Skip to main content
Top
Published in: European Spine Journal 8/2009

01-08-2009 | Original Article

Biomechanical evaluation of a new fixation device for the thoracic spine

Authors: Michio Hongo, Brice Ilharreborde, Ralph E. Gay, Chunfeng Zhao, Kristin D. Zhao, Lawrence J. Berglund, Mark Zobitz, Kai-Nan An

Published in: European Spine Journal | Issue 8/2009

Login to get access

Abstract

The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients’ health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5–12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine.
Literature
1.
go back to reference Bernard TN Jr, Johnston CE 2nd, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed Bernard TN Jr, Johnston CE 2nd, Roberts JM, Burke SW (1983) Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases. J Bone Joint Surg Am 65:1339–1345PubMed
5.
go back to reference Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458–1476PubMed Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458–1476PubMed
11.
12.
go back to reference Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44-A:591–610PubMed Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44-A:591–610PubMed
13.
go back to reference Herndon WA, Sullivan JA, Yngve DA, Gross RH, Dreher G (1987) Segmental spinal instrumentation with sublaminar wires. A critical appraisal. J Bone Joint Surg Am 69:851–859PubMed Herndon WA, Sullivan JA, Yngve DA, Gross RH, Dreher G (1987) Segmental spinal instrumentation with sublaminar wires. A critical appraisal. J Bone Joint Surg Am 69:851–859PubMed
14.
go back to reference Ilharreborde B, Mazda K (2007) The universal clamp: a new method of thoracic fixation in the treatment of adolescent idiopathic scoliosis. Eur Musculoskeletal Rev 2:66–68 Ilharreborde B, Mazda K (2007) The universal clamp: a new method of thoracic fixation in the treatment of adolescent idiopathic scoliosis. Eur Musculoskeletal Rev 2:66–68
15.
go back to reference Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating sublaminar segmental spinal instrumentation. J Bone Joint Surg Am 68:556–563PubMed Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating sublaminar segmental spinal instrumentation. J Bone Joint Surg Am 68:556–563PubMed
17.
go back to reference Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
18.
go back to reference Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 19:2–198 Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 19:2–198
19.
go back to reference Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 12:5–141 Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 12:5–141
21.
go back to reference Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed Nicastro JF, Hartjen CA, Traina J, Lancaster JM (1986) Intraspinal pathways taken by sublaminar wires during removal. An experimental study. J Bone Joint Surg Am 68:1206–1209PubMed
24.
go back to reference Reulen HJ, Pfaundler S, Ebeling U (1987) The lateral microsurgical approach to the “extracanalicular” lumbar disc herniation. I: A technical note. Acta Neurochir (Wien) 84:64–67. doi:10.1007/BF01456353 CrossRef Reulen HJ, Pfaundler S, Ebeling U (1987) The lateral microsurgical approach to the “extracanalicular” lumbar disc herniation. I: A technical note. Acta Neurochir (Wien) 84:64–67. doi:10.​1007/​BF01456353 CrossRef
25.
go back to reference Rittmeister M, Leyendecker K, Kurth A, Schmitt E (1999) Cauda equina compression due to a laminar hook: a late complication of posterior instrumentation in scoliosis surgery. Eur Spine J 8:417–420. doi:90080417.586 [pii]PubMedCrossRef Rittmeister M, Leyendecker K, Kurth A, Schmitt E (1999) Cauda equina compression due to a laminar hook: a late complication of posterior instrumentation in scoliosis surgery. Eur Spine J 8:417–420. doi:90080417.​586 [pii]PubMedCrossRef
29.
go back to reference Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL Jr (1984) Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring. J Bone Joint Surg Am 66:1178–1187PubMed Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL Jr (1984) Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring. J Bone Joint Surg Am 66:1178–1187PubMed
Metadata
Title
Biomechanical evaluation of a new fixation device for the thoracic spine
Authors
Michio Hongo
Brice Ilharreborde
Ralph E. Gay
Chunfeng Zhao
Kristin D. Zhao
Lawrence J. Berglund
Mark Zobitz
Kai-Nan An
Publication date
01-08-2009
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2009
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-0999-4

Other articles of this Issue 8/2009

European Spine Journal 8/2009 Go to the issue

Open Operating Theatre (OOT)

Fusion in craniocervical malformation