Skip to main content
Top
Published in: European Journal of Applied Physiology 11/2022

Open Access 10-08-2022 | Original Article

A three-minute all-out test performed in a remote setting does not provide a valid estimate of the maximum metabolic steady state

Authors: Ed Maunder, Jeffrey A. Rothschild, Andrius Ramonas, Matthieu Delcourt, Andrew E. Kilding

Published in: European Journal of Applied Physiology | Issue 11/2022

Login to get access

Abstract

Purpose

The three-minute all-out test (3MT), when performed on a laboratory ergometer in a linear mode, can be used to estimate the heavy–severe-intensity transition, or maximum metabolic steady state (MMSS), using the end-test power output. As the 3MT only requires accurate measurement of power output and time, it is possible the 3MT could be used in remote settings using personal equipment without supervision for quantification of MMSS.

Methods

The aim of the present investigation was to determine the reliability and validity of remotely performed 3MTs (3MTR) for estimation of MMSS. Accordingly, 53 trained cyclists and triathletes were recruited to perform one familiarisation and two experimental 3MTR trials to determine its reliability. A sub-group (N = 10) was recruited to perform three-to-five 30 min laboratory-based constant-work rate trials following completion of one familiarisation and two experimental 3MTR trials. Expired gases were collected throughout constant-work rate trials and blood lactate concentration was measured at 10 and 30 min to determine the highest power output at which steady-state \({{\dot{V}O}}_{2}\) (MMSS-\({{\dot{V}O}}_{2}\)) and blood lactate (MMSS-[La]) were achieved.

Results

The 3MTR end-test power (EPremote) was reliable (coefficient of variation, 4.5% [95% confidence limits, 3.7, 5.5%]), but overestimated MMSS (EPremote, 283 ± 51 W; MMSS-\({{\dot{V}O}}_{2}\), 241 ± 46 W, P = 0.0003; MMSS-[La], 237 ± 47 W, P = 0.0003). This may have been due to failure to deplete the finite work capacity above MMSS during the 3MTR.

Conclusion

These results suggest that the 3MTR should not be used to estimate MMSS in endurance-trained cyclists.
Literature
go back to reference Hoon M, Michael S, Chapman P, Areta JL (2016) A comparison of the accuracy and reliability of the Wahoo KICKR and SRM power meter. J Sci Cycl 5:11–15 Hoon M, Michael S, Chapman P, Areta JL (2016) A comparison of the accuracy and reliability of the Wahoo KICKR and SRM power meter. J Sci Cycl 5:11–15
Metadata
Title
A three-minute all-out test performed in a remote setting does not provide a valid estimate of the maximum metabolic steady state
Authors
Ed Maunder
Jeffrey A. Rothschild
Andrius Ramonas
Matthieu Delcourt
Andrew E. Kilding
Publication date
10-08-2022
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Applied Physiology / Issue 11/2022
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-022-05020-3

Other articles of this Issue 11/2022

European Journal of Applied Physiology 11/2022 Go to the issue