Skip to main content
Top
Published in: European Spine Journal 6/2016

01-06-2016 | Original Article

A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine

Authors: Yong Hu, Zhen-shan Yuan, William Ryan Spiker, Wei-xin Dong, Xiao-yang Sun, Jian-bing Yuan, Jiao Zhang, Bingke Zhu

Published in: European Spine Journal | Issue 6/2016

Login to get access

Abstract

Purpose

The aim of this study was to assess the accuracy of rapid prototyping drill template technique for placing pedicle screws in the mid-upper thoracic vertebrae in clinics.

Methods

151 consecutive patients underwent thoracic instrumentation and fusion for a total of 582 pedicle screws placed in the mid-upper thoracic vertebrae. Using computer software, the authors constructed drill templates that fit onto the posterior elements of the mid-upper thoracic vertebrae with drill guides designed to instrument the pedicles. The start point and three dimensional location of the planned and inserted screws were measured and compared.

Results

Grading of the CT scans revealed 559 (96.1 %) out of 582 screws completely within the desired pedicle. The direction of pedicle violation included 5 medial, 2 airball, and 16 lateral. The paired t test suggested that these results were statistically significant in more than half of the locations (T1-left-TA(P = 0.024), T2-left-SA(P = 0.031), T3-left-SA(P = 0.014), T4-left-TA(P = 0.004), T5-left-TA(P = 0.034), T7-left-TA(P = 0.000). T1-right-TA(P = 0.049), T2-right-TA(P = 0.044), T3-right-TA(P = 0.014), T5-right-TA(P = 0.013)). The paired t-test suggested that these results were statistically significant at several locations (T4-left-Δy(P = 0.041), T5-left-Δx(P = 0.016), T3-right-Δy(P = 0.015)).

