Skip to main content
Top
Published in: Surgical Endoscopy 7/2012

01-07-2012

Use of mesh for hiatal hernia repair: a survey of SAGES members

Authors: Jason M. Pfluke, Michael Parker, Steven P. Bowers, Horacio J. Asbun, C. Daniel Smith

Published in: Surgical Endoscopy | Issue 7/2012

Login to get access

Abstract

Background

Mesh use during hiatal hernia repair (HHR) has been suggested to be safe and effective. Concern has been raised about the risk of mesh-related complications, and the higher risk of complications if revisional hiatal surgery is undertaken after mesh has been used. Available data have not established a clear role for mesh in HHR. To assess surgeons’ adoption of the use of mesh for HHR, SAGES members were surveyed regarding their practice related to mesh use for HHR.

Methods

Between April and September 2010, an internet-based survey tool was used to survey SAGES members. Potential participants were contacted via e-mail and invited to complete the survey. Of the 5,323 attempted contacts, 5,024 reached active e-mail accounts. From these, 2,518 members responded (50% response rate).

Results

The majority of respondents currently perform HHR (69%), but only 18% perform more than 20 per year. Of those who perform HHR, 94% use a laparoscopic approach for the majority of repairs. Whereas 25% of surgeons use mesh for the majority of repairs, 23% of surgeons never use mesh. When mesh is used, an absorbable mesh is most commonly used (67%). An onlay technique is used by 93% of respondents. Only 7% of surgeons who have been in practice more than 20 years use mesh compared with 59% of surgeons in practice less than 10 years. Fifty-seven percent of surgeons have never performed revisional foregut surgery on a patient with prior mesh.

