Skip to main content
Top
Published in: European Journal of Applied Physiology 2-3/2005

01-10-2005 | Original Article

Comparison between leg and arm eccentric exercises of the same relative intensity on indices of muscle damage

Authors: Athanasios Z. Jamurtas, V. Theocharis, T. Tofas, A. Tsiokanos, C. Yfanti, V. Paschalis, Y. Koutedakis, K. Nosaka

Published in: European Journal of Applied Physiology | Issue 2-3/2005

Login to get access

Abstract

Many exercise models have demonstrated associations between eccentric muscle actions and muscle damage. However, the magnitude of muscle damage varies among the models. It appears that responses to eccentric exercise are different between leg and arm muscles but this has not been systematically clarified. This study compared leg and arm eccentric exercises of the same relative intensity for indices of muscle damage. Eleven healthy untrained males [Age: 21.2 (1.0) years, Height: 179.4 (3.0) cm, Weight: 78.4 (3.1) kg] performed a sub-maximal eccentric exercise of the knee extensors (LEGS) and the elbow flexors (ARMS), separately. Both LEGS and ARMS consisted of six sets of 12 repetitions with an intensity corresponding to 75% of the predetermined maximal eccentric peak torque (EPT) of each muscle. Range of motion (ROM), delayed onset muscle soreness (DOMS), serum creatine kinase (CK) and lactate dehydrogenase (LDH) activities, myoglobin (Mb) concentration, and muscle strength [EPT and isometric peak torque (IPT)] were assessed before and 24, 48, 72, and 96 h following exercise. Significant (P<0.05) changes in DOMS and ROM were observed up to 96 h after both exercise bouts, and the magnitude of the change was similar between LEGS and ARMS. Increases in CK and Mb were significantly (P<0.05) larger after ARMS than LEGS at 72 and 96 h post-exercise. EPT and IPT were significantly (P<0.05) lower than the baseline up to 96 h post-exercise for ARMS but were fully recovered by 96 h post-exercise for LEGS. Decreases in muscle strength were significantly (p<0.05) larger following ARMS than LEGS at 48, 72, and 96 h post-exercise for EPT, and from 24 h to 96 h post-exercise for IPT. These results suggest that the magnitude of muscle damage is greater and the recovery of muscle function was slower after eccentric exercise of arm elbow flexors than the knee extensors.
Literature
go back to reference Brown SJ, Child RB, Day SH, Donnelly AE (1997) Indices of skeletal muscle damage and connective tissue breakdown following eccentric muscle contractions. Eur J Appl Physiol Occup Physiol 75(4):369–374PubMed Brown SJ, Child RB, Day SH, Donnelly AE (1997) Indices of skeletal muscle damage and connective tissue breakdown following eccentric muscle contractions. Eur J Appl Physiol Occup Physiol 75(4):369–374PubMed
go back to reference Clarkson PM, Tremblay I (1988) Exercise-induced muscle damage, repair and adaptation in humans. J Appl Physiol 65(1):1–6PubMed Clarkson PM, Tremblay I (1988) Exercise-induced muscle damage, repair and adaptation in humans. J Appl Physiol 65(1):1–6PubMed
go back to reference Clarkson PM, Nosaka K, Braun B (1992) Muscle function after exercise-induced muscle damage and rapid adaptation. Med Sci Sports Exerc 24(5):512–520PubMed Clarkson PM, Nosaka K, Braun B (1992) Muscle function after exercise-induced muscle damage and rapid adaptation. Med Sci Sports Exerc 24(5):512–520PubMed
go back to reference Dolezal BA, Potteiger JA, Jacobsen DJ, Benedict SH (2000) Muscle damage and resting metabolic rate after acute resistance exercise with an eccentric overload. Med Sci Sports Exerc 32(7):1202–1207PubMed Dolezal BA, Potteiger JA, Jacobsen DJ, Benedict SH (2000) Muscle damage and resting metabolic rate after acute resistance exercise with an eccentric overload. Med Sci Sports Exerc 32(7):1202–1207PubMed
go back to reference Friden J (1984) Changes in human skeletal muscle induced by long-term eccentric exercise. Cell Tissue Res 236(2):365–372PubMed Friden J (1984) Changes in human skeletal muscle induced by long-term eccentric exercise. Cell Tissue Res 236(2):365–372PubMed
go back to reference Friden J, Lieber RL (2001) Eccentric exercise-induced injuries to contractile and cytoskeletal muscle fiber components. Acta Physiol Scand 171:321–326PubMed Friden J, Lieber RL (2001) Eccentric exercise-induced injuries to contractile and cytoskeletal muscle fiber components. Acta Physiol Scand 171:321–326PubMed
