Skip to main content
Top
Published in: Surgical Endoscopy 12/2009

01-12-2009 | New Technology

A novel laparoscopic device for measuring gastrointestinal slow-wave activity

Authors: Gregory O’Grady, Peng Du, John U. Egbuji, Wim J. E. P. Lammers, Athiq Wahab, Andrew J. Pullan, Leo K. Cheng, John A. Windsor

Published in: Surgical Endoscopy | Issue 12/2009

Login to get access

Abstract

Background

A periodic electrical activity, termed “slow waves”, coordinates gastrointestinal contractions. Slow-wave dysrhythmias are thought to contribute to dysmotility syndromes such as postoperative gastroparesis, but the clinical significance of these dysrhythmias remains poorly defined. Electrogastrography (EGG) has been unable to characterize dsyrhythmic activity reliably, and the most accurate method for evaluating slow waves is to record directly from the surface of the target organ. This study presents a novel laparoscopic device for recording serosal slow-wave activity, together with its validation.

Methods

The novel device consists of a shaft (diameter, 4 mm; length, 300 mm) and a flexible connecting cable. It contains four individual electrodes and is fully shielded. Validation was performed by comparing slow-wave recordings from the laparoscopic device with those from a standard electrode platform in an open-abdomen porcine model. An intraoperative human trial of the device also was performed by recording activity from the gastric antrum of a patient undergoing a laparoscopic cholecystectomy.

Results

Slow-wave amplitudes were similar between the laparoscopic device and the standard recording platform (mean 0.38 ± 0.03 mV vs range 0.36–0.38 ± 0.03 mV) (p = 0.94). The signal-to-noise ratio (SNR) also was similar between the two types of electrodes (13.7 dB vs 12.6 dB). High-quality antral slow-wave recordings were achieved in the intraoperative human trial (amplitude, 0.41 ± 0.04 mV; SNR, 12.6 dB), and an activation map was constructed showing normal aboral slow-wave propagation at a velocity of 6.3 ± 0.9 mm/s.

