Skip to main content
Top
Published in: European Spine Journal 6/2004

01-10-2004 | Original Article

Finite helical axes of motion are a useful tool to describe the three-dimensional in vitro kinematics of the intact, injured and stabilised spine

Authors: A. Kettler, F. Marin, G. Sattelmayer, M. Mohr, H. Mannel, L. Dürselen, L. Claes, H. J. Wilke

Published in: European Spine Journal | Issue 6/2004

Login to get access

Abstract

The finite helical-axes method can be used to describe the three-dimensional in vitro kinematics of the spine. However, this method still suffers from large stochastic calculation errors and poorly conceived visualisation techniques. The aim of the present study, therefore, was to improve the currently used finite helical axes description, by use of a less error-prone calculation algorithm and a new visualisation technique, and to apply this improved method to the study of the three-dimensional in vitro kinematics of the spine. Three-dimensional, continuous motion data of spinal motion segments were used to calculate the position and orientation of the finite helical axes (FHAs). The axes were then projected on plane antero-posterior, lateral and axial radiographs in order to depict the relation to the anatomy of each individual specimen. A hinge joint was used to estimate the measurement error of data collection and axes calculation. In an exemplary in vitro experiment, this method was used to demonstrate the ability of a prosthetic disc nucleus to restore the three-dimensional motion pattern of lumbar motion segments. In the validation experiment with the hinge joint, the calculated FHAs were lying within ±2.5 mm of the actual joint axis and were inclined relative to this axis at up to ±1.5°. In the exemplary in vitro experiment, the position and orientation of the FHAs of the intact specimens were subject to large inter-individual differences in all loading directions. Nucleotomy of the lumbar segments caused the axes to spread out, indicating complex coupled motions. The implantation of the prosthetic disc nucleus, for the most part, more than reversed this effect: the axes became oriented almost parallel to each other. The experiments showed that the present improved description of finite helical axes is a valid and useful tool to characterise the three-dimensional in vitro kinematics of the intact, injured and stabilised spine. The main advantage of this new method is the comprehensive visualisation of joint function with respect to the individual anatomy.
Literature
1.
go back to reference Chao EY (1980) Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 13(12):989–1006PubMed Chao EY (1980) Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 13(12):989–1006PubMed
2.
go back to reference Chau T (2001) A review of analytical techniques for gait data. Part 2: neural network and wavelet methods. Gait Posture 13(2):102–120CrossRefPubMed Chau T (2001) A review of analytical techniques for gait data. Part 2: neural network and wavelet methods. Gait Posture 13(2):102–120CrossRefPubMed
3.
go back to reference Cheze L, Fregly BJ, Dimnet J (1998) Determination of joint functional axes from noisy marker data using the finite helical axis. Hum Mov Sci 17:1–15CrossRef Cheze L, Fregly BJ, Dimnet J (1998) Determination of joint functional axes from noisy marker data using the finite helical axis. Hum Mov Sci 17:1–15CrossRef
4.
go back to reference Crawford NR (2002) A sequence of two rotations—50 degrees torso flexion followed by +/-120 degrees of head axial rotation—was monitored using (essentially) goniometers and simultaneously measured by Euler XZY an YZX decompositions of marker data from an electromagnetic system (flock of birds). Clin Biomech (Bristol, Avon) 17(2):166–168; author reply, 169 Crawford NR (2002) A sequence of two rotations—50 degrees torso flexion followed by +/-120 degrees of head axial rotation—was monitored using (essentially) goniometers and simultaneously measured by Euler XZY an YZX decompositions of marker data from an electromagnetic system (flock of birds). Clin Biomech (Bristol, Avon) 17(2):166–168; author reply, 169
