Skip to main content
Top
Published in: Journal of Neurology 9/2006

01-09-2006 | REVIEW

Neuronavigation and surgery of intracerebral tumours

Authors: P.W.A. Willems, J.W. Berkelbach van der Sprenkel, C.A.F. Tulleken, M.A. Viergever, M.J.B. Taphoorn

Published in: Journal of Neurology | Issue 9/2006

Login to get access

Abstract

Approximately four decades after the successful clinical introduction of framebased stereotactic neurosurgery by Spiegel and Wycis, frameless stereotaxy emerged to enable more elaborate image guidance in open neurosurgical procedures. Frameless stereotaxy, or neuronavigation, relies on one of several different localizing techniques to determine the position of an operative instrument relative to the surgical field, without the need for a coordinate frame rigidly fixed to the patients’ skull. Currently, most systems are based on the optical triangulation of infrared light sources fixed to the surgical instrument.
In its essence, a navigation system is a three-dimensional digitiser that correlates its measurements to a reference data set, i.e. a preoperatively acquired CT or MRI image stack. This correlation is achieved through a patient-to-image registration procedure resulting in a mathematical transformation matrix mapping each position in ‘world space’ onto ‘image space’. Thus, throughout the remainder of the surgical procedure, the position of the surgical instrument can be demonstrated on a computer screen, relative to the CT or MRI images.
Though neuronavigation has become a routinely used addition to the neurosurgical armamentarium, its impact on surgical results has not yet been examined sufficiently. Therefore, the surgeon is left to decide on a case-by-case basis whether to perform surgery with or without neuronavigation. Future challenges lie in improvement of the interface between the surgeon and the neuronavigator and in reducing the brainshift error, i.e. inaccuracy introduced by changes in tissue positions after image acquisition.
Literature
1.
go back to reference Altukhov NV (1891) Encephalometric investigations of the brain relative to the sex, age and skull indexes. Moscow Altukhov NV (1891) Encephalometric investigations of the brain relative to the sex, age and skull indexes. Moscow
2.
go back to reference Apuzzo ML, Chandrasoma PT, Cohen D, Zee CS, Zelman V (1987) Computed imaging stereotaxy: experience and perspective related to 500 procedures applied to brain masses. Neurosurgery 20: 930–937PubMed Apuzzo ML, Chandrasoma PT, Cohen D, Zee CS, Zelman V (1987) Computed imaging stereotaxy: experience and perspective related to 500 procedures applied to brain masses. Neurosurgery 20: 930–937PubMed
3.
go back to reference Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Intraoperative localization using an armless, frameless stereotactic wand. Technical note J Neurosurg 78: 510–514PubMed Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Intraoperative localization using an armless, frameless stereotactic wand. Technical note J Neurosurg 78: 510–514PubMed
4.
go back to reference Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Use of a frameless, armless stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging Neurosurgery 33: 674–678PubMed Barnett GH, Kormos DW, Steiner CP, Weisenberger J (1993) Use of a frameless, armless stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging Neurosurgery 33: 674–678PubMed
5.
go back to reference Berger MS (1996) The impact of technical adjuncts in the surgical management of cerebral hemispheric low-grade gliomas of childhood J Neurooncol 28(2–3): 129–155PubMed Berger MS (1996) The impact of technical adjuncts in the surgical management of cerebral hemispheric low-grade gliomas of childhood J Neurooncol 28(2–3): 129–155PubMed
6.
go back to reference Bergstrom M, Greitz J (1976) Stereotaxic computed tomography AJR 127: 167–170PubMed Bergstrom M, Greitz J (1976) Stereotaxic computed tomography AJR 127: 167–170PubMed
7.
go back to reference Black PM, Alexander E III, Martin C, Moriarty T, Nabavi A, Wong TZ, Schwartz RB, Jolesz F (1999) Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit Neurosurgery 45: 423–431PubMedCrossRef Black PM, Alexander E III, Martin C, Moriarty T, Nabavi A, Wong TZ, Schwartz RB, Jolesz F (1999) Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit Neurosurgery 45: 423–431PubMedCrossRef
8.
go back to reference Black PM, Moriarty T, Alexander E, Stieg P, Woodard EJ, Gleason PL, Martin CH, Kikinis R, Schwartz RB, Jolesz FA (1997) Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications Neurosurgery 41: 831–842PubMedCrossRef Black PM, Moriarty T, Alexander E, Stieg P, Woodard EJ, Gleason PL, Martin CH, Kikinis R, Schwartz RB, Jolesz FA (1997) Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications Neurosurgery 41: 831–842PubMedCrossRef
9.
go back to reference Bohinski RJ, Kokkino AK, Warnick RE, Gaskill-Shipley MF, Kormos DW, Lukin RR, Tew JM (2001) Glioma resection in a shared-resource magnetic resonance operating room after optimal image-guided frameless stereotactic resection Neurosurgery 48: 731–742PubMedCrossRef Bohinski RJ, Kokkino AK, Warnick RE, Gaskill-Shipley MF, Kormos DW, Lukin RR, Tew JM (2001) Glioma resection in a shared-resource magnetic resonance operating room after optimal image-guided frameless stereotactic resection Neurosurgery 48: 731–742PubMedCrossRef
10.
go back to reference Bourgeois G, Magnin M, Morel A, Sartoretti S, Huisman T, Tuncdogan E, Meier D, Jeanmonod D (1999) Accuracy of MRI-guided stereotactic thalamic functional neurosurgery Neuroradiology 41: 636–645PubMedCrossRef Bourgeois G, Magnin M, Morel A, Sartoretti S, Huisman T, Tuncdogan E, Meier D, Jeanmonod D (1999) Accuracy of MRI-guided stereotactic thalamic functional neurosurgery Neuroradiology 41: 636–645PubMedCrossRef
11.
go back to reference Brown RA (1979) A stereotactic head frame for use with CT body scanners Invest Radiol 14(4): 300–304PubMedCrossRef Brown RA (1979) A stereotactic head frame for use with CT body scanners Invest Radiol 14(4): 300–304PubMedCrossRef
12.
go back to reference Burchiel KJ, Nguyen TT, Coombs BD, Szumoski J (1996) MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames Stereotact Funct Neurosurg 66: 123–136PubMed Burchiel KJ, Nguyen TT, Coombs BD, Szumoski J (1996) MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames Stereotact Funct Neurosurg 66: 123–136PubMed
13.
go back to reference Carney AS, Patel N, Baldwin DL, Coakham HB, Sandeman DR (1996) Intra-operative image guidance in otolaryngology–the use of the ISG viewing wand J Laryngol Otol 110: 322–327PubMed Carney AS, Patel N, Baldwin DL, Coakham HB, Sandeman DR (1996) Intra-operative image guidance in otolaryngology–the use of the ISG viewing wand J Laryngol Otol 110: 322–327PubMed
14.
go back to reference Clarke RH, Horsley RV (1906) On a method of investigating the deep ganglia and tracts of the central nervous system (cerebellum) BMJ 2: 1799–1800 Clarke RH, Horsley RV (1906) On a method of investigating the deep ganglia and tracts of the central nervous system (cerebellum) BMJ 2: 1799–1800
15.
go back to reference Couldwell WT, Apuzzo ML (1990) Initial experience related to the use of the Cosman-Roberts-Wells stereotactic instrument. Technical note J Neurosurg 72: 145–148PubMed Couldwell WT, Apuzzo ML (1990) Initial experience related to the use of the Cosman-Roberts-Wells stereotactic instrument. Technical note J Neurosurg 72: 145–148PubMed
16.
go back to reference Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DG (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note J Neurosurg 90: 160–168PubMed Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DG (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note J Neurosurg 90: 160–168PubMed
17.
go back to reference Dorward NL, Alberti O, Velani B, Gerritsen FA, Harkness WF, Kitchen ND, Thomas DG (1998) Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation J Neurosurg 88: 656–662PubMed Dorward NL, Alberti O, Velani B, Gerritsen FA, Harkness WF, Kitchen ND, Thomas DG (1998) Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation J Neurosurg 88: 656–662PubMed
18.
go back to reference Doshi PK, Lemmieux L, Fish DR, Shorvon SD, Harkness WH, Thomas DG (1995) Frameless stereotaxy and interactive neurosurgery with the ISG viewing wand Acta Neurochir Suppl (Wien ) 64: 49–53 Doshi PK, Lemmieux L, Fish DR, Shorvon SD, Harkness WH, Thomas DG (1995) Frameless stereotaxy and interactive neurosurgery with the ISG viewing wand Acta Neurochir Suppl (Wien ) 64: 49–53
19.
go back to reference Ferrant M, Nabavi A, Macq B, Black PM, Jolesz FA, Kikinis R, Warfield SK (2002) Serial registration of intraoperative MR images of the brain Med Image Anal 6: 337–359PubMedCrossRef Ferrant M, Nabavi A, Macq B, Black PM, Jolesz FA, Kikinis R, Warfield SK (2002) Serial registration of intraoperative MR images of the brain Med Image Anal 6: 337–359PubMedCrossRef
20.
go back to reference Freysinger W, Gunkel AR, Bale R, Vogele M, Kremser C, Schon G, Thumfart WF (1998) Three-dimensional navigation in otorhinolaryngological surgery with the viewing wand Ann Otol Rhinol Laryngol 107(11 Pt 1): 953–958PubMed Freysinger W, Gunkel AR, Bale R, Vogele M, Kremser C, Schon G, Thumfart WF (1998) Three-dimensional navigation in otorhinolaryngological surgery with the viewing wand Ann Otol Rhinol Laryngol 107(11 Pt 1): 953–958PubMed
21.
go back to reference Galloway RLJ, Maciunas RJ (93) An articulated arm for neurosurgical use. In: Maciunas RJ (ed) Interactive Image-Guided Surgery. American Association of Neurological Surgeons, pp 159–168 Galloway RLJ, Maciunas RJ (93) An articulated arm for neurosurgical use. In: Maciunas RJ (ed) Interactive Image-Guided Surgery. American Association of Neurological Surgeons, pp 159–168
22.
go back to reference Germano IM, Villalobos H, Silvers A, Post KD (1999) Clinical use of the optical digitizer for intracranial neuronavigation Neurosurgery 45: 261–269PubMedCrossRef Germano IM, Villalobos H, Silvers A, Post KD (1999) Clinical use of the optical digitizer for intracranial neuronavigation Neurosurgery 45: 261–269PubMedCrossRef
23.
go back to reference Gildenberg PL (82) Computerized tomography and stereotactic surgery. In: Spiegel EA (ed) Guided Brain Operations. Karger, Basel, pp 24–34 Gildenberg PL (82) Computerized tomography and stereotactic surgery. In: Spiegel EA (ed) Guided Brain Operations. Karger, Basel, pp 24–34
24.
go back to reference Gildenberg PL (1987) Whatever happened to stereotactic surgery? Neurosurgery 20(6): 983–987PubMed Gildenberg PL (1987) Whatever happened to stereotactic surgery? Neurosurgery 20(6): 983–987PubMed
25.
go back to reference Gildenberg PL, Franklin PO (1985) Survey of CT-guided stereotactic surgery Appl Neurophysiol 48: 477–480PubMed Gildenberg PL, Franklin PO (1985) Survey of CT-guided stereotactic surgery Appl Neurophysiol 48: 477–480PubMed
26.
go back to reference Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases J Neurosurg 83: 197–205PubMed Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases J Neurosurg 83: 197–205PubMed
27.
go back to reference Gronningsaeter A, Kleven A, Ommedal S, Aarseth TE, Lie T, Lindseth F, Lango T, Unsgard G (2000) SonoWand, an ultrasound-based neuronavigation system Neurosurgery 47: 1373–1379PubMedCrossRef Gronningsaeter A, Kleven A, Ommedal S, Aarseth TE, Lie T, Lindseth F, Lango T, Unsgard G (2000) SonoWand, an ultrasound-based neuronavigation system Neurosurgery 47: 1373–1379PubMedCrossRef
28.
go back to reference Grunert P, Muller-Forell W, Darabi K, Reisch R, Busert C, Hopf N, Perneczky A (1998) Basic principles and clinical applications of neuronavigation and intraoperative computed tomography Comput Aided Surg 3(4): 166–173PubMedCrossRef Grunert P, Muller-Forell W, Darabi K, Reisch R, Busert C, Hopf N, Perneczky A (1998) Basic principles and clinical applications of neuronavigation and intraoperative computed tomography Comput Aided Surg 3(4): 166–173PubMedCrossRef
29.
go back to reference Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab VectorVision Neuronavigation System: technology and clinical experiences in 131 cases Neurosurgery 44: 97–104PubMedCrossRef Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab VectorVision Neuronavigation System: technology and clinical experiences in 131 cases Neurosurgery 44: 97–104PubMedCrossRef
30.
go back to reference Hadani M, Spiegelman R, Feldman Z, Berkenstadt H, Ram Z (2001) Novel, compact, intraoperative magnetic resonance imaging-guided system for conventional neurosurgical operating rooms Neurosurgery 48: 799–809PubMedCrossRef Hadani M, Spiegelman R, Feldman Z, Berkenstadt H, Ram Z (2001) Novel, compact, intraoperative magnetic resonance imaging-guided system for conventional neurosurgical operating rooms Neurosurgery 48: 799–809PubMedCrossRef
31.
go back to reference Hall WA (1998) The safety and efficacy of stereotactic biopsy for intracranial lesions Cancer 82: 1749–1755PubMedCrossRef Hall WA (1998) The safety and efficacy of stereotactic biopsy for intracranial lesions Cancer 82: 1749–1755PubMedCrossRef
32.
go back to reference Hata N, Dohi T, Iseki H, Takakura K (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration Neurosurgery 41: 608–613PubMedCrossRef Hata N, Dohi T, Iseki H, Takakura K (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration Neurosurgery 41: 608–613PubMedCrossRef
33.
go back to reference Hecaen H, Talairach J, David M, Dell MD (1949) Coagulation limitées du thalamus dans les algies du syndrome thalamique Rev Neurol (Paris) 81: 917–931 Hecaen H, Talairach J, David M, Dell MD (1949) Coagulation limitées du thalamus dans les algies du syndrome thalamique Rev Neurol (Paris) 81: 917–931
34.
go back to reference Heilbrun MP, Roberts TS, Apuzzo ML, Wells THJ, Sabshin JK (1983) Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system J Neurosurg 59: 217–222PubMed Heilbrun MP, Roberts TS, Apuzzo ML, Wells THJ, Sabshin JK (1983) Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system J Neurosurg 59: 217–222PubMed
35.
go back to reference Henderson JM, Smith KR, Bucholz RD (1994) An accurate and ergonomic method of registration for image-guided neurosurgery Comput Med Imaging Graph 18: 273–277PubMedCrossRef Henderson JM, Smith KR, Bucholz RD (1994) An accurate and ergonomic method of registration for image-guided neurosurgery Comput Med Imaging Graph 18: 273–277PubMedCrossRef
36.
go back to reference Hill DL, Maurer CRJ, Maciunas RJ, Barwise JA, Fitzpatrick JM, Wang MY (1998) Measurement of intraoperative brain surface deformation under a craniotomy Neurosurgery 43: 514–526PubMedCrossRef Hill DL, Maurer CRJ, Maciunas RJ, Barwise JA, Fitzpatrick JM, Wang MY (1998) Measurement of intraoperative brain surface deformation under a craniotomy Neurosurgery 43: 514–526PubMedCrossRef
37.
go back to reference Hirschberg H, Unsgaard G (1997) Incorporation of ultrasonic imaging in an optically coupled frameless stereotactic system Acta Neurochir Suppl (Wien) 68: 75–80 Hirschberg H, Unsgaard G (1997) Incorporation of ultrasonic imaging in an optically coupled frameless stereotactic system Acta Neurochir Suppl (Wien) 68: 75–80
38.
go back to reference Horstmann GA, Reinhardt HF (1994) Ranging accuracy test of the sonic microstereometric system Neurosurgery 34: 754–755PubMed Horstmann GA, Reinhardt HF (1994) Ranging accuracy test of the sonic microstereometric system Neurosurgery 34: 754–755PubMed
39.
go back to reference Jodicke A, Deinsberger W, Erbe H, Kriete A, Boker DK (1998) Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing Minim Invasive Neurosurg 41: 13–19PubMed Jodicke A, Deinsberger W, Erbe H, Kriete A, Boker DK (1998) Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing Minim Invasive Neurosurg 41: 13–19PubMed
40.
go back to reference Kaminsky J, Brinker T, Samii A, Arango G, Vorkapic P, Samii M (1999) Technical considerations regarding accuracy of the MKM navigation system. An experimental study on impact factors Neurol Res 24: 420–424 Kaminsky J, Brinker T, Samii A, Arango G, Vorkapic P, Samii M (1999) Technical considerations regarding accuracy of the MKM navigation system. An experimental study on impact factors Neurol Res 24: 420–424
41.
go back to reference Kandel EI, Schavinsky YV (1972) Stereotaxic apparatus and operations in Russia in the 19th century J Neurosurg 37: 407–411PubMed Kandel EI, Schavinsky YV (1972) Stereotaxic apparatus and operations in Russia in the 19th century J Neurosurg 37: 407–411PubMed
42.
go back to reference Kato A, Yoshimine T, Hayakawa T, Tomita Y, Ikeda T, Mitomo M, Harada K, Mogami H (1991) A frameless, armless navigational system for computer-assisted neurosurgery Technical note J Neurosurg 74: 845–849PubMed Kato A, Yoshimine T, Hayakawa T, Tomita Y, Ikeda T, Mitomo M, Harada K, Mogami H (1991) A frameless, armless navigational system for computer-assisted neurosurgery Technical note J Neurosurg 74: 845–849PubMed
43.
go back to reference Kelly PJ (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration (comment) Neurosurgery 41: 613–614CrossRef Kelly PJ (1997) Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration (comment) Neurosurgery 41: 613–614CrossRef
44.
go back to reference Kelly PJ, Alker GJ Jr., Goerss S (1982) Computer-assisted stereotactic laser microsurgery for the treatment of intracranial neoplasms Neurosurgery 10: 324–331PubMed Kelly PJ, Alker GJ Jr., Goerss S (1982) Computer-assisted stereotactic laser microsurgery for the treatment of intracranial neoplasms Neurosurgery 10: 324–331PubMed
45.
go back to reference Kelly PJ, Goerss SJ, Kall BA (1988) Evolution of contemporary instrumentation for computer-assisted stereotactic surgery Surg Neurol 30: 204–215PubMedCrossRef Kelly PJ, Goerss SJ, Kall BA (1988) Evolution of contemporary instrumentation for computer-assisted stereotactic surgery Surg Neurol 30: 204–215PubMedCrossRef
46.
go back to reference Kelly PJ, Kall BA, Goerss S (1984) Transposition of volumetric information derived from computed tomography scanning into stereotactic space Surg Neurol 21: 465–471PubMedCrossRef Kelly PJ, Kall BA, Goerss S (1984) Transposition of volumetric information derived from computed tomography scanning into stereotactic space Surg Neurol 21: 465–471PubMedCrossRef
47.
go back to reference Kelly PJ, Olson MH, Wright AE (1978) Stereotactic implantation of iridium192 into CNS neoplasms Surg Neurol 10: 349–354PubMed Kelly PJ, Olson MH, Wright AE (1978) Stereotactic implantation of iridium192 into CNS neoplasms Surg Neurol 10: 349–354PubMed
48.
go back to reference King AP, Edwards PJ, Maurer CR Jr., de Cunha DA, Hawkes DJ, Hill DL, Gaston RP, Fenlon MR, Strong AJ, Chandler CL, Richards A, Gleeson MJ (1999) A system for microscope-assisted guided interventions Stereotact Funct Neurosurg 72: 107–111PubMedCrossRef King AP, Edwards PJ, Maurer CR Jr., de Cunha DA, Hawkes DJ, Hill DL, Gaston RP, Fenlon MR, Strong AJ, Chandler CL, Richards A, Gleeson MJ (1999) A system for microscope-assisted guided interventions Stereotact Funct Neurosurg 72: 107–111PubMedCrossRef
49.
go back to reference Knauth M, Wirtz CR, Tronnier VM, Aras N, Kunze S, Sartor K (1999) Intraoperative MR imaging increases the extent of tumor resection in patients with high-grade gliomas [see comments] AJNR Am J Neuroradiol 20: 1642–1646PubMed Knauth M, Wirtz CR, Tronnier VM, Aras N, Kunze S, Sartor K (1999) Intraoperative MR imaging increases the extent of tumor resection in patients with high-grade gliomas [see comments] AJNR Am J Neuroradiol 20: 1642–1646PubMed
50.
go back to reference Koivukangas J, Louhisalmi Y, Alakuijala J, Oikarinen J (1993) Ultrasound-controlled neuronavigator-guided brain surgery J Neurosurg 79: 36–42PubMed Koivukangas J, Louhisalmi Y, Alakuijala J, Oikarinen J (1993) Ultrasound-controlled neuronavigator-guided brain surgery J Neurosurg 79: 36–42PubMed
51.
go back to reference Kurimoto M, Hayashi N, Kamiyama H, Nagai S, Shibata T, Asahi T, Matsumura N, Hirashima Y, Endo S (2004) Impact of neuronavigation and image-guided extensive resection for adult patients with supratentorial malignant astrocytomas: a single-institution retrospective study Minim Invasive Neurosurg 47: 278–283PubMedCrossRef Kurimoto M, Hayashi N, Kamiyama H, Nagai S, Shibata T, Asahi T, Matsumura N, Hirashima Y, Endo S (2004) Impact of neuronavigation and image-guided extensive resection for adult patients with supratentorial malignant astrocytomas: a single-institution retrospective study Minim Invasive Neurosurg 47: 278–283PubMedCrossRef
52.
go back to reference Leksell L (1949) A stereotaxic apparatus for intracranial neurosurgery Acta Chir Scand 99: 229–253 Leksell L (1949) A stereotaxic apparatus for intracranial neurosurgery Acta Chir Scand 99: 229–253
53.
go back to reference Leksell L, Jernberg B (1980) Stereotaxis and tomography. A technical note Acta Neurochir (Wien) 52: 1–7CrossRef Leksell L, Jernberg B (1980) Stereotaxis and tomography. A technical note Acta Neurochir (Wien) 52: 1–7CrossRef
54.
go back to reference Leksell L, Leksell D, Schwebel J (1985) Stereotaxis and nuclear magnetic resonance J Neurol Neurosurg Psychiatry 48: 14–18PubMedCrossRef Leksell L, Leksell D, Schwebel J (1985) Stereotaxis and nuclear magnetic resonance J Neurol Neurosurg Psychiatry 48: 14–18PubMedCrossRef
55.
go back to reference Letteboer MMJ, Hellier P, Rueckert D, Willems PW, Niessen WJ (2004) Non-rigid registration of intraoperatively acquired 3D ultrasound data of brain tumours. IEEE-TMI Letteboer MMJ, Hellier P, Rueckert D, Willems PW, Niessen WJ (2004) Non-rigid registration of intraoperatively acquired 3D ultrasound data of brain tumours. IEEE-TMI
56.
go back to reference Letteboer MMJ, Willems PW, Viergever MA, Niessen WJ (2003) Non-rigid registration of 3D ultrasound images of brain tumours acquired during neurosurgery Letteboer MMJ, Willems PW, Viergever MA, Niessen WJ (2003) Non-rigid registration of 3D ultrasound images of brain tumours acquired during neurosurgery
57.
go back to reference Lewin JS (1999) Interventional MR imaging: concepts, systems, and applications in neuroradiology AJNR Am J Neuroradiol 20: 735–748PubMed Lewin JS (1999) Interventional MR imaging: concepts, systems, and applications in neuroradiology AJNR Am J Neuroradiol 20: 735–748PubMed
58.
go back to reference Lindseth F, Kaspersen JH, Ommedal S, Lango T, Bang J, Hokland J, Unsgaard G, Hernes TA (2003) Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound Comput Aided Surg 8: 49–69PubMed Lindseth F, Kaspersen JH, Ommedal S, Lango T, Bang J, Hokland J, Unsgaard G, Hernes TA (2003) Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound Comput Aided Surg 8: 49–69PubMed
59.
go back to reference Lunsford LD, Deutsch M, Yoder V (1985) Stereotactic interstitial brachytherapy: Current concepts and concerns in 20 patients Appl Neurophysiol 48: 117–120PubMed Lunsford LD, Deutsch M, Yoder V (1985) Stereotactic interstitial brachytherapy: Current concepts and concerns in 20 patients Appl Neurophysiol 48: 117–120PubMed
60.
go back to reference Manwaring KH (93) Intraoperative microendoscopy. In: Maciunas RJ (ed) Interactive Image-Guided Surgery. American Association of Neurological Surgeons, pp 217–232 Manwaring KH (93) Intraoperative microendoscopy. In: Maciunas RJ (ed) Interactive Image-Guided Surgery. American Association of Neurological Surgeons, pp 217–232
61.
go back to reference Marmulla R, Hilbert M, Niederdellmann H (1997) Inherent precision of mechanical, infrared and laser-guided navigation systems for computer-assisted surgery J Craniomaxillofac Surg 25: 192–197PubMed Marmulla R, Hilbert M, Niederdellmann H (1997) Inherent precision of mechanical, infrared and laser-guided navigation systems for computer-assisted surgery J Craniomaxillofac Surg 25: 192–197PubMed
62.
go back to reference Matula C, Rossler K, Reddy M, Schindler E, Koos WT (1998) Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow Comput Aided Surg 3: 174–182PubMedCrossRef Matula C, Rossler K, Reddy M, Schindler E, Koos WT (1998) Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow Comput Aided Surg 3: 174–182PubMedCrossRef
63.
go back to reference Maurer CR, Jr., Fitzpatrick JM, Wang MY, Galloway RL, Jr., Maciunas RJ, Allen GS (1997) Registration of head volume images using implantable fiducial markers IEEE Trans Med Imaging 16: 447–462PubMedCrossRef Maurer CR, Jr., Fitzpatrick JM, Wang MY, Galloway RL, Jr., Maciunas RJ, Allen GS (1997) Registration of head volume images using implantable fiducial markers IEEE Trans Med Imaging 16: 447–462PubMedCrossRef
64.
go back to reference Maurer CRJ, Hill DL, Martin AJ, Liu H, McCue M, Rueckert D, Lloret D, Hall WA, Maxwell RE, Hawkes DJ, Truwit CL (1998) Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results IEEE Trans Med Imaging 17: 817–825PubMedCrossRef Maurer CRJ, Hill DL, Martin AJ, Liu H, McCue M, Rueckert D, Lloret D, Hall WA, Maxwell RE, Hawkes DJ, Truwit CL (1998) Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results IEEE Trans Med Imaging 17: 817–825PubMedCrossRef
65.
go back to reference McDermott MW, Gutin PH (1996) Image-guided surgery for skull base neoplasms using the ISG viewing wand. Anatomic and technical considerations. Neurosurg Clin N Am 7: 285–295 McDermott MW, Gutin PH (1996) Image-guided surgery for skull base neoplasms using the ISG viewing wand. Anatomic and technical considerations. Neurosurg Clin N Am 7: 285–295
66.
go back to reference McPherson CM, Bohinski RJ, Dagnew E, Warnick RE, Tew JM (2003) Tumor resection in a shared-resource magnetic resonance operating room: experience at the University of Cincinnati Acta Neurochir Suppl (Wien) 85: 39–44 McPherson CM, Bohinski RJ, Dagnew E, Warnick RE, Tew JM (2003) Tumor resection in a shared-resource magnetic resonance operating room: experience at the University of Cincinnati Acta Neurochir Suppl (Wien) 85: 39–44
67.
go back to reference Mundinger F, Birg W, Klar M (1978) Computer-assisted stereotactic brain operations by means including computerized axial tomography Appl Neurophysiol 41: 169–182PubMed Mundinger F, Birg W, Klar M (1978) Computer-assisted stereotactic brain operations by means including computerized axial tomography Appl Neurophysiol 41: 169–182PubMed
68.
go back to reference Narabayashi H (1952) Stereotaxic instrument for operation on the human basal ganglia Psychiat Neurol Japan 54: 669–671 Narabayashi H (1952) Stereotaxic instrument for operation on the human basal ganglia Psychiat Neurol Japan 54: 669–671
69.
go back to reference Nimsky C, Fujita A, Ganslandt O, Von Keller B, Fahlbusch R (2004) Volumetric assessment of glioma removal by intraoperative high-field magnetic resonance imaging Neurosurgery 55: 358–370PubMedCrossRef Nimsky C, Fujita A, Ganslandt O, Von Keller B, Fahlbusch R (2004) Volumetric assessment of glioma removal by intraoperative high-field magnetic resonance imaging Neurosurgery 55: 358–370PubMedCrossRef
70.
go back to reference Nimsky C, Ganslandt O, Cerny S, Hastreiter P, Greiner G, Fahlbusch R (2000) Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging Neurosurgery 47: 1070–1079PubMedCrossRef Nimsky C, Ganslandt O, Cerny S, Hastreiter P, Greiner G, Fahlbusch R (2000) Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging Neurosurgery 47: 1070–1079PubMedCrossRef
71.
go back to reference Nimsky C, Ganslandt O, Von Keller B, Fahlbusch R (2003) Preliminary experience in glioma surgery with intraoperative high-field MRI Acta Neurochir(Wien)Suppl 88: 21–29 Nimsky C, Ganslandt O, Von Keller B, Fahlbusch R (2003) Preliminary experience in glioma surgery with intraoperative high-field MRI Acta Neurochir(Wien)Suppl 88: 21–29
72.
go back to reference Orth RC, Sinha P, Madsen EL, Frank G, Korosec FR, Mackie TR, Mehta MP (1999) Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization Neurosurgery 45: 1423–1429PubMedCrossRef Orth RC, Sinha P, Madsen EL, Frank G, Korosec FR, Mackie TR, Mehta MP (1999) Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization Neurosurgery 45: 1423–1429PubMedCrossRef
73.
go back to reference Ostertag CB, Mennel HD, Kiessling M (1980) Stereotactic biopsy of brain tumors Surg Neurol 14: 275–283PubMed Ostertag CB, Mennel HD, Kiessling M (1980) Stereotactic biopsy of brain tumors Surg Neurol 14: 275–283PubMed
74.
go back to reference Paleologos TS, Wadley JP, Kitchen ND, Thomas DG (2000) Clinical utility and cost-effectiveness of interactive image-guided craniotomy: clinical comparison between conventional and image-guided meningioma surgery [In Process Citation] Neurosurgery 47: 40–47PubMedCrossRef Paleologos TS, Wadley JP, Kitchen ND, Thomas DG (2000) Clinical utility and cost-effectiveness of interactive image-guided craniotomy: clinical comparison between conventional and image-guided meningioma surgery [In Process Citation] Neurosurgery 47: 40–47PubMedCrossRef
75.
go back to reference Perry JH, Rosenbaum AE, Lunsford LD, Swink CA, Zorub DS (1980) Computed tomography/guided stereotactic surgery: conception and development of a new stereotactic methodology Neurosurgery 7: 376–381PubMed Perry JH, Rosenbaum AE, Lunsford LD, Swink CA, Zorub DS (1980) Computed tomography/guided stereotactic surgery: conception and development of a new stereotactic methodology Neurosurgery 7: 376–381PubMed
76.
go back to reference Poggi S, Pallotta S, Russo S, Gallina P, Torresin A, Bucciolini M (2003) Neuronavigation accuracy dependence on CT and MR imaging parameters: a phantom-based study Phys Med Biol 48: 2199–2216PubMedCrossRef Poggi S, Pallotta S, Russo S, Gallina P, Torresin A, Bucciolini M (2003) Neuronavigation accuracy dependence on CT and MR imaging parameters: a phantom-based study Phys Med Biol 48: 2199–2216PubMedCrossRef
77.
go back to reference Reinhardt HF, Zweifel HJ (1990) Interactive sonar-operated device for stereotactic and open surgery Stereotact Funct Neurosurg 54–55: 393–397PubMed Reinhardt HF, Zweifel HJ (1990) Interactive sonar-operated device for stereotactic and open surgery Stereotact Funct Neurosurg 54–55: 393–397PubMed
78.
go back to reference Riechert T, Wolff M (1951) Uber eine neues Zielgerat zur intracraniellen electriche Ableitung und Ausschaltung Arch Psych Z Neurol 186: 225–230CrossRef Riechert T, Wolff M (1951) Uber eine neues Zielgerat zur intracraniellen electriche Ableitung und Ausschaltung Arch Psych Z Neurol 186: 225–230CrossRef
79.
go back to reference Roberts DW (95) Frameless stereotaxy. In: Cohen AR, Haines SJ (eds) Minimally invasive techniques in neurosurgery. pp 78–84 Roberts DW (95) Frameless stereotaxy. In: Cohen AR, Haines SJ (eds) Minimally invasive techniques in neurosurgery. pp 78–84
80.
go back to reference Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases Neurosurgery 43(4): 749–758PubMedCrossRef Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases Neurosurgery 43(4): 749–758PubMedCrossRef
81.
go back to reference Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD (1999) Intraoperatively updated neuroimaging using brain modeling and sparse data Neurosurgery 45(5): 1199–1206PubMedCrossRef Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD (1999) Intraoperatively updated neuroimaging using brain modeling and sparse data Neurosurgery 45(5): 1199–1206PubMedCrossRef
82.
go back to reference Roberts DW, Strohbehn JW, Hatch JF, Murray W, Kettenberger H (1986) A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope J Neurosurg 65: 545–549PubMedCrossRef Roberts DW, Strohbehn JW, Hatch JF, Murray W, Kettenberger H (1986) A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope J Neurosurg 65: 545–549PubMedCrossRef
83.
go back to reference Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C, Czech T, Koos WT (1998) Frameless stereotactic lesion contour-guided surgery using a computer- navigated microscope Surg Neurol 49: 282–288PubMedCrossRef Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C, Czech T, Koos WT (1998) Frameless stereotactic lesion contour-guided surgery using a computer- navigated microscope Surg Neurol 49: 282–288PubMedCrossRef
84.
go back to reference Rossolimo GI (1907) The brain topograph (device for projection of brain parts on the skull surface) Ezheg Ekaterin Bolnizi 1: 63–65 Rossolimo GI (1907) The brain topograph (device for projection of brain parts on the skull surface) Ezheg Ekaterin Bolnizi 1: 63–65
85.
go back to reference Ryan MJ, Erickson RK, Levin DN, Pelizzari CA, Macdonald RL, Dohrmann GJ (1996) Frameless stereotaxy with real-time tracking of patient head movement and retrospective patient-image registration J Neurosurg 85: 287–292PubMed Ryan MJ, Erickson RK, Levin DN, Pelizzari CA, Macdonald RL, Dohrmann GJ (1996) Frameless stereotaxy with real-time tracking of patient head movement and retrospective patient-image registration J Neurosurg 85: 287–292PubMed
86.
go back to reference Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/Elekta viewing Wand Acta Neurochir Suppl (Wien) 64: 54–58 Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/Elekta viewing Wand Acta Neurochir Suppl (Wien) 64: 54–58
87.
go back to reference Sandeman DR, Patel N, Chandler C, Nelson RJ, Coakham HB, Griffith HB (1994) Advances in image-directed neurosurgery: preliminary experience with the ISG Viewing Wand compared with the Leksell G frame Br J Neurosurg 8: 529–544PubMed Sandeman DR, Patel N, Chandler C, Nelson RJ, Coakham HB, Griffith HB (1994) Advances in image-directed neurosurgery: preliminary experience with the ISG Viewing Wand compared with the Leksell G frame Br J Neurosurg 8: 529–544PubMed
88.
go back to reference Schad L, Lott S, Schmitt F, Sturm V, Lorenz WJ (1987) Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy J Comput Assist Tomogr 11: 499–505PubMed Schad L, Lott S, Schmitt F, Sturm V, Lorenz WJ (1987) Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy J Comput Assist Tomogr 11: 499–505PubMed
89.
go back to reference Schlaier J, Warnat J, Brawanski A (2002) Registration accuracy and practicability of laser-directed surface matching Comput Aided Surg 7: 284–290PubMedCrossRef Schlaier J, Warnat J, Brawanski A (2002) Registration accuracy and practicability of laser-directed surface matching Comput Aided Surg 7: 284–290PubMedCrossRef
90.
go back to reference Shelden CH, McCann G, Jacques S, Lutes HR, Frazier RE, Katz R, Kuki R (1980) Development of a computerized microstereotaxic method for localization and removal of minute CNS lesions under direct 3-D vision Technical report. J Neurosurg 52: 21–27 Shelden CH, McCann G, Jacques S, Lutes HR, Frazier RE, Katz R, Kuki R (1980) Development of a computerized microstereotaxic method for localization and removal of minute CNS lesions under direct 3-D vision Technical report. J Neurosurg 52: 21–27
91.
go back to reference Sipos EP, Tebo SA, Zinreich SJ, Long DM, Brem H (1996) In vivo accuracy testing and clinical experience with the ISG Viewing Wand Neurosurgery 39: 194–202PubMedCrossRef Sipos EP, Tebo SA, Zinreich SJ, Long DM, Brem H (1996) In vivo accuracy testing and clinical experience with the ISG Viewing Wand Neurosurgery 39: 194–202PubMedCrossRef
92.
go back to reference Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation–a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery Comput Med Imaging Graph 18: 247–256PubMedCrossRef Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation–a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery Comput Med Imaging Graph 18: 247–256PubMedCrossRef
93.
go back to reference Spiegel EA, Wycis HT, Marks M, Lee ASJ (1947) Stereotaxic apparatus for operations on the human brain Science 106: 349–350PubMed Spiegel EA, Wycis HT, Marks M, Lee ASJ (1947) Stereotaxic apparatus for operations on the human brain Science 106: 349–350PubMed
94.
go back to reference Sumanaweera TS, Adler JR Jr., Napel S, Glover GH (1994) Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery Neurosurgery 35: 696–703PubMed Sumanaweera TS, Adler JR Jr., Napel S, Glover GH (1994) Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery Neurosurgery 35: 696–703PubMed
95.
go back to reference Tan KK, Grzeszczuk R, Levin DN, Pelizzari CA, Chen GT, Erickson RK, Johnson D, Dohrmann GJ (1993) A frameless stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note J Neurosurg 79: 296–303PubMed Tan KK, Grzeszczuk R, Levin DN, Pelizzari CA, Chen GT, Erickson RK, Johnson D, Dohrmann GJ (1993) A frameless stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note J Neurosurg 79: 296–303PubMed
96.
go back to reference Villalobos H, Germano IM (1999) Clinical evaluation of multimodality registration in frameless stereotaxy Comput Aided Surg 4: 45–49PubMedCrossRef Villalobos H, Germano IM (1999) Clinical evaluation of multimodality registration in frameless stereotaxy Comput Aided Surg 4: 45–49PubMedCrossRef
97.
go back to reference Walton L, Hampshire A, Forster DM, Kemeny AA (1996) A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system Neurosurgery 38: 170–176PubMedCrossRef Walton L, Hampshire A, Forster DM, Kemeny AA (1996) A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system Neurosurgery 38: 170–176PubMedCrossRef
98.
go back to reference Watanabe E, Mayanagi Y, Kosugi Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm Neurosurgery 28(6): 792–799PubMedCrossRef Watanabe E, Mayanagi Y, Kosugi Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm Neurosurgery 28(6): 792–799PubMedCrossRef
99.
go back to reference Watanabe E, Watanabe T, Manaka S, Mayanagi Y, Takakura K (1987) Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery Surg Neurol 27: 543–547PubMedCrossRef Watanabe E, Watanabe T, Manaka S, Mayanagi Y, Takakura K (1987) Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery Surg Neurol 27: 543–547PubMedCrossRef
100.
go back to reference Willems PW, Berkelbach van der Sprenkel JW, Tulleken CAF (2001) Comparison of adhesive markers, anatomical landmarks and surface matching in patient-to-image registration for frameless stereotaxy. Gannot I, Gulyaev YV, Papazoglou TG, van Swol CFP (eds), Proceedings of SPIE: 156–163 Willems PW, Berkelbach van der Sprenkel JW, Tulleken CAF (2001) Comparison of adhesive markers, anatomical landmarks and surface matching in patient-to-image registration for frameless stereotaxy. Gannot I, Gulyaev YV, Papazoglou TG, van Swol CFP (eds), Proceedings of SPIE: 156–163
101.
go back to reference Willems PW, Noordmans HJ, Berkelbach van der Sprenkel JW, Viergever MA, Tulleken CA (2001) An MKM-mounted instrument holder for frameless point-stereotactic procedures: a phantom-based accuracy evaluation J Neurosurg 95: 1067–1074PubMedCrossRef Willems PW, Noordmans HJ, Berkelbach van der Sprenkel JW, Viergever MA, Tulleken CA (2001) An MKM-mounted instrument holder for frameless point-stereotactic procedures: a phantom-based accuracy evaluation J Neurosurg 95: 1067–1074PubMedCrossRef
102.
go back to reference Willems PW, Noordmans HJ, Ramos LM, Taphoorn MJ, Berkelbach van der Sprenkel JW, Viergever MA, Tulleken CA (2003) Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holder Acta Neurochir (Wien) 145: 889–897CrossRef Willems PW, Noordmans HJ, Ramos LM, Taphoorn MJ, Berkelbach van der Sprenkel JW, Viergever MA, Tulleken CA (2003) Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holder Acta Neurochir (Wien) 145: 889–897CrossRef
103.
go back to reference Willems PW, Noordmans HJ, van Overbeeke JJ, Viergever MA, Tulleken CA, van der Sprenkel JW (2005) The impact of auditory feedback on neuronavigation Acta Neurochir (Wien) 147: 167–173CrossRef Willems PW, Noordmans HJ, van Overbeeke JJ, Viergever MA, Tulleken CA, van der Sprenkel JW (2005) The impact of auditory feedback on neuronavigation Acta Neurochir (Wien) 147: 167–173CrossRef
104.
go back to reference Wirtz CR, Albert FK, Schwaderer M, Heuer C, Staubert A, Tronnier VM, Knauth M, Kunze S (2000) The benefit of neuronavigation for neurosurgery analyzed by its impact on glioblastoma surgery Neurol Res 22: 354–360PubMed Wirtz CR, Albert FK, Schwaderer M, Heuer C, Staubert A, Tronnier VM, Knauth M, Kunze S (2000) The benefit of neuronavigation for neurosurgery analyzed by its impact on glioblastoma surgery Neurol Res 22: 354–360PubMed
105.
go back to reference Wirtz CR, Knauth M, Staubert A, Bonsanto MM, Sartor K, Kunze S, Tronnier VM (2000) Clinical evaluation and follow-up results for intraoperative magnetic resonance imaging in neurosurgery Neurosurgery 46: 1112–1120PubMedCrossRef Wirtz CR, Knauth M, Staubert A, Bonsanto MM, Sartor K, Kunze S, Tronnier VM (2000) Clinical evaluation and follow-up results for intraoperative magnetic resonance imaging in neurosurgery Neurosurgery 46: 1112–1120PubMedCrossRef
106.
go back to reference Zamorano LJ, Nolte L, Kadi AM, Jiang Z (1993) Interactive intraoperative localization using an infrared-based system Neurol Res 15: 290–298PubMed Zamorano LJ, Nolte L, Kadi AM, Jiang Z (1993) Interactive intraoperative localization using an infrared-based system Neurol Res 15: 290–298PubMed
107.
go back to reference Zernov DN (1889) Encephalometer. Device for estimation of parts of brain in human. 70–8 Zernov DN (1889) Encephalometer. Device for estimation of parts of brain in human. 70–8
Metadata
Title
Neuronavigation and surgery of intracerebral tumours
Authors
P.W.A. Willems
J.W. Berkelbach van der Sprenkel
C.A.F. Tulleken
M.A. Viergever
M.J.B. Taphoorn
Publication date
01-09-2006
Publisher
Steinkopff-Verlag
Published in
Journal of Neurology / Issue 9/2006
Print ISSN: 0340-5354
Electronic ISSN: 1432-1459
DOI
https://doi.org/10.1007/s00415-006-0158-3

Other articles of this Issue 9/2006

Journal of Neurology 9/2006 Go to the issue

OriginalPaper

ENS COMMUNICATIONS