Conclusions

The novel laparoscopic device achieves high-quality serosal slow-wave recordings. It is easily deployable and atraumatic. It is anticipated that this device will aid in the clinical investigation of normal and dsyrhythmic slow-wave activity. In particular, it offers new potential for investigating the effect of surgical procedures on slow-wave activity.
Literature
1.
go back to reference Huizinga JD, Lammers WJEP (2009) Gut peristalsis is coordinated by a multitude of cooperating mechanisms. Am J Physiol Gastrointest Liver Physiol 296:G1–G8CrossRefPubMed Huizinga JD, Lammers WJEP (2009) Gut peristalsis is coordinated by a multitude of cooperating mechanisms. Am J Physiol Gastrointest Liver Physiol 296:G1–G8CrossRefPubMed
2.
go back to reference Cheng LK, O’Grady G, Du P, Egbuji J, Windsor JA, Pullan AJ (2009) Gastrointestinal system. Wiley Interdiscip Rev Syst Biol Med. doi:10.1002/wsbm.019 Cheng LK, O’Grady G, Du P, Egbuji J, Windsor JA, Pullan AJ (2009) Gastrointestinal system. Wiley Interdiscip Rev Syst Biol Med. doi:10.​1002/​wsbm.​019
3.
go back to reference Telander RL, Morgan KG, Kreulen DL, Scmalz PF, Kelly KA, Szurszewski JH (1978) Human gastric atony with tachygastria and gastric retention. Gastroenterology 75:497–501PubMed Telander RL, Morgan KG, Kreulen DL, Scmalz PF, Kelly KA, Szurszewski JH (1978) Human gastric atony with tachygastria and gastric retention. Gastroenterology 75:497–501PubMed
4.
go back to reference Chen JD, Schirmer BD, McCallum RW (1994) Serosal and cutaneous recordings of gastric myoelectrical activity in patients with gastroparesis. Am J Physiol 266:G90–G98PubMed Chen JD, Schirmer BD, McCallum RW (1994) Serosal and cutaneous recordings of gastric myoelectrical activity in patients with gastroparesis. Am J Physiol 266:G90–G98PubMed
5.
go back to reference Chen CL, Lin HH, Huang LC, Huang SC, Liu TT (2004) Electrogastrography differentiates reflux disease with or without dyspeptic symptoms. Dig Dis Sci 49:715–719CrossRefPubMed Chen CL, Lin HH, Huang LC, Huang SC, Liu TT (2004) Electrogastrography differentiates reflux disease with or without dyspeptic symptoms. Dig Dis Sci 49:715–719CrossRefPubMed
6.
go back to reference Hocking MP, Vogel SB, Sninsky CA (1992) Human gastric myoelectric activity and gastric emptying following gastric surgery and with pacing. Gastroenterology 103:1811–1816PubMed Hocking MP, Vogel SB, Sninsky CA (1992) Human gastric myoelectric activity and gastric emptying following gastric surgery and with pacing. Gastroenterology 103:1811–1816PubMed
7.
go back to reference Koch KL, Stern RM (2004) Handbook of electrogastrography. Oxford University Press, Oxford, England Koch KL, Stern RM (2004) Handbook of electrogastrography. Oxford University Press, Oxford, England
8.
go back to reference Lammers WJEP, Ver Donck L, Stephen B, Smets D, Schuurkes JAJ (2008) Focal activities and reentrant propagations as mechanisms of gastric tachyarrhythmias. Gastroenterology 135:1601–1611CrossRefPubMed Lammers WJEP, Ver Donck L, Stephen B, Smets D, Schuurkes JAJ (2008) Focal activities and reentrant propagations as mechanisms of gastric tachyarrhythmias. Gastroenterology 135:1601–1611CrossRefPubMed
9.
go back to reference Du P, O’Grady G, Egbuji J, Lammers WJ, Budgett D, Nielsen P, Windsor JA, Pullan AJ, Cheng LK (2009) High-resolution mapping of in vivo gastrointestinal slow-wave activity using flexible printed circuit board electrodes: methodology and validation. Ann Biomed Eng 37:839–846. doi:10.1007/s10439-009-9654-9 CrossRefPubMed Du P, O’Grady G, Egbuji J, Lammers WJ, Budgett D, Nielsen P, Windsor JA, Pullan AJ, Cheng LK (2009) High-resolution mapping of in vivo gastrointestinal slow-wave activity using flexible printed circuit board electrodes: methodology and validation. Ann Biomed Eng 37:839–846. doi:10.​1007/​s10439-009-9654-9 CrossRefPubMed
10.
go back to reference Lammers WJ, Stephen B, Arafat K, Manefield GW (1996) High-resolution electrical mapping in the gastrointestinal system: initial results. Neurogastroenterol Motil 8:207–216PubMed Lammers WJ, Stephen B, Arafat K, Manefield GW (1996) High-resolution electrical mapping in the gastrointestinal system: initial results. Neurogastroenterol Motil 8:207–216PubMed
11.
go back to reference Lammers WJ, Ver Donck L, Schuurkes JA, Stephen B (2005) Peripheral pacemakers and patterns of slow wave propagation in the canine small intestine in vivo. Can J Physiol Pharmacol 83:1031–1043CrossRefPubMed Lammers WJ, Ver Donck L, Schuurkes JA, Stephen B (2005) Peripheral pacemakers and patterns of slow wave propagation in the canine small intestine in vivo. Can J Physiol Pharmacol 83:1031–1043CrossRefPubMed
12.
go back to reference Familoni BO, Abell TL, Voeller G (1994) Measurement of gastric and small bowel electrical activity at laparoscopy. J Laparoendosc Surg 4:325–332PubMed Familoni BO, Abell TL, Voeller G (1994) Measurement of gastric and small bowel electrical activity at laparoscopy. J Laparoendosc Surg 4:325–332PubMed
13.
go back to reference Lammers WJ, Abazer FA, Ver Donck L, Smets D, Schuurkes JA, Coulie B (2006) Electrical activity in the rectum of anaesthetized dogs. Neurogastroenterol Motil 218:569–577CrossRef Lammers WJ, Abazer FA, Ver Donck L, Smets D, Schuurkes JA, Coulie B (2006) Electrical activity in the rectum of anaesthetized dogs. Neurogastroenterol Motil 218:569–577CrossRef
