Abstract

Metal plates for internal fixation of fractures have been used for more than 100 years. Although initial shortcomings such as corrosion and insufficient strength have been overcome, more recent designs have not solved all problems. Further research is needed to develop a plate that accelerates fracture healing while not interfering with bone physiology.
The introduction of rigid plates had by far the greatest impact on plate fixation of fractures. However, it led to cortical porosis, delayed bridging, and refractures after plate removal. These unwarranted effects were said to be caused by bone–plate contact interfering with cortical perfusion. Consequently, further plate modifications aimed to reduce this contact area to minimize necrosis and subsequent porosis.
The advocates of limited-contact plates have not published measurements of the contact area or proof of the temporary nature of the porosis. Moreover, clinical studies of newer plate types have failed to show a superior outcome. Histomor-phometric measurements of the cortex showed no difference in the extent of necrosis under plates having different contact areas. Necrosis was predominant in the periosteal cortical half, whereas porosis occurred mostly in the endosteal cortical half. No positive correlation was found between either.
The scientific evidence to date strongly suggests that bone loss is caused by stress shielding and not interference with cortical perfusion secondary to bone–plate contact. Consequently, an axially compressible plate (ACP) incorporating polylactide (PLA) inserts press-fit around screw holes was designed. The bioresorbable inserts should allow for (1) increased micromotion in the axial plane to promote healing during the union phase and (2) gradual degradation over time to decrease stress shielding during the remodeling phase.
Results of ongoing experimental results are encouraging. Only plates allowing dynamic compression in the axial plane can lead to a revolution in fracture fixation.
Literature
2.
go back to reference Lambotte, A 1909Technique et indication des prothèses dans le traitement des fracturesPresse Med17321 Lambotte, A 1909Technique et indication des prothèses dans le traitement des fracturesPresse Med17321
3.
go back to reference Sherman, WO 1912Vanadium steel bone plates and screwsSurg Gynecol Obstet1462934 Sherman, WO 1912Vanadium steel bone plates and screwsSurg Gynecol Obstet1462934
4.
go back to reference Eggers, GWN 1948Internal contact splintJ Bone Joint Surg Am304052 Eggers, GWN 1948Internal contact splintJ Bone Joint Surg Am304052
5.
go back to reference Danis, R 1949Théorie et pratique de l’ostéosynthèseMassonParis Danis, R 1949Théorie et pratique de l’ostéosynthèseMassonParis
6.
go back to reference Bagby, GW, Janes, JM 1958The effect of compression on the rate of fracture healing using a special plateAm J Surg9576171CrossRefPubMed Bagby, GW, Janes, JM 1958The effect of compression on the rate of fracture healing using a special plateAm J Surg9576171CrossRefPubMed
7.
go back to reference Müller, ME, Allgöwer, M, Willenegger, H 1965Compression fixation with platesTechnique of internal fixation of fracturesSpringerBerlin4751 Müller, ME, Allgöwer, M, Willenegger, H 1965Compression fixation with platesTechnique of internal fixation of fracturesSpringerBerlin4751
8.
go back to reference Perren, SM, Cordey, J, Rahn, BA, Gautier, E, Schneider, E 1988Early temporary porosis of bone induced by internal fixation implants: a reaction to necrosis, not to stress protection?Clin Orthop23213951PubMed Perren, SM, Cordey, J, Rahn, BA, Gautier, E, Schneider, E 1988Early temporary porosis of bone induced by internal fixation implants: a reaction to necrosis, not to stress protection?Clin Orthop23213951PubMed
9.
go back to reference Perren, SM, Russenberger, M, Steinemann, S, Müller, ME, Allgöwer, M 1969A dynamic compression plateActa Orthop ScandSuppl 1253141 Perren, SM, Russenberger, M, Steinemann, S, Müller, ME, Allgöwer, M 1969A dynamic compression plateActa Orthop ScandSuppl 1253141
10.
go back to reference Schenk, R, Willenegger, H 1967Morphological findings in primary fracture healingKrompecher, SKerner, E eds. Callus formation symposium on the biology of fracture healingAkadémiai KiadóBudapest7586 Schenk, R, Willenegger, H 1967Morphological findings in primary fracture healingKrompecher, SKerner, E eds. Callus formation symposium on the biology of fracture healingAkadémiai KiadóBudapest7586
11.
go back to reference Kessler, SB, Deiler, S, Schiffl-Deiler, M, Uhthoff, HK, Schweiberer, L 1992Refractures: a consequence of impaired local bone viabilityArch Orthop Trauma Surg11196101CrossRefPubMed Kessler, SB, Deiler, S, Schiffl-Deiler, M, Uhthoff, HK, Schweiberer, L 1992Refractures: a consequence of impaired local bone viabilityArch Orthop Trauma Surg11196101CrossRefPubMed
12.
