Abstract

The purpose of this study was to validate serum creatinine (SCr) concentrations assayed in the Central Biochemistry Laboratory of the National Institutes of Health (NIH)-funded Chronic Kidney Disease in Children (CKiD) study utilizing an enzymatic assay (Siemens Advia 2400) against a method traceable to reference isotope dilution mass spectroscopy (IDMS) developed by the National Institute of Standards and Technology (NIST). High-performance liquid chromatography (HPLC) measured SCr after external validation utilizing IDMS-based standard reference materials. Sera from the first 201 subjects enrolled in CKiD were analyzed and compared for creatinine concentration by enzymatic and HPLC methods. Fifty “normal” pediatric sera were subsequently analyzed. Finally, a “pediatric” reference standard was prepared and examined for accuracy and precision. Enzymatic SCr concentrations (median 1.4 mg/dl) of CKiD subjects were well correlated with HPLC (r = 0.984) but were slightly higher (+7%; p < 0.001). Agreement was poorer at lower SCr (median 0.4 mg/dl) when using samples from normal children and the “pediatric” reference standard. However, the Roche enzymatic assay was comparable with HPLC in accuracy and precision. Referring physicians should be aware of the accuracy and reproducibility of their laboratory’s SCr assay. Our enzymatic assay agreed well with HPLC in CKiD subjects with elevated SCr. We suggest that NIST develop a pediatric SCr standard reference material for use by assay manufacturers to improve accuracy and precision of assays at the low SCr levels observed in most pediatric patients.
Literature
1.
go back to reference Schwartz GJ, Brion LP, Spitzer A (1987) The use of plasma creatinine concentration for estimating glomerular filtration rate in infants, children, and adolescents. Pediatr Clin North Am 34:571–590CrossRef Schwartz GJ, Brion LP, Spitzer A (1987) The use of plasma creatinine concentration for estimating glomerular filtration rate in infants, children, and adolescents. Pediatr Clin North Am 34:571–590CrossRef
2.
go back to reference Hogg RJ, Furth S, Lemley KV, Portman R, Schwartz GJ, Coresh J, Balk E, Lau J, Levin A, Kausz AT, Eknoyan G, Levey AS (2003) National Kidney Foundation’s kidney disease outcomes quality initiative clinical practice guidelines for chronic kidney disease in children and adolescents: evaluation, classification, and stratification. Pediatrics 111:1416–1421CrossRef Hogg RJ, Furth S, Lemley KV, Portman R, Schwartz GJ, Coresh J, Balk E, Lau J, Levin A, Kausz AT, Eknoyan G, Levey AS (2003) National Kidney Foundation’s kidney disease outcomes quality initiative clinical practice guidelines for chronic kidney disease in children and adolescents: evaluation, classification, and stratification. Pediatrics 111:1416–1421CrossRef
3.
go back to reference Myers GL, Miller WG, Coresh J, Fleming J, Greenberg N, Greene T, Hostetter T, Levey AS, Panteghini M, Welch M, Eckfeldt JH (2006) Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem 52:5–18CrossRef Myers GL, Miller WG, Coresh J, Fleming J, Greenberg N, Greene T, Hostetter T, Levey AS, Panteghini M, Welch M, Eckfeldt JH (2006) Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem 52:5–18CrossRef
4.
go back to reference Levey AS, Bosch JP, Lewis JB, Greene T, Rogers NL, Roth D (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 130:461–470CrossRef Levey AS, Bosch JP, Lewis JB, Greene T, Rogers NL, Roth D (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 130:461–470CrossRef
5.
go back to reference Schwartz GJ, Haycock GB, Chir B, Spitzer A (1976) Plasma creatinine and urea concentration in children: normal values for age and sex. J Pediatr 88:828–830CrossRef Schwartz GJ, Haycock GB, Chir B, Spitzer A (1976) Plasma creatinine and urea concentration in children: normal values for age and sex. J Pediatr 88:828–830CrossRef
6.
go back to reference Keppler A, Gretz N, Schmidt R, Kloetzer HM, Groene HJ, Lelongt B, Meyer M, Sadick M, Pill J (2007) Plasma creatinine determination in mice and rats: an enzymatic method compares favorably with a high-performance liquid chromatography assay. Kidney Int 71:74–78CrossRef Keppler A, Gretz N, Schmidt R, Kloetzer HM, Groene HJ, Lelongt B, Meyer M, Sadick M, Pill J (2007) Plasma creatinine determination in mice and rats: an enzymatic method compares favorably with a high-performance liquid chromatography assay. Kidney Int 71:74–78CrossRef
7.
go back to reference Ambrose RT, Ketchum DF, Smith JW (1983) Creatinine determined by “high-performance” liquid chromatography. Clin Chem 29:256–259PubMed Ambrose RT, Ketchum DF, Smith JW (1983) Creatinine determined by “high-performance” liquid chromatography. Clin Chem 29:256–259PubMed
8.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRef
9.
go back to reference Huang YC, Chiou WL (1983) Creatinine XII: comparison of assays of low serum creatinine levels using high-performance liquid chromatography and two picrate methods. J Pharm Sci 72:836–837CrossRef Huang YC, Chiou WL (1983) Creatinine XII: comparison of assays of low serum creatinine levels using high-performance liquid chromatography and two picrate methods. J Pharm Sci 72:836–837CrossRef
10.
go back to reference Miller WG, Myers GL, Rej R (2006) Why commutability matters. Clin Chem 52:553–554CrossRef Miller WG, Myers GL, Rej R (2006) Why commutability matters. Clin Chem 52:553–554CrossRef
Metadata
Title
Validation of creatinine assays utilizing HPLC and IDMS traceable standards in sera of children
Authors
George J. Schwartz
Tai Kwong
Brian Erway
Bradley Warady
Lori Sokoll
Stanley Hellerstein
Vikas Dharnidharka
Susan Furth
Alvaro Muñoz
Publication date
01-01-2009
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Nephrology / Issue 1/2009
Print ISSN: 0931-041X
Electronic ISSN: 1432-198X
DOI
https://doi.org/10.1007/s00467-008-0957-0

Other articles of this Issue 1/2009

Pediatric Nephrology 1/2009 Go to the issue