Skip to main content
Top
Published in: Journal of Orthopaedic Science 3/2013

01-05-2013 | Original Article

Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases

Authors: Simon M. Graham, Mehran Moazen, Andreas Leonidou, Eleftherios Tsiridis

Published in: Journal of Orthopaedic Science | Issue 3/2013

Login to get access

Abstract

Purpose

The overall incidence of periprosthetic femoral fractures (PPF) is between 0.1 and 6 % of all total hip arthroplasties. Locking compression plates (LCP) have been used for the treatment of Vancouver B1 PPFs with variable results. The aim of this study is to examine the literature on locking plate failure rates, mode and reasons for failure.

Methodology

A literature search was conducted for studies reporting the management of PPF of the femur with LCP fixation. The primary medical search engines used for the study were Ovid MEDLINE and EMBASE databases up to August 2012.

Results

Twelve studies were identified, reporting overall union rates of 91 % in 135 fractures. Only 7 (5 %) fractures required revision surgery due to plate fracture (5) or pull out (2). Important trends in plate complications included: stress riser at the end of the plate, stress concentration in the fracture area due to rigid fixation, early loading and absence of cortical strut grafting for biological support when needed.

Conclusion

LCP has been used successfully in the management of Vancouver B1 PPF. However, potential areas of improvement include, leaving the fracture site free of locking screws, therefore, not disturbing the soft tissue envelope around the fracture and also reducing plate stiffness. Adding cortical strut allografts to improve stability and bone quality, if needed, may also improve outcome. Limitations in the use of strut grafts or transverse fractures below the tip of the stem that cannot be controlled with single or double plating may require long stem revision to achieve axial stability.
Literature
1.
go back to reference Tsiridis E, Pavlou G, Venkatesh R, Bobak P, Gie G. Periprosthetic femoral fractures around hip arthroplasty: current concepts in their management. Hip Int. 2009;19(2):75–86. Tsiridis E, Pavlou G, Venkatesh R, Bobak P, Gie G. Periprosthetic femoral fractures around hip arthroplasty: current concepts in their management. Hip Int. 2009;19(2):75–86.
4.
go back to reference Duncan CP, Masri BA. Fractures of the femur after hip replacement. Instr Course Lect. 1995;44:293–304.PubMed Duncan CP, Masri BA. Fractures of the femur after hip replacement. Instr Course Lect. 1995;44:293–304.PubMed
5.
go back to reference Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63–76.PubMedCrossRef Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63–76.PubMedCrossRef
6.
go back to reference Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94.PubMedCrossRef Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94.PubMedCrossRef
7.
go back to reference Moazen M, Jones AC, Jin Z, Wilcox RK, Tsiridis E. Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing. Clin Biomech (Bristol, Avon). 2011;26(1):13–22. Moazen M, Jones AC, Jin Z, Wilcox RK, Tsiridis E. Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing. Clin Biomech (Bristol, Avon). 2011;26(1):13–22.
8.
go back to reference Khalid M, Theivendran K, Cheema M, Rajaratnam V, Deshmukh SC. Biomechanical comparison of pull-out force of unicortical versus bicortical screws in proximal phalanges of the hand: a human cadaveric study. Clin Biomech (Bristol, Avon). 2008;23(9):1136–40. Khalid M, Theivendran K, Cheema M, Rajaratnam V, Deshmukh SC. Biomechanical comparison of pull-out force of unicortical versus bicortical screws in proximal phalanges of the hand: a human cadaveric study. Clin Biomech (Bristol, Avon). 2008;23(9):1136–40.
9.
go back to reference Chakravarthy J, Bansal R, Cooper J. Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury. 2007;38(6):725–33.PubMedCrossRef Chakravarthy J, Bansal R, Cooper J. Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury. 2007;38(6):725–33.PubMedCrossRef
