Skip to main content
Top
Published in: Clinical Oral Investigations 2/2012

01-04-2012 | Original Article

Does a reduction of polymerization time and bonding steps affect the bond strength of brackets?

Authors: Timea Lamper, Stefanie Steinhäuser-Andresen, Karin C. Huth, Nicoleta Ilie, Ekaterini Paschos

Published in: Clinical Oral Investigations | Issue 2/2012

Login to get access

Abstract

High bond strengths are required in order to avoid bracket failure during treatment while brackets should be removable. In addition, chair time should be kept at a minimum. Therefore, the aim of this study was to investigate any differences in bracket's bond strength to enamel by reducing the polymerization time and the steps of bonding procedure. Five hundred teeth were randomly allocated into 20 groups. The groups were established considering the investigated curing units (quartz–tungsten–halogen (QTH) and light-emitting diode (LED), each with two different polymerization times) and the used bonding agents (Clearfil SE Bond, Transbond Plus, Ideal1, iBond, and Transbond XT Primer following acid etching). The brackets were debonded using a shear-peel load and used to calculate the bond strength. The location of adhesive failure was registered by using the modified adhesive remnant index (ARI). The influence of the parameters curing unit, curing time, and bonding agent as well as their interaction products on bond strength showed that the bonding agent influenced the bond strength most followed by curing time. The parameter curing unit as well as all the generated interaction products of it showed a lower impact. Regarding the ARI, the bonding agent exhibited also the highest influence. Using a LED resulted in comparable bond strengths as the QTH curing device also at shorter exposure times. Additionally, the two-component self-etching primers showed similar bond strengths compared to the acid-etching method. Chair time can be reduced by using two-component self-etching primers and LED without decrease of bond strength.
Literature
1.
go back to reference Abo T, Uno S, Sano H (2004) Comparison of bonding efficacy of an all-in-one adhesive with a self-etching primer system. Eur J Oral Sci 112(3):286–292PubMedCrossRef Abo T, Uno S, Sano H (2004) Comparison of bonding efficacy of an all-in-one adhesive with a self-etching primer system. Eur J Oral Sci 112(3):286–292PubMedCrossRef
2.
go back to reference Yamada R, Hayakawa T, Kasai K (2002) Effect of using self-etching primer for bonding orthodontic brackets. Angle Orthod 72(6):558–564PubMed Yamada R, Hayakawa T, Kasai K (2002) Effect of using self-etching primer for bonding orthodontic brackets. Angle Orthod 72(6):558–564PubMed
3.
go back to reference Krämer N, Lohbauer U, García-Godoy F, Frankenberger R (2008) Light curing of resin-based composites in the LED era. Am J Dent 21(3):135–142PubMed Krämer N, Lohbauer U, García-Godoy F, Frankenberger R (2008) Light curing of resin-based composites in the LED era. Am J Dent 21(3):135–142PubMed
4.
go back to reference Niepraschk M, Rahiotis C, Bradley TG, Eliades T, Eliades G (2007) Effect of various curing lights on the degree of cure of orthodontic adhesives. Am J Orthod Dentofacial Orthop 132(3):382–384PubMedCrossRef Niepraschk M, Rahiotis C, Bradley TG, Eliades T, Eliades G (2007) Effect of various curing lights on the degree of cure of orthodontic adhesives. Am J Orthod Dentofacial Orthop 132(3):382–384PubMedCrossRef
5.
go back to reference Wiggins KM, Hartung M, Althoff O, Wastian C, Mitra SB (2004) Curing performance of a new-generation light-emitting diode dental curing unit. J Am Dent Assoc 135(10):1471–1479PubMed Wiggins KM, Hartung M, Althoff O, Wastian C, Mitra SB (2004) Curing performance of a new-generation light-emitting diode dental curing unit. J Am Dent Assoc 135(10):1471–1479PubMed
6.
go back to reference Krishnaswamy NR, Sunitha C (2007) Light-emitting diode vs halogen light curing of orthodontic brackets: a 15-month clinical study of bond failures. Am J Orthod Dentofacial Orthop 132(4):518–523PubMedCrossRef Krishnaswamy NR, Sunitha C (2007) Light-emitting diode vs halogen light curing of orthodontic brackets: a 15-month clinical study of bond failures. Am J Orthod Dentofacial Orthop 132(4):518–523PubMedCrossRef
7.
