Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients

Authors: Xueshi Li, Fuzhi Ai, Hong Xia, Zenghui Wu, Xiangyang Ma, Qingshui Yin

Published in: European Spine Journal | Issue 8/2014

Login to get access

Abstract

Purpose

To investigate the (1) radiographic and clinical accuracy of C1 anterior lateral mass screw (C1ALMS) and C2 anterior pedicle screw (C2APS) placement in the transoral atlantoaxial reduction plate (TARP)-III procedure, (2) screw insertion-associated clinical complications and (3) fusion status between C1 and C2.

Methods

Radiographic and clinical data were obtained from the electronic medical record system. Studies were carried out to assess the accuracy of C1ALMS and C2APS placement, the screw insertion-associated clinical complications and the fusion status between C1 and C2. Placement of the screws was assessed using the modified All India Institute of Medical Sciences outcome-based classification.

Results

Two-hundred and twelve C1ALMS and 207 C2APS in 106 patients were assessed. The ideal accurate rates were 92.0 % (195) and 53.1 % (110), and the acceptable accurate rates were 97.6 % (207) and 87.0 % (180), respectively. One patient died postoperatively due to C2 screw misplacement. There were no symptoms of neurologic and vertebral artery injuries in the rest of the patients. 102 patients (97.1 %) achieved solid fusion between C1 and C2. No instrumentation failure due to delayed union or nonunion was observed.