10.
go back to reference Anakwe RE, Aitken SA, Khan LA. Osteoporotic periprosthetic fractures of the femur in elderly patients: outcome after fixation with the LISS plate. Injury. 2008;39(10):1191–7.PubMedCrossRef Anakwe RE, Aitken SA, Khan LA. Osteoporotic periprosthetic fractures of the femur in elderly patients: outcome after fixation with the LISS plate. Injury. 2008;39(10):1191–7.PubMedCrossRef
11.
go back to reference Bryant GK, Morshed S, Agel J, Henley MB, Barei DP, Taitsman LA. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury. 2009;40(11):1180–6.PubMedCrossRef Bryant GK, Morshed S, Agel J, Henley MB, Barei DP, Taitsman LA. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury. 2009;40(11):1180–6.PubMedCrossRef
12.
go back to reference Buttaro MA, Farfalli G, Paredes Núñez M, Comba F, Piccaluga F. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am. 2007;89(9):1964–9.PubMedCrossRef Buttaro MA, Farfalli G, Paredes Núñez M, Comba F, Piccaluga F. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am. 2007;89(9):1964–9.PubMedCrossRef
13.
go back to reference Ebraheim NA, Gomez C, Ramineni SK, Liu J. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma. 2009;66(4):1152–7.PubMedCrossRef Ebraheim NA, Gomez C, Ramineni SK, Liu J. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma. 2009;66(4):1152–7.PubMedCrossRef
14.
go back to reference Kaab MJ, Stöckle U, Schütz M, Stefansky J, Perka C, Haas NP. Stabilisation of periprosthetic fractures with angular stable internal fixation: a report of 13 cases. Arch Orthop Trauma Surg. 2006;126(2):105–10.PubMedCrossRef Kaab MJ, Stöckle U, Schütz M, Stefansky J, Perka C, Haas NP. Stabilisation of periprosthetic fractures with angular stable internal fixation: a report of 13 cases. Arch Orthop Trauma Surg. 2006;126(2):105–10.PubMedCrossRef
15.
go back to reference Kobbe P, Klemm R, Reilmann H, Hockertz TJ. Less invasive stabilisation system (LISS) for the treatment of periprosthetic femoral fractures: a 3-year follow-up. Injury. 2008;39(4):472–9.PubMedCrossRef Kobbe P, Klemm R, Reilmann H, Hockertz TJ. Less invasive stabilisation system (LISS) for the treatment of periprosthetic femoral fractures: a 3-year follow-up. Injury. 2008;39(4):472–9.PubMedCrossRef
16.
go back to reference Kumar V, Kanabar P, Owen PJ, Rushton N. Less invasive stabilization system for the management of periprosthetic femoral fractures around hip arthroplasty. J Arthroplast. 2008;23(3):446–50.CrossRef Kumar V, Kanabar P, Owen PJ, Rushton N. Less invasive stabilization system for the management of periprosthetic femoral fractures around hip arthroplasty. J Arthroplast. 2008;23(3):446–50.CrossRef
17.
go back to reference O’Toole RV, Kanabar P, Owen PJ, Rushton N. Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res. 2006;450:203–10.PubMedCrossRef O’Toole RV, Kanabar P, Owen PJ, Rushton N. Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res. 2006;450:203–10.PubMedCrossRef
18.
go back to reference Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J Jr. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. Surg Technique. J Bone Joint Surg Am. 2006;88 Suppl 1 Pt 2:275–82. Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J Jr. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. Surg Technique. J Bone Joint Surg Am. 2006;88 Suppl 1 Pt 2:275–82.
19.
go back to reference Schutz M, Krettek C, Höntzsch D, Regazzoni P, Ganz R, Haas N. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Results of a clinical study with special emphasis on difficult cases. Injury. 2001;32 Suppl 3:SC48–54. Schutz M, Krettek C, Höntzsch D, Regazzoni P, Ganz R, Haas N. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Results of a clinical study with special emphasis on difficult cases. Injury. 2001;32 Suppl 3:SC48–54.
20.
