Skip to main content
Top
Published in: Annals of Vascular Surgery 3/2004

01-05-2004 | Original Articles

Computed Tomography and Ultrasound in Follow-up of Patients after Endovascular Repair of Abdominal Aortic Aneurysm

Authors: Stéphane Elkouri, MD, Jean M. Panneton, MD, James C. Andrews, MD, Bradley D. Lewis, MD, Michael A. McKusick, MD, Audra A. Noel, MD, Charles M. Rowland, MS, Thomas C. Bower, MD, Kenneth J. Cherry Jr., MD, Peter Gloviczki, MD

Published in: Annals of Vascular Surgery | Issue 3/2004

Login to get access

Abstract

The purpose of this study was to compare our experience with duplex ultrasonography (US) and computed tomography (CT) for the routine follow-up of patients after endovascular repair (EVAR) of abdominal aortic aneurysm (AAA). We reviewed the electronic charts and radiologic exams of the first 125 patients (113 males, 12 females, median age of 76 years, range 48-98 years) with AAA treated by EVAR from June 1996 to November 2001. Our follow-up protocol included serial CT and US at regular intervals after the procedure (before discharge, at 1 month, and then every 6 months). Adequacy of each exam, ability to detect endoleaks, measurements of AAA diameter, and ability to determine graft patency were compared. For endoleak detection, comparison between CT and US was done using CT as the gold standard. A total of 608 exams, 337 CTs and 271 US, were performed 1 day to 5 years after endovascular aneurysm repair; 98% of CT and 74% of US were technically adequate. Contrary to CT, the proportion of adequate US exam was significantly less in patients with higher body mass index (BMI ≥ 30 = 54% vs. BMI < 30 = 81%, p < 0.001) and for pre-discharge US compared to the post-discharge US (54% vs. 88%, p = 0.0005). Concurrent scan pairs were obtained in 252 instances in 107 patients (1-8 pairs per patient). Excellent correlation between AAA diameter measured on CT and US was noted (correlation coefficient of 0.9, p < 0.0001). However, agreement was poor. CT anteroposterior (AP) and transverse measurements were on average 2.9 mm (95% limits of agreement = −7 to 13 mm) and 1.8 mm (95% limits of agreement = −9 to 12 mm) greater than US. For AAA diameter change, there was no case of increase AP diameter on CT. However, in 23% (29/128 pairs of sets) of US, an increase in AAA size that could have influenced patient management (≥4 mm) was reported despite no change demonstrated on CT. For endoleak detection, sensitivity and specificity of US compared to that of CT was 25% and 89%. Similar sensitivity and specificity were noted when we excluded the first set (25% and 95%), sets done prior to 2000 (30% and 89%), inadequate CT or US scans (31% and 98%), or duplicate sets of results for each patient (28% and 81%). Of the 27 endoleaks missed on US in 17 patients, 2 were type I endoleaks. None of the four endoleaks seen only on US were type I endoleak. US usefulness prior to discharge was reduced by the high rate of inadequate exam, especially in obese patients. Despite the excellent correlation in AAA diameter between US and CT, there was significant disagreement in AAA diameter measurement and diameter change. Sensitivity of nonstandardized US for endoleak was low compared to CT. CT remains our primary imaging study after EVAR, but standardization of post-EVAR US technique may improve its accuracy.
Literature
1.
go back to reference Parodi, JC, Palmaz, JC, Barone, HD 1991Transfemoral intraluminal graft implantation for abdominal aortic aneurysmsAnn. Vasc. Surg.5491499PubMed Parodi, JC, Palmaz, JC, Barone, HD 1991Transfemoral intraluminal graft implantation for abdominal aortic aneurysmsAnn. Vasc. Surg.5491499PubMed
2.
go back to reference Beebe, HG 2003Lessons learned from aortic aneurysm stent graft failure; observations from several perspectivesSemin. Vasc. Surg.16129138PubMed Beebe, HG 2003Lessons learned from aortic aneurysm stent graft failure; observations from several perspectivesSemin. Vasc. Surg.16129138PubMed
