Published in: Journal of Anesthesia 2/2014

01-04-2014 | Original Article

Stroke volume-directed administration of hydroxyethyl starch (HES 130/0.4) and Ringer’s acetate in prone position during neurosurgery: a randomized controlled trial

Authors: Ann-Christine Lindroos, Tomohisa Niiya, Tarja Randell, Tomi T. Niemi

Published in: Journal of Anesthesia | Issue 2/2014

Login to get access

Abstract

Purpose

General anesthesia in the prone position is associated with hypotension. We studied stroke volume (SV)-directed administration of hydroxyethyl starch (HES 130 kDa/0.4) and Ringer’s acetate (RAC) in neurosurgical patients operated on in a prone position to determine the volumes required for stable hemodynamics and possible coagulatory effects.

Methods

Thirty elective neurosurgical patients received either HES (n = 15) or RAC (n = 15). Before positioning, SV measured by arterial pressure waveform analysis was maximized by fluid boluses until SV did not increase more than 10 %. SV was maintained by repeated administration of fluid. RAC 3 ml/kg/h was infused in both groups. Thromboelastometry assessed coagulation. Mann–Whitney U test, Wilcoxon signed-rank test, ANOVA on ranks, and a linear mixed model were applied.

Results

Comparable hemodynamics were achieved with the mean cumulative (SD) boluses of HES or RAC 240 (51) or 267 (62) ml (P = 0.207) before positioning, 340 (124) or 453 (160) ml (P = 0.039) 30 min after positioning, and 440 (229) or 653 (368) ml at the end of surgery (P = 0.067). The mean dose of basal RAC infusion was 813 (235) and 868 (354) ml (P = 0.620) in the HES and RAC group, respectively. Formation and maximum strength of the fibrin clot were decreased in the HES group. Intraoperative blood loss was comparable between groups (P = 0.861).