go back to reference Wood GC, Naudie DR, McAuley J, McCalden RW. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplast. 2011;26(6):886–92. doi:10.1016/j.arth.2010.07.002. Wood GC, Naudie DR, McAuley J, McCalden RW. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplast. 2011;26(6):886–92. doi:10.​1016/​j.​arth.​2010.​07.​002.
21.
go back to reference Xue H, Tu Y, Cai M, Yang A. Locking compression plate and cerclage band for type b1 periprosthetic femoral fractures preliminary results at average 30-month follow-up. J Arthroplast. 2011;26(3):467–71.e1. doi:10.1016/j.arth.2010.03.031. Xue H, Tu Y, Cai M, Yang A. Locking compression plate and cerclage band for type b1 periprosthetic femoral fractures preliminary results at average 30-month follow-up. J Arthroplast. 2011;26(3):467–71.e1. doi:10.​1016/​j.​arth.​2010.​03.​031.
22.
go back to reference Pavlou G, Panteliadis P, Macdonald D, Timperley JA, Gie G, Bancroft G, Tsiridis E. A review of 202 periprosthetic fractures—stem revision and allograft improves outcome for type B fractures. Hip Int. 2011;21(1):21–9.PubMedCrossRef Pavlou G, Panteliadis P, Macdonald D, Timperley JA, Gie G, Bancroft G, Tsiridis E. A review of 202 periprosthetic fractures—stem revision and allograft improves outcome for type B fractures. Hip Int. 2011;21(1):21–9.PubMedCrossRef
23.
go back to reference Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156–62.PubMedCrossRef Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156–62.PubMedCrossRef
24.
go back to reference Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093–110.PubMedCrossRef Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093–110.PubMedCrossRef
25.
go back to reference Stoffel K, Dieter U, Stachowiak G, Gächter A, Kuster MS. Biomechanical testing of the LCP—how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11–9.PubMedCrossRef Stoffel K, Dieter U, Stachowiak G, Gächter A, Kuster MS. Biomechanical testing of the LCP—how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11–9.PubMedCrossRef
26.
go back to reference Ahmad M, Nanda R, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury. 2007;38(3):358–64.PubMedCrossRef Ahmad M, Nanda R, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury. 2007;38(3):358–64.PubMedCrossRef
27.
go back to reference Bellapianta J, Dow K, Pallotta NA, Hospodar PP, Uhl RL, Ledet EH. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma. 2011;25(2):65–71.PubMedCrossRef Bellapianta J, Dow K, Pallotta NA, Hospodar PP, Uhl RL, Ledet EH. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma. 2011;25(2):65–71.PubMedCrossRef
28.
go back to reference Uhthoff HK, Poitras P, Backman DS. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci. 2006;11(2):118–26.PubMedCrossRef Uhthoff HK, Poitras P, Backman DS. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci. 2006;11(2):118–26.PubMedCrossRef
29.
go back to reference Haddad FS, Garbuz DS, Masri BA. Duncan CP. Structural proximal femoral allografts for failed total hip replacements: a minimum review of five years. J Bone Joint Surg Br. 2000;82(6):830–6.PubMedCrossRef Haddad FS, Garbuz DS, Masri BA. Duncan CP. Structural proximal femoral allografts for failed total hip replacements: a minimum review of five years. J Bone Joint Surg Br. 2000;82(6):830–6.PubMedCrossRef
30.
go back to reference Noordeen MH, Lavy CB, Shergill NS, Tuite JD, Jackson AM. Cyclical micromovement and fracture healing. J Bone Joint Surg Br. 1995;77(4):645–8. Noordeen MH, Lavy CB, Shergill NS, Tuite JD, Jackson AM. Cyclical micromovement and fracture healing. J Bone Joint Surg Br. 1995;77(4):645–8.
Metadata
Title
Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases
Authors
Simon M. Graham
Mehran Moazen
Andreas Leonidou
Eleftherios Tsiridis
Publication date
01-05-2013
Publisher
Springer Japan
Published in
Journal of Orthopaedic Science / Issue 3/2013
Print ISSN: 0949-2658
Electronic ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-013-0359-4

Other articles of this Issue 3/2013

Journal of Orthopaedic Science 3/2013 Go to the issue