5.
go back to reference Cripton PA, Sati M, Orr TE, Bourquin Y, Dumas GA, Nolte LP (2001) Animation of in vitro biomechanical tests. J Biomech 34(8):1091–1096CrossRefPubMed Cripton PA, Sati M, Orr TE, Bourquin Y, Dumas GA, Nolte LP (2001) Animation of in vitro biomechanical tests. J Biomech 34(8):1091–1096CrossRefPubMed
6.
go back to reference Eysel P, Rompe J, Schoenmayr R, Zoellner J (1999) Biomechanical behaviour of a prosthetic lumbar nucleus. Acta Neurochir (Wien) 141(10):1083–1087 Eysel P, Rompe J, Schoenmayr R, Zoellner J (1999) Biomechanical behaviour of a prosthetic lumbar nucleus. Acta Neurochir (Wien) 141(10):1083–1087
7.
go back to reference Goel VK, Winterbottom JM (1991) Experimental investigation of three-dimensional spine kinetics. Determination of optimal placement of markers. Spine 16(8):1000–1002PubMed Goel VK, Winterbottom JM (1991) Experimental investigation of three-dimensional spine kinetics. Determination of optimal placement of markers. Spine 16(8):1000–1002PubMed
8.
go back to reference Grassmann S, Oxland TR, Gerich U, Nolte LP (1998) Constrained testing conditions affect the axial rotation response of lumbar functional spinal units. Spine 23(10):1155–1162CrossRefPubMed Grassmann S, Oxland TR, Gerich U, Nolte LP (1998) Constrained testing conditions affect the axial rotation response of lumbar functional spinal units. Spine 23(10):1155–1162CrossRefPubMed
9.
go back to reference Haher TR, O’Brien M, Felmly WT et al (1992) Instantaneous axis of rotation as a function of the three columns of the spine. Spine [Suppl 6] 17:S149-154 Haher TR, O’Brien M, Felmly WT et al (1992) Instantaneous axis of rotation as a function of the three columns of the spine. Spine [Suppl 6] 17:S149-154
10.
go back to reference Marin F, Mannel H, Claes L, Durselen L (2003) Correction of axis misalignment in the analysis of knee rotations. Hum Mov Sci 22(3):285–296CrossRefPubMed Marin F, Mannel H, Claes L, Durselen L (2003) Correction of axis misalignment in the analysis of knee rotations. Hum Mov Sci 22(3):285–296CrossRefPubMed
11.
go back to reference Nagerl H, Kubein-Meesenburg D, Cotta H, Fanghanel J, Rossow A, Spiering S (1995) [Biomechanical principles in diarthroses and synarthroses. IV: the mechanics of lumbar vertebrae. A pilot study]. Z Orthop Ihre Grenzgeb 133(6):481–491PubMed Nagerl H, Kubein-Meesenburg D, Cotta H, Fanghanel J, Rossow A, Spiering S (1995) [Biomechanical principles in diarthroses and synarthroses. IV: the mechanics of lumbar vertebrae. A pilot study]. Z Orthop Ihre Grenzgeb 133(6):481–491PubMed
12.
go back to reference Osterbauer PJ, Derickson KL, Peles JD, DeBoer KF, Fuhr AW, Winters JM (1992) Three-dimensional head kinematics and clinical outcome of patients with neck injury treated with spinal manipulative therapy: a pilot study. J Manipulative Physiol Ther 15(8):501–511. Erratum in (1992) J Manipulative Physiol Ther 15(9):following table of contents Osterbauer PJ, Derickson KL, Peles JD, DeBoer KF, Fuhr AW, Winters JM (1992) Three-dimensional head kinematics and clinical outcome of patients with neck injury treated with spinal manipulative therapy: a pilot study. J Manipulative Physiol Ther 15(8):501–511. Erratum in (1992) J Manipulative Physiol Ther 15(9):following table of contents
13.
go back to reference Osterbauer PJ, Long K, Ribaudo TA et al (1996) Three-dimensional head kinematics and cervical range of motion in the diagnosis of patients with neck trauma. J Manipulative Physiol Ther 19(4):231–237PubMed Osterbauer PJ, Long K, Ribaudo TA et al (1996) Three-dimensional head kinematics and cervical range of motion in the diagnosis of patients with neck trauma. J Manipulative Physiol Ther 19(4):231–237PubMed