Conclusion

The amount of RAC needed in the prone position was 25 % greater. The cumulative dose of 440 ml HES induced a slight disturbance in fibrin formation and clot strength. We suggest cautious administration of HES during neurosurgery.
Literature
1.
2.
go back to reference Tetzlaff JE, O’Hara JF Jr, Yoon HJ, Schubert A. Heart rate variability and the prone position under general versus spinal anesthesia. J Clin Anesth. 1998;10:656–9.PubMedCrossRef Tetzlaff JE, O’Hara JF Jr, Yoon HJ, Schubert A. Heart rate variability and the prone position under general versus spinal anesthesia. J Clin Anesth. 1998;10:656–9.PubMedCrossRef
3.
go back to reference Edgcombe H, Carter K, Yarrow S. Anaesthesia in the prone position. Br J Anaesth. 2008;100:165–83.PubMedCrossRef Edgcombe H, Carter K, Yarrow S. Anaesthesia in the prone position. Br J Anaesth. 2008;100:165–83.PubMedCrossRef
4.
go back to reference Gan TJ, Soppitt A, Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesíology. 2002;97:820–6.PubMedCrossRef Gan TJ, Soppitt A, Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesíology. 2002;97:820–6.PubMedCrossRef
5.
go back to reference Giglio MT, Marucci M, Testini M, Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth. 2009;103:637–46.PubMedCrossRef Giglio MT, Marucci M, Testini M, Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth. 2009;103:637–46.PubMedCrossRef
6.
go back to reference Hiltebrand LB, Kimberger O, Arnberger M, Brandt S, Kurz A, Sigurdsson GH. Crystalloids versus colloids for goal-directed fluid therapy in major surgery. Crit Care. 2009;13:R40.PubMedCentralPubMedCrossRef Hiltebrand LB, Kimberger O, Arnberger M, Brandt S, Kurz A, Sigurdsson GH. Crystalloids versus colloids for goal-directed fluid therapy in major surgery. Crit Care. 2009;13:R40.PubMedCentralPubMedCrossRef
7.
go back to reference Kozek-Langenecker SA. Effects of hydroxyethyl starch solutions on hemostasis. Anesthesiology. 2005;103:654–60.PubMedCrossRef Kozek-Langenecker SA. Effects of hydroxyethyl starch solutions on hemostasis. Anesthesiology. 2005;103:654–60.PubMedCrossRef
8.
go back to reference Palmer JD, Sparrow OC, Iannotti F. Postoperative hematoma: a 5-year survey and identification of avoidable risk factors. Neurosurgery. 1994;35:1061–4.PubMedCrossRef Palmer JD, Sparrow OC, Iannotti F. Postoperative hematoma: a 5-year survey and identification of avoidable risk factors. Neurosurgery. 1994;35:1061–4.PubMedCrossRef
9.
go back to reference Niemi TT, Suojaranta-Ylinen RT, Kukkonen SI, Kuitunen AH. Gelatin and hydroxyethyl starch, but not albumin, impair hemostasis after cardiac surgery. Anesth Analg. 2006;102:998–1006.PubMedCrossRef Niemi TT, Suojaranta-Ylinen RT, Kukkonen SI, Kuitunen AH. Gelatin and hydroxyethyl starch, but not albumin, impair hemostasis after cardiac surgery. Anesth Analg. 2006;102:998–1006.PubMedCrossRef
10.
go back to reference Hatada T, Kusunoki M, Sakiyama T, Sakanoue Y, Yamamura T, Okutani R, Kono K, Ishida H, Utsunomiya J. Hemodynamics in the prone jackknife position during surgery. Am J Surg. 1991;162:55–8.PubMedCrossRef Hatada T, Kusunoki M, Sakiyama T, Sakanoue Y, Yamamura T, Okutani R, Kono K, Ishida H, Utsunomiya J. Hemodynamics in the prone jackknife position during surgery. Am J Surg. 1991;162:55–8.PubMedCrossRef
11.
go back to reference Lee TC, Yang LC, Chen HJ. Effect of patient position and hypotensive anesthesia on inferior vena caval pressure. Spine. 1998;23:941–7.PubMedCrossRef Lee TC, Yang LC, Chen HJ. Effect of patient position and hypotensive anesthesia on inferior vena caval pressure. Spine. 1998;23:941–7.PubMedCrossRef
12.
go back to reference Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.PubMedCrossRef Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.PubMedCrossRef
13.
go back to reference Dharmavaram S, Jellish WS, Nockels RP, Shea J, Mehmood R, Ghanayem A, Kleinman B, Jacobs W. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine. 2006;31:1388–93.PubMedCrossRef Dharmavaram S, Jellish WS, Nockels RP, Shea J, Mehmood R, Ghanayem A, Kleinman B, Jacobs W. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine. 2006;31:1388–93.PubMedCrossRef
14.
go back to reference Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.PubMedCrossRef
15.
go back to reference Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after preoperative overnight fasting. Acta Anesthesiol Scand. 2008;52:522–9.CrossRef Jacob M, Chappell D, Conzen P, Finsterer U, Rehm M. Blood volume is normal after preoperative overnight fasting. Acta Anesthesiol Scand. 2008;52:522–9.CrossRef
16.
go back to reference Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.PubMedCrossRef Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.PubMedCrossRef