3.
go back to reference Connors, MS,III, Sternbergh, WC,III, Carter, G, Tonnessen, BH, Yoselevitz, M, Money, SR 2002Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: a cautionary noteJ. Vasc. Surg.36476484CrossRefPubMed Connors, MS,III, Sternbergh, WC,III, Carter, G, Tonnessen, BH, Yoselevitz, M, Money, SR 2002Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: a cautionary noteJ. Vasc. Surg.36476484CrossRefPubMed
4.
go back to reference Bernhard, VM, Mitchell, RS, Matsumura, JS, et al. 2002Ruptured abdominal aortic aneurysm after endovascular repairJ. Vasc. Surg.3511551162CrossRefPubMed Bernhard, VM, Mitchell, RS, Matsumura, JS,  et al. 2002Ruptured abdominal aortic aneurysm after endovascular repairJ. Vasc. Surg.3511551162CrossRefPubMed
5.
go back to reference Dattilo, JB, Brewster, DC, Fan, CM, et al. 2002Clinical failures of endovascular abdominal aortic aneurysm repair: incidence, causes, and managementJ. Vasc. Surg.3511371144CrossRefPubMed Dattilo, JB, Brewster, DC, Fan, CM,  et al. 2002Clinical failures of endovascular abdominal aortic aneurysm repair: incidence, causes, and managementJ. Vasc. Surg.3511371144CrossRefPubMed
6.
go back to reference Harris, PL, Vallabhaneni, SR, Desgranges, P, Becquemin, JP, Marrewijk, C, Laheij, RJF 2000Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experienceJ. Vasc. Surg.32739749CrossRefPubMed Harris, PL, Vallabhaneni, SR, Desgranges, P, Becquemin, JP, Marrewijk, C, Laheij, RJF 2000Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experienceJ. Vasc. Surg.32739749CrossRefPubMed
7.
go back to reference Marrewijk, C, Buth, J, Harris, PL, Norgren, L, Nevelsteen, A, Wyatt, MG 2001Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: the EUROSTAR experienceJ. Vasc. Surg.33113PubMed Marrewijk, C, Buth, J, Harris, PL, Norgren, L, Nevelsteen, A, Wyatt, MG 2001Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: the EUROSTAR experienceJ. Vasc. Surg.33113PubMed
8.
go back to reference Cao, P, Verzini, F, Zannetti, S, et al. 2002Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 yearsJ. Vasc. Surg.35229235CrossRefPubMed Cao, P, Verzini, F, Zannetti, S,  et al. 2002Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 yearsJ. Vasc. Surg.35229235CrossRefPubMed
9.
go back to reference Janne d’Othee, B, Soula, P, Otal, P, et al. 2000Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysmJ. Vasc. Surg.31190195PubMed Janne d’Othee, B, Soula, P, Otal, P,  et al. 2000Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysmJ. Vasc. Surg.31190195PubMed
10.
go back to reference Makar, R, Reid, J, Pherwani, AD, et al. 2000Aorto-enteric fistula following endovascular repair of abdominal aortic aneurysmEur. J. Vasc. Endovasc. Surg.20588590CrossRefPubMed Makar, R, Reid, J, Pherwani, AD,  et al. 2000Aorto-enteric fistula following endovascular repair of abdominal aortic aneurysmEur. J. Vasc. Endovasc. Surg.20588590CrossRefPubMed
11.
go back to reference Wolf, YG, Johnson, BL, Hill, BB, et al. 2000Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repairJ. Vasc. Surg.3211421148CrossRefPubMed Wolf, YG, Johnson, BL, Hill, BB,  et al. 2000Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repairJ. Vasc. Surg.3211421148CrossRefPubMed
12.
go back to reference D’Audiffret, A, Desgranges, P, Kobeiter, DH, Becquemin, JP 2001Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: validation with computed tomographyJ. Vasc. Surg.334250CrossRefPubMed D’Audiffret, A, Desgranges, P, Kobeiter, DH, Becquemin, JP 2001Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: validation with computed tomographyJ. Vasc. Surg.334250CrossRefPubMed
13.
go back to reference Bland, JM, Altman, DG 1999Measuring agreement in method comparison studiesStat. Methods in Med. Res.8135160CrossRef Bland, JM, Altman, DG 1999Measuring agreement in method comparison studiesStat. Methods in Med. Res.8135160CrossRef
14.
