Published in:
01-09-2003 | Original Article
Carboxymethylcellulose coated on visceral face of polypropylene mesh prevents adhesion without impairing wound healing in incisional hernia model in rats
Authors:
B. Yelimlieş, A. Alponat, A. Çubukçu, M. Kuru, S. Öz, C. Erçin, N. Gönüllü
Published in:
Hernia
|
Issue 3/2003
Login to get access
Abstract
Adhesions between viscera and mesh may result in intestinal obstruction and fistulae formation. Fewer adhesions with sodium carboxymethylcellulose (SCMC)-coated polypropylene mesh (PM) has been reported, but impaired wound healing was the major concern. We investigated the adhesion-prevention effect of SCMC in different concentrations, as coating only on visceral face of PM and its effects on wound healing. A full-thickness abdominal wall defect was created in 28 rats, which were then divided into three groups. In Group I (control), the defect was repaired with PM only; in Group II and Group III, the defects were repaired with 1% and 1.6% SCMC-coated-PM, respectively. All animals were sacrificed at day 30, and histological evaluation and adhesion scoring were done. Animals in the group in which 1.6% SCMC-coated PM was used developed significantly fewer adhesions compared with other animals (P=0.04). Histological evaluation using a semiquantitative scoring system showed no difference between the groups in fibrosis and inflammation scores (P=0.9 and P=0.3, respectively), and thickness of fibrosis on mesh was also similar (P=0.5). SCMC in 1.6% concentration as coating only on the visceral face of PM reduced the incidence and severity of adhesions without impairing wound healing.