bauer JJ, Harris MT, Gorfine SR, Kreel I (2002) Rives Stoppa procedure for repair of large incisional hernias: experience with 57 patients. Hernia 6:120–123CrossRefPubMed Bauer JJ, Harris MT, Gorfine SR, Kreel I (2002) Rives Stoppa procedure for repair of large incisional hernias: experience with 57 patients. Hernia 6:120–123CrossRefPubMed
6.
go back to reference Parker HH III, Harris H, Nottingham JM, Bynoe RP, Yost MJ (2002) Laparoscopic repair of large incisional hernias. Am Surg 68:530–534PubMed Parker HH III, Harris H, Nottingham JM, Bynoe RP, Yost MJ (2002) Laparoscopic repair of large incisional hernias. Am Surg 68:530–534PubMed
7.
go back to reference Aura T, Habib E, Mekkaoui M, Brassier D, Elhadad A (2002) Laparoscopic tension-free repair of anterior abdominal wall incisional and ventral hernias with an intraperitoneal Gore-Tex mesh: prospective study and review of the literature. J Laparoendosc Adv Surg Tech 12:263–267CrossRefPubMed Aura T, Habib E, Mekkaoui M, Brassier D, Elhadad A (2002) Laparoscopic tension-free repair of anterior abdominal wall incisional and ventral hernias with an intraperitoneal Gore-Tex mesh: prospective study and review of the literature. J Laparoendosc Adv Surg Tech 12:263–267CrossRefPubMed
8.
go back to reference Luijendijk RW, Hop WCJ, Van den Tol MP, de Lange DC, Braaksma MM, Ijzemans JN, Boelhouver RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Eng J Med 343:392–398CrossRef Luijendijk RW, Hop WCJ, Van den Tol MP, de Lange DC, Braaksma MM, Ijzemans JN, Boelhouver RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. N Eng J Med 343:392–398CrossRef
9.
go back to reference Matapurkar BG, Gupta Ak, Agarwal AK (1991) A new technique of “Marlex-peritoneal sandwich” in the repair of large incisional hernias. World J Surg 1:768–770CrossRef Matapurkar BG, Gupta Ak, Agarwal AK (1991) A new technique of “Marlex-peritoneal sandwich” in the repair of large incisional hernias. World J Surg 1:768–770CrossRef
10.
go back to reference Usher FC (1958) Use of Marlex mesh in the repair of incisional hernia. Am Surg 24:969–974PubMed Usher FC (1958) Use of Marlex mesh in the repair of incisional hernia. Am Surg 24:969–974PubMed
11.
go back to reference Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133:378–382CrossRefPubMed Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133:378–382CrossRefPubMed
12.
go back to reference Loh A, Rajkumar JS, South LM (1992) Anatomical repair of large incisional hernias. Ann R Coll Surg Engl 74:100–105PubMed Loh A, Rajkumar JS, South LM (1992) Anatomical repair of large incisional hernias. Ann R Coll Surg Engl 74:100–105PubMed
13.
go back to reference Liakakos T, Karanikas I (1994) Use of Marlex mesh in the repair of incisional hernias. Br J Surg 81:248–249PubMedCrossRef Liakakos T, Karanikas I (1994) Use of Marlex mesh in the repair of incisional hernias. Br J Surg 81:248–249PubMedCrossRef
14.
go back to reference Becouarn G, Szmil E, Leroux C, Arnaux JP (1996) Surgical care of postoperative incisional hernias with intraperitoneal Dacron grafts. J Chir 133:229–232 Becouarn G, Szmil E, Leroux C, Arnaux JP (1996) Surgical care of postoperative incisional hernias with intraperitoneal Dacron grafts. J Chir 133:229–232
15.
go back to reference Arnaud JP, Cervi C, Tuech JJ, Cattan F (1997) Surgical treatment of post-operative incisional hernias by intra-peritoneal insertion of a Dacron mesh. A report of 220 cases. Hernia 1:97–99CrossRef Arnaud JP, Cervi C, Tuech JJ, Cattan F (1997) Surgical treatment of post-operative incisional hernias by intra-peritoneal insertion of a Dacron mesh. A report of 220 cases. Hernia 1:97–99CrossRef
16.
go back to reference Karakousis CP, Volpe C, Tanski J, Colby ED, Winston J, Driscoll DL (1995) Use of mesh for musculoaponeurotic defects of the abdominal wall in cancer surgery and the risk of bowel fistulas. J Am Coll Surg 181:11–16PubMed Karakousis CP, Volpe C, Tanski J, Colby ED, Winston J, Driscoll DL (1995) Use of mesh for musculoaponeurotic defects of the abdominal wall in cancer surgery and the risk of bowel fistulas. J Am Coll Surg 181:11–16PubMed
17.
go back to reference Mathonnet M, Antarieu S, Gainant A, Preux PM, Boutros-Toni F, Gubertafond P (1998) Postoperative incisional hernia: intra- or extra-peritoneal position of the mesh? Chirurgie 123:154–161CrossRefPubMed Mathonnet M, Antarieu S, Gainant A, Preux PM, Boutros-Toni F, Gubertafond P (1998) Postoperative incisional hernia: intra- or extra-peritoneal position of the mesh? Chirurgie 123:154–161CrossRefPubMed
18.