go back to reference Berkin, CR, Marshall, DV 1972Three-sided plate fixation for fractures of the tibial and femoral shafts: a follow-up noteJ Bone Joint Surg Am54110513PubMed Berkin, CR, Marshall, DV 1972Three-sided plate fixation for fractures of the tibial and femoral shafts: a follow-up noteJ Bone Joint Surg Am54110513PubMed
13.
go back to reference Gautier, E, Perren, SM 1992Die limited contact dynamic compression plate (LC-DCP): Biomechanische Forschung als Grundlage des neuen PlattendesignsOrthopade211123(in German)PubMed Gautier, E, Perren, SM 1992Die limited contact dynamic compression plate (LC-DCP): Biomechanische Forschung als Grundlage des neuen PlattendesignsOrthopade211123(in German)PubMed
14.
go back to reference Tepic, S, Perren, SM 1995The biomechanics of the PC-Fix internal fixatorInjury26S-B510 Tepic, S, Perren, SM 1995The biomechanics of the PC-Fix internal fixatorInjury26S-B510
15.
go back to reference Field, JR, Hearn, TC, Caldwell, CB 1997Bone plate fixation: an evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact-dynamic compression plate (LC-DCP) applied to cadaveric boneJ Orthop Trauma1136873CrossRefPubMed Field, JR, Hearn, TC, Caldwell, CB 1997Bone plate fixation: an evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact-dynamic compression plate (LC-DCP) applied to cadaveric boneJ Orthop Trauma1136873CrossRefPubMed
16.
go back to reference Jain, R, Podworny, N, Hupel, TM, Weinberg, J, Schemitsch, EH 1999Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fracturesJ Orthop Trauma1317886CrossRefPubMed Jain, R, Podworny, N, Hupel, TM, Weinberg, J, Schemitsch, EH 1999Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fracturesJ Orthop Trauma1317886CrossRefPubMed
17.
go back to reference Akeson, WH, Woo, SLY, Rutherford, L, Coutts, RD, Gonsalves, M, Amiel, D 1976The effects of rigidity of internal fixation plates on long bone remodelingActa Orthop Scand472419PubMed Akeson, WH, Woo, SLY, Rutherford, L, Coutts, RD, Gonsalves, M, Amiel, D 1976The effects of rigidity of internal fixation plates on long bone remodelingActa Orthop Scand472419PubMed
18.
go back to reference Slätis, P, Paavolainen, P, Karaharju, E, Holström, T 1980Structural and biomechanical changes in bone after rigid plate fixationUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin291 Slätis, P, Paavolainen, P, Karaharju, E, Holström, T 1980Structural and biomechanical changes in bone after rigid plate fixationUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin291
19.
go back to reference Strömberg, L, Dalén, N, Låftman, P, Sigurdsson, F 1980Atrophy of cortical bone caused by rigid plates and its recoveryUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin28990 Strömberg, L, Dalén, N, Låftman, P, Sigurdsson, F 1980Atrophy of cortical bone caused by rigid plates and its recoveryUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin28990
20.
go back to reference Uhthoff, HK, Bardos, DI, Liskova-Kiar, M 1981The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures: an experimental study in dogsJ Bone Joint Surg Br6342734PubMed Uhthoff, HK, Bardos, DI, Liskova-Kiar, M 1981The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures: an experimental study in dogsJ Bone Joint Surg Br6342734PubMed
21.
go back to reference Uhthoff, HK, Dubuc, FL 1971Bone structure changes in the dog under rigid internal fixationClin Orthop8116570CrossRefPubMed Uhthoff, HK, Dubuc, FL 1971Bone structure changes in the dog under rigid internal fixationClin Orthop8116570CrossRefPubMed
22.
go back to reference Uhthoff, HK, Finnegan, M 1983The effects of metal plates on post-traumatic remodelling and bone massJ Bone Joint Surg Br656671PubMed Uhthoff, HK, Finnegan, M 1983The effects of metal plates on post-traumatic remodelling and bone massJ Bone Joint Surg Br656671PubMed
23.
go back to reference Gunst, MA, Suter, C, Rahn, BA 1979Bone perfusion after plate osteosynthesis: a study of the intact rabbit tibia with disulfin blue vital stainingHelv Chir Acta461715(in German)PubMed Gunst, MA, Suter, C, Rahn, BA 1979Bone perfusion after plate osteosynthesis: a study of the intact rabbit tibia with disulfin blue vital stainingHelv Chir Acta461715(in German)PubMed
24.
go back to reference Uhthoff, HK, Boisvert, D, Finnegan, M 1994Cortical porosis under plates: reaction to unloading or to necrosis?J Bone Joint Surg Am76150712PubMed Uhthoff, HK, Boisvert, D, Finnegan, M 1994Cortical porosis under plates: reaction to unloading or to necrosis?J Bone Joint Surg Am76150712PubMed
25.
