Skip to main content
Top
Published in: European Journal of Applied Physiology 1/2011

01-01-2011 | Short Communication

Cardiac output but not stroke volume is similar in a Wingate and \( \dot{V}{\text{O}}_{{ 2 {\text{peak}}}} \) test in young men

Authors: Piero Fontana, Katharina Betschon, Urs Boutellier, Marco Toigo

Published in: European Journal of Applied Physiology | Issue 1/2011

Login to get access

Abstract

Wingate test (WT) training programmes lasting 2–3 weeks lead to improved peak oxygen consumption. If a single 30 s WT was capable of significantly increasing stroke volume and cardiac output, the increase in peak oxygen consumption could possibly be explained by improved oxygen delivery. Thus, we investigated whether a single WT increases stroke volume and cardiac output to similar levels than those obtained at peak exercise during a graded cycling exercise test (GXT) to exhaustion. Fifteen healthy young men (peak oxygen consumption 45.0 ± 5.3 ml kg−1 min−1) performed one WT and one GXT on separate days in randomised order. During the tests, we estimated cardiac output using inert gas rebreathing (nitrous oxide and sulphur hexafluoride) and subsequently calculated stroke volume. We found that cardiac output was similar (18.2 ± 3.3 vs. 17.9 ± 2.6 l min−1; P = 0.744), stroke volume was higher (127 ± 37 vs. 94 ± 15 ml; P < 0.001), and heart rate was lower (149 ± 26 vs. 190 ± 12 beats min−1; P < 0.001) at the end (27 ± 2 s) of a WT as compared to peak exercise during a GXT. Our results suggest that a single WT produces a haemodynamic response which is characterised by similar cardiac output, higher stroke volume and lower heart rate as compared to peak exercise during a GXT.
Literature
go back to reference Burgomaster KA, Hughes SC, Heigenhauser GJ, Bradwell SN, Gibala MJ (2005) Six sessions of sprint interval training increases muscle oxidative potential and cycle endurance capacity in humans. J Appl Physiol 98:1985–1990CrossRefPubMed Burgomaster KA, Hughes SC, Heigenhauser GJ, Bradwell SN, Gibala MJ (2005) Six sessions of sprint interval training increases muscle oxidative potential and cycle endurance capacity in humans. J Appl Physiol 98:1985–1990CrossRefPubMed
go back to reference Burgomaster KA, Howarth KR, Phillips SM, Rakobowchuk M, Macdonald MJ, McGee SL, Gibala MJ (2008) Similar metabolic adaptations during exercise after low volume sprint interval and traditional endurance training in humans. J Physiol (Lond) 586:151–160CrossRef Burgomaster KA, Howarth KR, Phillips SM, Rakobowchuk M, Macdonald MJ, McGee SL, Gibala MJ (2008) Similar metabolic adaptations during exercise after low volume sprint interval and traditional endurance training in humans. J Physiol (Lond) 586:151–160CrossRef
go back to reference Calbet JA, González-Alonso J, Helge JW, Sondergaard H, Munch-Andersen T, Boushel R, Saltin B (2007) Cardiac output and leg and arm blood flow during incremental exercise to exhaustion on the cycle ergometer. J Appl Physiol 103:969–978CrossRefPubMed Calbet JA, González-Alonso J, Helge JW, Sondergaard H, Munch-Andersen T, Boushel R, Saltin B (2007) Cardiac output and leg and arm blood flow during incremental exercise to exhaustion on the cycle ergometer. J Appl Physiol 103:969–978CrossRefPubMed
go back to reference Daussin FN, Ponsot E, Dufour SP, Lonsdorfer-Wolf E, Doutreleau S, Geny B, Piquard F, Richard R (2007) Improvement of VO2max by cardiac output and oxygen extraction adaptation during intermittent versus continuous endurance training. Eur J Appl Physiol 101:377–383CrossRefPubMed Daussin FN, Ponsot E, Dufour SP, Lonsdorfer-Wolf E, Doutreleau S, Geny B, Piquard F, Richard R (2007) Improvement of VO2max by cardiac output and oxygen extraction adaptation during intermittent versus continuous endurance training. Eur J Appl Physiol 101:377–383CrossRefPubMed
