Skip to main content
Top
Published in: European Spine Journal 7/2004

01-11-2004 | Original Article

Implant removal for late-developing infection after instrumented posterior spinal fusion for scoliosis: reinstrumentation reduces loss of correction. A retrospective analysis of 45 cases

Authors: Michael Muschik, Wiebke Lück, Dietrich Schlenzka

Published in: European Spine Journal | Issue 7/2004

Login to get access

Abstract

A retrospective follow-up study of patients who, having undergone instrumented posterior spinal fusion for scoliosis, experienced late infection and then underwent either implant removal alone or implant removal and instrumented refusion. We conducted this study to determine whether it is possible to avoid loss of correction by a single-stage implant removal and reinstrumentation procedure. There have been a few reports of late-appearing infections after spinal instrumentation. Implant bulk, metallurgic reactions, and contamination with low-virulence microorganisms have been suggested as possible etiologic factors. The clinical symptoms include pain, swelling, redness, and spontaneous drainage of fluid. Complete instrumentation removal and systemic antibiotics is usually curative. We retrospectively reviewed 45 patients who underwent instrumented posterior spinal fusion for scoliosis and experienced development of late infections and, after a mean of 3 years after the initial procedure, either underwent implant removal alone [n=35, instrumentation removal (HR) group] or additionally underwent reinstrumentation and fusion [n=10, reinstrumentation and fusion (RI&F) group]. Three patients were reinstrumented 1.5 years after instrumentation removal, and seven underwent a one-stage rod removal and reinstrumentation/refusion procedure. Allergic predisposition, protracted postoperative fever, and pseudarthrosis appear to increase the risk of late-developing infection after posterior spinal fusion. All wounds in both groups healed uneventfully. Preoperative radiographic Cobb measurements showed no statistically significant between-group differences. At follow-up, however, outcome was clearly better in the RI&F group: Loss of correction was significantly smaller in reinstrumented patients. Thus, the thoracic Cobb angle was 28±16° (range 0–55°) in the RI&F group versus 42±15° (21–80°) in the HR group, and the lumbar Cobb angle was 22±11° (10–36°) in the RI&F group versus 29±12° (13–54°) in the HR group. The results of our study demonstrate that wound healing is usually uneventful after instrumentation removal for late infection, also when patients undergo instrumented refusion in a one-stage procedure. Reinstrumentation appears to achieve permanent correction of scoliosis.
Literature
1.
go back to reference Buchholz HW, Elson RA, Engelbrecht E, Lodenkämper H, Röttger J, Siegel A (1981) Management of deep infection of total hip replacement. J Bone Joint Surg [Br] 63:342–53 Buchholz HW, Elson RA, Engelbrecht E, Lodenkämper H, Röttger J, Siegel A (1981) Management of deep infection of total hip replacement. J Bone Joint Surg [Br] 63:342–53
2.
go back to reference Buchholz HW, Engelbrecht E, Röttger J, Siegel A (1976) Erkenntnisse nach Wechsel von über 400 infizierten Hüftendoprothesen. Orthop Praxis 12:117–120 Buchholz HW, Engelbrecht E, Röttger J, Siegel A (1976) Erkenntnisse nach Wechsel von über 400 infizierten Hüftendoprothesen. Orthop Praxis 12:117–120
3.
go back to reference Clark CE, Shufflebarger HL (1999) Late-developing infection in instrumented idiopathic scoliosis. Spine 24:1909–1912CrossRefPubMed Clark CE, Shufflebarger HL (1999) Late-developing infection in instrumented idiopathic scoliosis. Spine 24:1909–1912CrossRefPubMed
4.
go back to reference Dubousset J, Shuffleberger H, Wenger D (1994) Late infection with CD instrumentation. Orthop Trans 18:121 Dubousset J, Shuffleberger H, Wenger D (1994) Late infection with CD instrumentation. Orthop Trans 18:121
5.
go back to reference Fischer K (1980) Das Immunsystem—Grundlagen und klinische Bedeutung. In: Feer E, Joppich G, Schulte FJ, eds, Lehrbuch der Kinderheilkunde. Fischer, Stuttgart Fischer K (1980) Das Immunsystem—Grundlagen und klinische Bedeutung. In: Feer E, Joppich G, Schulte FJ, eds, Lehrbuch der Kinderheilkunde. Fischer, Stuttgart
6.
