Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 3/2020

01-04-2020 | General Review • HIP - FRACTURES

Bipolar versus monopolar hemiarthroplasty for displaced femur neck fractures: a meta-analysis study

Authors: Migliorini Filippo, Arne Driessen, Giorgia Colarossi, Valentin Quack, Markus Tingart, Jörg Eschweiler

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 3/2020

Login to get access

Abstract

Introduction

Hemiarthroplasty is commonly performed to treat femoral neck fractures. Still, there is a lack of consensus concerning the best component for hemiarthroplasty: unipolar and bipolar implants. Last meta-analysis on this topic is outdated, and an update of current evidences is required. The purpose of this study is to conduct a meta-analysis comparing the unipolar versus bipolar implants for hemiarthroplasty, focusing on the clinical scores, perioperative data, further complications and mortality rate.

Materials and methods

In September 2019, the main databases were accessed: all the clinical trials comparing unipolar versus bipolar hemiarthroplasty for displaced femoral neck fractures were considered for inclusion. For the methodological quality assessment, we referred to the PEDro score. For the statistical analysis, we referred to the Review Manager 5.3 (The Nordic Cochrane Collaboration, Copenhagen). For implant survivorship, we referred to the STATA/MP software version 14.1 (StataCorp, College Station, Texas).

Results

A total of 27 articles were considered for inclusion, consisting of 16 randomized and 11 non-randomized clinical trials. A total of 4511 patients were enrolled, undergoing a mean 21.26 months follow-up. A statistically significant reduction in the acetabular erosion was observed in the bipolar group (OR 3.16, P < 0.0001). Although statistically insignificant, the bipolar group reported a reduction in the mean Harris hip score, reduced surgical duration and hospitalization, reduced dislocation and revisions rate. Concerning the mortality, a reduction across all the follow-ups in favor of the bipolar group was detected, but without statistically significance.