go back to reference Mirabella D, Spena R, Scognamiglio G, Luca L, Gracco A, Siciliani G (2008) LED vs halogen light-curing of adhesive-precoated brackets. Angle Orthod 78(5):935–940PubMedCrossRef Mirabella D, Spena R, Scognamiglio G, Luca L, Gracco A, Siciliani G (2008) LED vs halogen light-curing of adhesive-precoated brackets. Angle Orthod 78(5):935–940PubMedCrossRef
8.
go back to reference Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G, Ristic M (2001) Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes. J Oral Rehabil 28(6):586–591PubMedCrossRef Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G, Ristic M (2001) Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes. J Oral Rehabil 28(6):586–591PubMedCrossRef
9.
go back to reference Usumez S, Buyukyilmaz T, Karaman AI (2004) Effect of light-emitting diode on bond strength of orthodontic brackets. Angle Orthod 74(2):259–263PubMed Usumez S, Buyukyilmaz T, Karaman AI (2004) Effect of light-emitting diode on bond strength of orthodontic brackets. Angle Orthod 74(2):259–263PubMed
10.
go back to reference Swanson T, Dunn WJ, Childers DE, Taloumis LJ (2004) Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerization times. Am J Orthod Dentofacial Orthop 125(3):337–341PubMedCrossRef Swanson T, Dunn WJ, Childers DE, Taloumis LJ (2004) Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerization times. Am J Orthod Dentofacial Orthop 125(3):337–341PubMedCrossRef
11.
go back to reference Nomoto R, Uchida K, Hirasawa T (1994) Effect of light intensity on polymerization of light-cured composite resins. Dent Mater J 13(2):198–205PubMedCrossRef Nomoto R, Uchida K, Hirasawa T (1994) Effect of light intensity on polymerization of light-cured composite resins. Dent Mater J 13(2):198–205PubMedCrossRef
12.
go back to reference Rueggeberg FA, Caughman WF, Curtis JW Jr, Davis HC (1994) A predictive model for the polymerization of photo-activated resin composites. Int J Prosthodont 7(2):159–166PubMed Rueggeberg FA, Caughman WF, Curtis JW Jr, Davis HC (1994) A predictive model for the polymerization of photo-activated resin composites. Int J Prosthodont 7(2):159–166PubMed
13.
go back to reference Paschos E, Kurochkina N, Huth KC, Hansson CS, Rudzki-Janson I (2009) Failure rate of brackets bonded with antimicrobial and fluoride-releasing, self-etching primer and the effect on prevention of enamel demineralization. Am J Orthod Dentofacial Orthop 135(5):613–620PubMedCrossRef Paschos E, Kurochkina N, Huth KC, Hansson CS, Rudzki-Janson I (2009) Failure rate of brackets bonded with antimicrobial and fluoride-releasing, self-etching primer and the effect on prevention of enamel demineralization. Am J Orthod Dentofacial Orthop 135(5):613–620PubMedCrossRef
14.
go back to reference Schaneveldt S, Foley TF (2002) Bond strength comparison of moisture-insensitive primers. Am J Orthod Dentofacial Orthop 22(3):267–273CrossRef Schaneveldt S, Foley TF (2002) Bond strength comparison of moisture-insensitive primers. Am J Orthod Dentofacial Orthop 22(3):267–273CrossRef
15.
go back to reference Hosein I, Sherriff M, Ireland AJ (2004) Enamel loss during bonding, debonding, and cleanup with use of a self-etching primer. Am J Orthod Dentofacial Orthop 126(6):717–724PubMedCrossRef Hosein I, Sherriff M, Ireland AJ (2004) Enamel loss during bonding, debonding, and cleanup with use of a self-etching primer. Am J Orthod Dentofacial Orthop 126(6):717–724PubMedCrossRef
16.
go back to reference Zeppieri IL, Chung CH, Mante FK (2003) Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers. Am J Orthod Dentofacial Orthop 124(4):414–419PubMedCrossRef Zeppieri IL, Chung CH, Mante FK (2003) Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers. Am J Orthod Dentofacial Orthop 124(4):414–419PubMedCrossRef
17.
go back to reference Bishara SE, VonWald L, Laffoon JF, Warren JJ (2001) Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 119(6):621–624PubMedCrossRef Bishara SE, VonWald L, Laffoon JF, Warren JJ (2001) Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 119(6):621–624PubMedCrossRef
18.