Conclusion

C1ALMS placement in TARP-III procedures appears to be safe. The cortical breach rate of C2APS is high though clinically the neurovascular complication rate is similar to that of posterior atlantoaxial procedures. Advanced navigation strategies may help improve the accuracy of C2APS placement and decrease potential complications.
Literature
2.
go back to reference Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir (Wien) 151(551–559):560. doi:10.1007/s00701-009-0271-z Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir (Wien) 151(551–559):560. doi:10.​1007/​s00701-009-0271-z
3.
go back to reference Schmelzle R, Harms J, Stoltze D (1987) Osteosynthesen im occipito-cervicalem übergang vom transoralen Zugang aus. XVII SICOT world congress abstracts. Demeter-Verlag, Munich, pp 27–28 Schmelzle R, Harms J, Stoltze D (1987) Osteosynthesen im occipito-cervicalem übergang vom transoralen Zugang aus. XVII SICOT world congress abstracts. Demeter-Verlag, Munich, pp 27–28
4.
5.
go back to reference Wang C, Wang S (2009) Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir 151(5): 551–560; discussion. Acta Neurochir (Wien) 151:1329–1331. doi:10.1007/s00701-009-0477-0 CrossRef Wang C, Wang S (2009) Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir 151(5): 551–560; discussion. Acta Neurochir (Wien) 151:1329–1331. doi:10.​1007/​s00701-009-0477-0 CrossRef
6.
go back to reference Yin Q, Ai F, Zhang K, Chang Y, Xia H, Wu Z, Quan R, Mai X, Liu J (2005) Irreducible anterior atlantoaxial dislocation: one-stage treatment with a transoral atlantoaxial reduction plate fixation and fusion. Report of 5 cases and review of the literature. Spine (Phila Pa 1976) 30:E375–E381CrossRef Yin Q, Ai F, Zhang K, Chang Y, Xia H, Wu Z, Quan R, Mai X, Liu J (2005) Irreducible anterior atlantoaxial dislocation: one-stage treatment with a transoral atlantoaxial reduction plate fixation and fusion. Report of 5 cases and review of the literature. Spine (Phila Pa 1976) 30:E375–E381CrossRef
8.
go back to reference Ai FZ, Yin QS, Xu DC, Xia H, Wu ZH, Mai XH (2011) Transoral atlantoaxial reduction plate internal fixation with transoral transpedicular or articular mass screw of c2 for the treatment of irreducible atlantoaxial dislocation: two case reports. Spine (Phila Pa 1976) 36:E556–E562. doi:10.1097/BRS.0b013e3181f57191 CrossRef Ai FZ, Yin QS, Xu DC, Xia H, Wu ZH, Mai XH (2011) Transoral atlantoaxial reduction plate internal fixation with transoral transpedicular or articular mass screw of c2 for the treatment of irreducible atlantoaxial dislocation: two case reports. Spine (Phila Pa 1976) 36:E556–E562. doi:10.​1097/​BRS.​0b013e3181f57191​ CrossRef
11.
go back to reference Bransford RJ, Russo AJ, Freeborn M, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2011) Posterior C2 instrumentation: accuracy and complications associated with four techniques. Spine (Phila Pa 1976) 36:E936–E943. doi:10.1097/BRS.0b013e3181fdaf06 CrossRef Bransford RJ, Russo AJ, Freeborn M, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2011) Posterior C2 instrumentation: accuracy and complications associated with four techniques. Spine (Phila Pa 1976) 36:E936–E943. doi:10.​1097/​BRS.​0b013e3181fdaf06​ CrossRef
12.
go back to reference Kandziora F, Pflugmacher R, Ludwig K, Duda G, Mittlmeier T, Haas NP (2002) Biomechanical comparison of four anterior atlantoaxial plate systems. J Neurosurg 96:313–320PubMed Kandziora F, Pflugmacher R, Ludwig K, Duda G, Mittlmeier T, Haas NP (2002) Biomechanical comparison of four anterior atlantoaxial plate systems. J Neurosurg 96:313–320PubMed
13.
go back to reference Kandziora F, Schulze-Stahl N, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T (2001) Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg 95:80–87PubMed Kandziora F, Schulze-Stahl N, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T (2001) Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg 95:80–87PubMed
14.
go back to reference Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef
15.
go back to reference Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(1351–1356):1356–1357 Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(1351–1356):1356–1357
18.
go back to reference Aryan HE, Newman CB, Nottmeier EW, Acosta FJ, Wang VY, Ames CP (2008) Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229. doi:10.3171/SPI/2008/8/3/222 PubMedCrossRef Aryan HE, Newman CB, Nottmeier EW, Acosta FJ, Wang VY, Ames CP (2008) Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229. doi:10.​3171/​SPI/​2008/​8/​3/​222 PubMedCrossRef
19.
go back to reference Yeom JS, Buchowski JM, Park KW, Chang BS, Lee CK, Riew KD (2008) Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine (Phila Pa 1976) 33:E942–E949. doi:10.1097/BRS.0b013e3181870441 CrossRef Yeom JS, Buchowski JM, Park KW, Chang BS, Lee CK, Riew KD (2008) Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine (Phila Pa 1976) 33:E942–E949. doi:10.​1097/​BRS.​0b013e3181870441​ CrossRef
20.
go back to reference Parker SL, McGirt MJ, Garces-Ambrossi GL, Mehta VA, Sciubba DM, Witham TF, Gokaslan ZL, Wolinksy JP (2009) Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery 64(343–348):348–349. doi:10.1227/01.NEU.0000338955.36649.4F Parker SL, McGirt MJ, Garces-Ambrossi GL, Mehta VA, Sciubba DM, Witham TF, Gokaslan ZL, Wolinksy JP (2009) Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery 64(343–348):348–349. doi:10.​1227/​01.​NEU.​0000338955.​36649.​4F
21.
go back to reference Sciubba DM, Noggle JC, Vellimana AK, Alosh H, McGirt MJ, Gokaslan ZL, Wolinsky JP (2009) Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws. Clinical article. J Neurosurg Spine 11:15–22. doi:10.3171/2009.3.SPINE08166 PubMedCrossRef Sciubba DM, Noggle JC, Vellimana AK, Alosh H, McGirt MJ, Gokaslan ZL, Wolinsky JP (2009) Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws. Clinical article. J Neurosurg Spine 11:15–22. doi:10.​3171/​2009.​3.​SPINE08166 PubMedCrossRef
22.
go back to reference Wang S, Wang C, Wood KB, Yan M, Zhou H (2011) Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases. Spine (Phila Pa 1976) 36:3–8. doi:10.1097/BRS.0b013e3181c97dc7 Wang S, Wang C, Wood KB, Yan M, Zhou H (2011) Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases. Spine (Phila Pa 1976) 36:3–8. doi:10.​1097/​BRS.​0b013e3181c97dc7​
23.
go back to reference Alosh H, Parker SL, McGirt MJ, Gokaslan ZL, Witham TF, Bydon A, Wolinsky JP, Sciubba DM (2010) Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws. J Spinal Disord Tech 23:9–14. doi:10.1097/BSD.0b013e318194e746 PubMedCrossRef Alosh H, Parker SL, McGirt MJ, Gokaslan ZL, Witham TF, Bydon A, Wolinsky JP, Sciubba DM (2010) Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws. J Spinal Disord Tech 23:9–14. doi:10.​1097/​BSD.​0b013e318194e746​ PubMedCrossRef
24.
25.
go back to reference Fensky F, Kueny RA, Sellenschloh K, Puschel K, Morlock MM, Rueger JM, Lehmann W, Huber G, Hansen-Algenstaedt N (2014) Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study. Eur Spine J 23:724–731. doi:10.1007/s00586-013-3143-4 PubMedCrossRef Fensky F, Kueny RA, Sellenschloh K, Puschel K, Morlock MM, Rueger JM, Lehmann W, Huber G, Hansen-Algenstaedt N (2014) Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study. Eur Spine J 23:724–731. doi:10.​1007/​s00586-013-3143-4 PubMedCrossRef
26.
go back to reference Yin Q, Xia H, Wu Z, Smith WD Transoral atlantoaxial reduction and plate fixation. Saint Louis, Missouri Yin Q, Xia H, Wu Z, Smith WD Transoral atlantoaxial reduction and plate fixation. Saint Louis, Missouri
27.
28.
go back to reference Lesoin F, Autricque A, Franz K, Villette L, Jomin M (1987) Transcervical approach and screw fixation for upper cervical spine pathology. Surg Neurol 27:459–465PubMedCrossRef Lesoin F, Autricque A, Franz K, Villette L, Jomin M (1987) Transcervical approach and screw fixation for upper cervical spine pathology. Surg Neurol 27:459–465PubMedCrossRef
Metadata
Title
Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients
Authors
Xueshi Li
Fuzhi Ai
Hong Xia
Zenghui Wu
Xiangyang Ma
Qingshui Yin
Publication date
01-08-2014
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 8/2014
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-014-3353-4

Other articles of this Issue 8/2014

European Spine Journal 8/2014 Go to the issue