Skip to main content
Top
Published in: Acta Neurochirurgica 6/2009

01-06-2009 | Technique Evaluation

Polymer gel in rat skull to assess the accuracy of a new rat stereotactic device for use with the Gamma Knife

Authors: Gabriel Charest, David Mathieu, Martin Lepage, David Fortin, Benoit Paquette, Léon Sanche

Published in: Acta Neurochirurgica | Issue 6/2009

Login to get access

Abstract

Purpose

Accurate targeting is crucial for the irradiation of a small-volume animal brain. We propose an original method, based on a polymer gel, to determine the accuracy and reproducibility of irradiation using a new stereotactic frame.

Methods

An in-house designed rat stereotactic frame, compatible with the Gamma Knife, was constructed. The rat brain was then removed through a small burr hole and the intracranial cavity was washed and filled with a polymer gel. This “gel brain” was irradiated by Gamma Knife and the irradiated volumes and coordinates were measured after the irradiation.

Results

The position of the polymerized areas revealed that the stereotactic frame was able to accurately reproduce the same position of irradiation in each animal. The small standard deviation demonstrated the high reproducibility.

Conclusion

The polymer gel confirmed the ability of the rat stereotactic frame to accurately and reproducibly position a small animal for precise radiosurgery procedures.
Literature
2.
go back to reference Blanchard J, Mathieu D, Patenaude Y, Fortin D (2006) MR-pathological comparison in F98-Fischer glioma model using a human gantry. Can J Neurol Sci 33:86–91PubMed Blanchard J, Mathieu D, Patenaude Y, Fortin D (2006) MR-pathological comparison in F98-Fischer glioma model using a human gantry. Can J Neurol Sci 33:86–91PubMed
4.
go back to reference Herynek V, Burian M, Jirak D, Liscak R, Namestkova K, Hajek M, Sykova E (2004) Metabolite and diffusion changes in the rat brain after Leksell Gamma Knife irradiation. Magn Reson Med 52:397–402. doi:10.1002/mrm.20150 PubMedCrossRef Herynek V, Burian M, Jirak D, Liscak R, Namestkova K, Hajek M, Sykova E (2004) Metabolite and diffusion changes in the rat brain after Leksell Gamma Knife irradiation. Magn Reson Med 52:397–402. doi:10.​1002/​mrm.​20150 PubMedCrossRef
6.
go back to reference Im YS, Nam DH, Kim JS, Ju SG, Lim DH, Lee JI (2006) Stereotactic device for Gamma Knife radiosurgery in experimental animals: technical note. Stereotact Funct Neurosurg 84:97–102. doi:10.1159/000094367 PubMedCrossRef Im YS, Nam DH, Kim JS, Ju SG, Lim DH, Lee JI (2006) Stereotactic device for Gamma Knife radiosurgery in experimental animals: technical note. Stereotact Funct Neurosurg 84:97–102. doi:10.​1159/​000094367 PubMedCrossRef
7.
go back to reference Kamiryo T, Berk HW, Lee KS, Kassell NF, Steiner L (1993) A stereotactic device for experimental gamma knife radiosurgery in rats. A technical note. Acta Neurochir (Wien) 125:156–160. doi:10.1007/BF01401844 CrossRef Kamiryo T, Berk HW, Lee KS, Kassell NF, Steiner L (1993) A stereotactic device for experimental gamma knife radiosurgery in rats. A technical note. Acta Neurochir (Wien) 125:156–160. doi:10.​1007/​BF01401844 CrossRef
8.
go back to reference Karger CP, Hartmann GH, Peschke P, Debus J, Hoffmann U, Brix G, Hahn EW, Lorenz WJ (1997) Dose-response relationship for late functional changes in the rat brain after radiosurgery evaluated by magnetic resonance imaging. Int J Radiat Oncol Biol Phys 39:1163–1172. doi:10.1016/S0360-3016(97)00387-8 PubMed Karger CP, Hartmann GH, Peschke P, Debus J, Hoffmann U, Brix G, Hahn EW, Lorenz WJ (1997) Dose-response relationship for late functional changes in the rat brain after radiosurgery evaluated by magnetic resonance imaging. Int J Radiat Oncol Biol Phys 39:1163–1172. doi:10.​1016/​S0360-3016(97)00387-8 PubMed
