Skip to main content
Top
Published in: Acta Neurochirurgica 7/2014

01-07-2014 | Clinical Article - Vascular

Intra-operative correction of brain-shift

Authors: Ingerid Reinertsen, Frank Lindseth, Christian Askeland, Daniel Høyer Iversen, Geirmund Unsgård

Published in: Acta Neurochirurgica | Issue 7/2014

Login to get access

Abstract

Background

Brain-shift is a major source of error in neuronavigation systems based on pre-operative images. In this paper, we present intra-operative correction of brain-shift using 3D ultrasound.

Methods

The method is based on image registration of vessels extracted from pre-operative MRA and intra-operative power Doppler-based ultrasound and is fully integrated in the neuronavigation software.

Results

We have performed correction of brain-shift in the operating room during surgery and provided the surgeon with updated information. Here, we present data from seven clinical cases with qualitative and quantitative error measures.

Conclusion

The registration algorithm is fast enough to provide the surgeon with updated information within minutes and accounts for large portions of the experienced shift. Correction of brain-shift can make pre-operative data like fMRI and DTI reliable for a longer period of time and increase the usefulness of the MR data as a supplement to intra-operative 3D ultrasound in terms of overview and interpretation.
Literature
1.
go back to reference Hill DLG, Maurer CR, Maciunas RJ, Barwise JA, Fitzpatrick JM, Wang MY (1998) Measurement of Intraoperative Brain Surface Deformation under a Craniotomy. Neurosurgery 43:514–528CrossRefPubMed Hill DLG, Maurer CR, Maciunas RJ, Barwise JA, Fitzpatrick JM, Wang MY (1998) Measurement of Intraoperative Brain Surface Deformation under a Craniotomy. Neurosurgery 43:514–528CrossRefPubMed
2.
go back to reference Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative Brain Shift and Deformation: A Quantitative Analysis of Cortical Displacement in 28 Cases. Neurosurgery 43:749–760CrossRefPubMed Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative Brain Shift and Deformation: A Quantitative Analysis of Cortical Displacement in 28 Cases. Neurosurgery 43:749–760CrossRefPubMed
3.
go back to reference Elias WJ, Fu K-M, Frysinger RC (2007) Cortical and subcortical brain shift during stereotactic procedures. J Neurosurg 107:983–988CrossRefPubMed Elias WJ, Fu K-M, Frysinger RC (2007) Cortical and subcortical brain shift during stereotactic procedures. J Neurosurg 107:983–988CrossRefPubMed
4.
go back to reference Miyagi Y, Shima F, Sasaki T (2007) Brain shift: an error factor during implantation of deep brain stimulation electrodes. J Neurosurg 107:989–997CrossRefPubMed Miyagi Y, Shima F, Sasaki T (2007) Brain shift: an error factor during implantation of deep brain stimulation electrodes. J Neurosurg 107:989–997CrossRefPubMed
5.
go back to reference Reinges MHT, Nguyen HH, Krings T, Hütter BO, Rohde V, Gilsbach JM (2004) Course of brain shift during microsurgical resection of supratentorial cerebral lesions: limits of conventional neuronavigation. Acta Neurochir 146:369–377CrossRefPubMed Reinges MHT, Nguyen HH, Krings T, Hütter BO, Rohde V, Gilsbach JM (2004) Course of brain shift during microsurgical resection of supratentorial cerebral lesions: limits of conventional neuronavigation. Acta Neurochir 146:369–377CrossRefPubMed
6.
go back to reference Jolesz FA (2011) Intraoperative imaging in neurosurgery: where will the future take us? Acta neurochirurgica. Supplement 109:21–25 Jolesz FA (2011) Intraoperative imaging in neurosurgery: where will the future take us? Acta neurochirurgica. Supplement 109:21–25
7.
go back to reference Nimsky C, Ganslandt O, von Keller B, Romstöck J, Fahlbusch R (2004) Intraoperative High-Field-Strength MR Imaging: Implementation and Experience in 200 Patients1. Radiology 233:67–78CrossRefPubMed Nimsky C, Ganslandt O, von Keller B, Romstöck J, Fahlbusch R (2004) Intraoperative High-Field-Strength MR Imaging: Implementation and Experience in 200 Patients1. Radiology 233:67–78CrossRefPubMed