go back to reference Eldridge MW, Dempsey JA, Haverkamp HC, Lovering AT, Hokanson JS (2004) Exercise-induced intrapulmonary arteriovenous shunting in healthy humans. J Appl Physiol 97:797–805CrossRefPubMed Eldridge MW, Dempsey JA, Haverkamp HC, Lovering AT, Hokanson JS (2004) Exercise-induced intrapulmonary arteriovenous shunting in healthy humans. J Appl Physiol 97:797–805CrossRefPubMed
go back to reference Fick A (1870) Über die Messung des Blutquantums in den Herzventrikeln. Sitzung Phys med Gesell Würzburg 14:16 Fick A (1870) Über die Messung des Blutquantums in den Herzventrikeln. Sitzung Phys med Gesell Würzburg 14:16
go back to reference Fontana P, Boutellier U, Toigo M (2009) Reliability of measurements with Innocor™ during exercise. Int J Sports Med 30:747–753CrossRefPubMed Fontana P, Boutellier U, Toigo M (2009) Reliability of measurements with Innocor during exercise. Int J Sports Med 30:747–753CrossRefPubMed
go back to reference Fontana P, Boutellier U, Toigo M (2010) Non-invasive haemodynamic assessments using Innocor™ during standard graded exercise tests. Eur J Appl Physiol 108:573–580CrossRefPubMed Fontana P, Boutellier U, Toigo M (2010) Non-invasive haemodynamic assessments using Innocor during standard graded exercise tests. Eur J Appl Physiol 108:573–580CrossRefPubMed
go back to reference Hazell TJ, MacPherson REK, Gravelle BMR, Lemon PWR (2010) 10 or 30-s sprint interval training bouts enhance both aerobic and anaerobic performance. Eur J Appl Physiol. doi:10.1007/s00421-010-1474-y Hazell TJ, MacPherson REK, Gravelle BMR, Lemon PWR (2010) 10 or 30-s sprint interval training bouts enhance both aerobic and anaerobic performance. Eur J Appl Physiol. doi:10.​1007/​s00421-010-1474-y
go back to reference Helgerud J, Høydal K, Wang E, Karlsen T, Berg P, Bjerkaas M, Simonsen T, Helgesen C, Hjorth N, Bach R, Hoff J (2007) Aerobic high-intensity intervals improve VO2max more than moderate training. Med Sci Sports Exerc 39:665–671CrossRefPubMed Helgerud J, Høydal K, Wang E, Karlsen T, Berg P, Bjerkaas M, Simonsen T, Helgesen C, Hjorth N, Bach R, Hoff J (2007) Aerobic high-intensity intervals improve VO2max more than moderate training. Med Sci Sports Exerc 39:665–671CrossRefPubMed
go back to reference Mortensen SP, Dawson EA, Yoshiga CC, Dalsgaard MK, Damsgaard R, Secher NH, Gonzalez-Alonso J (2005) Limitations to systemic and locomotor limb muscle oxygen delivery and uptake during maximal exercise in humans. J Physiol (Lond) 566:273–285CrossRef Mortensen SP, Dawson EA, Yoshiga CC, Dalsgaard MK, Damsgaard R, Secher NH, Gonzalez-Alonso J (2005) Limitations to systemic and locomotor limb muscle oxygen delivery and uptake during maximal exercise in humans. J Physiol (Lond) 566:273–285CrossRef
go back to reference Sagiv M, Ben-Sira D, Goldhammer E, Soudry M (2000) Left ventricular contractility and function at peak aerobic and anaerobic exercises. Med Sci Sports Exerc 32:1197–1201CrossRefPubMed Sagiv M, Ben-Sira D, Goldhammer E, Soudry M (2000) Left ventricular contractility and function at peak aerobic and anaerobic exercises. Med Sci Sports Exerc 32:1197–1201CrossRefPubMed
Metadata
Title
Cardiac output but not stroke volume is similar in a Wingate and test in young men
Authors
Piero Fontana
Katharina Betschon
Urs Boutellier
Marco Toigo
Publication date
01-01-2011
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 1/2011
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1645-x

Other articles of this Issue 1/2011

European Journal of Applied Physiology 1/2011 Go to the issue