Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure

Authors: W. Schmoelz, J. F. Huber, T. Nydegger, L. Claes, H. J. Wilke

Published in: European Spine Journal | Issue 8/2006

Login to get access

Abstract

In recent years, non-fusion implants to stabilise the lumbar spine have become more and more popular. However, little is known on the load bearing of such dynamic stabilisation systems. In order to investigate the load bearing of discs bridged with rigid and dynamic stabilisation systems, six lumbar cadaver spines were mounted in a spine tester and loaded with pure moments in the three main motion planes. Four different states of the specimens were studied: intact, destabilised, stabilisation with a Dynesys® and stabilisation with an internal fixator. Intradiscal pressure (IDP) measurements were used to assess the load bearing of the bridged disc. In the neutral unloaded position, there were small but not significant differences in disc pressure for the four states of the treated disc (P>0.05). Concerning the disc pressure during the course of loading, both the Dynesys® and internal fixator did significantly reduce the pressure change from neutral to extension in comparison to the intact state (−0.05, −0.04 and +0.24 MPa, respectively) (P<0.05). Compared to the intact state, there was no significant pressure change from neutral to flexion (0.14, 0.15 and 0.18 MPa, respectively) (P>0.05). The devices apparently eliminated the pressure change from neutral to lateral bending (Dynesys 0.01 MPa, Fixator 0.01 MPa and intact 0.24 MPa), but due to large variations in the intact and defect states the differences were not significant (P>0.05). In axial rotation, the pressure change for the internal fixator was reduced compared to the intact state; however, the change was only significant in left axial rotation (P<0.05). The Dynesys® showed no significant differences (P>0.05) in axial rotation. No changes in IDP were seen in the adjacent discs for either the Dynesys or the internal fixator. Our results showed that the IDPs for both devices were similar, but altered compared to the intact disc.
Literature
1.
go back to reference Abe E, Nickel T, Buttermann GR, Lewis JL, Transfeldt EE (1998) Lumbar intradiscal pressure after posterolateral fusion and pedicle screw fixation. Tohoku J Exp Med 186(4):243–253PubMedCrossRef Abe E, Nickel T, Buttermann GR, Lewis JL, Transfeldt EE (1998) Lumbar intradiscal pressure after posterolateral fusion and pedicle screw fixation. Tohoku J Exp Med 186(4):243–253PubMedCrossRef
2.
go back to reference Adams MA, McMillan DW, Green TP, Dolan P (1996) Sustained loading generates stress concentrations in lumbar intervertebral discs. Spine 21(4):434–438PubMedCrossRef Adams MA, McMillan DW, Green TP, Dolan P (1996) Sustained loading generates stress concentrations in lumbar intervertebral discs. Spine 21(4):434–438PubMedCrossRef
3.
go back to reference Adams MA, McNally DS, Dolan P (1996) ‘Stress’ distributions inside intervertebral discs. The effects of age and degeneration. J Bone Joint Surg Br 78(6):965–972PubMedCrossRef Adams MA, McNally DS, Dolan P (1996) ‘Stress’ distributions inside intervertebral discs. The effects of age and degeneration. J Bone Joint Surg Br 78(6):965–972PubMedCrossRef
4.
go back to reference Chow DH, Luk KD, Evans JH, Leong JC (1996) Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments. Spine 21(5):549–555PubMedCrossRef Chow DH, Luk KD, Evans JH, Leong JC (1996) Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments. Spine 21(5):549–555PubMedCrossRef
5.
go back to reference Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC (1997) The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: an in vitro biomechanical analysis. Spine 22(22):2655–2663PubMedCrossRef Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC (1997) The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: an in vitro biomechanical analysis. Spine 22(22):2655–2663PubMedCrossRef
