Abstract

Aims

The aim of the study was (a) to compare annual glycemic control in pediatric patients with type 1 diabetes mellitus (T1DM) who used a healthcare-funded continuous glucose monitoring system (RT-CGMS) to that of those who performed self-monitoring blood glucose (SMBG) only, in a real-life setting, and (b) to define parameters associated with compliance and glycemic control.

Methods

A total of 149 youth with T1DM (52.3 % females), mean age 11.8 ± 3.6 years, and 83 in the CGMS group were followed prospectively for 12 months. Glycemic control parameters and compliance to RT-CGMS were assessed periodically.

Results

Glycemic parameters did not differ significantly between the groups during follow-up periods. The time spent with RT-CGMS decreased and only 38 % used it for more than 75 % of the time during the 12 months (consistent users). Mean HbA1c decreased by 0.27 % in consistent users and increased by 0.21 % among intermittent users (used RT-CGMS less than 75 % of time), p = 0.013. Consistent users were younger 10. 6 ± 4.2 vs. 12.5 ± 3.6, p = 0.07, and had higher frequency of SMBG at baseline, 10.6 ± 4.9 vs. 6.3 ± 2.8, p = 0.011.

Conclusions

The adoption of RT-CGMS was low, even in a healthcare system that funds its use. Caregivers should consider patient characteristics when recommending RT-CGMS use.
Literature
1.
go back to reference Reichard P, Nilsson BY, Rosenqvist U; The Diabetes Control and Complications Trial Research Group (1993) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329(5):304–309 Reichard P, Nilsson BY, Rosenqvist U; The Diabetes Control and Complications Trial Research Group (1993) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329(5):304–309
2.
go back to reference The Diabetes Control and Complications Trial Research Group (1994) Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: diabetes control and complications trial. J Pediatr 125:177–188 The Diabetes Control and Complications Trial Research Group (1994) Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: diabetes control and complications trial. J Pediatr 125:177–188
3.
go back to reference Petitti DB, Klingensmith GJ, Bell RA et al (2009) Glycemic control in youth with diabetes: the SEARCH for diabetes in Youth Study. J Pediatr 155:668–672 (e661–663) Petitti DB, Klingensmith GJ, Bell RA et al (2009) Glycemic control in youth with diabetes: the SEARCH for diabetes in Youth Study. J Pediatr 155:668–672 (e661–663)
4.
go back to reference Wood JR, Miller KM, Maahs DM et al (2013) Most youth with type 1 diabetes in the T1D exchange clinic registry do not meet American Diabetes Association or International Society for Pediatric and Adolescent Diabetes clinical guidelines. Diabetes Care 36(7):2035–2037 Wood JR, Miller KM, Maahs DM et al (2013) Most youth with type 1 diabetes in the T1D exchange clinic registry do not meet American Diabetes Association or International Society for Pediatric and Adolescent Diabetes clinical guidelines. Diabetes Care 36(7):2035–2037
5.
go back to reference Beck RW, Tamborlane WV, Bergenstal RM, Miller KM, DuBose SN, Hall CA (2012) The T1D exchange clinic registry. J Clin Endocrinol Metab 97:4383–4389CrossRefPubMed Beck RW, Tamborlane WV, Bergenstal RM, Miller KM, DuBose SN, Hall CA (2012) The T1D exchange clinic registry. J Clin Endocrinol Metab 97:4383–4389CrossRefPubMed
6.
go back to reference Golicki DT, Golicka D, Groele L, Pankowska E (2008) Continuous glucose monitoring system in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia 51:233–240CrossRefPubMed Golicki DT, Golicka D, Groele L, Pankowska E (2008) Continuous glucose monitoring system in children with type 1 diabetes mellitus: a systematic review and meta-analysis. Diabetologia 51:233–240CrossRefPubMed
7.
go back to reference Tamborlane WV, Beck RW, Bode BW et al (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359:1464–1476CrossRefPubMed Tamborlane WV, Beck RW, Bode BW et al (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359:1464–1476CrossRefPubMed
8.
go back to reference Norgaard K, Scaramuzza A, Bratina N et al (2013) Routine sensor-augmented pump therapy in type 1 diabetes: the INTERPRET study. Diabetes Technol Ther 15:273–280CrossRefPubMedCentralPubMed Norgaard K, Scaramuzza A, Bratina N et al (2013) Routine sensor-augmented pump therapy in type 1 diabetes: the INTERPRET study. Diabetes Technol Ther 15:273–280CrossRefPubMedCentralPubMed