go back to reference Hortobagyi T, Houmard J, Fraser D, Dudek R, Lambert J, Tracy J (1998) Normal forces and myofibrillar disruption after repeated eccentric exercise. J Appl Physiol 84(2):492–498PubMed Hortobagyi T, Houmard J, Fraser D, Dudek R, Lambert J, Tracy J (1998) Normal forces and myofibrillar disruption after repeated eccentric exercise. J Appl Physiol 84(2):492–498PubMed
go back to reference Jamurtas AZ, Fatouros IG, Buckenmeyer P, Kokkinidis E, Kambas A, Kyriazis G (2000) Effects of plyometric exercise on muscle soreness and plasma creatine kinase levels and its comparison with eccentric and concentric exercise. J Strength Cond Res 14(1):68–74 Jamurtas AZ, Fatouros IG, Buckenmeyer P, Kokkinidis E, Kambas A, Kyriazis G (2000) Effects of plyometric exercise on muscle soreness and plasma creatine kinase levels and its comparison with eccentric and concentric exercise. J Strength Cond Res 14(1):68–74
go back to reference Jones DA, Newham DJ, Clarkson PM (1987) skeletal muscle stiffness and pain following eccentric exercise of the elbow flexors. Pain 30(2):233–242PubMed Jones DA, Newham DJ, Clarkson PM (1987) skeletal muscle stiffness and pain following eccentric exercise of the elbow flexors. Pain 30(2):233–242PubMed
go back to reference Jones D, Round J, de Haan A (2004) Muscle pain and damage. In: Jones D, Round J, de Haan A (eds) Skeletal muscle from molecules to movement. Churchill and Livingstone, London, pp 135–150 Jones D, Round J, de Haan A (2004) Muscle pain and damage. In: Jones D, Round J, de Haan A (eds) Skeletal muscle from molecules to movement. Churchill and Livingstone, London, pp 135–150
go back to reference Kellis E, Baltzopoulos V (1995) Isokinetic eccentric exercise. Sports Med 19(3):202–222PubMed Kellis E, Baltzopoulos V (1995) Isokinetic eccentric exercise. Sports Med 19(3):202–222PubMed
go back to reference Klein CS, Marsh GD, Petrella RJ, Rice CL (2003) Muscle fiber number in the biceps brachii muscle of young and old men. Muscle Nerve 28(1):62–8PubMed Klein CS, Marsh GD, Petrella RJ, Rice CL (2003) Muscle fiber number in the biceps brachii muscle of young and old men. Muscle Nerve 28(1):62–8PubMed
go back to reference Lee J, Clarkson PM (2003) Plasma creatine kinase activity and glutathione after eccentric exercise. Med Sci Sports Exerc 35(6):930–936PubMed Lee J, Clarkson PM (2003) Plasma creatine kinase activity and glutathione after eccentric exercise. Med Sci Sports Exerc 35(6):930–936PubMed
go back to reference Lieber RL, Friden J (1988) Selective damage of fast glycolytic muscle fibers with eccentric contraction of the rabbit tibialis anterior. Acta Physiol Scand 133:587–588PubMed Lieber RL, Friden J (1988) Selective damage of fast glycolytic muscle fibers with eccentric contraction of the rabbit tibialis anterior. Acta Physiol Scand 133:587–588PubMed
go back to reference McHugh MP (2003) Recent advances in the understanding of the repeated bout effect: the protective effect against muscle damage from a single bout of eccentric exercise. Scand J Med Sci Sports 13(2):88–97PubMed McHugh MP (2003) Recent advances in the understanding of the repeated bout effect: the protective effect against muscle damage from a single bout of eccentric exercise. Scand J Med Sci Sports 13(2):88–97PubMed
go back to reference Mense S, Schmidt RF (1977) Muscle pain: which receptors are responsible for the transmission of noxious stimuli? In: Rose FC (ed) Physiological aspects of Clinical Neurology. Blackwell, Oxford, pp 265–278 Mense S, Schmidt RF (1977) Muscle pain: which receptors are responsible for the transmission of noxious stimuli? In: Rose FC (ed) Physiological aspects of Clinical Neurology. Blackwell, Oxford, pp 265–278
go back to reference Newham DJ, Jones DA, Ghosh G, Aurora P (1988) Muscle fatigue and pain after eccentric contractions at long and short length. Clin Sci (Lond) 74(5):553–557 Newham DJ, Jones DA, Ghosh G, Aurora P (1988) Muscle fatigue and pain after eccentric contractions at long and short length. Clin Sci (Lond) 74(5):553–557