Conclusion

Use of a rapid prototyping drill template to assist in the placement of mid and upper thoracic pedicle screws may lead to increased accuracy. This patient specific technology must be combined with an understanding of the patients’ anatomy and carefully secured to the posterior elements intraoperatively to avoid nerve or vascular complications.
Literature
1.
go back to reference Gaines Jr RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476 Gaines Jr RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476
2.
go back to reference Bydon M, Xu R, Amin AG et al (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328CrossRefPubMed Bydon M, Xu R, Amin AG et al (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328CrossRefPubMed
3.
go back to reference Vanek P, Bradac O, Konopkova R et al (2014) Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine 20:150–156CrossRefPubMed Vanek P, Bradac O, Konopkova R et al (2014) Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine 20:150–156CrossRefPubMed
4.
go back to reference Hackenberg L, Link T, Liljenqvist U (2002) Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine 27:937–942CrossRefPubMed Hackenberg L, Link T, Liljenqvist U (2002) Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine 27:937–942CrossRefPubMed
5.
go back to reference Lee SM, Suk SI, Chung ER (2004) Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine 29:343–349CrossRefPubMed Lee SM, Suk SI, Chung ER (2004) Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine 29:343–349CrossRefPubMed
6.
go back to reference Luhmann SJ, Lenk LG, Kim YJ et al (2005) Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: is anterior release necessary? Spine 30:2061–2067CrossRefPubMed Luhmann SJ, Lenk LG, Kim YJ et al (2005) Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: is anterior release necessary? Spine 30:2061–2067CrossRefPubMed
7.
go back to reference Rampersaud YRPJ, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190CrossRefPubMed Rampersaud YRPJ, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190CrossRefPubMed
8.
go back to reference Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the toracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the toracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed
9.
go back to reference Guzey FK, Emel E, Hakan Seyithanoglu M et al (2006) Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods. J Spinal Disord Tech 19:436–441CrossRefPubMed Guzey FK, Emel E, Hakan Seyithanoglu M et al (2006) Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods. J Spinal Disord Tech 19:436–441CrossRefPubMed
10.
go back to reference Watanabe K, Yamazaki A, Hirano T et al (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine 35:E1064–E1068CrossRefPubMed Watanabe K, Yamazaki A, Hirano T et al (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine 35:E1064–E1068CrossRefPubMed
11.
go back to reference Ebraheim NA, Tremains M, Xu R et al (2000) Anatomic study of the cervicothoracic spinal nerves and their relation to the pedicles. Am J Orthop 29:779–781PubMed Ebraheim NA, Tremains M, Xu R et al (2000) Anatomic study of the cervicothoracic spinal nerves and their relation to the pedicles. Am J Orthop 29:779–781PubMed
12.
go back to reference Lee CS, Kim MJ, Ahn YJ et al (2007) Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method. J Spinal Disord Tech 20:66–71CrossRefPubMed Lee CS, Kim MJ, Ahn YJ et al (2007) Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method. J Spinal Disord Tech 20:66–71CrossRefPubMed
13.
go back to reference Cha SH, Kim C, Choi BK et al (2007) C-arm assessment of cervical pedicle screw: screw coaxial fluoroscopy and oblique view. Spine 32:1721–1727CrossRefPubMed Cha SH, Kim C, Choi BK et al (2007) C-arm assessment of cervical pedicle screw: screw coaxial fluoroscopy and oblique view. Spine 32:1721–1727CrossRefPubMed
14.
go back to reference Tabaraee E, Gibson AG, Karahalios DG et al (2013) Intraoperative con beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine 38:1953–1958CrossRefPubMed Tabaraee E, Gibson AG, Karahalios DG et al (2013) Intraoperative con beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine 38:1953–1958CrossRefPubMed
15.
go back to reference Shin MH, Hur JW, Ryu KS et al. (2015) Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–E351CrossRefPubMed Shin MH, Hur JW, Ryu KS et al. (2015) Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–E351CrossRefPubMed
16.
go back to reference Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of C1-C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27:E181–E186CrossRefPubMed Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of C1-C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27:E181–E186CrossRefPubMed
17.
go back to reference Hu Y, Yuan ZS, Spiker WR et al (2013) Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. Eur Spine J 22:2770–2776CrossRefPubMedPubMedCentral Hu Y, Yuan ZS, Spiker WR et al (2013) Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. Eur Spine J 22:2770–2776CrossRefPubMedPubMedCentral
18.
go back to reference Ma T, Xu YQ, Cheng YB et al (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72CrossRefPubMed Ma T, Xu YQ, Cheng YB et al (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72CrossRefPubMed
19.
go back to reference Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899CrossRefPubMed Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899CrossRefPubMed
21.
