Skip to main content
Top
Published in: European Journal of Applied Physiology 1/2008

01-09-2008 | Original Article

Heart rate and blood pressure time courses during prolonged dry apnoea in breath-hold divers

Authors: Renza Perini, Adelaide Tironi, Alberto Gheza, Ferdinando Butti, Christian Moia, Guido Ferretti

Published in: European Journal of Applied Physiology | Issue 1/2008

Login to get access

Abstract

To define the dynamics of cardiovascular adjustments to apnoea, beat-to-beat heart rate (HR) and blood pressure and arterial oxygen saturation (SaO2) were recorded during prolonged breath-holding in air in 20 divers. Apnoea had a mean duration of 210 ± 70 s. In all subjects, HR attained a value 14 beats min−1 lower than control within the initial 30 s (phase I). HR did not change for the following 2–2.5 min (phase II). Then, nine subjects interrupted the apnoea (group A), whereas 11 subjects (group B) could prolong the breath-holding for about 100 s, during which HR continuously decreased (phase III). In both groups, mean blood pressure was 8 mmHg above control at the end of phase I; it then further increased by additional 12 mmHg at the end of the apnoea. In both groups, SaO2 did not change in the initial 100–140 s of apnoea; then, it decreased to 95% at the end of phase II. In group B, SaO2 further diminished to 84% at the end of phase III. A typical pattern of cardiovascular readjustments was identified during dry apnoea. This pattern was not compatible with a role for baroreflexes in phase I and phase II. Further readjustment in group B may imply a role for both baroreflexes and chemoreflexes. Hypothesis has been made that the end of phase II corresponds to physiological breakpoint.
Literature
go back to reference Andersson J, Schagatay E (1998) Effects of lung volume and involuntary breathing movements on the human diving response. Eur J Appl Physiol 77:19–24CrossRef Andersson J, Schagatay E (1998) Effects of lung volume and involuntary breathing movements on the human diving response. Eur J Appl Physiol 77:19–24CrossRef
go back to reference Andersson J, Schagatay E, Gislen A, Holm B (2000) Cardiovascular responses to cold-water immersions of the forearm and face, and their relationship to apnoea. Eur J Appl Physiol 83:566–572PubMedCrossRef Andersson J, Schagatay E, Gislen A, Holm B (2000) Cardiovascular responses to cold-water immersions of the forearm and face, and their relationship to apnoea. Eur J Appl Physiol 83:566–572PubMedCrossRef
go back to reference Andersson JPA, Liner MH, Rünow E, Schagatay EKA (2002) Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers. J Appl Physiol 93:882–886PubMed Andersson JPA, Liner MH, Rünow E, Schagatay EKA (2002) Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers. J Appl Physiol 93:882–886PubMed
go back to reference Andersson JPA, Liner MH, Fredsted A, Schagatay EKA (2004) Cardiovascular and respiratory responses to apneas with and without face immersion in exercising humans. J Appl Physiol 96:1005–1010PubMedCrossRef Andersson JPA, Liner MH, Fredsted A, Schagatay EKA (2004) Cardiovascular and respiratory responses to apneas with and without face immersion in exercising humans. J Appl Physiol 96:1005–1010PubMedCrossRef
go back to reference Bakovic D, Valic Z, Eterovic D, Vukocic I, Obad A, Marinovic-Terzic I, Dujic Z (2003) Spleen volume and blood flow response to repeated breath-hold apneas. J Appl Physiol 95:1460–1466PubMed Bakovic D, Valic Z, Eterovic D, Vukocic I, Obad A, Marinovic-Terzic I, Dujic Z (2003) Spleen volume and blood flow response to repeated breath-hold apneas. J Appl Physiol 95:1460–1466PubMed
go back to reference Ferretti G, Costa M, Ferrigno M, Grassi B, Marconi C, Lundgren CEG, Cerretelli P (1991) Alveolar gas composition and exchange during deep breath-hold diving and dry breath-holds in elite divers. J Appl Physiol 70:794–802PubMed Ferretti G, Costa M, Ferrigno M, Grassi B, Marconi C, Lundgren CEG, Cerretelli P (1991) Alveolar gas composition and exchange during deep breath-hold diving and dry breath-holds in elite divers. J Appl Physiol 70:794–802PubMed
go back to reference Ferrigno M, Grassi B, Ferretti G, Costa M, Marconi C, Cerretelli P, Lundgren C (1991) Electrocardiogram during deep breath-hold dives by elite divers. Undersea Biomed Res 18:81–91PubMed Ferrigno M, Grassi B, Ferretti G, Costa M, Marconi C, Cerretelli P, Lundgren C (1991) Electrocardiogram during deep breath-hold dives by elite divers. Undersea Biomed Res 18:81–91PubMed
go back to reference Ferrigno M, Ferretti G, Ellis A, Warkander D, Costa M, Cerretelli P, Lundgren CEG (1997) Cardiovascular changes during deep breath-hold dives in a pressure chamber. J Appl Physiol 83:1282–1290PubMed Ferrigno M, Ferretti G, Ellis A, Warkander D, Costa M, Cerretelli P, Lundgren CEG (1997) Cardiovascular changes during deep breath-hold dives in a pressure chamber. J Appl Physiol 83:1282–1290PubMed
go back to reference Foster GE, Sheel AW (2005) The human diving response, its function, and its control. Scand J Med Sci Sports 15:3–12PubMedCrossRef Foster GE, Sheel AW (2005) The human diving response, its function, and its control. Scand J Med Sci Sports 15:3–12PubMedCrossRef