14.
go back to reference Lammers WJ, Donck LV, Schuurkes JA, Stephen B (2003) Longitudinal and circumferential spike patches in the canine small intestine in vivo. Am J Physiol Gastrointest Liver Physiol 285:G1014–G1027PubMed Lammers WJ, Donck LV, Schuurkes JA, Stephen B (2003) Longitudinal and circumferential spike patches in the canine small intestine in vivo. Am J Physiol Gastrointest Liver Physiol 285:G1014–G1027PubMed
15.
go back to reference Hinder RA, Kelly KA (1977) Human gastric pacesetter potential: site of origin, spread, and response to gastric transection and proximal gastric vagotomy. Am J Surg 133:29–33CrossRefPubMed Hinder RA, Kelly KA (1977) Human gastric pacesetter potential: site of origin, spread, and response to gastric transection and proximal gastric vagotomy. Am J Surg 133:29–33CrossRefPubMed
16.
go back to reference Abid S, Lindberg G (2007) Electrogastrography: poor correlation with antroduodenal manometry and doubtful clinical usefulness in adults. World J Gastroenterol 13:5101–5107PubMed Abid S, Lindberg G (2007) Electrogastrography: poor correlation with antroduodenal manometry and doubtful clinical usefulness in adults. World J Gastroenterol 13:5101–5107PubMed
17.
go back to reference Buist ML, Cheng LK, Sanders KM, Pullan AJ (2006) Multiscale modeling of human gastric electric activity: can the electrogastrogram detect functional electrical uncoupling? Exp Physiol 91:383–390CrossRefPubMed Buist ML, Cheng LK, Sanders KM, Pullan AJ (2006) Multiscale modeling of human gastric electric activity: can the electrogastrogram detect functional electrical uncoupling? Exp Physiol 91:383–390CrossRefPubMed
18.
go back to reference Bradshaw LA, Irimia A, Sims JA, Gallucci MR, Palmer PL, Richards WO (2006) Biomagnetic characterization of spatiotemporal parameters of the gastric slow wave. Neurogastroenterol Motil 18:619–631CrossRefPubMed Bradshaw LA, Irimia A, Sims JA, Gallucci MR, Palmer PL, Richards WO (2006) Biomagnetic characterization of spatiotemporal parameters of the gastric slow wave. Neurogastroenterol Motil 18:619–631CrossRefPubMed
19.
go back to reference Kwong NK, Brown BH, Whittaker GE, Duthie HL (1970) Electrical activity of the gastric antrum in man. Br J Surg 57:913–916CrossRefPubMed Kwong NK, Brown BH, Whittaker GE, Duthie HL (1970) Electrical activity of the gastric antrum in man. Br J Surg 57:913–916CrossRefPubMed
20.
go back to reference Coleski R, Hasler WL (2004) Directed endoscopic mucosal mapping of normal and dysrhythmic gastric slow waves in healthy humans. Neurogastroenterol Motil 16:557–565CrossRefPubMed Coleski R, Hasler WL (2004) Directed endoscopic mucosal mapping of normal and dysrhythmic gastric slow waves in healthy humans. Neurogastroenterol Motil 16:557–565CrossRefPubMed
21.
go back to reference Weber J, Kohatsu S (1970) Pacemaker localization and electrical conduction patterns in the canine stomach. Gastroenterology 59:717–726PubMed Weber J, Kohatsu S (1970) Pacemaker localization and electrical conduction patterns in the canine stomach. Gastroenterology 59:717–726PubMed
22.
go back to reference Hocking MP, Harrison WD, Sninsky CA (1990) Gastric dysrhythmias following pylorus-preserving pancreaticoduodenectomy: possible mechanism for early delayed gastric emptying. Dig Dis Sci 35:1226–1230CrossRefPubMed Hocking MP, Harrison WD, Sninsky CA (1990) Gastric dysrhythmias following pylorus-preserving pancreaticoduodenectomy: possible mechanism for early delayed gastric emptying. Dig Dis Sci 35:1226–1230CrossRefPubMed
23.
go back to reference Hocking MP (1993) Postoperative gastroparesis and tachygastria: response to electric stimulation and erythromycin. Surgery 114:538–542PubMed Hocking MP (1993) Postoperative gastroparesis and tachygastria: response to electric stimulation and erythromycin. Surgery 114:538–542PubMed
24.
go back to reference Hasler WL (2009) Methods of gastric electrical stimulation and pacing: a review of their benefits and mechanisms of action in gastroparesis and obesity. Neurogastroenterol Motil 21:229–243CrossRefPubMed Hasler WL (2009) Methods of gastric electrical stimulation and pacing: a review of their benefits and mechanisms of action in gastroparesis and obesity. Neurogastroenterol Motil 21:229–243CrossRefPubMed
25.
go back to reference Ver Donck L, Lammers WJ, Moreaux B, Smets D, Voeten J, Vekemans J, Schuurkes JA, Coulie B (2006) Mapping slow waves and spikes in chronically instrumented conscious dogs: implantation techniques and recordings. Med Biol Eng Comput 44:170–178CrossRefPubMed Ver Donck L, Lammers WJ, Moreaux B, Smets D, Voeten J, Vekemans J, Schuurkes JA, Coulie B (2006) Mapping slow waves and spikes in chronically instrumented conscious dogs: implantation techniques and recordings. Med Biol Eng Comput 44:170–178CrossRefPubMed
Metadata
Title
A novel laparoscopic device for measuring gastrointestinal slow-wave activity
Authors
Gregory O’Grady
Peng Du
John U. Egbuji
Wim J. E. P. Lammers
Athiq Wahab
Andrew J. Pullan
Leo K. Cheng
John A. Windsor
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 12/2009
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-009-0515-2

Other articles of this Issue 12/2009

Surgical Endoscopy 12/2009 Go to the issue