Skip to main content
Top
Published in: European Spine Journal 4/2014

01-07-2014 | Review Article

Use of the Universal Clamp in adolescent idiopathic scoliosis

Authors: Jérôme Sales de Gauzy, Jean-Luc Jouve, Brice Ilharreborde, Benjamin Blondel, Franck Accadbled, Keyvan Mazda

Published in: European Spine Journal | Special Issue 4/2014

Login to get access

Abstract

The Universal Clamp (UC) equipped with a soft sublaminar band is a relatively new thoracic anchor that can be used in hybrid constructs. A dedicated reduction tool that applies traction to the sublaminar band permits gentle translation of the thoracic curve to the pre-contoured fusion rods, which have been previously anchored distally by pedicle screws and proximally by hooks in a claw configuration.

Methods

A literature review concerning the use of UC in adolescent idiopathic Scoliosis was performed.

Results

The results confirm the efficacy with the UC hybrid constructs, the good correction (71−66 %) of the main thoracic curve and low loss of correction at 2-year follow-up (3−4 %). The thoracic curve correction achieved and maintained in the AIS patients appears to be substantially higher than that reported for all hook and hook hybrid techniques. Regardless of the deformity correcting method employed with all-screw constructs, the Cobb angle correction achieved is equivalent to that achieved with UC hybrid devices. Among the present AIS patients who had normal values of thoracic kyphosis pre-operatively, there was almost no change in average thoracic kyphosis at the latest follow-up. However, among the patients with low pre-operative values of T5–T12 kyphosis, the average T5–T12 kyphosis improved.