Conclusions

Although the majority of surgeons have used mesh for HHR, it is the minority who use it routinely, with younger surgeons more likely to use mesh than older surgeons. Absorbable mesh is most commonly used. When mesh is used, an onlay technique is most commonly used. There is no clear accepted use of mesh in hiatal hernia repair.
Literature
1.
go back to reference Curci JA, Melman LM, Thompson RW, Soper NJ, Matthews BD (2008) Elastic fiber depletion in the supporting ligaments of the gastroesophageal junction: a structural basis for the development of hiatal hernia. J Am Coll Surg 207:191–196PubMedCrossRef Curci JA, Melman LM, Thompson RW, Soper NJ, Matthews BD (2008) Elastic fiber depletion in the supporting ligaments of the gastroesophageal junction: a structural basis for the development of hiatal hernia. J Am Coll Surg 207:191–196PubMedCrossRef
2.
go back to reference Mattar SG, Bowers SP, Galloway KD, Hunter JG, Smith CD (2002) Long-term outcome of laparoscopic repair of paraesophageal hernia. Surg Endosc 16:745–749PubMedCrossRef Mattar SG, Bowers SP, Galloway KD, Hunter JG, Smith CD (2002) Long-term outcome of laparoscopic repair of paraesophageal hernia. Surg Endosc 16:745–749PubMedCrossRef
3.
go back to reference Hashemi M, Peters JH, DeMeester TR, Huprich JE, Quek M, Hagen JA, Crookes PF, Theisen J, DeMeester SR, Sillin LF, Bremner CG (2000) Laparoscopic repair of large type III hiatal hernia: objective followup reveals high recurrence rate. J Am Coll Surg 190:553–560PubMedCrossRef Hashemi M, Peters JH, DeMeester TR, Huprich JE, Quek M, Hagen JA, Crookes PF, Theisen J, DeMeester SR, Sillin LF, Bremner CG (2000) Laparoscopic repair of large type III hiatal hernia: objective followup reveals high recurrence rate. J Am Coll Surg 190:553–560PubMedCrossRef
4.
go back to reference Granderath FA, Granderath UM, Pointner R (2008) Laparoscopic revisional fundoplication with circular hiatal mesh prosthesis: the long-term results. World J Surg 32:999–1007PubMedCrossRef Granderath FA, Granderath UM, Pointner R (2008) Laparoscopic revisional fundoplication with circular hiatal mesh prosthesis: the long-term results. World J Surg 32:999–1007PubMedCrossRef
5.
go back to reference Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48PubMedCrossRef Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48PubMedCrossRef
6.
go back to reference Lee YK, James E, Bochkarev V, Vitamvas M, Oleynikov D (2008) Long-term outcomes of cruroplasty reinforcement with human acellular dermal matrix in large paraesophageal hiatal hernia. J Gastrointest Surg 12:811–815PubMedCrossRef Lee YK, James E, Bochkarev V, Vitamvas M, Oleynikov D (2008) Long-term outcomes of cruroplasty reinforcement with human acellular dermal matrix in large paraesophageal hiatal hernia. J Gastrointest Surg 12:811–815PubMedCrossRef
7.
go back to reference Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed
8.
go back to reference Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2008) Complications of PTFE mesh erosion at the diaphragmatic hiatus. J Gastrointest Surg 12:953–957PubMedCrossRef Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2008) Complications of PTFE mesh erosion at the diaphragmatic hiatus. J Gastrointest Surg 12:953–957PubMedCrossRef
9.
go back to reference Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ, Brunt LM, Hunter JG, Demeester TR, Swanstrom LL, Smith CD, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ, Brunt LM, Hunter JG, Demeester TR, Swanstrom LL, Smith CD, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef
10.
go back to reference Parker M, Bowers SP, Bray JM, Harris AS, Belli EV, Pfluke JM, Preissler S, Asbun HJ, Smith CD (2010) Hiatal mesh is associated with major resection at revisional operation. Surg Endosc 24:3095–3101PubMedCrossRef Parker M, Bowers SP, Bray JM, Harris AS, Belli EV, Pfluke JM, Preissler S, Asbun HJ, Smith CD (2010) Hiatal mesh is associated with major resection at revisional operation. Surg Endosc 24:3095–3101PubMedCrossRef
11.
go back to reference Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42:252–256PubMedCrossRef Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42:252–256PubMedCrossRef
12.
go back to reference Herqueta-Delgado P, Marin-Moreno M, Morales-Conde S, Reina-Serrano S, Jurado-Castillo C, Pellicer-Bautista F, Herrerias-Gutierrez JM (2006) Transmural migration of a prosthetic mesh after surgery of a paraesophageal hernia. Gastrointest Endosc 64:120–121CrossRef Herqueta-Delgado P, Marin-Moreno M, Morales-Conde S, Reina-Serrano S, Jurado-Castillo C, Pellicer-Bautista F, Herrerias-Gutierrez JM (2006) Transmural migration of a prosthetic mesh after surgery of a paraesophageal hernia. Gastrointest Endosc 64:120–121CrossRef
13.
go back to reference Hazebroek EJ, Liebman S, Smith GS (2009) Erosion of a composite PTFE/ePTFE mesh after hiatal hernia surgery. Surg Laparosc Endosc Percutan Tech 19:175–177PubMedCrossRef Hazebroek EJ, Liebman S, Smith GS (2009) Erosion of a composite PTFE/ePTFE mesh after hiatal hernia surgery. Surg Laparosc Endosc Percutan Tech 19:175–177PubMedCrossRef
14.
go back to reference Kepenekci I, Turkcapar AG (2009) Mesh erosion as a complication of laparoscopic fundoplication with prosthetic hiatal closure: report of a case. Surg Laparosc Endosc Percut Tech 10:e51–e54CrossRef Kepenekci I, Turkcapar AG (2009) Mesh erosion as a complication of laparoscopic fundoplication with prosthetic hiatal closure: report of a case. Surg Laparosc Endosc Percut Tech 10:e51–e54CrossRef
15.
go back to reference Zehetner J, Demeester SR, Ayazi S, Kilday P, Augustin F, Hagen JA, Lipham JC, Sohn HJ, Demeester TR (2011) Laparoscopic versus open repair of paraesophageal hernia: the second decade. J Am Coll Surg (Epub ahead of print) Zehetner J, Demeester SR, Ayazi S, Kilday P, Augustin F, Hagen JA, Lipham JC, Sohn HJ, Demeester TR (2011) Laparoscopic versus open repair of paraesophageal hernia: the second decade. J Am Coll Surg (Epub ahead of print)
16.
go back to reference Luketich JD, Nason KS, Christie NA, Pennathur A, Jobe BA, Landreneau RJ, Schuchert MJ (2010) Outcomes after a decade of laparoscopic giant paraesophageal hernia repair. J Thorac Cardiovasc Surg 139:395–404PubMedCrossRef Luketich JD, Nason KS, Christie NA, Pennathur A, Jobe BA, Landreneau RJ, Schuchert MJ (2010) Outcomes after a decade of laparoscopic giant paraesophageal hernia repair. J Thorac Cardiovasc Surg 139:395–404PubMedCrossRef
17.
go back to reference Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A (2009) Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc 24:1017–1024PubMedCrossRef Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A (2009) Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc 24:1017–1024PubMedCrossRef
Metadata
Title
Use of mesh for hiatal hernia repair: a survey of SAGES members
Authors
Jason M. Pfluke
Michael Parker
Steven P. Bowers
Horacio J. Asbun
C. Daniel Smith
Publication date
01-07-2012
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 7/2012
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-012-2150-6

Other articles of this Issue 7/2012

Surgical Endoscopy 7/2012 Go to the issue