Skip to main content
Top
Published in: Surgical Endoscopy 5/2012

01-05-2012

The safety of biologic mesh for laparoscopic repair of large, complicated hiatal hernia

Authors: Eelco B. Wassenaar, Fernando Mier, Huseyin Sinan, Rebecca P. Petersen, A. Valeria Martin, Carlos A. Pellegrini, Brant K. Oelschlager

Published in: Surgical Endoscopy | Issue 5/2012

Login to get access

Abstract

Background

Biologic mesh is widely used for repair of large, complicated hiatal hernias. Recently, there have been reports of complications after its implantation. We studied the course of a large group of patients who had undergone hiatal hernia repair with use of biologic mesh to determine the rate of immediate and late complications related to its use.

Methods

All patients who had biologic mesh placed at the hiatus and who had been followed for at least 1 year were included. Perioperative data were reviewed, and a questionnaire was administered, designed to identify symptoms of gastroesophageal reflux, other symptoms such as dysphagia, and all other operative or endoscopic interventions that occurred after mesh implantation. In addition, postoperative radiologic and endoscopic studies were reviewed to assess signs of complications related to use of mesh.

Results

There were 126 patients eligible for the study. We were able to contact 73 of these patients, at median follow-up of 45 months. No mesh-related complications were found. The frequency and severity of heartburn, regurgitation, and dysphagia improved significantly compared with preoperative values, and 89% of the patients reported good to excellent results in terms of overall satisfaction. Six patients recorded worsening of dysphagia postoperatively, but after careful work-up and review of each individual case, no case seemed to be directly related to the mesh. No erosions, strictures, or other complications directly related to use of mesh were found. One patient required reoperation due to hiatal hernia recurrence with gastroesophageal reflux disease (GERD) symptoms.