17.
go back to reference Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care. 2008;12:R82.PubMedCentralPubMedCrossRef Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care. 2008;12:R82.PubMedCentralPubMedCrossRef
18.
go back to reference Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hénaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hénaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef
19.
go back to reference Biais M, Nouette-Gaulain K, Roullet S, Quinart A, Revel P, Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography. Anesth Analg. 2009;109:466–9.PubMedCrossRef Biais M, Nouette-Gaulain K, Roullet S, Quinart A, Revel P, Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography. Anesth Analg. 2009;109:466–9.PubMedCrossRef
20.
go back to reference Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMedCrossRef Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMedCrossRef
21.
go back to reference Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92:984–9.PubMedCrossRef Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg. 2001;92:984–9.PubMedCrossRef
22.
go back to reference Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef Deflandre E, Bonhomme V, Hans P. Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery. Br J Anaesth. 2008;100:245–50.PubMedCrossRef
23.
go back to reference Dawidson IJ, Willms CD, Sandor ZF, Coorpender LL, Reisch JS, Fry WJ. Ringer’s lactate with or without 3% dextran-60 as volume expanders during abdominal aortic surgery. Crit Care Med. 1991;19:36–42.PubMedCrossRef Dawidson IJ, Willms CD, Sandor ZF, Coorpender LL, Reisch JS, Fry WJ. Ringer’s lactate with or without 3% dextran-60 as volume expanders during abdominal aortic surgery. Crit Care Med. 1991;19:36–42.PubMedCrossRef
24.
go back to reference Prien T, Backhaus N, Pelster F, Pircher W, Bünte H, Lawin P. Effect of intraoperative fluid administration and colloid osmotic pressure on the formation of intestinal edema during gastrointestinal surgery. J Clin Anesth. 1990;2:317–23.PubMedCrossRef Prien T, Backhaus N, Pelster F, Pircher W, Bünte H, Lawin P. Effect of intraoperative fluid administration and colloid osmotic pressure on the formation of intestinal edema during gastrointestinal surgery. J Clin Anesth. 1990;2:317–23.PubMedCrossRef
25.
go back to reference Tommasino C, Picozzi V. Volume and electrolyte management. Best Pract Res Clin Anaesthesiol. 2007;21:497–516.PubMedCrossRef Tommasino C, Picozzi V. Volume and electrolyte management. Best Pract Res Clin Anaesthesiol. 2007;21:497–516.PubMedCrossRef
26.
go back to reference Drummond JC, Patel PM, Cole DJ, Kelly PJ. The effect of the reduction of colloid oncotic pressure, with and without reduction of osmolality, on post-traumatic cerebral edema. Anesthesiology. 1998;88:993–1002.PubMedCrossRef Drummond JC, Patel PM, Cole DJ, Kelly PJ. The effect of the reduction of colloid oncotic pressure, with and without reduction of osmolality, on post-traumatic cerebral edema. Anesthesiology. 1998;88:993–1002.PubMedCrossRef
27.
go back to reference Dunker S, Hsu HY, Sebag J, Sadun AA. Perioperative risk factors for posterior ischemic optic neuropathy. J Am Coll Surg. 2002;194:705–10.PubMedCrossRef Dunker S, Hsu HY, Sebag J, Sadun AA. Perioperative risk factors for posterior ischemic optic neuropathy. J Am Coll Surg. 2002;194:705–10.PubMedCrossRef
28.
go back to reference Choi PT, Yip G, Quinonez LG, Cook DJ. Crystalloids vs. colloids in fluid resuscitation: a systematic review. Crit Care Med. 1999;27:200–10.PubMedCrossRef Choi PT, Yip G, Quinonez LG, Cook DJ. Crystalloids vs. colloids in fluid resuscitation: a systematic review. Crit Care Med. 1999;27:200–10.PubMedCrossRef
29.
go back to reference Schierhout G, Roberts I. Fluid resuscitation with colloid or crystalloid solutions in critically ill patients: a systematic review of randomised trials. BMJ. 1998;316:961–4.PubMedCentralPubMedCrossRef Schierhout G, Roberts I. Fluid resuscitation with colloid or crystalloid solutions in critically ill patients: a systematic review of randomised trials. BMJ. 1998;316:961–4.PubMedCentralPubMedCrossRef
30.
go back to reference Velanovich V. Crystalloid versus colloid fluid resuscitation: a meta-analysis of mortality. Surgery (St. Louis). 1989;105:65–71. Velanovich V. Crystalloid versus colloid fluid resuscitation: a meta-analysis of mortality. Surgery (St. Louis). 1989;105:65–71.
31.
go back to reference Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB. Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006;32:1030–8.PubMedCrossRef Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB. Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006;32:1030–8.PubMedCrossRef