go back to reference Jaworski, ZFG, Liskova-Kiar, M, Uhthoff, HK 1980Regional disuse osteoporosis and factors influencing its reversalUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin1726 Jaworski, ZFG, Liskova-Kiar, M, Uhthoff, HK 1980Regional disuse osteoporosis and factors influencing its reversalUhthoff, HK eds. Current concepts of internal fixation of fracturesSpringerBerlin1726
26.
go back to reference Uhthoff, HK, Jaworski, ZFG 1978Bone loss in response to long-term immobilizationJ Bone Joint Surg Br604209PubMed Uhthoff, HK, Jaworski, ZFG 1978Bone loss in response to long-term immobilizationJ Bone Joint Surg Br604209PubMed
27.
go back to reference Korvick, DL, Newbrey, JW, Bagby, GW, Pettit, GD, Lincoln, JD 1989Stress shielding reduced by a silicon plate-bone interfaceActa Orthop Scand6061116PubMed Korvick, DL, Newbrey, JW, Bagby, GW, Pettit, GD, Lincoln, JD 1989Stress shielding reduced by a silicon plate-bone interfaceActa Orthop Scand6061116PubMed
28.
go back to reference Perren, SM 2002Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation; choosing a new balance between stability and biologyJ Bone Joint Surg Br841093110CrossRefPubMed Perren, SM 2002Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation; choosing a new balance between stability and biologyJ Bone Joint Surg Br841093110CrossRefPubMed
29.
go back to reference Andersen, LD, Sisk, D, Tooms, RE, Park, WI,III 1975Compression-plate fixation in acute diaphyseal fractures of the radius and ulnaJ Bone Joint Surg Am5728797 Andersen, LD, Sisk, D, Tooms, RE, Park, WI,III 1975Compression-plate fixation in acute diaphyseal fractures of the radius and ulnaJ Bone Joint Surg Am5728797
30.
go back to reference Chapman, MW, Gordon, JE, Zissimos, AG 1989Compression-plate fixation of acute fractures of the diaphyses of the radius and ulnaJ Bone Joint Surg Am7115969PubMed Chapman, MW, Gordon, JE, Zissimos, AG 1989Compression-plate fixation of acute fractures of the diaphyses of the radius and ulnaJ Bone Joint Surg Am7115969PubMed
31.
go back to reference Hertel, R, Pisan, M, Lambert, S, Ballmer, FT 1996Plate osteosynthesis of diaphyseal fractures of the radius and ulnaInjury275458CrossRefPubMed Hertel, R, Pisan, M, Lambert, S, Ballmer, FT 1996Plate osteosynthesis of diaphyseal fractures of the radius and ulnaInjury275458CrossRefPubMed
32.
go back to reference McKee, MD, Seiler, JG, Jupiter, JB 1995The application of the limited contact dynamic compression plate in the upper extremity: an analysis of 114 consecutive casesInjury266616CrossRefPubMed McKee, MD, Seiler, JG, Jupiter, JB 1995The application of the limited contact dynamic compression plate in the upper extremity: an analysis of 114 consecutive casesInjury266616CrossRefPubMed
33.
go back to reference Gupta, R, Raheja, A, Sharma, V 2000Limited contact dynamic compression in diaphyseal fractures of the humerus: good outcome in 51 patientsActa Orthop Scand714714PubMedCrossRef Gupta, R, Raheja, A, Sharma, V 2000Limited contact dynamic compression in diaphyseal fractures of the humerus: good outcome in 51 patientsActa Orthop Scand714714PubMedCrossRef
34.
go back to reference Gerber, C, Mast, JW, Ganz, R 1990Biological internal fixation of fracturesArch Orthop Trauma Surg109295303CrossRefPubMed Gerber, C, Mast, JW, Ganz, R 1990Biological internal fixation of fracturesArch Orthop Trauma Surg109295303CrossRefPubMed
35.
go back to reference Van Frank Haasnoot, E, Münch, TWH, Matter, P, Perren, SM 1995Radiological sequences of healing in internal plates and splints of different contact surface to bone (DCP, LC-DCP and PC-Fix)Injury26S-B2836 Van Frank Haasnoot, E, Münch, TWH, Matter, P, Perren, SM 1995Radiological sequences of healing in internal plates and splints of different contact surface to bone (DCP, LC-DCP and PC-Fix)Injury26S-B2836
36.
go back to reference Haas, N, Hauke, C, Schütz, M, Kääb, M, Perren, SM 2001Treatment of diaphyseal fractures of the forearm using the point contact fixator (PC-Fix): results of 387 fractures of a prospective multicentric study (PC-Fix II)Injury32S-B-5162CrossRef Haas, N, Hauke, C, Schütz, M, Kääb, M, Perren, SM 2001Treatment of diaphyseal fractures of the forearm using the point contact fixator (PC-Fix): results of 387 fractures of a prospective multicentric study (PC-Fix II)Injury32S-B-5162CrossRef
37.