6.
go back to reference Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18(15):2231–2238 (discussion 2238–2239) Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18(15):2231–2238 (discussion 2238–2239)
7.
go back to reference Freudiger S, Dubois G, Lorrain M (1999) Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 119(3–4):127–132PubMedCrossRef Freudiger S, Dubois G, Lorrain M (1999) Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 119(3–4):127–132PubMedCrossRef
8.
go back to reference Grevitt MP, Gardner AD, Spilsbury J, Shackleford IM, Baskerville R, Pursell LM et al (1995) The Graf stabilisation system: early results in 50 patients. Eur Spine J 4(3):169–175 (discussion 135) Grevitt MP, Gardner AD, Spilsbury J, Shackleford IM, Baskerville R, Pursell LM et al (1995) The Graf stabilisation system: early results in 50 patients. Eur Spine J 4(3):169–175 (discussion 135)
9.
go back to reference Korge A, Nydegger T, Polard JL, Mayer HM, Husson JL (2002) A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 11(Suppl 2):S149–S153PubMed Korge A, Nydegger T, Polard JL, Mayer HM, Husson JL (2002) A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 11(Suppl 2):S149–S153PubMed
10.
go back to reference Kumar MN, Baklanov A, Chopin D (2001) Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusion. Eur Spine J 10(4):314–319PubMedCrossRef Kumar MN, Baklanov A, Chopin D (2001) Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusion. Eur Spine J 10(4):314–319PubMedCrossRef
11.
go back to reference Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13(3):375–377PubMedCrossRef Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13(3):375–377PubMedCrossRef
12.
go back to reference Lehmann TR, Spratt KF, Tozzi JE, Weinstein JN, Reinarz SJ, el-Khoury GY et al (1987) Long-term follow-up of lower lumbar fusion patients. Spine 12(2):97–104PubMedCrossRef Lehmann TR, Spratt KF, Tozzi JE, Weinstein JN, Reinarz SJ, el-Khoury GY et al (1987) Long-term follow-up of lower lumbar fusion patients. Spine 12(2):97–104PubMedCrossRef
13.
go back to reference Link HD (2002) History, design and biomechanics of the LINK SB Charite artificial disc. Eur Spine J 11(Suppl 2):S98–S105PubMed Link HD (2002) History, design and biomechanics of the LINK SB Charite artificial disc. Eur Spine J 11(Suppl 2):S98–S105PubMed
14.
go back to reference Mayer HM, Wiechert K, Korge A, Qose I (2002) Minimally invasive total disc replacement: surgical technique and preliminary clinical results. Eur Spine J 11(Suppl 2):S124–S130PubMed Mayer HM, Wiechert K, Korge A, Qose I (2002) Minimally invasive total disc replacement: surgical technique and preliminary clinical results. Eur Spine J 11(Suppl 2):S124–S130PubMed
15.
go back to reference McAfee PC, Weiland DJ, Carlow JJ (1991) Survivorship analysis of pedicle spinal instrumentation. Spine 16(Suppl 8):S422–S427PubMed McAfee PC, Weiland DJ, Carlow JJ (1991) Survivorship analysis of pedicle spinal instrumentation. Spine 16(Suppl 8):S422–S427PubMed
16.
go back to reference McNally DS, Adams MA (1992) Internal intervertebral disc mechanics as revealed by stress profilometry. Spine 17(1):66–73PubMedCrossRef McNally DS, Adams MA (1992) Internal intervertebral disc mechanics as revealed by stress profilometry. Spine 17(1):66–73PubMedCrossRef
17.
go back to reference Mimura M, Panjabi MM, Oxland TR, Crisco JJ, Yamamoto I, Vasavada A (1994) Disc degeneration affects the multidirectional flexibility of the lumbar spine. Spine 19(12):1371–1380PubMedCrossRef Mimura M, Panjabi MM, Oxland TR, Crisco JJ, Yamamoto I, Vasavada A (1994) Disc degeneration affects the multidirectional flexibility of the lumbar spine. Spine 19(12):1371–1380PubMedCrossRef
18.
go back to reference Molz FJ, Partin JI, Kirkpatrick JS (2003) The acute effects of posterior fusion instrumentation on kinematics and intradiscal pressure of the human lumbar spine. J Spinal Disord Tech 16(2):171–179PubMed Molz FJ, Partin JI, Kirkpatrick JS (2003) The acute effects of posterior fusion instrumentation on kinematics and intradiscal pressure of the human lumbar spine. J Spinal Disord Tech 16(2):171–179PubMed
