Skip to main content
Top
Published in: European Spine Journal 8/2007

01-08-2007 | Original Article

Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine

Authors: Shiu-Bii Lien, Nien-Hsien Liou, Shing-Sheng Wu

Published in: European Spine Journal | Issue 8/2007

Login to get access

Abstract

Posterior instrumentation through the pedicle is a common surgery. Understanding the morphometry of the pedicle and the anatomy of adjacent neural structures should help decrease the risk of postoperative complications. T1–L5 segments from 15 sets of human vertebrae were separated into individual vertebrae and the morphometric characteristics of the thoracic and lumbar spine and the safe zone of the pedicle were analyzed. T11–L5 segments from six human cadavers were dissected. Measurements were taken from the pedicle to the dura and nerve roots superiorly, inferiorly, medially, and laterally, and the transverse angles of the nerve roots were measured. Pedicles were widest in L5 and narrowest in T4 in the transverse plane, and widest in T11 or T12 and narrowest in T1 in the sagittal plane. In individual pedicle, the ranges of the safe zone width and height were 3.4–7.7 and 8.6–13.7 mm, respectively, in T1–T10; and 7.2–17.8 and 13.9–16.7 mm, respectively, in T11–L5. The transverse angle of the pedicle decreases progressively from T1 to T12, then increase from L1 to L5. In sagittal angle, the largest angle localized at T2 and the smallest at L5. The mean distances from pedicles to adjacent neural structures were greater superiorly and laterally than inferiorly and medially. The lateral distance between nerve root and the pedicle ranged from 2.4 to 9.6 mm in lumbar spine. This study provides potential safe zones for the application of through-pedicle procedures to help decrease the risk of postoperative complications.
Literature
1.
go back to reference Belkoff SM, Jasper LE, Stevens SS (2002) An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load. Spine 27:1640–1643PubMedCrossRef Belkoff SM, Jasper LE, Stevens SS (2002) An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load. Spine 27:1640–1643PubMedCrossRef
2.
go back to reference Belkoff SM, Mathis JM, Fenton DC, Scribner RM, Reiley ME, Talmadge K (2001) An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture. Spine 26:151–156PubMedCrossRef Belkoff SM, Mathis JM, Fenton DC, Scribner RM, Reiley ME, Talmadge K (2001) An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture. Spine 26:151–156PubMedCrossRef
3.
go back to reference Berry JL, Moran JM, Berg WS, Steffee AD (1987) A morphometric study of human lumbar and selected thoracic vertebrae. Spine 12:362–367PubMedCrossRef Berry JL, Moran JM, Berg WS, Steffee AD (1987) A morphometric study of human lumbar and selected thoracic vertebrae. Spine 12:362–367PubMedCrossRef
4.
go back to reference Boachie-Adjei O, Girardi FP, Bansal M, Rawlins BA (2000) Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 13:496–500PubMedCrossRef Boachie-Adjei O, Girardi FP, Bansal M, Rawlins BA (2000) Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 13:496–500PubMedCrossRef
5.
go back to reference Chen HH, Wang WK,Li KC, Chen TH (2004) Biomechanical effects of the body augmenter for reconstruction of vertebral body. Spine 29:E382–E387PubMedCrossRef Chen HH, Wang WK,Li KC, Chen TH (2004) Biomechanical effects of the body augmenter for reconstruction of vertebral body. Spine 29:E382–E387PubMedCrossRef
6.
go back to reference Cottle W, Budney D, Moreau M, Raso J, Greenhill B (1995) A transpedicularly implanted anterior spinal support. J Spinal Disord 8:479–485PubMedCrossRef Cottle W, Budney D, Moreau M, Raso J, Greenhill B (1995) A transpedicularly implanted anterior spinal support. J Spinal Disord 8:479–485PubMedCrossRef
7.
go back to reference Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1557PubMedCrossRef Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1557PubMedCrossRef
8.
go back to reference Ebraheim NA, Rollins JR, Xu R, Yeasting RA (1996) Projection of the lumbar pedicle and its morphometic analysis. Spine 21:1296–1300PubMedCrossRef Ebraheim NA, Rollins JR, Xu R, Yeasting RA (1996) Projection of the lumbar pedicle and its morphometic analysis. Spine 21:1296–1300PubMedCrossRef
9.
go back to reference Ebraheim NA, Xu R, Ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238PubMedCrossRef Ebraheim NA, Xu R, Ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238PubMedCrossRef
10.
go back to reference Ebraheim NA, Xu R, Darwich M, Yeasting RA (1997) Anatomic relations between the lumbar pedicle and the adjacent neural structures. Spine 22:2338–2341PubMedCrossRef Ebraheim NA, Xu R, Darwich M, Yeasting RA (1997) Anatomic relations between the lumbar pedicle and the adjacent neural structures. Spine 22:2338–2341PubMedCrossRef
11.
go back to reference Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. Spine 18:2231–2239PubMed Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. Spine 18:2231–2239PubMed
12.