go back to reference Sirirungrojying S, Saito K, Hayakawa T, Kasai K (2004) Efficacy of using self-etching primer with a 4-META/MMA-TBB resin cement in bonding orthodontic brackets to human enamel and effect of saliva contamination on shear bond strength. Angle Orthod 74(2):251–258PubMed Sirirungrojying S, Saito K, Hayakawa T, Kasai K (2004) Efficacy of using self-etching primer with a 4-META/MMA-TBB resin cement in bonding orthodontic brackets to human enamel and effect of saliva contamination on shear bond strength. Angle Orthod 74(2):251–258PubMed
19.
go back to reference Cacciafesta V, Sfondrini MF, De Angelis M, Scribante A, Klersy C (2003) Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers. Am J Orthod Dentofacial Orthop 123(6):633–640PubMedCrossRef Cacciafesta V, Sfondrini MF, De Angelis M, Scribante A, Klersy C (2003) Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers. Am J Orthod Dentofacial Orthop 123(6):633–640PubMedCrossRef
20.
go back to reference Bishara SE, Oonsombat C, Ajlouni R (2004) Comparison of the shear bond strength of 2 self-etch primer/adhesive systems. Am J Orthod Dentofacial Orthop 125(3):348–350PubMedCrossRef Bishara SE, Oonsombat C, Ajlouni R (2004) Comparison of the shear bond strength of 2 self-etch primer/adhesive systems. Am J Orthod Dentofacial Orthop 125(3):348–350PubMedCrossRef
21.
go back to reference Grubisa HS, Heo G, Raboud D, Glover KE, Major PW (2004) An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. Am J Orthod Dentofacial Orthop 126(2):213–219PubMedCrossRef Grubisa HS, Heo G, Raboud D, Glover KE, Major PW (2004) An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. Am J Orthod Dentofacial Orthop 126(2):213–219PubMedCrossRef
22.
go back to reference Oesterle LJ, Shellhart WC, Belanger GK (1998) The use of bovine enamel in bonding studies. Am J Orthod Dentofacial Orthop 114(5):514–519PubMedCrossRef Oesterle LJ, Shellhart WC, Belanger GK (1998) The use of bovine enamel in bonding studies. Am J Orthod Dentofacial Orthop 114(5):514–519PubMedCrossRef
23.
go back to reference Eliades T, Brantley WA (2000) The inappropriateness of conventional orthodontic bond strength assessment protocols. Eur J Orthod 22(1):13–23PubMedCrossRef Eliades T, Brantley WA (2000) The inappropriateness of conventional orthodontic bond strength assessment protocols. Eur J Orthod 22(1):13–23PubMedCrossRef
24.
go back to reference Ajlouni R, Bishara SE, Oonsombat C, Denehy GE (2004) Evaluation of modifying the bonding protocol of a new acid-etch primer on the shear bond strength of orthodontic brackets. Angle Orthod 74(3):410–413PubMed Ajlouni R, Bishara SE, Oonsombat C, Denehy GE (2004) Evaluation of modifying the bonding protocol of a new acid-etch primer on the shear bond strength of orthodontic brackets. Angle Orthod 74(3):410–413PubMed
25.
go back to reference Vicente A, Bravo LA, Romero M, Ortíz AJ, Canteras M (2005) Shear bond strength of orthodontic brackets bonded with self-etching primers. Am J Dent 18(4):256–260PubMed Vicente A, Bravo LA, Romero M, Ortíz AJ, Canteras M (2005) Shear bond strength of orthodontic brackets bonded with self-etching primers. Am J Dent 18(4):256–260PubMed
26.
go back to reference Bishara SE, Ajlouni R, Laffoon JF (2003) Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive. Am J Orthod Dentofacial Orthop 123(1):21–24PubMedCrossRef Bishara SE, Ajlouni R, Laffoon JF (2003) Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive. Am J Orthod Dentofacial Orthop 123(1):21–24PubMedCrossRef
27.
go back to reference Zachrisson BJ (1977) A posttreatment evaluation of direct bonding in orthodontics. Am J Orthod 71(2):173–189PubMedCrossRef Zachrisson BJ (1977) A posttreatment evaluation of direct bonding in orthodontics. Am J Orthod 71(2):173–189PubMedCrossRef
28.
go back to reference Fox NA, McCabe JF, Buckley JG (1994) A critique of bond strength testing in orthodontics. Br J Orthod 21(1):33–43PubMed Fox NA, McCabe JF, Buckley JG (1994) A critique of bond strength testing in orthodontics. Br J Orthod 21(1):33–43PubMed
29.
go back to reference Klocke A, Kahl-Nieke B (2005) Influence of cross-head speed in orthodontic bond strength testing. Dent Mater 21(2):139–144PubMedCrossRef Klocke A, Kahl-Nieke B (2005) Influence of cross-head speed in orthodontic bond strength testing. Dent Mater 21(2):139–144PubMedCrossRef
30.
go back to reference Klocke A, Kahl-Nieke B (2005) Influence of force location in orthodontic shear bond strength testing. Dent Mater 21(5):391–396PubMedCrossRef Klocke A, Kahl-Nieke B (2005) Influence of force location in orthodontic shear bond strength testing. Dent Mater 21(5):391–396PubMedCrossRef