go back to reference White TJ, Santos MC, Thompson JS (1998) Factors affecting wound complications in repair of ventral hernias. Am Surg 64:276–280PubMed White TJ, Santos MC, Thompson JS (1998) Factors affecting wound complications in repair of ventral hernias. Am Surg 64:276–280PubMed
19.
go back to reference DeGuzman LJ, Nyhus LM, Schlesinger PK (1995) Colocutaneous fistula formation following polypropylene mesh placement for repair of a vental hernia: diagnosis by colonoscopy. Endoscopy 27:459–461PubMedCrossRef DeGuzman LJ, Nyhus LM, Schlesinger PK (1995) Colocutaneous fistula formation following polypropylene mesh placement for repair of a vental hernia: diagnosis by colonoscopy. Endoscopy 27:459–461PubMedCrossRef
20.
go back to reference Molloy RG, Moran KT, Waldron RP, Brady MP, Kirwan WO (1991) Massive incisional hernia: abdominal wall replacement with Marlex mesh. Br J Surg 78:242–244PubMedCrossRef Molloy RG, Moran KT, Waldron RP, Brady MP, Kirwan WO (1991) Massive incisional hernia: abdominal wall replacement with Marlex mesh. Br J Surg 78:242–244PubMedCrossRef
21.
go back to reference Usher FC (1962) Hernia repair with marlex mesh. An analysis of 541 cases. Arch Surg 84:73–76PubMed Usher FC (1962) Hernia repair with marlex mesh. An analysis of 541 cases. Arch Surg 84:73–76PubMed
22.
go back to reference Matapurkar BG, Gupta AK, Agarwal AK (1991) A new technique of “Marlex—peritoneal sandwich” in the repair of large incisional hernias. World J Surg 15:768–770CrossRefPubMed Matapurkar BG, Gupta AK, Agarwal AK (1991) A new technique of “Marlex—peritoneal sandwich” in the repair of large incisional hernias. World J Surg 15:768–770CrossRefPubMed
23.
go back to reference MacLanahan D, Weems C, Novotney M, Gibson K (1997) Retrorectus prosthetic mesh repair of midline abdominal hernia. Am J Surg 173:445–449CrossRefPubMed MacLanahan D, Weems C, Novotney M, Gibson K (1997) Retrorectus prosthetic mesh repair of midline abdominal hernia. Am J Surg 173:445–449CrossRefPubMed
24.
go back to reference Burgard G, Mrmorale A, Guilleret J (1994) Treatment of extensive abdominal incisional hernia with an intraperitoneal plate. A series of 27 patients. J Chir 131:351–354 Burgard G, Mrmorale A, Guilleret J (1994) Treatment of extensive abdominal incisional hernia with an intraperitoneal plate. A series of 27 patients. J Chir 131:351–354
25.
go back to reference Khaira HS, Lall P, Hunter B, Brown JH (2001) Repair of incisional hernias. J R Coll Surg Edinb 46:39–43PubMed Khaira HS, Lall P, Hunter B, Brown JH (2001) Repair of incisional hernias. J R Coll Surg Edinb 46:39–43PubMed
26.
go back to reference Read RC, Yoder G (1989) Recent trends in the management of incisional herniation. Arch Srug 124:485–488 Read RC, Yoder G (1989) Recent trends in the management of incisional herniation. Arch Srug 124:485–488
27.
go back to reference Mudge M, Hughes LE (1985) Incisional hernia: a 10 year prospective study of incidence and attitudes. Br J Surg 72:70–71PubMedCrossRef Mudge M, Hughes LE (1985) Incisional hernia: a 10 year prospective study of incidence and attitudes. Br J Surg 72:70–71PubMedCrossRef
28.
go back to reference Millikan KW, Baptista M, Amin B, Deziel DJ, Doolas A (2003) Intraperitoneal underlay ventral hernia repair utilizing bilayer expanded polytetrafluoroethylene and polypropylene mesh. Am Surg 69:287–291PubMed Millikan KW, Baptista M, Amin B, Deziel DJ, Doolas A (2003) Intraperitoneal underlay ventral hernia repair utilizing bilayer expanded polytetrafluoroethylene and polypropylene mesh. Am Surg 69:287–291PubMed
29.
go back to reference Marchal F, Brunaud L, Sebbag H, Bresler L, Tortuyaux JM, Boissel P (1999) Treatment of incisional hernias by placement of an intraperitoneal prosthesis: a series of 128 patients. Hernia 3:141–147CrossRef Marchal F, Brunaud L, Sebbag H, Bresler L, Tortuyaux JM, Boissel P (1999) Treatment of incisional hernias by placement of an intraperitoneal prosthesis: a series of 128 patients. Hernia 3:141–147CrossRef
Metadata
Title
A prospective study between two different techniques for the repair of a large recurrent ventral hernia: a double mesh intraperitoneal repair versus onlay mesh repair
Author
Raafat Y. Afifi
Publication date
01-12-2005
Publisher
Springer-Verlag
Published in
Hernia / Issue 4/2005
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-005-0017-7

Other articles of this Issue 4/2005

Hernia 4/2005 Go to the issue