Skip to main content
Top
Published in: International Archives of Occupational and Environmental Health 9/2009

01-10-2009 | Original Article

Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration

Authors: Alexandra J. L. Thompson, Michael J. Griffin

Published in: International Archives of Occupational and Environmental Health | Issue 9/2009

Login to get access

Abstract

Background

Acute exposures of the hand to vibration result in changes in finger blood flow, but it is not clear how the changes depend on the characteristics of the vibration.

Objectives

To determine the effects of the magnitude and frequency of hand-transmitted vibration on finger blood flow in an exposed and a non-exposed hand during and after exposure to vibration.

Methods

Twelve persons attended seven sessions consisting of five successive periods: (1) no force and no vibration, (2) force and no vibration, (3) force and vibration, (4) force and no vibration, and (5) no force and no vibration. During the second, third and fourth periods, the palm of the right hand applied a 2-N downward force on a 25-mm diameter convex platform. During the third period, the platform was vibrated at either 16, 31.5, 63, 125, 250, or 315 Hz with the vibration magnitude increasing linearly from 0 to 15 ms−2 rms (frequency-weighted) over 30 min (0–11 ms−2 rms at 315 Hz). Finger blood flow was measured in the middle and little fingers of the right (exposed) hand and the middle finger of the left (unexposed) hand.

Results

The application of 2-N force by the palm did not affect finger blood flow on either the exposed hand or the unexposed hand. Blood flow in all three fingers (both exposed and not exposed to vibration) reduced similarly with increasing vibration magnitude, with the greatest reduction to about 40% of finger blood flow before vibration exposure. During vibration at the same frequency-weighted acceleration according to current standards, finger blood flow was dependent on the vibration frequency, with vibration at 125, 250 and 315 Hz causing the greatest reductions in finger blood flow. With vibration at 250 Hz and 315 Hz, frequency-weighted accelerations less than 1.0 ms−2 rms reduced finger blood flow, whereas greater magnitudes were required at the lower frequencies. After the cessation of vibration, finger blood flow in exposed and unexposed fingers also depended on the vibration frequency, with greater vasoconstriction after exposure to the higher frequencies.

Conclusions

During exposure to vibration, vasoconstriction in the fingers depends on both the frequency and the magnitude of the vibration. Finger blood flow was reduced by vibration magnitudes much lower than those on many powered hand tools. Vibration of one hand produced a similar vasoconstriction in fingers on the exposed and unexposed hand, suggesting a centrally mediated response. After cessation of vibration, there is continued vasoconstriction that depends on the frequency and magnitude of the prior vibration, with a similar effect in exposed and non-exposed hands.
Literature
go back to reference Bovenzi M, Italian Study Group on Physical Hazards in the Stone Industry (1994) Hand-arm vibration syndrome and dose response relationship for vibration-induced white finger among quarry drillers and stonecarvers. Occup Environ Med 51:603–611. doi:10.1136/oem.51.9.603 PubMedCrossRef Bovenzi M, Italian Study Group on Physical Hazards in the Stone Industry (1994) Hand-arm vibration syndrome and dose response relationship for vibration-induced white finger among quarry drillers and stonecarvers. Occup Environ Med 51:603–611. doi:10.​1136/​oem.​51.​9.​603 PubMedCrossRef
go back to reference Bovenzi M, Franzinelli A, Mancini R, Cannava MG, Maiorano M, Ceccarelli F (1995) Dose–response relation for vascular disorders induced by vibration in the fingers of forestry workers. Occup Environ Med 52:722–730. doi:10.1136/oem.52.11.722 PubMedCrossRef Bovenzi M, Franzinelli A, Mancini R, Cannava MG, Maiorano M, Ceccarelli F (1995) Dose–response relation for vascular disorders induced by vibration in the fingers of forestry workers. Occup Environ Med 52:722–730. doi:10.​1136/​oem.​52.​11.​722 PubMedCrossRef
go back to reference Bovenzi M, Lindsell CJ, Griffin MJ (1998) Duration of acute exposure to vibration and finger circulation. Scand J Work Environ Health 24(2):130–137PubMed Bovenzi M, Lindsell CJ, Griffin MJ (1998) Duration of acute exposure to vibration and finger circulation. Scand J Work Environ Health 24(2):130–137PubMed
go back to reference Bovenzi M, Lindsell CJ, Griffin MJ (1999) Magnitude of acute exposure to vibration and finger circulation. Scand J Work Environ Health 25(3):278–284PubMed Bovenzi M, Lindsell CJ, Griffin MJ (1999) Magnitude of acute exposure to vibration and finger circulation. Scand J Work Environ Health 25(3):278–284PubMed
go back to reference Greenfield ADM, Whitney RJ, Mowbray JF (1963) Methods for the investigation of peripheral blood flow. Br Med Bull 19:101–109PubMed Greenfield ADM, Whitney RJ, Mowbray JF (1963) Methods for the investigation of peripheral blood flow. Br Med Bull 19:101–109PubMed
go back to reference Griffin MJ, Welsh AJL, Bovenzi M (2006) Acute response of finger circulation to force and vibration applied at the palm of the hand. Scand J Work Environ Health 32(5):383–391PubMed Griffin MJ, Welsh AJL, Bovenzi M (2006) Acute response of finger circulation to force and vibration applied at the palm of the hand. Scand J Work Environ Health 32(5):383–391PubMed
go back to reference International Organization for Standardization (2001) Mechanical vibration—guidelines for the measurement and the assessment of human exposure to hand-transmitted vibration. Geneva, ISO, 2001, ISO 5349 International Organization for Standardization (2001) Mechanical vibration—guidelines for the measurement and the assessment of human exposure to hand-transmitted vibration. Geneva, ISO, 2001, ISO 5349
go back to reference Nohara S, Okamoto K, Okada A (1986) Peripheral circulatory and nervous response to various frequencies of local vibration exposure. Scand J Work Environ Health 12:382–384 Nohara S, Okamoto K, Okada A (1986) Peripheral circulatory and nervous response to various frequencies of local vibration exposure. Scand J Work Environ Health 12:382–384
go back to reference Welsh AJL (2003) The effects of push force and vibration magnitude on finger blood flow. Presented at the 38th UK group meeting of human response to vibration, Institute of Naval Medicine, Gosport, Hampshire, 17–19 September 2003 Welsh AJL (2003) The effects of push force and vibration magnitude on finger blood flow. Presented at the 38th UK group meeting of human response to vibration, Institute of Naval Medicine, Gosport, Hampshire, 17–19 September 2003
go back to reference Welsh AJL, Griffin MJ (2004) Effect of vibration magnitude and push force on finger blood flow. Presented at the 10th hand-arm vibration syndrome conference, Las Vegas, 5–9 June 2004 Welsh AJL, Griffin MJ (2004) Effect of vibration magnitude and push force on finger blood flow. Presented at the 10th hand-arm vibration syndrome conference, Las Vegas, 5–9 June 2004
Metadata
Title
Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration
Authors
Alexandra J. L. Thompson
Michael J. Griffin
Publication date
01-10-2009
Publisher
Springer-Verlag
Published in
International Archives of Occupational and Environmental Health / Issue 9/2009
Print ISSN: 0340-0131
Electronic ISSN: 1432-1246
DOI
https://doi.org/10.1007/s00420-009-0413-x

Other articles of this Issue 9/2009