go back to reference Gaine WJ, Andrew SM, Chadwick P, Cooke E, Williamson AJ (2001) Late operative site pain with isola posterior instrumentation requiring implant removal: infection or metal reaction? Spine 26:583–587CrossRefPubMed Gaine WJ, Andrew SM, Chadwick P, Cooke E, Williamson AJ (2001) Late operative site pain with isola posterior instrumentation requiring implant removal: infection or metal reaction? Spine 26:583–587CrossRefPubMed
7.
go back to reference Helenius I, Remes V, Yrjönen T, Ylikoski M, Schlenzka D, Helenius M, Poussa M (2002) Comparison of long-term functional and radiologic outcome after Harrington instrumentation and spondylodesis in adolescent idiopathic scoliosis. Spine 27:176–180CrossRefPubMed Helenius I, Remes V, Yrjönen T, Ylikoski M, Schlenzka D, Helenius M, Poussa M (2002) Comparison of long-term functional and radiologic outcome after Harrington instrumentation and spondylodesis in adolescent idiopathic scoliosis. Spine 27:176–180CrossRefPubMed
8.
go back to reference Lukaniec T, Menartowicz P, Koltowski K (2001) The infections in 667 patients with spinal deformities operated on with CDI. Eur Spine J 10 [Suppl1]:52 Lukaniec T, Menartowicz P, Koltowski K (2001) The infections in 667 patients with spinal deformities operated on with CDI. Eur Spine J 10 [Suppl1]:52
9.
go back to reference Muschik M, Schlenzka D, Kupferschmidt C (1999) Surgical treatment of adolescent idiopathic scoliosis: Segmental correction versus rod rotation. Eur Spine J 8:93–99CrossRefPubMed Muschik M, Schlenzka D, Kupferschmidt C (1999) Surgical treatment of adolescent idiopathic scoliosis: Segmental correction versus rod rotation. Eur Spine J 8:93–99CrossRefPubMed
10.
go back to reference Perdriolle R, Vidal J (1987) Morphology of scoliosis: Three-dimensional evolution. Orthopedics 10:909–915PubMed Perdriolle R, Vidal J (1987) Morphology of scoliosis: Three-dimensional evolution. Orthopedics 10:909–915PubMed
11.
go back to reference Richards BS (1995) Delayed infections following posterior spinal instrumentation for the treatment of idiopathic scoliosis. J Bone Joint Surg [Am] 77:524–529 Richards BS (1995) Delayed infections following posterior spinal instrumentation for the treatment of idiopathic scoliosis. J Bone Joint Surg [Am] 77:524–529
12.
go back to reference Robertson PA, Taylor TK (1993) Late presentation of infection as a complication of Dwyer anterior spinal instrumentation. J Spinal Disord 6:256–259PubMed Robertson PA, Taylor TK (1993) Late presentation of infection as a complication of Dwyer anterior spinal instrumentation. J Spinal Disord 6:256–259PubMed
13.
go back to reference Schlenzka D, Poussa M, Muschik M (1993) Operative treatment of adolescent idiopathic thoracic scoliosis. Harrington-DTT versus Cotrel-Dubousset instrumentation. Clin Orthop 297:155–160PubMed Schlenzka D, Poussa M, Muschik M (1993) Operative treatment of adolescent idiopathic thoracic scoliosis. Harrington-DTT versus Cotrel-Dubousset instrumentation. Clin Orthop 297:155–160PubMed
14.
go back to reference Thomas P, Summer B, Przybilla B (2001) Allergische Reaktionen auf Metallimplantate. Deutsches Ärzteblatt 98:1699–1702 Thomas P, Summer B, Przybilla B (2001) Allergische Reaktionen auf Metallimplantate. Deutsches Ärzteblatt 98:1699–1702
15.
go back to reference Ure KJ, Amstutz HC, Nasser S, Schmalzried TP (1998) Direct-exchange arthroplasty for the treatment of infection after total hip replacement. An average ten-year follow-up. J Bone Joint Surg [Am] 80:961–968 Ure KJ, Amstutz HC, Nasser S, Schmalzried TP (1998) Direct-exchange arthroplasty for the treatment of infection after total hip replacement. An average ten-year follow-up. J Bone Joint Surg [Am] 80:961–968
16.
go back to reference Wimmer C, Gluch H (1998) Aseptic loosening after CD instrumentation in the treatment of scoliosis: a report about eight cases. J Spinal Disord 11:440–443PubMed Wimmer C, Gluch H (1998) Aseptic loosening after CD instrumentation in the treatment of scoliosis: a report about eight cases. J Spinal Disord 11:440–443PubMed
Metadata
Title
Implant removal for late-developing infection after instrumented posterior spinal fusion for scoliosis: reinstrumentation reduces loss of correction. A retrospective analysis of 45 cases
Authors
Michael Muschik
Wiebke Lück
Dietrich Schlenzka
Publication date
01-11-2004
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 7/2004
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-004-0694-4

Other articles of this Issue 7/2004

European Spine Journal 7/2004 Go to the issue

Announcements