go back to reference Hertel, R, Eijer, H, Meisser, A, Hauke, C, Perren, SM 2001Biomechanical and biological considerations relating to the clinical use of the point contact-fixator: evaluation of the device handling test in the treatment of diaphyseal fractures of the radius and/or ulnaInjury32S-B-1014CrossRef Hertel, R, Eijer, H, Meisser, A, Hauke, C, Perren, SM 2001Biomechanical and biological considerations relating to the clinical use of the point contact-fixator: evaluation of the device handling test in the treatment of diaphyseal fractures of the radius and/or ulnaInjury32S-B-1014CrossRef
38.
go back to reference Fernandez Dell’Oca, AA, Masliah Galante, R 2001Osteosynthesis of diaphyseal fractures of the radius and ulna using an internal fixator (PC-Fix): a prospective studyInjury32S-B-4450 Fernandez Dell’Oca, AA, Masliah Galante, R 2001Osteosynthesis of diaphyseal fractures of the radius and ulna using an internal fixator (PC-Fix): a prospective studyInjury32S-B-4450
39.
go back to reference Perren, SM, Buchanan, JS 1995Basic concepts relevant to the design and development of the point contact fixator (PC-Fix)Injury26S-B-14 Perren, SM, Buchanan, JS 1995Basic concepts relevant to the design and development of the point contact fixator (PC-Fix)Injury26S-B-14
40.
go back to reference Leung, F, Chow, SP 2003A prospective, randomized trial comparing the limited contact dynamic compression plate with the point contact fixator for forearm fracturesJ Bone Joint Surg Am8523438PubMed Leung, F, Chow, SP 2003A prospective, randomized trial comparing the limited contact dynamic compression plate with the point contact fixator for forearm fracturesJ Bone Joint Surg Am8523438PubMed
41.
go back to reference Schütz, M, Südkamp, NP 2003Revolution in plate osteosynthesis: new internal fixator systemsJ Orthop Sci82528CrossRefPubMed Schütz, M, Südkamp, NP 2003Revolution in plate osteosynthesis: new internal fixator systemsJ Orthop Sci82528CrossRefPubMed
42.
go back to reference Ilizarov, GA 1990Clinical application of the tension-stress effect for limb lengtheningClin Orthop250826PubMed Ilizarov, GA 1990Clinical application of the tension-stress effect for limb lengtheningClin Orthop250826PubMed
43.
go back to reference Goodship, AE, Kenwright, J 1985The influence of induced micromovement upon the healing of experimental tibial fracturesJ Bone Joint Surg Br676505PubMed Goodship, AE, Kenwright, J 1985The influence of induced micromovement upon the healing of experimental tibial fracturesJ Bone Joint Surg Br676505PubMed
44.
go back to reference Foux, A, Yeadon, AJ, Uhthoff, HK 1997Improved fracture healing with less rigid plates: a biomechanical study in dogsClin Orthop33923245CrossRefPubMed Foux, A, Yeadon, AJ, Uhthoff, HK 1997Improved fracture healing with less rigid plates: a biomechanical study in dogsClin Orthop33923245CrossRefPubMed
45.
go back to reference Backman, D, Uhthoff, H, Poitras, P, Schwamberger, A 2004Mechanical performance of a fracture plate incorporating bioresorbable insertsJ Bone Joint Surg Proceed Br86300 Backman, D, Uhthoff, H, Poitras, P, Schwamberger, A 2004Mechanical performance of a fracture plate incorporating bioresorbable insertsJ Bone Joint Surg Proceed Br86300
46.
go back to reference Poitras P, Backman D, Uhthoff HK, Schwammberger A. Creep properties of a bioresorbable polymer for an axially compressible fracture plate. Presented at the 5th Combined Meeting of the Orthopaedic Research Societies of Canada, USA, Japan and Europe. Banff, AB. October 2004 Poitras P, Backman D, Uhthoff HK, Schwammberger A. Creep properties of a bioresorbable polymer for an axially compressible fracture plate. Presented at the 5th Combined Meeting of the Orthopaedic Research Societies of Canada, USA, Japan and Europe. Banff, AB. October 2004
Metadata
Title
Internal plate fixation of fractures: short history and recent developments
Authors
Hans K. Uhthoff
Philippe Poitras
David S. Backman
Publication date
01-03-2006
Publisher
Springer-Verlag
Published in
Journal of Orthopaedic Science / Issue 2/2006
Print ISSN: 0949-2658
Electronic ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-005-0984-7

Other articles of this Issue 2/2006

Journal of Orthopaedic Science 2/2006 Go to the issue