Background

The direction of visual gaze may be an important ergonomic factor that affects operative performance. We designed a study to determine whether a head-mounted display (HMD) worn by the surgeon would improve task performance and/or reduce muscle fatigue during a laparoscopic task when compared to the use of a traditional video monitor display (VMD).

Methods

Surgical residents (n = 30) were enrolled in the study. A junior group, consisting of 15 postgraduate year (PGY) = 1 subjects with no previous laparoscopic experience, and a senior group, consisting of 15 PGY 4 and PGY 5 subjects with experience, completed a laparoscopic task that was repeated four times using the Computer Enhanced Laparoscopic Training System (CELTS). Groups alternated between using the HMD with the task placed in a downward frontal position and the VMD with the task at a 30° lateral angle. The CELTS module assessed task completion time, depth perception, path length of instruments, response orientation, motion smoothness; the system then generated an overall score. Electromyography (EMG) was used to record sternocleidomastoid muscle activity. Display preference was surveyed.

Results

The senior residents performed better than the junior residents overall on all parameters (p < 0.05) except for motion smoothness, where there was no difference. In both groups, the HMD significantly improved motion smoothness when compared to the VMD (p < 0.05). All other parameters were equal. There was less muscle fatigue when using the VMD (p < 0.05). We found that 66% of the junior residents but only 20% of the senior residents preferred the HMD.

Conclusions

The CELTS module demonstrated evidence of construct validity by differentiating the performances of junior and senior residents. By aligning the surgeon’s visual gaze with the instruments, HMD improved smoothness of motion. Experienced residents preferred the traditional monitor display. Although the VMD produced less muscle fatigue, inexperienced residents preferred the HMD, possibly because of improved smoothness of motion.
Literature
1.
go back to reference Arndt, R 1983Working posture and musculoskeletal problems of video display terminal operators-review and reappraisalAm Indus Hygiene Assoc44437446 Arndt, R 1983Working posture and musculoskeletal problems of video display terminal operators-review and reappraisalAm Indus Hygiene Assoc44437446
2.
go back to reference Berguer, R 1997Surgical technology and the ergonomics of laparoscopic instrumentsSurg Endosc12458462CrossRef Berguer, R 1997Surgical technology and the ergonomics of laparoscopic instrumentsSurg Endosc12458462CrossRef
3.
go back to reference Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during lagaroscopic and open surgical proceduresSurg Endosc11139142CrossRefPubMed Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during lagaroscopic and open surgical proceduresSurg Endosc11139142CrossRefPubMed
4.
go back to reference Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgerySurg Endosc13466468CrossRefPubMed Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgerySurg Endosc13466468CrossRefPubMed
5.
go back to reference Berguer, R, Chen, CY, Smith, WD 1999A virtual instrument ergonomics workstation, to measure surgeons’ physical stressStud Health Technol Inform624954PubMed Berguer, R, Chen, CY, Smith, WD 1999A virtual instrument ergonomics workstation, to measure surgeons’ physical stressStud Health Technol Inform624954PubMed
6.
go back to reference Berguer, R, Forkey, DL, Smith, WD 1999The effect of laparoscopic instrument working angle on surgeons’ upper extremity workloadSurg Enodosc1510271029 Berguer, R, Forkey, DL, Smith, WD 1999The effect of laparoscopic instrument working angle on surgeons’ upper extremity workloadSurg Enodosc1510271029
7.
go back to reference Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgerySurg Endosc1512041207CrossRefPubMed Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgerySurg Endosc1512041207CrossRefPubMed
8.
go back to reference Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic taskSurg Endosc15990991CrossRefPubMed Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic taskSurg Endosc15990991CrossRefPubMed
9.
go back to reference Cotin, S, Stylopoulos, N, Dawson, S, Ottensmeyer, M, Neumann, P, Bardsley, R, Russel, M, et al. 2003CELTS: a clinically-based Computer Enhanced Laparoscopic Training SystemStud Health Technol Inform94336342PubMed Cotin, S, Stylopoulos, N, Dawson, S, Ottensmeyer, M, Neumann, P, Bardsley, R, Russel, M,  et al. 2003CELTS: a clinically-based Computer Enhanced Laparoscopic Training SystemStud Health Technol Inform94336342PubMed
10.
go back to reference Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image displayAnn Surg227481484CrossRefPubMed Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image displayAnn Surg227481484CrossRefPubMed
11.
go back to reference Leoni, FMQ, Molle, F, Scavino, G, Dicknian, A 1994Identification of the preferential gaze position through evaluation of visual fatigue in a selected group of VDU operatorsDoc Ophthalmol87189197CrossRefPubMed Leoni, FMQ, Molle, F, Scavino, G, Dicknian, A 1994Identification of the preferential gaze position through evaluation of visual fatigue in a selected group of VDU operatorsDoc Ophthalmol87189197CrossRefPubMed
12.
go back to reference Menozzi, M, Buol, AV, Miege, C 1994Direction of gaze and comfort: discovering the relation for the ergonomic optimization of visual tasksOphthal Physiology14393399CrossRef Menozzi, M, Buol, AV, Miege, C 1994Direction of gaze and comfort: discovering the relation for the ergonomic optimization of visual tasksOphthal Physiology14393399CrossRef
13.
go back to reference Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, DeVera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgeryAm J Surg182720724CrossRefPubMed Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, DeVera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgeryAm J Surg182720724CrossRefPubMed
14.
go back to reference Smith, WD, Chung, YH, Berguer, R 2000A virtual instrument ergonomics workstation for measuring the mental workload of performing video-endoscopic surgeryStud Health Technol Inform70309315PubMed Smith, WD, Chung, YH, Berguer, R 2000A virtual instrument ergonomics workstation for measuring the mental workload of performing video-endoscopic surgeryStud Health Technol Inform70309315PubMed
15.
go back to reference Stylopoulos, N, Cotin, S, Maithel, SK, Ottensmeyer, M, Jackson, P, Bardsley, R, Neumann, P, et al. 2004Computer Enhanced Lapagoscopic Training System (CELTS): bridging the gapSurg Endosc18782789CrossRefPubMed Stylopoulos, N, Cotin, S, Maithel, SK, Ottensmeyer, M, Jackson, P, Bardsley, R, Neumann, P,  et al. 2004Computer Enhanced Lapagoscopic Training System (CELTS): bridging the gapSurg Endosc18782789CrossRefPubMed
16.
go back to reference VanKoesveld, JJM, Tetteroo, GWM, deGraff, EJR 2003Use of head-mounted display in transanal endoscopic microsurgerySurg Endosc17943946CrossRefPubMed VanKoesveld, JJM, Tetteroo, GWM, deGraff, EJR 2003Use of head-mounted display in transanal endoscopic microsurgerySurg Endosc17943946CrossRefPubMed
17.
go back to reference Veelen, MA, Kazemier, G, Koopman, J, Goossens, RH, Meijer, DW 2002Assessment of the economically optimal operating surface height for laparoscopic surgeryJ Laparoendosc Adv Surg Tech124752CrossRef Veelen, MA, Kazemier, G, Koopman, J, Goossens, RH, Meijer, DW 2002Assessment of the economically optimal operating surface height for laparoscopic surgeryJ Laparoendosc Adv Surg Tech124752CrossRef
Metadata
Title
Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue
Authors
S. K. Maithel
L. Villegas
N. Stylopoulos
S. Dawson
D. B. Jones
Publication date
01-03-2005
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 3/2005
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-004-8177-6

Other articles of this Issue 3/2005

Surgical Endoscopy 3/2005 Go to the issue

Announcements

News and notices