Skip to main content
Top
Published in: Annals of Vascular Surgery 6/2004

01-11-2004 | Papers Presented to the Peripheral Vascular Surgery Society —Winter Meeting

Early Results with Infrainguinal Cutting Balloon Angioplasty Limits Distal Dissection

Authors: Jamal F. Rabbi, MD, Ravi P. Kiran, MD, Gregory Gersten, MD, Stanley J. Dudrick, MD, Alan Dardik, MD, PhD

Published in: Annals of Vascular Surgery | Issue 6/2004

Login to get access

Abstract

Infrainguinal angioplasty has less initial and long-term success compared with more proximal sites. These suboptimal initial technical results may be related to the heavy calcific burden in the femoral and popliteal arteries and, subsequently, higher incidence of distal dissection. Cutting balloon angioplasty (CBA) is a newer technique that is thought to limit distal dissection in heavily calcified vessels; although CBA has been evaluated in the coronary circulation, there are few reports of its use in peripheral vessels. This study evaluates our initial experience with CBA for the management of femoropopliteal disease. Eleven patients underwent infrainguinal CBA for symptomatic limb ischemia at a community hospital. Ten procedures (91%) were technically successful, with no distal dissections, iatrogenic vessel perforations, or surgical target vessel revascularizations. In eight patients available for follow-up, the limb salvage rate was 100% and of seven and eight CBA sites (88%) were still widely patent (mean follow-up, 3 months; range, 2-12 months). This preliminary study suggests that CBA is safe and feasible for electively performed femoropopliteal chronic occlusive disease with acceptable success rates on short-term follow-up. Long-term results and comparison with other endovascular modalities require evaluation.
Literature
1.
go back to reference Stanley, B, Teague, B, Raptis, S, Taylor, DJ, Berce, M 1996Efficacy of balloon angioplasty of the superficial femoral artery and popliteal artery in the relief of leg ischemiaJ. Vasc. Surg.23679685 Stanley, B, Teague, B, Raptis, S, Taylor, DJ, Berce, M 1996Efficacy of balloon angioplasty of the superficial femoral artery and popliteal artery in the relief of leg ischemiaJ. Vasc. Surg.23679685
2.
go back to reference Matsi, PJ, Manninen, HI, Vanninen, RL, et al. 1994Femoropopliteal angioplasty in patients with claudication: primary and secondary patency in 140 limbs with 1 to 3-year follow-upRadiology191727733PubMed Matsi, PJ, Manninen, HI, Vanninen, RL,  et al. 1994Femoropopliteal angioplasty in patients with claudication: primary and secondary patency in 140 limbs with 1 to 3-year follow-upRadiology191727733PubMed
3.
go back to reference Adar, R, Critchfield, GC, Eddy, DM 1989A confidence profile analysis of the results of femoropopliteal percutaneous transluminal angioplasty in the treatment of lower-extremity ischemiaJ. Vasc. Surg.105767CrossRefPubMed Adar, R, Critchfield, GC, Eddy, DM 1989A confidence profile analysis of the results of femoropopliteal percutaneous transluminal angioplasty in the treatment of lower-extremity ischemiaJ. Vasc. Surg.105767CrossRefPubMed
4.
go back to reference Mizuno, K, Jurita, A, Imazeki, N 1984Pathologic finding after percutaneous transluminal angioplastyBr. Heart J.18476484 Mizuno, K, Jurita, A, Imazeki, N 1984Pathologic finding after percutaneous transluminal angioplastyBr. Heart J.18476484
5.
go back to reference Austin, GE, Ratliff, NB, Hollman, J, Tabie, S, Philips, DF 1985Intimal proliferation of smooth muscle cells as an explanation for recurrent coronary artery stenosis after percutaneous transluminal angioplastyJ. Am. Coll. Cardiol.6369375PubMed Austin, GE, Ratliff, NB, Hollman, J, Tabie, S, Philips, DF 1985Intimal proliferation of smooth muscle cells as an explanation for recurrent coronary artery stenosis after percutaneous transluminal angioplastyJ. Am. Coll. Cardiol.6369375PubMed
6.
go back to reference Walker, BF 1989“Crackers, breakers, stretchers, drillers, scrapers, shavers, burners, welders and melters” — the future treatment of atherosclerotic coronary artery disease? A clinical morphologic assessmentJ. Am. Coll. Cardiol.13969987 Walker, BF 1989“Crackers, breakers, stretchers, drillers, scrapers, shavers, burners, welders and melters” — the future treatment of atherosclerotic coronary artery disease? A clinical morphologic assessmentJ. Am. Coll. Cardiol.13969987
7.
go back to reference Zorger, N, Manke, C, Lenhart, M, et al. 2002Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic resultsJ. Vasc. Interv. Radiol.13355359 Zorger, N, Manke, C, Lenhart, M,  et al. 2002Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic resultsJ. Vasc. Interv. Radiol.13355359
8.
go back to reference Izumi, M, Tsuchikane, E, Funamoto, M, et al. 2001Final results of the CAPAS trialAm. Heart J.142782789CrossRefPubMed Izumi, M, Tsuchikane, E, Funamoto, M,  et al. 2001Final results of the CAPAS trialAm. Heart J.142782789CrossRefPubMed