9.
go back to reference Nallamothu BK, Hayward RA, Bates ER (2008) Beyond the randomized clinical trial: the role of effectiveness studies in evaluating cardiovascular therapies. Circulation 118:1294–1303CrossRefPubMed Nallamothu BK, Hayward RA, Bates ER (2008) Beyond the randomized clinical trial: the role of effectiveness studies in evaluating cardiovascular therapies. Circulation 118:1294–1303CrossRefPubMed
10.
go back to reference Mortensen HB (2002) Findings from the Hvidore Study Group on childhood diabetes: metabolic control and quality of life. Horm Res 57(Suppl 1):117–120CrossRefPubMed Mortensen HB (2002) Findings from the Hvidore Study Group on childhood diabetes: metabolic control and quality of life. Horm Res 57(Suppl 1):117–120CrossRefPubMed
11.
go back to reference Wentholt IM, Hoekstra JB, Devries JH (2007) Continuous glucose monitors: the long-awaited watch dogs? Diabetes Technol Ther 9:399–409CrossRefPubMed Wentholt IM, Hoekstra JB, Devries JH (2007) Continuous glucose monitors: the long-awaited watch dogs? Diabetes Technol Ther 9:399–409CrossRefPubMed
12.
go back to reference Cemeroglu AP, Stone R, Kleis L, Racine MS, Postellon DC, Wood MA (2010) Use of a real-time continuous glucose monitoring system in children and young adults on insulin pump therapy: patients’ and caregivers’ perception of benefit. Pediatr Diabetes 11:182–187CrossRefPubMed Cemeroglu AP, Stone R, Kleis L, Racine MS, Postellon DC, Wood MA (2010) Use of a real-time continuous glucose monitoring system in children and young adults on insulin pump therapy: patients’ and caregivers’ perception of benefit. Pediatr Diabetes 11:182–187CrossRefPubMed
13.
go back to reference Yeh HC, Brown TT, Maruthur N et al (2012) Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis. Ann Intern Med 157:336–347CrossRefPubMed Yeh HC, Brown TT, Maruthur N et al (2012) Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis. Ann Intern Med 157:336–347CrossRefPubMed
14.
go back to reference Mastrototaro J, Welsh JB, Lee S (2010) Practical considerations in the use of real-time continuous glucose monitoring alerts. J Diabetes Sci Technol 4:733–739CrossRefPubMedCentralPubMed Mastrototaro J, Welsh JB, Lee S (2010) Practical considerations in the use of real-time continuous glucose monitoring alerts. J Diabetes Sci Technol 4:733–739CrossRefPubMedCentralPubMed
15.
go back to reference Pickup JC, Freeman SC, Sutton AJ (2011) Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ 343:d3805CrossRefPubMedCentralPubMed Pickup JC, Freeman SC, Sutton AJ (2011) Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ 343:d3805CrossRefPubMedCentralPubMed
16.
go back to reference Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJ (2012) Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev 1:CD008101 Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJ (2012) Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev 1:CD008101
17.
go back to reference Beck RW, Buckingham B, Miller K et al (2009) Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 32:1947–1953CrossRefPubMed Beck RW, Buckingham B, Miller K et al (2009) Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 32:1947–1953CrossRefPubMed
18.
go back to reference Battelino T, Conget I, Olsen B et al (2012) The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial. Diabetologia 55:3155–3162CrossRefPubMedCentralPubMed Battelino T, Conget I, Olsen B et al (2012) The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial. Diabetologia 55:3155–3162CrossRefPubMedCentralPubMed
Metadata
Title
The use of continuous glucose monitoring systems in a pediatric population with type 1 diabetes mellitus in real-life settings: the AWeSoMe Study Group experience
Authors
M. Rachmiel
Z. Landau
M. Boaz
K. Mazor Aronovitch
N. Loewenthal
M. Ben-Ami
Y. Levy-Shraga
D. Modan-Moses
A. Haim
S. Abiri
O. Pinhas-Hamiel
Publication date
01-04-2015
Publisher
Springer Milan
Published in
Acta Diabetologica / Issue 2/2015
Print ISSN: 0940-5429
Electronic ISSN: 1432-5233
DOI
https://doi.org/10.1007/s00592-014-0643-6

Other articles of this Issue 2/2015

Acta Diabetologica 2/2015 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine