Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 10/2016

01-10-2016 | Cataract

Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position

Authors: Youngsub Eom, Dongok Ryu, Dae Wook Kim, Seul Ki Yang, Jong Suk Song, Sug-Whan Kim, Hyo Myung Kim

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 10/2016

Login to get access

Abstract

Background

To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP).

Methods

Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results.

Results

The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation.

Conclusions

The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
Appendix
Available only for authorised users
Literature
1.
go back to reference Visser N, Bauer NJ, Nuijts RM (2013) Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg 39:624–637CrossRefPubMed Visser N, Bauer NJ, Nuijts RM (2013) Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg 39:624–637CrossRefPubMed
2.
go back to reference Eom Y, Nam KT, Kang SY, Kim HM, Song JS (2013) Axis difference between corneal and internal astigmatism to consider for toric intraocular lenses. Am J Ophthalmol 156:1112–1119CrossRefPubMed Eom Y, Nam KT, Kang SY, Kim HM, Song JS (2013) Axis difference between corneal and internal astigmatism to consider for toric intraocular lenses. Am J Ophthalmol 156:1112–1119CrossRefPubMed
3.
go back to reference Eom Y, Song JS, Kim YY, Kim HM (2015) Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with toric intraocular lenses. J Cataract Refract Surg 41:1650–1657CrossRefPubMed Eom Y, Song JS, Kim YY, Kim HM (2015) Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with toric intraocular lenses. J Cataract Refract Surg 41:1650–1657CrossRefPubMed
5.
go back to reference Weinand F, Jung A, Stein A, Pfutzner A, Becker R, Pavlovic S (2007) Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control. J Cataract Refract Surg 33:800–803CrossRefPubMed Weinand F, Jung A, Stein A, Pfutzner A, Becker R, Pavlovic S (2007) Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control. J Cataract Refract Surg 33:800–803CrossRefPubMed
6.
go back to reference Savini G, Naeser K (2015) An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci 56:827–835CrossRefPubMed Savini G, Naeser K (2015) An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci 56:827–835CrossRefPubMed
7.
go back to reference Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L (2012) Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg 38:2080–2087CrossRefPubMed Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L (2012) Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg 38:2080–2087CrossRefPubMed
8.
go back to reference Eom Y, Kang SY, Kim HM, Song JS (2014) The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements. Graefes Arch Clin Exp Ophthalmol 252:1769–1777CrossRefPubMed Eom Y, Kang SY, Kim HM, Song JS (2014) The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements. Graefes Arch Clin Exp Ophthalmol 252:1769–1777CrossRefPubMed
9.
go back to reference Nemeth G, Berta A, Szalai E, Hassan Z, Modis L Jr (2014) Analysis of surgically induced astigmatism on the posterior surface of the cornea. J Refract Surg 30:604–608CrossRefPubMed Nemeth G, Berta A, Szalai E, Hassan Z, Modis L Jr (2014) Analysis of surgically induced astigmatism on the posterior surface of the cornea. J Refract Surg 30:604–608CrossRefPubMed
10.
go back to reference Goggin M, Moore S, Esterman A (2011) Outcome of toric intraocular lens implantation after adjusting for anterior chamber depth and intraocular lens sphere equivalent power effects. Arch Ophthalmol 129:998–1003CrossRefPubMed Goggin M, Moore S, Esterman A (2011) Outcome of toric intraocular lens implantation after adjusting for anterior chamber depth and intraocular lens sphere equivalent power effects. Arch Ophthalmol 129:998–1003CrossRefPubMed
11.
go back to reference Eom Y, Kang SY, Song JS, Kim YY, Kim HM (2015) Effect of effective lens position on cylinder power of toric intraocular lenses. Can J Ophthalmol 50:26–32CrossRefPubMed Eom Y, Kang SY, Song JS, Kim YY, Kim HM (2015) Effect of effective lens position on cylinder power of toric intraocular lenses. Can J Ophthalmol 50:26–32CrossRefPubMed
12.
go back to reference Eom Y, Rhim JW, Kang SY, Kim SW, Song JS, Kim HM (2015) Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power. Am J Ophthalmol 160:717–724, e712CrossRefPubMed Eom Y, Rhim JW, Kang SY, Kim SW, Song JS, Kim HM (2015) Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power. Am J Ophthalmol 160:717–724, e712CrossRefPubMed
13.
go back to reference Alpins NA (1997) New method of targeting vectors to treat astigmatism. J Cataract Refract Surg 23:65–75CrossRefPubMed Alpins NA (1997) New method of targeting vectors to treat astigmatism. J Cataract Refract Surg 23:65–75CrossRefPubMed
14.
15.
go back to reference Naeser K (2008) Assessment and statistics of surgically induced astigmatism. Acta Ophthalmol 86(Suppl 1):5–28PubMed Naeser K (2008) Assessment and statistics of surgically induced astigmatism. Acta Ophthalmol 86(Suppl 1):5–28PubMed
16.
17.
go back to reference Savini G, Hoffer KJ, Carbonelli M, Ducoli P, Barboni P (2013) Influence of axial length and corneal power on the astigmatic power of toric intraocular lenses. J Cataract Refract Surg 39:1900–1903CrossRefPubMed Savini G, Hoffer KJ, Carbonelli M, Ducoli P, Barboni P (2013) Influence of axial length and corneal power on the astigmatic power of toric intraocular lenses. J Cataract Refract Surg 39:1900–1903CrossRefPubMed
18.
go back to reference Holladay JT (1993) Refractive power calculations for intraocular lenses in the phakic eye. Am J Ophthalmol 116:63–66CrossRefPubMed Holladay JT (1993) Refractive power calculations for intraocular lenses in the phakic eye. Am J Ophthalmol 116:63–66CrossRefPubMed
19.
go back to reference Holladay JT (1997) Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg 23:1356–1370CrossRefPubMed Holladay JT (1997) Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg 23:1356–1370CrossRefPubMed
20.
go back to reference Haigis W (2004) The Haigis formula. In: Shammas HJ (ed) Intraocular lens power calculations. Slack, Thorofare, NJ, pp 41–57 Haigis W (2004) The Haigis formula. In: Shammas HJ (ed) Intraocular lens power calculations. Slack, Thorofare, NJ, pp 41–57
21.
go back to reference Hoffer KJ (1993) The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19:700–712CrossRefPubMed Hoffer KJ (1993) The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19:700–712CrossRefPubMed
22.
go back to reference Zuberbuhler B, Morrell AJ (2007) Errata in printed Hoffer Q formula. J Cataract Refract Surg 33(2):2, author reply 2-3CrossRefPubMed Zuberbuhler B, Morrell AJ (2007) Errata in printed Hoffer Q formula. J Cataract Refract Surg 33(2):2, author reply 2-3CrossRefPubMed
23.
go back to reference Retzlaff JA, Sanders DR, Kraff MC (1990) Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 16:333–340CrossRefPubMed Retzlaff JA, Sanders DR, Kraff MC (1990) Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 16:333–340CrossRefPubMed
24.
go back to reference Haigis W (1993) Occurrence of erroneous anterior chamber depth in the SRK/T formula. J Cataract Refract Surg 19:442–446CrossRefPubMed Haigis W (1993) Occurrence of erroneous anterior chamber depth in the SRK/T formula. J Cataract Refract Surg 19:442–446CrossRefPubMed
25.
go back to reference Eom Y, Song JS, Kim HM (2016) Spectacle plane add power of the multifocal intraocular lenses according to effective lens position. Can J Ophthalmol [Article in Press] Eom Y, Song JS, Kim HM (2016) Spectacle plane add power of the multifocal intraocular lenses according to effective lens position. Can J Ophthalmol [Article in Press]
26.
go back to reference Greivenkamp JE, Schwiegerling J, Miller JM, Mellinger MD (1995) Visual acuity modeling using optical raytracing of schematic eyes. Am J Ophthalmol 120:227–240CrossRefPubMed Greivenkamp JE, Schwiegerling J, Miller JM, Mellinger MD (1995) Visual acuity modeling using optical raytracing of schematic eyes. Am J Ophthalmol 120:227–240CrossRefPubMed
27.
go back to reference DeHoog E, Doraiswamy A (2014) Evaluation of the impact of light scatter from glistenings in pseudophakic eyes. J Cataract Refract Surg 40:95–103CrossRefPubMed DeHoog E, Doraiswamy A (2014) Evaluation of the impact of light scatter from glistenings in pseudophakic eyes. J Cataract Refract Surg 40:95–103CrossRefPubMed
28.
go back to reference Cheng LS, Tsai CY, Tsai RJ, Liou SW, Ho JD (2011) Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement. Acta Ophthalmol 89:417–422CrossRefPubMed Cheng LS, Tsai CY, Tsai RJ, Liou SW, Ho JD (2011) Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement. Acta Ophthalmol 89:417–422CrossRefPubMed
29.
go back to reference Eom Y, Kang SY, Song JS, Kim YY, Kim HM (2014) Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes. Am J Ophthalmol 157:818–824, e812CrossRefPubMed Eom Y, Kang SY, Song JS, Kim YY, Kim HM (2014) Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes. Am J Ophthalmol 157:818–824, e812CrossRefPubMed
30.
go back to reference Olsen T, Thim K, Corydon L (1991) Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg 17:187–193CrossRefPubMed Olsen T, Thim K, Corydon L (1991) Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg 17:187–193CrossRefPubMed
31.
go back to reference Waltz KL, Featherstone K, Tsai L, Trentacost D (2014) Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism. Ophthalmology 122:39–47CrossRefPubMed Waltz KL, Featherstone K, Tsai L, Trentacost D (2014) Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism. Ophthalmology 122:39–47CrossRefPubMed
32.
go back to reference Hirnschall N, Maedel S, Weber M, Findl O (2014) Rotational stability of a single-piece toric acrylic intraocular lens: a pilot study. Am J Ophthalmol 157:405–411, e401CrossRefPubMed Hirnschall N, Maedel S, Weber M, Findl O (2014) Rotational stability of a single-piece toric acrylic intraocular lens: a pilot study. Am J Ophthalmol 157:405–411, e401CrossRefPubMed
33.
go back to reference Visser N, Berendschot TT, Verbakel F, de Brabander J, Nuijts RM (2012) Comparability and repeatability of corneal astigmatism measurements using different measurement technologies. J Cataract Refract Surg 38:1764–1770CrossRefPubMed Visser N, Berendschot TT, Verbakel F, de Brabander J, Nuijts RM (2012) Comparability and repeatability of corneal astigmatism measurements using different measurement technologies. J Cataract Refract Surg 38:1764–1770CrossRefPubMed
34.
go back to reference Yong Park C, Do JR, Chuck RS (2012) Predicting postoperative astigmatism using Scheimpflug keratometry (Pentacam) and automated keratometry (IOLMaster). Curr Eye Res 37:1091–1098CrossRefPubMed Yong Park C, Do JR, Chuck RS (2012) Predicting postoperative astigmatism using Scheimpflug keratometry (Pentacam) and automated keratometry (IOLMaster). Curr Eye Res 37:1091–1098CrossRefPubMed
35.
go back to reference Abulafia A, Hill WE, Franchina M, Barrett GD (2015) Comparison of methods to predict residual astigmatism after intraocular lens implantation. J Refract Surg 31:699–707CrossRefPubMed Abulafia A, Hill WE, Franchina M, Barrett GD (2015) Comparison of methods to predict residual astigmatism after intraocular lens implantation. J Refract Surg 31:699–707CrossRefPubMed
36.
go back to reference Tejedor J, Guirao A (2013) Agreement between refractive and corneal astigmatism in pseudophakic eyes. Cornea 32:783–790CrossRefPubMed Tejedor J, Guirao A (2013) Agreement between refractive and corneal astigmatism in pseudophakic eyes. Cornea 32:783–790CrossRefPubMed
Metadata
Title
Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
Authors
Youngsub Eom
Dongok Ryu
Dae Wook Kim
Seul Ki Yang
Jong Suk Song
Sug-Whan Kim
Hyo Myung Kim
Publication date
01-10-2016
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 10/2016
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-016-3446-3

Other articles of this Issue 10/2016

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2016 Go to the issue