8.
go back to reference Feigl GC, Safavi-Abbasi S, Gharabaghi A, Gonzalez-Felipe V, El Shawarby A, Freund HJ, Samii M (2008) Real-time 3T fMRI data of brain tumour patients for intra-operative localization of primary motor areas. Eur J Surg Oncol J Eur Soc Surg Oncol Br Assoc Surg Oncol 34:708–715 Feigl GC, Safavi-Abbasi S, Gharabaghi A, Gonzalez-Felipe V, El Shawarby A, Freund HJ, Samii M (2008) Real-time 3T fMRI data of brain tumour patients for intra-operative localization of primary motor areas. Eur J Surg Oncol J Eur Soc Surg Oncol Br Assoc Surg Oncol 34:708–715
9.
go back to reference Vassal F, Schneider F, Nuti C (2013) Intraoperative use of diffusion tensor imaging-based tractography for resection of gliomas located near the pyramidal tract: comparison with subcortical stimulation mapping and contribution to surgical outcomes. Br J Neurosurg doi:10.3109/02688697.2013.771730 Vassal F, Schneider F, Nuti C (2013) Intraoperative use of diffusion tensor imaging-based tractography for resection of gliomas located near the pyramidal tract: comparison with subcortical stimulation mapping and contribution to surgical outcomes. Br J Neurosurg doi:10.​3109/​02688697.​2013.​771730
10.
go back to reference Foroglou N, Zamani A, Black P (2009) Intra-operative MRI (iop-MR) for brain tumour surgery. Br J Neurosurg 23:14–22CrossRefPubMed Foroglou N, Zamani A, Black P (2009) Intra-operative MRI (iop-MR) for brain tumour surgery. Br J Neurosurg 23:14–22CrossRefPubMed
11.
go back to reference Jankovski A, Francotte F, Vaz G, Fomekong E, Duprez T, Van Boven M, Docquier MA, Hermoye L, Cosnard G, Raftopoulos C (2008) Intraoperative magnetic resonance imaging at 3-T using a dual independent operating room-magnetic resonance imaging suite: development, feasibility, safety, and preliminary experience. Neurosurgery 63:412–424, discussion 424–416CrossRefPubMed Jankovski A, Francotte F, Vaz G, Fomekong E, Duprez T, Van Boven M, Docquier MA, Hermoye L, Cosnard G, Raftopoulos C (2008) Intraoperative magnetic resonance imaging at 3-T using a dual independent operating room-magnetic resonance imaging suite: development, feasibility, safety, and preliminary experience. Neurosurgery 63:412–424, discussion 424–416CrossRefPubMed
12.
go back to reference Unsgaard G, Rygh OM, Selbekk T, Muller TB, Kolstad F, Lindseth F, Hernes TA (2006) Intra-operative 3D ultrasound in neurosurgery. Acta Neurochir 148:235–253, discussion 253CrossRefPubMed Unsgaard G, Rygh OM, Selbekk T, Muller TB, Kolstad F, Lindseth F, Hernes TA (2006) Intra-operative 3D ultrasound in neurosurgery. Acta Neurochir 148:235–253, discussion 253CrossRefPubMed
13.
go back to reference Lindseth F, Bang J, Lango T (2003) A robust and automatic method for evaluating accuracy in 3-D ultrasound-based navigation. Ultrasound Med Biol 29:1439–1452CrossRefPubMed Lindseth F, Bang J, Lango T (2003) A robust and automatic method for evaluating accuracy in 3-D ultrasound-based navigation. Ultrasound Med Biol 29:1439–1452CrossRefPubMed
14.
go back to reference Lindseth F, Lango T, Bang J, Nagelhus Hernes TA (2002) Accuracy evaluation of a 3D ultrasound-based neuronavigation system. Comput Aided Surg 7:197–222CrossRefPubMed Lindseth F, Lango T, Bang J, Nagelhus Hernes TA (2002) Accuracy evaluation of a 3D ultrasound-based neuronavigation system. Comput Aided Surg 7:197–222CrossRefPubMed
15.
go back to reference Coupe P, Hellier P, Morandi X, Barillot C (2012) 3D Rigid Registration of Intraoperative Ultrasound and Preoperative MR Brain Images Based on Hyperechogenic Structures. Int J Biomed Imaging 2012:1–14CrossRef Coupe P, Hellier P, Morandi X, Barillot C (2012) 3D Rigid Registration of Intraoperative Ultrasound and Preoperative MR Brain Images Based on Hyperechogenic Structures. Int J Biomed Imaging 2012:1–14CrossRef
16.