Conclusions

Use of biologic mesh for laparoscopic repair of large, complicated hiatal hernias appears safe. There were no major complications related to the mesh, and overall satisfaction with the operation was very good.
Literature
1.
go back to reference Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583PubMed Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583PubMed
2.
go back to reference Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652PubMedCrossRef Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652PubMedCrossRef
3.
go back to reference Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48PubMedCrossRef Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48PubMedCrossRef
4.
go back to reference Trus TL, Bax T, Richardson WS, Branum GD, Mauren SJ, Swanstrom LL, Hunter JG (1997) Complications of laparoscopic paraesophageal hernia repair. J Gastrointest Surg 1:221–227 Discussion 228PubMedCrossRef Trus TL, Bax T, Richardson WS, Branum GD, Mauren SJ, Swanstrom LL, Hunter JG (1997) Complications of laparoscopic paraesophageal hernia repair. J Gastrointest Surg 1:221–227 Discussion 228PubMedCrossRef
5.
go back to reference Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJJ, Michael Brunt L, Hunter JG, Demeester TR, Swanstrom LL, Daniel Smith C, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJJ, Michael Brunt L, Hunter JG, Demeester TR, Swanstrom LL, Daniel Smith C, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef
6.
go back to reference Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2008) Complications of PTFE mesh at the diaphragmatic hiatus. J Gastrointest Surg 12:953–957PubMedCrossRef Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2008) Complications of PTFE mesh at the diaphragmatic hiatus. J Gastrointest Surg 12:953–957PubMedCrossRef
7.
go back to reference Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed
8.
go back to reference Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A (2010) Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc 24:1017–1024PubMedCrossRef Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A (2010) Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc 24:1017–1024PubMedCrossRef
9.
go back to reference Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8PubMedCrossRef Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8PubMedCrossRef
10.
go back to reference Lee E, Frisella MM, Matthews BD, Brunt LM (2007) Evaluation of acellular human dermis reinforcement of the crural closure in patients with difficult hiatal hernias. Surg Endosc 21:641–645PubMedCrossRef Lee E, Frisella MM, Matthews BD, Brunt LM (2007) Evaluation of acellular human dermis reinforcement of the crural closure in patients with difficult hiatal hernias. Surg Endosc 21:641–645PubMedCrossRef
11.
go back to reference Antoniou SA, Pointner R, Granderath FA (2011) Hiatal hernia repair with the use of biologic meshes: a literature review. Surg Laparosc Endosc Percutan Tech 21:1–9PubMedCrossRef Antoniou SA, Pointner R, Granderath FA (2011) Hiatal hernia repair with the use of biologic meshes: a literature review. Surg Laparosc Endosc Percutan Tech 21:1–9PubMedCrossRef
12.
go back to reference Hazebroek EJ, Leibman S, Smith GS (2009) Erosion of a composite PTFE/ePTFE mesh after hiatal hernia repair. Surg Laparosc Endosc Percutan Tech 19:175–177PubMedCrossRef Hazebroek EJ, Leibman S, Smith GS (2009) Erosion of a composite PTFE/ePTFE mesh after hiatal hernia repair. Surg Laparosc Endosc Percutan Tech 19:175–177PubMedCrossRef
13.
go back to reference Targarona EM, Bendahan G, Balague C, Garriga J, Trias M (2004) Mesh in the hiatus: a controversial issue. Arch Surg 139:1286–1296 Discussion 1296PubMedCrossRef Targarona EM, Bendahan G, Balague C, Garriga J, Trias M (2004) Mesh in the hiatus: a controversial issue. Arch Surg 139:1286–1296 Discussion 1296PubMedCrossRef
14.
go back to reference Griffith PS, Valenti V, Qurashi K, Martinez-Isla A (2008) Rejection of goretex mesh used in prosthetic cruroplasty: a case series. Int J Surg 6:106–109PubMedCrossRef Griffith PS, Valenti V, Qurashi K, Martinez-Isla A (2008) Rejection of goretex mesh used in prosthetic cruroplasty: a case series. Int J Surg 6:106–109PubMedCrossRef
15.
go back to reference Zugel N, Lang RA, Kox M, Huttl TP (2009) Severe complication of laparoscopic mesh hiatoplasty for paraesophageal hernia. Surg Endosc 23:2563–2567PubMedCrossRef Zugel N, Lang RA, Kox M, Huttl TP (2009) Severe complication of laparoscopic mesh hiatoplasty for paraesophageal hernia. Surg Endosc 23:2563–2567PubMedCrossRef
16.
go back to reference Carpelan-Holmstrom M, Kruuna O, Salo J, Kylanpaa L, Scheinin T (2010) Late mesh migration through the stomach wall after laparoscopic refundoplication using a dual-sided PTFE/ePTFE mesh. Hernia 15(2):217–220PubMedCrossRef Carpelan-Holmstrom M, Kruuna O, Salo J, Kylanpaa L, Scheinin T (2010) Late mesh migration through the stomach wall after laparoscopic refundoplication using a dual-sided PTFE/ePTFE mesh. Hernia 15(2):217–220PubMedCrossRef
17.
go back to reference Soricelli E, Basso N, Genco A, Cipriano M (2009) Long-term results of hiatal hernia mesh repair and antireflux laparoscopic surgery. Surg Endosc 23(11):2499–2504PubMedCrossRef Soricelli E, Basso N, Genco A, Cipriano M (2009) Long-term results of hiatal hernia mesh repair and antireflux laparoscopic surgery. Surg Endosc 23(11):2499–2504PubMedCrossRef
18.
go back to reference Parker M, Bowers SP, Bray JM, Harris AS, Belli EV, Pfluke JM, Preissler S, Asbun HJ, Smith CD (2010) Hiatal mesh is associated with major resection at revisional operation. Surg Endosc 24(12):3095–3101PubMedCrossRef Parker M, Bowers SP, Bray JM, Harris AS, Belli EV, Pfluke JM, Preissler S, Asbun HJ, Smith CD (2010) Hiatal mesh is associated with major resection at revisional operation. Surg Endosc 24(12):3095–3101PubMedCrossRef
19.
go back to reference Otto J, Kammer D, Jansen PL, Anurov M, Titkova S, Ottinger A, Rosch R, Schumpelick V, Jansen M (2008) Different tissue reaction of oesophagus and diaphragm after mesh hiatoplasty. Results of an animal study. BMC Surg 8:7PubMedCrossRef Otto J, Kammer D, Jansen PL, Anurov M, Titkova S, Ottinger A, Rosch R, Schumpelick V, Jansen M (2008) Different tissue reaction of oesophagus and diaphragm after mesh hiatoplasty. Results of an animal study. BMC Surg 8:7PubMedCrossRef
20.
go back to reference Gouvas N, Tsiaoussis J, Athanasakis E, Zervakis N, Pechlivanides G, Xynos E (2011) Simple suture or prosthesis hiatal closure in laparoscopic repair of paraesophageal hernia: a retrospective cohort study. Dis Esophagus 24(2):69–78PubMedCrossRef Gouvas N, Tsiaoussis J, Athanasakis E, Zervakis N, Pechlivanides G, Xynos E (2011) Simple suture or prosthesis hiatal closure in laparoscopic repair of paraesophageal hernia: a retrospective cohort study. Dis Esophagus 24(2):69–78PubMedCrossRef
21.
go back to reference Broeders JA, Draaisma WA, Bredenoord AJ, Smout AJ, Broeders IA, Gooszen HG (2010) Long-term outcome of Nissen fundoplication in non-erosive and erosive gastro-oesophageal reflux disease. Br J Surg 97:845–852PubMedCrossRef Broeders JA, Draaisma WA, Bredenoord AJ, Smout AJ, Broeders IA, Gooszen HG (2010) Long-term outcome of Nissen fundoplication in non-erosive and erosive gastro-oesophageal reflux disease. Br J Surg 97:845–852PubMedCrossRef
22.
go back to reference Oelschlager BK, Quiroga E, Parra JD, Cahill M, Polissar N, Pellegrini CA (2008) Long-term outcomes after laparoscopic antireflux surgery. Am J Gastroenterol 103:280–287 Quiz 288PubMedCrossRef Oelschlager BK, Quiroga E, Parra JD, Cahill M, Polissar N, Pellegrini CA (2008) Long-term outcomes after laparoscopic antireflux surgery. Am J Gastroenterol 103:280–287 Quiz 288PubMedCrossRef
23.
go back to reference Desai KM, Diaz S, Dorward IG, Winslow ER, La Regina MC, Halpin V, Soper NJ (2006) Histologic results 1 year after bioprosthetic repair of paraesophageal hernia in a canine model. Surg Endosc 20:1693–1697PubMedCrossRef Desai KM, Diaz S, Dorward IG, Winslow ER, La Regina MC, Halpin V, Soper NJ (2006) Histologic results 1 year after bioprosthetic repair of paraesophageal hernia in a canine model. Surg Endosc 20:1693–1697PubMedCrossRef
Metadata
Title
The safety of biologic mesh for laparoscopic repair of large, complicated hiatal hernia
Authors
Eelco B. Wassenaar
Fernando Mier
Huseyin Sinan
Rebecca P. Petersen
A. Valeria Martin
Carlos A. Pellegrini
Brant K. Oelschlager
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 5/2012
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-011-2045-y

Other articles of this Issue 5/2012

Surgical Endoscopy 5/2012 Go to the issue