9.
go back to reference Mathieu D, Lecomte R, Tsanaclis AM, Larouche A, Fortin D (2007) Standardization and detailed characterization of the syngeneic Fischer/F98 glioma model. Can J Neurol Sci 34:296–306PubMed Mathieu D, Lecomte R, Tsanaclis AM, Larouche A, Fortin D (2007) Standardization and detailed characterization of the syngeneic Fischer/F98 glioma model. Can J Neurol Sci 34:296–306PubMed
10.
go back to reference McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, Leach MO, Webb S (2000) Radiation dosimetry using polymer gels: methods and applications. Br J Radiol 73:919–929PubMed McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, Leach MO, Webb S (2000) Radiation dosimetry using polymer gels: methods and applications. Br J Radiol 73:919–929PubMed
11.
go back to reference Novotny J Jr, Novotny J, Spevacek V, Dvorak P, Cechak T, Liscak R, Brozek G, Tintera J, Vymazal J (2002) Evaluation of geometric and dosimetric inaccuracies of stereotactic irradiation in the rat brain. Stereotact Funct Neurosurg 79:57–74. doi:10.1159/000070102 PubMedCrossRef Novotny J Jr, Novotny J, Spevacek V, Dvorak P, Cechak T, Liscak R, Brozek G, Tintera J, Vymazal J (2002) Evaluation of geometric and dosimetric inaccuracies of stereotactic irradiation in the rat brain. Stereotact Funct Neurosurg 79:57–74. doi:10.​1159/​000070102 PubMedCrossRef
12.
go back to reference Novotny J Jr, Novotny J, Spevacek V, Dvorak P, Cechak T, Liscak R, Brozek G, Tintera J, Vymazal J (2002) Application of polymer gel dosimetry in gamma knife radiosurgery. J Neurosurg 97:556–562PubMed Novotny J Jr, Novotny J, Spevacek V, Dvorak P, Cechak T, Liscak R, Brozek G, Tintera J, Vymazal J (2002) Application of polymer gel dosimetry in gamma knife radiosurgery. J Neurosurg 97:556–562PubMed
13.
go back to reference Paxinos G, Watson C (2004) The rat brain in stereotaxic coordinates, 5th edn. Elsevier Academic Press, Burlington San Diego London Paxinos G, Watson C (2004) The rat brain in stereotaxic coordinates, 5th edn. Elsevier Academic Press, Burlington San Diego London
14.
go back to reference Tokumaru O, Hayashi M, Katayama Y, Tomida M, Kawakami Y, Kouyama N (2007) Gamma knife radiosurgery targeting protocols for the experiments with small animals. Stereotact Funct Neurosurg 85:135–143. doi:10.1159/000099071 PubMedCrossRef Tokumaru O, Hayashi M, Katayama Y, Tomida M, Kawakami Y, Kouyama N (2007) Gamma knife radiosurgery targeting protocols for the experiments with small animals. Stereotact Funct Neurosurg 85:135–143. doi:10.​1159/​000099071 PubMedCrossRef
15.
go back to reference Tokumaru O, Tomida M, Katayama Y, Hayashi M, Kawakami Y, Kouyama N (2005) The effect of gamma knife irradiation on functions of striatum in rats. J Neurosurg 102(suppl):42–48PubMedCrossRef Tokumaru O, Tomida M, Katayama Y, Hayashi M, Kawakami Y, Kouyama N (2005) The effect of gamma knife irradiation on functions of striatum in rats. J Neurosurg 102(suppl):42–48PubMedCrossRef
Metadata
Title
Polymer gel in rat skull to assess the accuracy of a new rat stereotactic device for use with the Gamma Knife
Authors
Gabriel Charest
David Mathieu
Martin Lepage
David Fortin
Benoit Paquette
Léon Sanche
Publication date
01-06-2009
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 6/2009
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-009-0298-1

Other articles of this Issue 6/2009

Acta Neurochirurgica 6/2009 Go to the issue