go back to reference Lederle, FA, Wilson, SE, Johnson, GR, et al. 1995Variability in measurement of abdominal aortic aneurysmsJ. Vasc. Surg.21945952PubMed Lederle, FA, Wilson, SE, Johnson, GR,  et al. 1995Variability in measurement of abdominal aortic aneurysmsJ. Vasc. Surg.21945952PubMed
15.
go back to reference Ellis, M, Powell, JT, Greenhalgh, RM 1991Limitations of ultrasonography in surveillance of small abdominal aortic aneurysmsBr. J. Surg.78614616PubMed Ellis, M, Powell, JT, Greenhalgh, RM 1991Limitations of ultrasonography in surveillance of small abdominal aortic aneurysmsBr. J. Surg.78614616PubMed
16.
go back to reference Parent, FN, Meier, GH, Godziachvili, V, et al. 2002The incidence and natural history of type I and II endoleak: a 5-year follow-up assessment with color duplex ultrasound scanJ. Vasc. Surg.35474481CrossRefPubMed Parent, FN, Meier, GH, Godziachvili, V,  et al. 2002The incidence and natural history of type I and II endoleak: a 5-year follow-up assessment with color duplex ultrasound scanJ. Vasc. Surg.35474481CrossRefPubMed
17.
go back to reference Sato, DT, Goff, CD, Gregory, RT, et al. 1998Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scanJ. Vasc. Surg.28657663PubMed Sato, DT, Goff, CD, Gregory, RT,  et al. 1998Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scanJ. Vasc. Surg.28657663PubMed
18.
go back to reference Wever, JJ, Blankensteijn, JD, Mali, WPT, Eikelboom, BC 2000Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repairEur. J. Vasc. Endovasc. Surg.20177182CrossRefPubMed Wever, JJ, Blankensteijn, JD, Mali, WPT, Eikelboom, BC 2000Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repairEur. J. Vasc. Endovasc. Surg.20177182CrossRefPubMed
19.
go back to reference Leotta, DF, Paun, M, Beach, KW, Kohler, TR, Zierler, RE, Strandness, DE,Jr 2001Measurement of abdominal aortic aneurysms with three-dimensional ultrasound imaging: preliminary reportJ. Vasc. Surg.33700707CrossRefPubMed Leotta, DF, Paun, M, Beach, KW, Kohler, TR, Zierler, RE, Strandness, DE,Jr 2001Measurement of abdominal aortic aneurysms with three-dimensional ultrasound imaging: preliminary reportJ. Vasc. Surg.33700707CrossRefPubMed
20.
go back to reference Heilberger, P, Schunn, C, Ritter, W, Weber, S, Raithel, D 1997Postoperative color flow duplex scanning in aortic endograftingJ. Endovasc. Surg.4262271PubMed Heilberger, P, Schunn, C, Ritter, W, Weber, S, Raithel, D 1997Postoperative color flow duplex scanning in aortic endograftingJ. Endovasc. Surg.4262271PubMed
21.
go back to reference McWilliams, RG, Martin, J, White, D, et al. 1999Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repairJ. Vasc. Interv. Res.1011071114 McWilliams, RG, Martin, J, White, D,  et al. 1999Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repairJ. Vasc. Interv. Res.1011071114
22.
go back to reference Bendick, PJ, Bove, PG, Long, GW, Zelenock, GB, Brown, OW, Beaumont, W (2002) Efficacy of ultrasound contrast agents in the non-invasive follow-up of aortic stent grafts. Presentation at the 30th Annual Symposium on Vascular Surgery of the Society for Clinical Vascular Surgery, March 2002 Bendick, PJ, Bove, PG, Long, GW, Zelenock, GB, Brown, OW, Beaumont, W (2002) Efficacy of ultrasound contrast agents in the non-invasive follow-up of aortic stent grafts. Presentation at the 30th Annual Symposium on Vascular Surgery of the Society for Clinical Vascular Surgery, March 2002
Metadata
Title
Computed Tomography and Ultrasound in Follow-up of Patients after Endovascular Repair of Abdominal Aortic Aneurysm
Authors
Stéphane Elkouri, MD
Jean M. Panneton, MD
James C. Andrews, MD
Bradley D. Lewis, MD
Michael A. McKusick, MD
Audra A. Noel, MD
Charles M. Rowland, MS
Thomas C. Bower, MD
Kenneth J. Cherry Jr., MD
Peter Gloviczki, MD
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 3/2004
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-004-0034-5

Other articles of this Issue 3/2004

Annals of Vascular Surgery 3/2004 Go to the issue

Commentary and Opinion

The Evidence Thing