14.
go back to reference Oxland TR, Panjabi MM, Lin RM (1994) Axes of motion of thoracolumbar burst fractures. J Spinal Disord 7(2):130–138PubMed Oxland TR, Panjabi MM, Lin RM (1994) Axes of motion of thoracolumbar burst fractures. J Spinal Disord 7(2):130–138PubMed
15.
go back to reference Panjabi M, White AA 3rd (1971) A mathematical approach for three-dimensional analysis of the mechanics of the spine. J Biomech 4(3):203–211CrossRefPubMed Panjabi M, White AA 3rd (1971) A mathematical approach for three-dimensional analysis of the mechanics of the spine. J Biomech 4(3):203–211CrossRefPubMed
16.
go back to reference Panjabi MM, Krag MH, Goel VK (1981) A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine. J Biomech 14(7):447–460PubMed Panjabi MM, Krag MH, Goel VK (1981) A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine. J Biomech 14(7):447–460PubMed
17.
go back to reference Ramsey DK, Wretenberg PF (1999) Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint. Clin Biomech (Bristol, Avon) 14(9):595–611 Ramsey DK, Wretenberg PF (1999) Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint. Clin Biomech (Bristol, Avon) 14(9):595–611
18.
go back to reference Veldpaus FE, Woltring HJ, Dortmans LJ (1988) A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. J Biomech 21(1):45–54PubMed Veldpaus FE, Woltring HJ, Dortmans LJ (1988) A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. J Biomech 21(1):45–54PubMed
19.
go back to reference White AA, Panjabi MM (1990) Clinical Biomechanics of the Spine, 2nd edn. Lippincott, Philadelphia White AA, Panjabi MM (1990) Clinical Biomechanics of the Spine, 2nd edn. Lippincott, Philadelphia
20.
go back to reference Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMed Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMed
21.
go back to reference Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg [Suppl2] 95:208–214 Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg [Suppl2] 95:208–214
22.
go back to reference Winters JM, Peles JD, Osterbauer PJ, Derickson K, Deboer KF, Fuhr AW (1993) Three-dimensional head axis of rotation during tracking movements. A tool for assessing neck neuromechanical function. Spine 18(9):1178–1185PubMed Winters JM, Peles JD, Osterbauer PJ, Derickson K, Deboer KF, Fuhr AW (1993) Three-dimensional head axis of rotation during tracking movements. A tool for assessing neck neuromechanical function. Spine 18(9):1178–1185PubMed
23.
go back to reference Woltring HJ, Huiskes R, de Lange A, Veldpaus FE (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18(5):379–389CrossRefPubMed Woltring HJ, Huiskes R, de Lange A, Veldpaus FE (1985) Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18(5):379–389CrossRefPubMed
24.
go back to reference Woltring HJ, Long K, Osterbauer PJ, Fuhr AW (1994) Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics. J Biomech 27(12):1415–1432CrossRefPubMed Woltring HJ, Long K, Osterbauer PJ, Fuhr AW (1994) Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics. J Biomech 27(12):1415–1432CrossRefPubMed
25.
go back to reference Wu G, Siegler S, Allard P et al (2002) ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech 35(4):543–548CrossRefPubMed Wu G, Siegler S, Allard P et al (2002) ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech 35(4):543–548CrossRefPubMed
Metadata
Title
Finite helical axes of motion are a useful tool to describe the three-dimensional in vitro kinematics of the intact, injured and stabilised spine
Authors
A. Kettler
F. Marin
G. Sattelmayer
M. Mohr
H. Mannel
L. Dürselen
L. Claes
H. J. Wilke
Publication date
01-10-2004
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 6/2004
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-004-0710-8

Other articles of this Issue 6/2004

European Spine Journal 6/2004 Go to the issue

Announcements

October 2004