go back to reference Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342CrossRefPubMed Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342CrossRefPubMed
22.
23.
go back to reference Sim E (1993) Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases. Acta Orthop Scand 64:28–32CrossRefPubMed Sim E (1993) Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases. Acta Orthop Scand 64:28–32CrossRefPubMed
24.
go back to reference Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed
25.
go back to reference Karapinar L, Erel N, Ozturk H, Altay T, Kaya A (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21:63–67CrossRefPubMed Karapinar L, Erel N, Ozturk H, Altay T, Kaya A (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21:63–67CrossRefPubMed
26.
go back to reference Modi H, Suh SW, Song HR, Yang JH (2009) Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 33:469–475CrossRefPubMedPubMedCentral Modi H, Suh SW, Song HR, Yang JH (2009) Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 33:469–475CrossRefPubMedPubMedCentral
27.
go back to reference Schizas C, Michel J, Kosmopoulos V, Theumann N (2007) Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613–617CrossRefPubMedPubMedCentral Schizas C, Michel J, Kosmopoulos V, Theumann N (2007) Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613–617CrossRefPubMedPubMedCentral
28.
go back to reference Upendra BN, Meena D, Chowdhury B, Ahmad A, Jayaswal A (2008) Outcome-based classification for assessment of thoracic pedicular screw placement. Spine 33:384–390CrossRefPubMed Upendra BN, Meena D, Chowdhury B, Ahmad A, Jayaswal A (2008) Outcome-based classification for assessment of thoracic pedicular screw placement. Spine 33:384–390CrossRefPubMed
29.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed
30.
go back to reference Fennell VS, Palejwala S, Skoch J et al. (2014) Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: prelimimary clinical experience. J Neurosurg Spine 21:778–784CrossRefPubMed Fennell VS, Palejwala S, Skoch J et al. (2014) Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: prelimimary clinical experience. J Neurosurg Spine 21:778–784CrossRefPubMed
31.
go back to reference Elliott MJ, Slakey JB (2007) Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance. J Pediatr Orthop 27:582–586CrossRefPubMed Elliott MJ, Slakey JB (2007) Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance. J Pediatr Orthop 27:582–586CrossRefPubMed
32.
go back to reference Pesenti S, Bartoli MA, Blondel B et al (2014) Endovascular aortic injury repair after thoracic pedicle screw placement. Orthop Traumatol Surg Res 100:569–573CrossRefPubMed Pesenti S, Bartoli MA, Blondel B et al (2014) Endovascular aortic injury repair after thoracic pedicle screw placement. Orthop Traumatol Surg Res 100:569–573CrossRefPubMed
33.
go back to reference Tong X, Gu P, Yu D et al. (2013) An endovascular treatment of a thoracic aortic injury caused by a misplacement pedicle screw: Case report and review of the literature. J Formos Med Assoc 114:464–468CrossRefPubMed Tong X, Gu P, Yu D et al. (2013) An endovascular treatment of a thoracic aortic injury caused by a misplacement pedicle screw: Case report and review of the literature. J Formos Med Assoc 114:464–468CrossRefPubMed
34.
go back to reference Hansen-Algenstaedt N, Chiu CK, Chan CY, Lee CK, Schaefer C, Kwan MK (2015) Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine (Phila Pa 1976) 40:E954–E963CrossRef Hansen-Algenstaedt N, Chiu CK, Chan CY, Lee CK, Schaefer C, Kwan MK (2015) Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine (Phila Pa 1976) 40:E954–E963CrossRef
35.
go back to reference Lamartina C, Cecchinato R, Fekete Z et al. (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J, Nov; 24 Suppl 7:937–941 Lamartina C, Cecchinato R, Fekete Z et al. (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J, Nov; 24 Suppl 7:937–941
36.
go back to reference Yüksel KZ, Adams MS, Chamberlain RH et al (2007) Pullout resistance of thoracic extrapedicular screws used as a salvage procedure. Spine J 7:286–291CrossRefPubMed Yüksel KZ, Adams MS, Chamberlain RH et al (2007) Pullout resistance of thoracic extrapedicular screws used as a salvage procedure. Spine J 7:286–291CrossRefPubMed
37.
go back to reference Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of atlantoaxial pedicle screws assisted by a drill template. Orthopedics 37:e420–e427CrossRefPubMed Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of atlantoaxial pedicle screws assisted by a drill template. Orthopedics 37:e420–e427CrossRefPubMed
38.
go back to reference Merc M, Drstvensek I, Vogrin M et al (2014) Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine. Chin J Traumatol 17:261–266PubMed Merc M, Drstvensek I, Vogrin M et al (2014) Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine. Chin J Traumatol 17:261–266PubMed
39.
go back to reference Takemoto M, Fujibayashi S, Ota E, et al (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. (Epub ahead of print) Takemoto M, Fujibayashi S, Ota E, et al (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. (Epub ahead of print)
Metadata
Title
A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine
Authors
Yong Hu
Zhen-shan Yuan
William Ryan Spiker
Wei-xin Dong
Xiao-yang Sun
Jian-bing Yuan
Jiao Zhang
Bingke Zhu
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 6/2016
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-016-4540-2

Other articles of this Issue 6/2016

European Spine Journal 6/2016 Go to the issue