31.
go back to reference Paschos E, Westphal JO, Ilie N, Huth KC, Hickel R, Rudzki-Janson I (2008) Artificial saliva contamination effects on bond strength of self-etching primers. Angle Orthod 78(4):716–721PubMedCrossRef Paschos E, Westphal JO, Ilie N, Huth KC, Hickel R, Rudzki-Janson I (2008) Artificial saliva contamination effects on bond strength of self-etching primers. Angle Orthod 78(4):716–721PubMedCrossRef
32.
go back to reference Paschos E, Okuka S, Ilie N, Huth KC, Hickel R, Rudzki-Janson I (2006) Investigation of shear-peel bond strength of orthodontic brackets on enamel after using Pro Seal. J Orofac Orthop 67(3):196–206PubMedCrossRef Paschos E, Okuka S, Ilie N, Huth KC, Hickel R, Rudzki-Janson I (2006) Investigation of shear-peel bond strength of orthodontic brackets on enamel after using Pro Seal. J Orofac Orthop 67(3):196–206PubMedCrossRef
33.
go back to reference Trites B, Foley TF, Banting D (2004) Bond strength comparison of 2 self-etching primers over a 3-month storage period. Am J Orthod Dentofacial Orthop 126(6):709–716PubMedCrossRef Trites B, Foley TF, Banting D (2004) Bond strength comparison of 2 self-etching primers over a 3-month storage period. Am J Orthod Dentofacial Orthop 126(6):709–716PubMedCrossRef
34.
go back to reference Minick GT, Oesterle LJ, Newman SM, Shellhart WC (2009) Bracket bond strengths of new adhesive systems. Am J Orthod Dentofacial Orthop 135(6):771–776PubMedCrossRef Minick GT, Oesterle LJ, Newman SM, Shellhart WC (2009) Bracket bond strengths of new adhesive systems. Am J Orthod Dentofacial Orthop 135(6):771–776PubMedCrossRef
35.
go back to reference House K, Ireland AJ, Sherriff M (2006) An in-vitro investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a pilot study. J Orthod 33(2):116–124PubMedCrossRef House K, Ireland AJ, Sherriff M (2006) An in-vitro investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a pilot study. J Orthod 33(2):116–124PubMedCrossRef
36.
go back to reference House K, Ireland AJ, Sherriff M (2006) An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a randomized controlled clinical trial. J Orthod 33(1):38–44PubMedCrossRef House K, Ireland AJ, Sherriff M (2006) An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a randomized controlled clinical trial. J Orthod 33(1):38–44PubMedCrossRef
37.
go back to reference Marquezan M, Lau T, Rodrigues C, Sant'Anna E, Ruellas A, Marquezan M, Elias C (2010) Shear bond strengths of orthodontic brackets with a new LED cluster curing light. J Orthod 37(1):37–42PubMedCrossRef Marquezan M, Lau T, Rodrigues C, Sant'Anna E, Ruellas A, Marquezan M, Elias C (2010) Shear bond strengths of orthodontic brackets with a new LED cluster curing light. J Orthod 37(1):37–42PubMedCrossRef
38.
go back to reference Penido SM, Penido CV, dos Santos-Pinto A, Gandini LG Jr, Bagnato VS (2009) In vivo and in vitro study of the shear bond strength of brackets bonded to enamel using halogen or LED light. World J Orthod 10(1):21–28PubMed Penido SM, Penido CV, dos Santos-Pinto A, Gandini LG Jr, Bagnato VS (2009) In vivo and in vitro study of the shear bond strength of brackets bonded to enamel using halogen or LED light. World J Orthod 10(1):21–28PubMed
39.
go back to reference Redd TB, Shivapuja PK (1991) Debonding ceramic brackets: effects on enamel. J Clin Orthod 25(8):475–481PubMed Redd TB, Shivapuja PK (1991) Debonding ceramic brackets: effects on enamel. J Clin Orthod 25(8):475–481PubMed
40.
go back to reference Diedrich P (1981) Enamel alterations from bracket bonding and debonding: a study with the scanning electron microscope. Am J Orthod 79(5):500–522PubMedCrossRef Diedrich P (1981) Enamel alterations from bracket bonding and debonding: a study with the scanning electron microscope. Am J Orthod 79(5):500–522PubMedCrossRef
Metadata
Title
Does a reduction of polymerization time and bonding steps affect the bond strength of brackets?
Authors
Timea Lamper
Stefanie Steinhäuser-Andresen
Karin C. Huth
Nicoleta Ilie
Ekaterini Paschos
Publication date
01-04-2012
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 2/2012
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-011-0540-0

Other articles of this Issue 2/2012

Clinical Oral Investigations 2/2012 Go to the issue