9.
go back to reference Kurbaan, AS, Foale, RA, Sigwart, U 2000Cutting balloon angioplasty for in-stent restenosisCathet. Cardiovasc. Intervent.50480483CrossRef Kurbaan, AS, Foale, RA, Sigwart, U 2000Cutting balloon angioplasty for in-stent restenosisCathet. Cardiovasc. Intervent.50480483CrossRef
10.
go back to reference Martinez, D, Goicolea, J, Alfonzo, F, et al. 1996Intravascular ultrasound findings after cutting balloon angioplasty [abstract]Eur. Heart J.17188 Martinez, D, Goicolea, J, Alfonzo, F,  et al. 1996Intravascular ultrasound findings after cutting balloon angioplasty [abstract]Eur. Heart J.17188
11.
go back to reference Ergene, O, Seyithanoglu, BY, Tastan, A, et al. 1998Comparison of angiographic and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: a randomized trialJ. Invasive Cardiol.107075PubMed Ergene, O, Seyithanoglu, BY, Tastan, A,  et al. 1998Comparison of angiographic and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: a randomized trialJ. Invasive Cardiol.107075PubMed
12.
go back to reference Kondo, T, Kawaguchi, K, Awaji, Y, Mochizuki, M 1997Immediate and chronic results of cutting balloon angioplasty: a matched comparison with conventional angioplastyClin. Cardiol.20459463PubMed Kondo, T, Kawaguchi, K, Awaji, Y, Mochizuki, M 1997Immediate and chronic results of cutting balloon angioplasty: a matched comparison with conventional angioplastyClin. Cardiol.20459463PubMed
13.
go back to reference Engelke, C, Sandhu, C, Morgan, RA, Belli, AM 2002Using 6-mm cutting balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary resultsA.J.R. Am. J. Roentgenol.179619623 Engelke, C, Sandhu, C, Morgan, RA, Belli, AM 2002Using 6-mm cutting balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary resultsA.J.R. Am. J. Roentgenol.179619623
14.
go back to reference Engelke, C, Morgan, RA, Belli, AM 2002Cutting balloon percutaneous transluminal angioplasty for salvage of lower limb arterial bypass grafts: feasibilityRadiology223106114PubMed Engelke, C, Morgan, RA, Belli, AM 2002Cutting balloon percutaneous transluminal angioplasty for salvage of lower limb arterial bypass grafts: feasibilityRadiology223106114PubMed
15.
go back to reference Kasirajan, KM, Schneider, PA 2004Early outcome of “cutting” balloon angioplasty for infrainguinal vein graft stenosisJ. Vasc. Surg.39702708CrossRefPubMed Kasirajan, KM, Schneider, PA 2004Early outcome of “cutting” balloon angioplasty for infrainguinal vein graft stenosisJ. Vasc. Surg.39702708CrossRefPubMed
16.
go back to reference Ansel, GM, Sample, NS, Botti, III CF,Jr, Tracy, AJ, Silver, MJ, Marshall, BJ, George, BS 2004Cutting balloon angioplasty of the popliteal and infrapopliteal vessels for symptomatic limb ischemiaCathet. Cardiovasc. Interv.6414 Ansel, GM, Sample, NS, Botti, III CF,Jr, Tracy, AJ, Silver, MJ, Marshall, BJ, George, BS 2004Cutting balloon angioplasty of the popliteal and infrapopliteal vessels for symptomatic limb ischemiaCathet. Cardiovasc. Interv.6414
17.
go back to reference Bertrand, OF, Mongrain, R, Soualmi, L, et al. 1998Development of coronary aneurysm after cutting balloon angioplasty: assessment by intracoronary ultrasoundCathet. Cardiovasc. Diagn.44449452CrossRefPubMed Bertrand, OF, Mongrain, R, Soualmi, L,  et al. 1998Development of coronary aneurysm after cutting balloon angioplasty: assessment by intracoronary ultrasoundCathet. Cardiovasc. Diagn.44449452CrossRefPubMed
18.
go back to reference Mauri, L, Bonan, R, Weiner, BH, et al. 2002Cutting balloon angioplasty for the prevention of restenosis: results of the Cutting Balloon Global Randomized TrialAm. J. Cardiol.9010791083CrossRefPubMed Mauri, L, Bonan, R, Weiner, BH,  et al. 2002Cutting balloon angioplasty for the prevention of restenosis: results of the Cutting Balloon Global Randomized TrialAm. J. Cardiol.9010791083CrossRefPubMed
19.
go back to reference Ajani, AE, Kim, HS, Castagna, M, et al. 2001Clinical utility of the cutting balloonJ. Invasive Cardiol.13554557PubMed Ajani, AE, Kim, HS, Castagna, M,  et al. 2001Clinical utility of the cutting balloonJ. Invasive Cardiol.13554557PubMed
Metadata
Title
Early Results with Infrainguinal Cutting Balloon Angioplasty Limits Distal Dissection
Authors
Jamal F. Rabbi, MD
Ravi P. Kiran, MD
Gregory Gersten, MD
Stanley J. Dudrick, MD
Alan Dardik, MD, PhD
Publication date
01-11-2004
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 6/2004
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-004-0103-9

Other articles of this Issue 6/2004

Annals of Vascular Surgery 6/2004 Go to the issue

Papers Presented to the Peripheral Vascular Surgery Society—Winter Meeting

Observer Variability of Iliac Artery Measurements in Endovascular Repair of Abdominal Aortic Aneurysms

Papers Presented to the Peripheral Vascular Surgery Society—Winter Meeting

The Surgically Created Arteriovenous Fistula: A Forgotten Alternative to Venous Access