go back to reference Galibert P, Deramond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166–168PubMed Galibert P, Deramond H, Rosat P, Le Gars D (1987) Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie 33:166–168PubMed
13.
14.
go back to reference Hou S, Hu R, Shi Y (1993) Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population. Spine 18:1850–1855PubMedCrossRef Hou S, Hu R, Shi Y (1993) Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population. Spine 18:1850–1855PubMedCrossRef
15.
go back to reference Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32PubMedCrossRef Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32PubMedCrossRef
16.
go back to reference Lieberman IH, Dudeney S, Reinhardt MK, Bell G (2001) Initial outcome and efficacy of “kyphoplasty” in the treatment of painful osteoporotic vertebral compression fractures. Spine 26:1631–1638PubMedCrossRef Lieberman IH, Dudeney S, Reinhardt MK, Bell G (2001) Initial outcome and efficacy of “kyphoplasty” in the treatment of painful osteoporotic vertebral compression fractures. Spine 26:1631–1638PubMedCrossRef
17.
go back to reference Lieberman I, Reinhardt MK (2003) Vertebroplasty and kyphoplsty for osteolytic vertebral collapse. Clin Orthop 415S:176–186 Lieberman I, Reinhardt MK (2003) Vertebroplasty and kyphoplsty for osteolytic vertebral collapse. Clin Orthop 415S:176–186
18.
go back to reference Louis R (1978) Topographic relationships of the vertebral column, spinal cord, and nerve roots. Anat Clin 1:3–12CrossRef Louis R (1978) Topographic relationships of the vertebral column, spinal cord, and nerve roots. Anat Clin 1:3–12CrossRef
19.
go back to reference Matsuzaki H, Tokuhashi Y, Matsumoto F, Hoshino M, Kiuchi T, Toriyama S (1990) Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine 15:1159–1165PubMedCrossRef Matsuzaki H, Tokuhashi Y, Matsumoto F, Hoshino M, Kiuchi T, Toriyama S (1990) Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine 15:1159–1165PubMedCrossRef
20.
go back to reference Mirkovic SR, Schwartz DG, Glazier KD (1995) Anatomic considerations in lumbar posterolateral percutaneous procedures. Spine 20:1965–1971PubMed Mirkovic SR, Schwartz DG, Glazier KD (1995) Anatomic considerations in lumbar posterolateral percutaneous procedures. Spine 20:1965–1971PubMed
21.
go back to reference Olsewski JM, Simmons EH, Kallen FC, Mendel FC, Severin CM, Berens DL (1990) Morphometry of the lumbar spine: Anatomical perspectives related to transpedicular fixation. J Bone Joint Surg 72A:541–549 Olsewski JM, Simmons EH, Kallen FC, Mendel FC, Severin CM, Berens DL (1990) Morphometry of the lumbar spine: Anatomical perspectives related to transpedicular fixation. J Bone Joint Surg 72A:541–549
22.
go back to reference Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J, Krag M (1991) Thoracic human vertebrae. Quantitative three-dimensional anatomy. Spine 16:888–901PubMedCrossRef Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J, Krag M (1991) Thoracic human vertebrae. Quantitative three-dimensional anatomy. Spine 16:888–901PubMedCrossRef
23.
go back to reference Phillips FM, Ho E, Campbell-Hupp M, McNally T, Wetzel FT, Gupta P (2003) Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. Spine 28:2260–2267PubMedCrossRef Phillips FM, Ho E, Campbell-Hupp M, McNally T, Wetzel FT, Gupta P (2003) Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. Spine 28:2260–2267PubMedCrossRef
24.
go back to reference Phillips FM (2003) Minimally invasive treatments of osteoporotic vertebral compression fractures. Spine 28:S45–S53PubMedCrossRef Phillips FM (2003) Minimally invasive treatments of osteoporotic vertebral compression fractures. Spine 28:S45–S53PubMedCrossRef
25.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203:7–17PubMed Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203:7–17PubMed
26.
go back to reference Suk S, Lee CK, Kim W, Chung YJ, Park YB (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405PubMedCrossRef Suk S, Lee CK, Kim W, Chung YJ, Park YB (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405PubMedCrossRef
27.
go back to reference Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018PubMedCrossRef Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018PubMedCrossRef
28.
go back to reference West JL, Ogilvie JW, Bradford DS (1991) Complications of the variables screw plate pedicle screw fixation. Spine 16:576–579PubMedCrossRef West JL, Ogilvie JW, Bradford DS (1991) Complications of the variables screw plate pedicle screw fixation. Spine 16:576–579PubMedCrossRef
29.
go back to reference Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMedCrossRef Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMedCrossRef
Metadata
Title
Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine
Authors
Shiu-Bii Lien
Nien-Hsien Liou
Shing-Sheng Wu
Publication date
01-08-2007
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2007
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0245-2

Other articles of this Issue 8/2007

European Spine Journal 8/2007 Go to the issue