19.
go back to reference Nachemson A (1966) The load on lumbar disks in different positions of the body. Clin Orthop 45:107–122PubMed Nachemson A (1966) The load on lumbar disks in different positions of the body. Clin Orthop 45:107–122PubMed
21.
go back to reference Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K (1999) Posterior lumbar interbody fusion: a retrospective study of complications after facet joint excision and pedicle screw fixation in 148 cases. Acta Orthop Scand 70(4):329–334PubMedCrossRef Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K (1999) Posterior lumbar interbody fusion: a retrospective study of complications after facet joint excision and pedicle screw fixation in 148 cases. Acta Orthop Scand 70(4):329–334PubMedCrossRef
22.
go back to reference Penta M, Sandhu A, Fraser RD (1995) Magnetic resonance imaging assessment of disc degeneration 10 years after anterior lumbar interbody fusion. Spine 20(6):743–747PubMedCrossRef Penta M, Sandhu A, Fraser RD (1995) Magnetic resonance imaging assessment of disc degeneration 10 years after anterior lumbar interbody fusion. Spine 20(6):743–747PubMedCrossRef
23.
go back to reference Pollintine P, Przybyla AS, Dolan P, Adams MA (2004) Neural arch load-bearing in old and degenerated spines. J Biomech 37(2):197–204PubMedCrossRef Pollintine P, Przybyla AS, Dolan P, Adams MA (2004) Neural arch load-bearing in old and degenerated spines. J Biomech 37(2):197–204PubMedCrossRef
24.
go back to reference Quint U, Wilke HJ, Loer F, Claes L (1998) Possibilities for static and dynamic stabilization of the spine in lesions of the anterior and posterior ligament complex. Unfallchirurg 101(9):684–690PubMedCrossRef Quint U, Wilke HJ, Loer F, Claes L (1998) Possibilities for static and dynamic stabilization of the spine in lesions of the anterior and posterior ligament complex. Unfallchirurg 101(9):684–690PubMedCrossRef
25.
go back to reference Rohlmann A, Neller S, Bergmann G, Graichen F, Claes L, Wilke HJ (2001) Effect of an internal fixator and a bone graft on intersegmental spinal motion and intradiscal pressure in the adjacent regions. Eur Spine J 10(4):301–308PubMedCrossRef Rohlmann A, Neller S, Bergmann G, Graichen F, Claes L, Wilke HJ (2001) Effect of an internal fixator and a bone graft on intersegmental spinal motion and intradiscal pressure in the adjacent regions. Eur Spine J 10(4):301–308PubMedCrossRef
26.
go back to reference Rohlmann A, Neller S, Claes L, Bergmann G, Wilke HJ (2001) Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine 26(24):E557–E561PubMedCrossRef Rohlmann A, Neller S, Claes L, Bergmann G, Wilke HJ (2001) Influence of a follower load on intradiscal pressure and intersegmental rotation of the lumbar spine. Spine 26(24):E557–E561PubMedCrossRef
27.
go back to reference Sato K, Kikuchi S, Yonezawa T (1999) In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems. Spine 24(23):2468–2474PubMedCrossRef Sato K, Kikuchi S, Yonezawa T (1999) In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems. Spine 24(23):2468–2474PubMedCrossRef
28.
go back to reference Schlegel JD, Smith JA, Schleusener RL (1996) Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21(8):970–981PubMedCrossRef Schlegel JD, Smith JA, Schleusener RL (1996) Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21(8):970–981PubMedCrossRef
29.
go back to reference Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16(4):418–423PubMed Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16(4):418–423PubMed
30.