Conclusions

This meta-analysis evidenced a reduction in the acetabular erosion after bipolar hemiarthroplasty compared to the unipolar implants. Any statistically significant difference concerning the other endpoints of interest was detected. Current evidence concerning this topic are controversial, and further randomized clinical trials are required.
Literature
2.
go back to reference Miyamoto RG, Kaplan KM, Levine BR, Egol KA, Zuckerman JD (2008) Surgical management of hip fractures: an evidence-based review of the literature. I: femoral neck fractures. J Am Acad Orthop Surg 16(10):596–607CrossRef Miyamoto RG, Kaplan KM, Levine BR, Egol KA, Zuckerman JD (2008) Surgical management of hip fractures: an evidence-based review of the literature. I: femoral neck fractures. J Am Acad Orthop Surg 16(10):596–607CrossRef
6.
go back to reference Gilbert MS, Capozzi J (1998) Unipolar or bipolar prosthesis for the displaced intracapsular hip fracture? An unanswered question. Clin Orthop Relat Res 353:81–85CrossRef Gilbert MS, Capozzi J (1998) Unipolar or bipolar prosthesis for the displaced intracapsular hip fracture? An unanswered question. Clin Orthop Relat Res 353:81–85CrossRef
10.
go back to reference Calder SJ, Anderson GH, Jagger C, Harper WM, Gregg PJ (1996) Unipolar or bipolar prosthesis for displaced intracapsular hip fracture in octogenarians: a randomised prospective study. J Bone Joint Surg Br 78(3):391–394CrossRef Calder SJ, Anderson GH, Jagger C, Harper WM, Gregg PJ (1996) Unipolar or bipolar prosthesis for displaced intracapsular hip fracture in octogenarians: a randomised prospective study. J Bone Joint Surg Br 78(3):391–394CrossRef
11.
go back to reference Ng DZ, Lee KB (2015) Unipolar versus bipolar hemiarthroplasty for displaced femoral neck fractures in the elderly: is there a difference? Ann Acad Med Singapore 44(6):197–201PubMed Ng DZ, Lee KB (2015) Unipolar versus bipolar hemiarthroplasty for displaced femoral neck fractures in the elderly: is there a difference? Ann Acad Med Singapore 44(6):197–201PubMed
14.
go back to reference Howick JCI, Glasziou P, Greenhalgh T, Carl Heneghan, Liberati A, Moschetti I, Phillips B, Thornton H, Goddard O, Hodgkinson M (2011) The 2011 Oxford CEBM levels of evidence. Oxford Centre for Evidence-Based Medicine. https://www.cebmnet/indexaspx?o=5653 Howick JCI, Glasziou P, Greenhalgh T, Carl Heneghan, Liberati A, Moschetti I, Phillips B, Thornton H, Goddard O, Hodgkinson M (2011) The 2011 Oxford CEBM levels of evidence. Oxford Centre for Evidence-Based Medicine. https://​www.​cebmnet/​indexaspx?​o=​5653
16.
go back to reference Ahmed MJ, Shahid M, Ahmed MH, Nazar B (2018) Intracapsular femoral neck fractures; comparison of functional outcomes in unipolar versus bipolar uncemented hemiarthroplasty in elderly patients. Prof Med J 25(9):1317–1322 Ahmed MJ, Shahid M, Ahmed MH, Nazar B (2018) Intracapsular femoral neck fractures; comparison of functional outcomes in unipolar versus bipolar uncemented hemiarthroplasty in elderly patients. Prof Med J 25(9):1317–1322
17.
go back to reference Ali AA, Rashed SM, Hussien MT (2014) Unipolar versus bipolar hip hemiarthroplasty in the treatment of femoral neck fractures in the elderly. Iraqi Postgrad Med J 13(4):475–485 Ali AA, Rashed SM, Hussien MT (2014) Unipolar versus bipolar hip hemiarthroplasty in the treatment of femoral neck fractures in the elderly. Iraqi Postgrad Med J 13(4):475–485
20.
go back to reference Cornell CN, Levine D, O’Doherty J, Lyden J (1998) Unipolar versus bipolar hemiarthroplasty for the treatment of femoral neck fractures in the elderly. Clin Orthop Relat Res 348:67–71CrossRef Cornell CN, Levine D, O’Doherty J, Lyden J (1998) Unipolar versus bipolar hemiarthroplasty for the treatment of femoral neck fractures in the elderly. Clin Orthop Relat Res 348:67–71CrossRef
21.
go back to reference Davison JN, Calder SJ, Anderson GH, Ward G, Jagger C, Harper WM, Gregg PJ (2001) Treatment for displaced intracapsular fracture of the proximal femur. A prospective, randomised trial in patients aged 65 to 79 years. J Bone Joint Surg Br 83(2):206–212CrossRef Davison JN, Calder SJ, Anderson GH, Ward G, Jagger C, Harper WM, Gregg PJ (2001) Treatment for displaced intracapsular fracture of the proximal femur. A prospective, randomised trial in patients aged 65 to 79 years. J Bone Joint Surg Br 83(2):206–212CrossRef
28.
go back to reference Malhotra R, Arya R, Bhan S (1995) Bipolar hemiarthroplasty in femoral neck fractures. Arch Orthop Trauma Surg 114(2):79–82CrossRef Malhotra R, Arya R, Bhan S (1995) Bipolar hemiarthroplasty in femoral neck fractures. Arch Orthop Trauma Surg 114(2):79–82CrossRef
29.
go back to reference Mishra AK, Chalise PK, Shah SB, Adhikari V, Singh RP (2013) Comparative study in surgical outcome of intracapsular fracture neck of femur in active elderly patients treated with hemiarthroplasty with Austin Moore’s and bipolar prosthesis. Nepal Med Coll J 15(1):81–83PubMed Mishra AK, Chalise PK, Shah SB, Adhikari V, Singh RP (2013) Comparative study in surgical outcome of intracapsular fracture neck of femur in active elderly patients treated with hemiarthroplasty with Austin Moore’s and bipolar prosthesis. Nepal Med Coll J 15(1):81–83PubMed
34.
go back to reference Shah RM, Patel DA, Rathi N (2015) A comparative study of outcomes of unipolar versus bipolar hemi-arthroplasty in geriatric age group—a study of 60 cases. Int J Sci Eng Res 6(12):1186–1219 Shah RM, Patel DA, Rathi N (2015) A comparative study of outcomes of unipolar versus bipolar hemi-arthroplasty in geriatric age group—a study of 60 cases. Int J Sci Eng Res 6(12):1186–1219
36.
go back to reference Vishwanath C, Mummigatti SB (2017) Comparative study between Austin Moore prosthesis and bipolar prosthesis in fracture neck of femur. Clin Orthop 1(2):53–61 Vishwanath C, Mummigatti SB (2017) Comparative study between Austin Moore prosthesis and bipolar prosthesis in fracture neck of femur. Clin Orthop 1(2):53–61
37.
go back to reference Wathne RA, Koval KJ, Aharonoff GB, Zuckerman JD, Jones DA (1995) Modular unipolar versus bipolar prosthesis: a prospective evaluation of functional outcome after femoral neck fracture. J Orthop Trauma 9(4):298–302CrossRef Wathne RA, Koval KJ, Aharonoff GB, Zuckerman JD, Jones DA (1995) Modular unipolar versus bipolar prosthesis: a prospective evaluation of functional outcome after femoral neck fracture. J Orthop Trauma 9(4):298–302CrossRef
40.
go back to reference Tidermark J, Ponzer S, Svensson O, Soderqvist A, Tornkvist H (2003) Internal fixation compared with total hip replacement for displaced femoral neck fractures in the elderly. A randomised, controlled trial. J Bone Joint Surg Br 85(3):380–388CrossRef Tidermark J, Ponzer S, Svensson O, Soderqvist A, Tornkvist H (2003) Internal fixation compared with total hip replacement for displaced femoral neck fractures in the elderly. A randomised, controlled trial. J Bone Joint Surg Br 85(3):380–388CrossRef
41.
go back to reference Phillips TW (1987) The Bateman bipolar femoral head replacement. A fluoroscopic study of movement over a four-year period. J Bone Joint Surg Br 69(5):761–764CrossRef Phillips TW (1987) The Bateman bipolar femoral head replacement. A fluoroscopic study of movement over a four-year period. J Bone Joint Surg Br 69(5):761–764CrossRef
45.
go back to reference Cornwall R, Gilbert MS, Koval KJ, Strauss E, Siu AL (2004) Functional outcomes and mortality vary among different types of hip fractures: a function of patient characteristics. Clin Orthop Relat Res 425:64–71CrossRef Cornwall R, Gilbert MS, Koval KJ, Strauss E, Siu AL (2004) Functional outcomes and mortality vary among different types of hip fractures: a function of patient characteristics. Clin Orthop Relat Res 425:64–71CrossRef
Metadata
Title
Bipolar versus monopolar hemiarthroplasty for displaced femur neck fractures: a meta-analysis study
Authors
Migliorini Filippo
Arne Driessen
Giorgia Colarossi
Valentin Quack
Markus Tingart
Jörg Eschweiler
Publication date
01-04-2020
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 3/2020
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-019-02600-6

Other articles of this Issue 3/2020

European Journal of Orthopaedic Surgery & Traumatology 3/2020 Go to the issue