go back to reference Nosaka K, Clarkson PM (1995) Muscle damage following repeated bouts of high force eccentric exercise. Med Sci Sports Exerc 27(9):1263–1269PubMed Nosaka K, Clarkson PM (1995) Muscle damage following repeated bouts of high force eccentric exercise. Med Sci Sports Exerc 27(9):1263–1269PubMed
go back to reference Nosaka K, Newton M (2002) Difference in the magnitude of muscle damage between maximal and submaximal eccentric loading. J Strength Cond Res 16(2):202–208PubMed Nosaka K, Newton M (2002) Difference in the magnitude of muscle damage between maximal and submaximal eccentric loading. J Strength Cond Res 16(2):202–208PubMed
go back to reference Nosaka K, Clarkson PM, McGuiggin ME, Byrne JM (1991) Time course of muscle adaptation after high force eccentric exercise. Eur J Appl Physiol 63:70–76 Nosaka K, Clarkson PM, McGuiggin ME, Byrne JM (1991) Time course of muscle adaptation after high force eccentric exercise. Eur J Appl Physiol 63:70–76
go back to reference Nosaka K, Sakamoto K, Newton M, Sacco P (2001) The repeated bout effect of reduced-load eccentric exercise on elbow flexor muscle damage. Eur J Appl Physiol 85(1–2):34–40PubMed Nosaka K, Sakamoto K, Newton M, Sacco P (2001) The repeated bout effect of reduced-load eccentric exercise on elbow flexor muscle damage. Eur J Appl Physiol 85(1–2):34–40PubMed
go back to reference Nosaka K, Newton M, Sacco P (2002) Delayed-onset muscle soreness does not reflect the magnitude of eccentric exercise-induced muscle damage. Scand J Med Sci Sports 12(6):337–346PubMed Nosaka K, Newton M, Sacco P (2002) Delayed-onset muscle soreness does not reflect the magnitude of eccentric exercise-induced muscle damage. Scand J Med Sci Sports 12(6):337–346PubMed
go back to reference Paddon-Jones D, Abernethy PJ (2001) Acute adaptation to low volume eccentric exercise. Med Sci Sports Exerc 33(7):1213–1219PubMed Paddon-Jones D, Abernethy PJ (2001) Acute adaptation to low volume eccentric exercise. Med Sci Sports Exerc 33(7):1213–1219PubMed
go back to reference Prou E, Guevel A, Benezet P, Marini JF (1999) Exercise-induced muscle damage: absence of adaptive effect after a single session of eccentric isokinetic heavy resistance exercise. J Sports Med Phys Fitness 39(3):226–232PubMed Prou E, Guevel A, Benezet P, Marini JF (1999) Exercise-induced muscle damage: absence of adaptive effect after a single session of eccentric isokinetic heavy resistance exercise. J Sports Med Phys Fitness 39(3):226–232PubMed
go back to reference Sorichter S, Mair J, Koller A, Calzolari C, Huonker M, Pau B, Puschendorf B (2001). Release of muscle proteins after downhill running in male and female subjects. Scand J Med Sci Sports 11(1):28–32PubMed Sorichter S, Mair J, Koller A, Calzolari C, Huonker M, Pau B, Puschendorf B (2001). Release of muscle proteins after downhill running in male and female subjects. Scand J Med Sci Sports 11(1):28–32PubMed
go back to reference Thomas JR, Nelson JK (1996) Research methods in physical activity. Human Kinetics, Champaign, pp 194–211 Thomas JR, Nelson JK (1996) Research methods in physical activity. Human Kinetics, Champaign, pp 194–211
go back to reference Travnik L, Pernus F, Erzen I (1995) Histochemical and morphometric characteristics of the normal human vastus medialis longus and vastus medialis obliquus muscles. J Anat 187(2):403–411PubMed Travnik L, Pernus F, Erzen I (1995) Histochemical and morphometric characteristics of the normal human vastus medialis longus and vastus medialis obliquus muscles. J Anat 187(2):403–411PubMed
go back to reference Warren GL, Lowe DA, Arnstrong RB (1999) Measurement tools used in the study of eccentric contraction-induced injury. Sports Med 27(1):43–59PubMed Warren GL, Lowe DA, Arnstrong RB (1999) Measurement tools used in the study of eccentric contraction-induced injury. Sports Med 27(1):43–59PubMed
Metadata
Title
Comparison between leg and arm eccentric exercises of the same relative intensity on indices of muscle damage
Authors
Athanasios Z. Jamurtas
V. Theocharis
T. Tofas
A. Tsiokanos
C. Yfanti
V. Paschalis
Y. Koutedakis
K. Nosaka
Publication date
01-10-2005
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 2-3/2005
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-005-1345-0

Other articles of this Issue 2-3/2005

European Journal of Applied Physiology 2-3/2005 Go to the issue