Conclusion

Hybrid construct with UC is safe, with reduced operative time and blood loss. While achieving deformity correction in the coronal and axial planes equivalent to the best-reported results of all screw or previous hybrid constructs, the UC hybrid technique appears to provide superior correction in the sagittal plane. The excellent outcome is maintained at the 2-year follow-up.
Literature
1.
go back to reference Bernard TN Jr, Johnston CE II, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed Bernard TN Jr, Johnston CE II, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed
2.
go back to reference Cotrel Y, Dubousset J, Guillaumat M (1988) New universal instrumentation in spinal surgery. Clin Orthop Relat Res 227:10–23PubMed Cotrel Y, Dubousset J, Guillaumat M (1988) New universal instrumentation in spinal surgery. Clin Orthop Relat Res 227:10–23PubMed
3.
go back to reference De Gauzy JS, Jouve JL, Accadbled F, Blondel B, Bollini G (2011) Use of the universal clamp in adolescent idiopathic scoliosis for deformity correction and as an adjunct to fusion: 2-year follow-up. J Child Orthop 5:273–282CrossRef De Gauzy JS, Jouve JL, Accadbled F, Blondel B, Bollini G (2011) Use of the universal clamp in adolescent idiopathic scoliosis for deformity correction and as an adjunct to fusion: 2-year follow-up. J Child Orthop 5:273–282CrossRef
4.
go back to reference Gaines RW Jr, Abernathie DL (1986) Mersilene tapes as a substitute for wire in segmental spinal instrumentation for children. Spine (Phila Pa 1976) 11:907–913CrossRef Gaines RW Jr, Abernathie DL (1986) Mersilene tapes as a substitute for wire in segmental spinal instrumentation for children. Spine (Phila Pa 1976) 11:907–913CrossRef
5.
go back to reference Gazzeri R, Faiola A, Galarza M, Tamorri M (2009) Universal clamp system in thoracolumbar spinal fixation: technical note. Acta Neurochir (Wien) 151:1673–1680CrossRef Gazzeri R, Faiola A, Galarza M, Tamorri M (2009) Universal clamp system in thoracolumbar spinal fixation: technical note. Acta Neurochir (Wien) 151:1673–1680CrossRef
6.
go back to reference Grobler LJ, Gaines RW, Kempff PG (1997) Comparing mersilene* tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus). Iowa Orthop J 17:20–31PubMedCentralPubMed Grobler LJ, Gaines RW, Kempff PG (1997) Comparing mersilene* tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus). Iowa Orthop J 17:20–31PubMedCentralPubMed
7.
go back to reference Hongo M, Ilharreborde B, Gay RE, Zhao C, Zhao KD, Berglund LJ, Zobitz M, An KN (2009) Biomechanical evaluation of a new fixation device for the thoracic spine. Eur Spine J 18:1213–1219PubMedCentralPubMedCrossRef Hongo M, Ilharreborde B, Gay RE, Zhao C, Zhao KD, Berglund LJ, Zobitz M, An KN (2009) Biomechanical evaluation of a new fixation device for the thoracic spine. Eur Spine J 18:1213–1219PubMedCentralPubMedCrossRef
8.
go back to reference Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Presedo A, Pennecot GF, Mazda K (2010) Hybrid constructs for tridimensional correction of the thoracic spine in adolescent idiopathic scoliosis: a comparative analysis of universal clamps versus hooks. Spine (Phila Pa 1976) 35:306–314CrossRef Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Presedo A, Pennecot GF, Mazda K (2010) Hybrid constructs for tridimensional correction of the thoracic spine in adolescent idiopathic scoliosis: a comparative analysis of universal clamps versus hooks. Spine (Phila Pa 1976) 35:306–314CrossRef
9.
go back to reference Jouve JL, de Gauzy JS, Blondel B, Launay F, Accadbled F, Bollini G (2010) Use of the universal clamp for deformity correction and as an adjunct to fusion: preliminary results in scoliosis. J Child Orthop 4:73–80PubMedCentralPubMedCrossRef Jouve JL, de Gauzy JS, Blondel B, Launay F, Accadbled F, Bollini G (2010) Use of the universal clamp for deformity correction and as an adjunct to fusion: preliminary results in scoliosis. J Child Orthop 4:73–80PubMedCentralPubMedCrossRef
10.
go back to reference La Rosa G, Giglio G, Oggiano L (2011) Surgical treatment of neurological scoliosis using hybrid construct (lumbar transpedicular screws plus thoracic sublaminar acrylic loops). Eur Spine J 20(Suppl 1):S90–S94PubMedCrossRef La Rosa G, Giglio G, Oggiano L (2011) Surgical treatment of neurological scoliosis using hybrid construct (lumbar transpedicular screws plus thoracic sublaminar acrylic loops). Eur Spine J 20(Suppl 1):S90–S94PubMedCrossRef
11.
go back to reference La Rosa G, Giglio G, Oggiano L (2012) Sagittal profile control in patients affected by neurological scoliosis using universal clamps: a 4-year follow-up study. Eur Spine J 21(Suppl 1):S32–S36PubMedCrossRef La Rosa G, Giglio G, Oggiano L (2012) Sagittal profile control in patients affected by neurological scoliosis using universal clamps: a 4-year follow-up study. Eur Spine J 21(Suppl 1):S32–S36PubMedCrossRef
12.
go back to reference Luque ER (1982) The anatomic basis and development of segmental spinal instrumentation. Spine 7:256–259PubMedCrossRef Luque ER (1982) The anatomic basis and development of segmental spinal instrumentation. Spine 7:256–259PubMedCrossRef
13.
go back to reference Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 163:192–198PubMed Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 163:192–198PubMed
14.
go back to reference Mazda K, Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Pennecot GF (2009) Efficacy and safety of posteromedial translation for correction of thoracic curves in adolescent idiopathic scoliosis using a new connection to the spine: the universal clamp. Eur Spine J 18:158–169PubMedCentralPubMedCrossRef Mazda K, Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Pennecot GF (2009) Efficacy and safety of posteromedial translation for correction of thoracic curves in adolescent idiopathic scoliosis using a new connection to the spine: the universal clamp. Eur Spine J 18:158–169PubMedCentralPubMedCrossRef
15.
go back to reference Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed
16.
go back to reference O’Brien JP, Stephens MM, Prickett CF, Wilcox A, Evans JH (1986) Nylon sublaminar straps in segmental instrumentation for spinal disorders. Clin Orthop Relat Res 203:168–171 O’Brien JP, Stephens MM, Prickett CF, Wilcox A, Evans JH (1986) Nylon sublaminar straps in segmental instrumentation for spinal disorders. Clin Orthop Relat Res 203:168–171
17.
go back to reference Roy-Camille R, Demeuleneare C, Barcat E, Saillant G (1973) Dorsal and lumbar spine osteosynthesis by posterior approach. Nouv Presse Med 2:1309–1312PubMed Roy-Camille R, Demeuleneare C, Barcat E, Saillant G (1973) Dorsal and lumbar spine osteosynthesis by posterior approach. Nouv Presse Med 2:1309–1312PubMed
18.
go back to reference Schrader WC, Bethem D, Scerbin V (1988) The chronic local effects of sublaminar wires. An animal model. Spine (Phila Pa 1976) 13:499–502CrossRef Schrader WC, Bethem D, Scerbin V (1988) The chronic local effects of sublaminar wires. An animal model. Spine (Phila Pa 1976) 13:499–502CrossRef
19.
go back to reference Takahata M, Ito M, Abumi K, Kotani Y, Sudo H, Ohshima S, Minami A (2007) Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis. J Spinal Disord Tech 20:449–455PubMedCrossRef Takahata M, Ito M, Abumi K, Kotani Y, Sudo H, Ohshima S, Minami A (2007) Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis. J Spinal Disord Tech 20:449–455PubMedCrossRef
Metadata
Title
Use of the Universal Clamp in adolescent idiopathic scoliosis
Authors
Jérôme Sales de Gauzy
Jean-Luc Jouve
Brice Ilharreborde
Benjamin Blondel
Franck Accadbled
Keyvan Mazda
Publication date
01-07-2014
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue Special Issue 4/2014
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-014-3341-8

Other articles of this Special Issue 4/2014

European Spine Journal 4/2014 Go to the issue