go back to reference Nigris D, Collins DL, Arbel T (2012) Fast and Robust Registration Based on Gradient Orientations: Case Study Matching Intra-operative Ultrasound to Pre-operative MRI in Neurosurgery. In: Abolmaesumi P, Joskowicz L, Navab N, Jannin P (eds) Information Processing in Computer-Assisted Interventions. (Lecture Notes in Computer Science), vol 7330. Springer Berlin Heidelberg, Berlin Heidelberg, pp 125–134CrossRef Nigris D, Collins DL, Arbel T (2012) Fast and Robust Registration Based on Gradient Orientations: Case Study Matching Intra-operative Ultrasound to Pre-operative MRI in Neurosurgery. In: Abolmaesumi P, Joskowicz L, Navab N, Jannin P (eds) Information Processing in Computer-Assisted Interventions. (Lecture Notes in Computer Science), vol 7330. Springer Berlin Heidelberg, Berlin Heidelberg, pp 125–134CrossRef
17.
go back to reference Roche A, Pennec X, Malandin G, Ayache N (2001) Rigid Registration of 3D Ultrasound with MR Images: A New Approach Combining intensity and Gradient Information. IEEE Trans Med Imaging 20:1038–1049CrossRefPubMed Roche A, Pennec X, Malandin G, Ayache N (2001) Rigid Registration of 3D Ultrasound with MR Images: A New Approach Combining intensity and Gradient Information. IEEE Trans Med Imaging 20:1038–1049CrossRefPubMed
18.
go back to reference Reinertsen I, Descoteaux M, Siddiqi K, Collins DL (2007) Validation of vessel-based registration for correction of brain shift. Med Image Anal 11:374–388CrossRefPubMed Reinertsen I, Descoteaux M, Siddiqi K, Collins DL (2007) Validation of vessel-based registration for correction of brain shift. Med Image Anal 11:374–388CrossRefPubMed
19.
go back to reference Reinertsen I, Lindseth F, Unsgaard G, Collins DL (2007) Clinical validation of vessel-based registration for correction of brain-shift. Med Image Anal 11:673–684CrossRefPubMed Reinertsen I, Lindseth F, Unsgaard G, Collins DL (2007) Clinical validation of vessel-based registration for correction of brain-shift. Med Image Anal 11:673–684CrossRefPubMed
20.
go back to reference Askeland C, Lindseth F, Bakeng JBL, Solberg OV, Tangen GA (2011) CustusX: A Research Application for Image-Guided Therapy. Insight J 1–8 Askeland C, Lindseth F, Bakeng JBL, Solberg OV, Tangen GA (2011) CustusX: A Research Application for Image-Guided Therapy. Insight J 1–8
21.
go back to reference Lindseth F, Tangen GA, Lango T, Bang J (2003) Probe calibration for freehand 3-D ultrasound. Ultrasound Med Biol 29:1607–1623CrossRefPubMed Lindseth F, Tangen GA, Lango T, Bang J (2003) Probe calibration for freehand 3-D ultrasound. Ultrasound Med Biol 29:1607–1623CrossRefPubMed
22.
go back to reference Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. NeuroImage 31:1116–1128CrossRefPubMed Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. NeuroImage 31:1116–1128CrossRefPubMed
23.
go back to reference Lee BK, Gobbi DG, Peters T (2000) Vascular tree extraction from mra and power doppler us image volumes. Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE, vol 3. IEEE, pp 1731–1733 Lee BK, Gobbi DG, Peters T (2000) Vascular tree extraction from mra and power doppler us image volumes. Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE, vol 3. IEEE, pp 1731–1733
24.
go back to reference Homann H (2007) Implementation of a 3D thinning algorithm. Insight J 1–4 Homann H (2007) Implementation of a 3D thinning algorithm. Insight J 1–4
25.
go back to reference Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. Pattern Anal Mach Intell IEEE Trans 14:239–256CrossRef Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. Pattern Anal Mach Intell IEEE Trans 14:239–256CrossRef
26.
go back to reference Rousseeuw PJ, Leroy AM (2005) Robust regression and outlier detection. Wiley, Hoboken Rousseeuw PJ, Leroy AM (2005) Robust regression and outlier detection. Wiley, Hoboken
Metadata
Title
Intra-operative correction of brain-shift
Authors
Ingerid Reinertsen
Frank Lindseth
Christian Askeland
Daniel Høyer Iversen
Geirmund Unsgård
Publication date
01-07-2014
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 7/2014
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-014-2052-6

Other articles of this Issue 7/2014

Acta Neurochirurgica 7/2014 Go to the issue