32.
go back to reference Hartog CS, Bauer MB, Reinhart K. The efficacy and safety of colloid resuscitation in the critically ill. Anesth Analg. 2011;112:156–64.PubMedCrossRef Hartog CS, Bauer MB, Reinhart K. The efficacy and safety of colloid resuscitation in the critically ill. Anesth Analg. 2011;112:156–64.PubMedCrossRef
33.
go back to reference Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Raivio PM, Kukkonen SI, Niemi TT. Comparison of the effect of 6% hydroxyethyl starch and gelatine on cardiac and stroke volume index: a randomized, controlled trial after cardiac surgery. Perfusion. 2010;25:283–91.PubMedCrossRef Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Raivio PM, Kukkonen SI, Niemi TT. Comparison of the effect of 6% hydroxyethyl starch and gelatine on cardiac and stroke volume index: a randomized, controlled trial after cardiac surgery. Perfusion. 2010;25:283–91.PubMedCrossRef
34.
go back to reference Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.PubMedCrossRef Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg. 1995;130:423–9.PubMedCrossRef
35.
go back to reference Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture; randomised controlled trial. BMJ. 1997;315:909–12.PubMedCentralPubMedCrossRef Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture; randomised controlled trial. BMJ. 1997;315:909–12.PubMedCentralPubMedCrossRef
36.
go back to reference Jungner M, Grände PO, Mattiasson G, Bentzer P. Effects on brain edema of crystalloid and albumin fluid resuscitation after brain trauma and hemorrhage in the rat. Anesthesiology. 2010;112:1194–203.PubMedCrossRef Jungner M, Grände PO, Mattiasson G, Bentzer P. Effects on brain edema of crystalloid and albumin fluid resuscitation after brain trauma and hemorrhage in the rat. Anesthesiology. 2010;112:1194–203.PubMedCrossRef
37.
go back to reference Rusa R, Zornov MH. Fluid management during craniotomy. In: Cottrell JE, Young WL, editors. Cottrell and Young’s neuroanesthesia. 5th ed. Philadelphia: Mosby Elsevier; 2010. p. 155. Rusa R, Zornov MH. Fluid management during craniotomy. In: Cottrell JE, Young WL, editors. Cottrell and Young’s neuroanesthesia. 5th ed. Philadelphia: Mosby Elsevier; 2010. p. 155.
38.
go back to reference Hartog CS, Reuter D, Loesche W, Hofmann M, Reinhart K. Influence of hydroxyethyl starch (HES) 130/0.4 on hemostasis as measured by viscoelastic device analysis: a systematic review. Intensive Care Med. 2011;37:1725–37.PubMedCrossRef Hartog CS, Reuter D, Loesche W, Hofmann M, Reinhart K. Influence of hydroxyethyl starch (HES) 130/0.4 on hemostasis as measured by viscoelastic device analysis: a systematic review. Intensive Care Med. 2011;37:1725–37.PubMedCrossRef
39.
go back to reference Neff TA, Doelberg M, Jungheinrich C, Sauerland A, Spahn DR, Stocker R. Repetitive large-dose infusion of the novel hydroxyethyl starch 130/0.4 in patients with severe head injury. Anesth Analg. 2003;96:1453–9.PubMedCrossRef Neff TA, Doelberg M, Jungheinrich C, Sauerland A, Spahn DR, Stocker R. Repetitive large-dose infusion of the novel hydroxyethyl starch 130/0.4 in patients with severe head injury. Anesth Analg. 2003;96:1453–9.PubMedCrossRef
40.
go back to reference Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Kukkonen SI, Nimei TT. Rapidly degradable hydroxyethyl starch solutions impair blood coagulation after cardiac surgery: a prospective randomized trial. Anesth Analg. 2009;108:30–6.PubMedCrossRef Schramko AA, Suojaranta-Ylinen RT, Kuitunen AH, Kukkonen SI, Nimei TT. Rapidly degradable hydroxyethyl starch solutions impair blood coagulation after cardiac surgery: a prospective randomized trial. Anesth Analg. 2009;108:30–6.PubMedCrossRef
41.
go back to reference Sudheer PS, Logan SW, Ateleanu B, Hall JE. Haemodynamic effects of the prone position: a comparison of propofol total intravenous and inhalation anaesthesia. Anaesthesia. 2006;61:138–41.PubMedCrossRef Sudheer PS, Logan SW, Ateleanu B, Hall JE. Haemodynamic effects of the prone position: a comparison of propofol total intravenous and inhalation anaesthesia. Anaesthesia. 2006;61:138–41.PubMedCrossRef
Metadata
Title
Stroke volume-directed administration of hydroxyethyl starch (HES 130/0.4) and Ringer’s acetate in prone position during neurosurgery: a randomized controlled trial
Authors
Ann-Christine Lindroos
Tomohisa Niiya
Tarja Randell
Tomi T. Niemi
Publication date
01-04-2014
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 2/2014
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-013-1711-8

Other articles of this Issue 2/2014

Journal of Anesthesia 2/2014 Go to the issue