go back to reference Gallagher KM, Fadel PJ, Smith SA, Stromstad M, Ide K, Secher NH, Raven PB (2006) The interaction of central command and the exercise pressor reflex in mediating baroreflex resetting during exercise in humans. Exp Physiol 91:79–87PubMedCrossRef Gallagher KM, Fadel PJ, Smith SA, Stromstad M, Ide K, Secher NH, Raven PB (2006) The interaction of central command and the exercise pressor reflex in mediating baroreflex resetting during exercise in humans. Exp Physiol 91:79–87PubMedCrossRef
go back to reference Journeay WS, Reardon FD, Kenny GP (2003) Cardiovascular responses to apneic facial immersion during altered cardiac filling. J Appl Physiol 94:2249–2254PubMed Journeay WS, Reardon FD, Kenny GP (2003) Cardiovascular responses to apneic facial immersion during altered cardiac filling. J Appl Physiol 94:2249–2254PubMed
go back to reference Lemaitre F, Bernier F, Petit I, Renard N, Gardette B, Joulia F (2005) Heart rate responses during a breath-holding competition in well-trained divers. Int J Sports Med 26:409–413PubMedCrossRef Lemaitre F, Bernier F, Petit I, Renard N, Gardette B, Joulia F (2005) Heart rate responses during a breath-holding competition in well-trained divers. Int J Sports Med 26:409–413PubMedCrossRef
go back to reference Leuenberger UA, Hardy JC, Herr MD, Gray KS, Sinoway LI (2001) Hypoxia augments apnea-induced peripheral vasoconstriction in humans. J Appl Physiol 90:1516–1522PubMedCrossRef Leuenberger UA, Hardy JC, Herr MD, Gray KS, Sinoway LI (2001) Hypoxia augments apnea-induced peripheral vasoconstriction in humans. J Appl Physiol 90:1516–1522PubMedCrossRef
go back to reference Lin JC, Lally DA, Moore TO, Hong SK (1974) Physiological and conventional breath-hold breaking points. J Appl Physiol 37:291–296PubMed Lin JC, Lally DA, Moore TO, Hong SK (1974) Physiological and conventional breath-hold breaking points. J Appl Physiol 37:291–296PubMed
go back to reference Lindholm P, Sundblad P, Linnarsson D (1999) Oxygen-conserving effects of apnea in exercising men. J Appl Physiol 87:2122–2127PubMed Lindholm P, Sundblad P, Linnarsson D (1999) Oxygen-conserving effects of apnea in exercising men. J Appl Physiol 87:2122–2127PubMed
go back to reference Lindholm P, Linnarsson D (2002) Pulmonary gas exchange during apnoea in exercising men. Eur J Appl Physiol 86:487–491PubMedCrossRef Lindholm P, Linnarsson D (2002) Pulmonary gas exchange during apnoea in exercising men. Eur J Appl Physiol 86:487–491PubMedCrossRef
go back to reference Lindholm P, Nordh J, Linnarsson D (2002) Role of hypoxemia for the cardiovascular response to apnea during exercise. Am J Physiol Regul Integr Comp Physiol 283:R1227–R1235PubMed Lindholm P, Nordh J, Linnarsson D (2002) Role of hypoxemia for the cardiovascular response to apnea during exercise. Am J Physiol Regul Integr Comp Physiol 283:R1227–R1235PubMed
go back to reference Palada I, Eterovic D, Obad A, Bakovic D, Valic Z, Ivancev V, Lojour M, Shoemaker JK, Dujic Z (2007) Spleen and cardiovascular function during short apneas in divers. J Appl Physiol 103:1958–1963PubMedCrossRef Palada I, Eterovic D, Obad A, Bakovic D, Valic Z, Ivancev V, Lojour M, Shoemaker JK, Dujic Z (2007) Spleen and cardiovascular function during short apneas in divers. J Appl Physiol 103:1958–1963PubMedCrossRef
go back to reference Saul JP (1990) Beat-to beat variations of heart rate reflect modulation of cardiac autonomic outflow. News Physiol Sci 5:32–37 Saul JP (1990) Beat-to beat variations of heart rate reflect modulation of cardiac autonomic outflow. News Physiol Sci 5:32–37
go back to reference Schagatay E, Andersson J (1998) Diving response and apneic time in humans. Undersea Hyperb Med 25:13–19PubMed Schagatay E, Andersson J (1998) Diving response and apneic time in humans. Undersea Hyperb Med 25:13–19PubMed
go back to reference Stewart IB, Bulmer AC, Sharman JE, Ridgway L (2005) Arterial oxygen desaturation kinetics during apnea. Med Sci Sports Exerc 37:1871–1876PubMedCrossRef Stewart IB, Bulmer AC, Sharman JE, Ridgway L (2005) Arterial oxygen desaturation kinetics during apnea. Med Sci Sports Exerc 37:1871–1876PubMedCrossRef
go back to reference Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology (1996) Heart rate variability: standards of measurements, physiological interpretation, and clinical use. Circulation 93:1043–1065 Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology (1996) Heart rate variability: standards of measurements, physiological interpretation, and clinical use. Circulation 93:1043–1065
Metadata
Title
Heart rate and blood pressure time courses during prolonged dry apnoea in breath-hold divers
Authors
Renza Perini
Adelaide Tironi
Alberto Gheza
Ferdinando Butti
Christian Moia
Guido Ferretti
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 1/2008
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-008-0771-1

Other articles of this Issue 1/2008

European Journal of Applied Physiology 1/2008 Go to the issue