go back to reference Seitsalo S, Schlenzka D, Poussa M, Osterman K (1997) Disc degeneration in young patients with isthmic spondylolisthesis treated operatively or conservatively: a long-term follow-up. Eur Spine J 6(6):393–397PubMedCrossRef Seitsalo S, Schlenzka D, Poussa M, Osterman K (1997) Disc degeneration in young patients with isthmic spondylolisthesis treated operatively or conservatively: a long-term follow-up. Eur Spine J 6(6):393–397PubMedCrossRef
31.
go back to reference Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed
32.
go back to reference Swanson KE, Lindsey DP, Hsu KY, Zucherman JF, Yerby SA (2003) The effects of an interspinous implant on intervertebral disc pressures. Spine 28(1):26–32PubMedCrossRef Swanson KE, Lindsey DP, Hsu KY, Zucherman JF, Yerby SA (2003) The effects of an interspinous implant on intervertebral disc pressures. Spine 28(1):26–32PubMedCrossRef
33.
go back to reference Trommsdorff U, Zurbruegg D, Schneider W (2004) Biostability of poly(ethylene-terephthalate) cords used in a spinal implant system. In: Seventh World Biomaterials Congress, Sydney, Australia, p 1364 Trommsdorff U, Zurbruegg D, Schneider W (2004) Biostability of poly(ethylene-terephthalate) cords used in a spinal implant system. In: Seventh World Biomaterials Congress, Sydney, Australia, p 1364
34.
go back to reference Trommsdorff U, Zurbruegg D, Stoll TM (2004) In-vivo stability of polycarbonate-urethane with and without contact to an abscess. In: Seventh World Biomaterials Congress, Sydney, Australia, p 337 Trommsdorff U, Zurbruegg D, Stoll TM (2004) In-vivo stability of polycarbonate-urethane with and without contact to an abscess. In: Seventh World Biomaterials Congress, Sydney, Australia, p 337
35.
go back to reference Weinhoffer SL, Guyer RD, Herbert M, Griffith SL (1995) Intradiscal pressure measurements above an instrumented fusion. A cadaveric study. Spine 20(5):526–531 Weinhoffer SL, Guyer RD, Herbert M, Griffith SL (1995) Intradiscal pressure measurements above an instrumented fusion. A cadaveric study. Spine 20(5):526–531
36.
go back to reference Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMedCrossRef Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMedCrossRef
37.
go back to reference Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg 95(Suppl 2):208–214PubMed Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg 95(Suppl 2):208–214PubMed
38.
go back to reference Wilke HJ, Neef P, Caimi M, Hoogland T, Claes LE (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24(8):755–762PubMedCrossRef Wilke HJ, Neef P, Caimi M, Hoogland T, Claes LE (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24(8):755–762PubMedCrossRef
39.
go back to reference Wilke HJ, Rohlmann A, Neller S, Schultheiss M, Bergmann G, Graichen F et al (2001) Is it possible to simulate physiologic loading conditions by applying pure moments? A comparison of in vivo and in vitro load components in an internal fixator. Spine 26(6):636–642PubMedCrossRef Wilke HJ, Rohlmann A, Neller S, Schultheiss M, Bergmann G, Graichen F et al (2001) Is it possible to simulate physiologic loading conditions by applying pure moments? A comparison of in vivo and in vitro load components in an internal fixator. Spine 26(6):636–642PubMedCrossRef
40.
go back to reference Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148–154PubMedCrossRef Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148–154PubMedCrossRef
41.
go back to reference Wilke HJ, Wolf S, Claes LE, Arand M, Wiesend A (1996) Influence of varying muscle forces on lumbar intradiscal pressure: an in vitro study. J Biomech 29(4):549–555PubMedCrossRef Wilke HJ, Wolf S, Claes LE, Arand M, Wiesend A (1996) Influence of varying muscle forces on lumbar intradiscal pressure: an in vitro study. J Biomech 29(4):549–555PubMedCrossRef
Metadata
Title
Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure
Authors
W. Schmoelz
J. F. Huber
T. Nydegger
L. Claes
H. J. Wilke
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2006
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-005-0032-5

Other articles of this Issue 8/2006

European Spine Journal 8/2006 Go to the issue