Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 11/2007

01-11-2007 | Rhinology

Effects of an external nasal dilator strip (ENDS) compared to xylometazolin nasal spray

Authors: L. R. Høyvoll, K. Lunde, Henrik S. Li, S. Dahle, T. Wentzel-Larsen, S. K. Steinsvåg

Published in: European Archives of Oto-Rhino-Laryngology | Issue 11/2007

Login to get access

Abstract

Nasal blockage is a common complaint in Family Practice. Decongestive nosedrops are frequently employed therapeutic measures. Due to a considerable risk of abuse and side effects, alternatives are wanted. The purpose of this study was to elucidate to what extent ENDS might represent an alternative to decongestive nose sprays (DNS). The effects of DNS (xylometazolin) and ENDS (BreatheRight®) on subjective and objective nasal blockage were compared in 89 patients. Main outcome measures were recordings of nasal symptom scores on visual analogue scales (VAS), minimal cross-sectional areas (MCA) and nasal cavity volumes (NCV) as measured by acoustic rhinometry (AR), and peak nasal inspiratory flow (PNIF). ENDS significantly increased the MCA and the NCV in the anterior 0.0–3.0 cm of the nose compared to DNS, but had no effect on MCA from 3.0 to 5.4 cm behind the nostrils. In contrast to DNS, ENDS had no effect on the posterior NCV. ENDS and DNS gave comparable increase in nasal inspiratory flow as measured by PNIF, and in the subject’s own experience of nasal obstruction. ENDS may represent an alternative to DNS as a measure against nasal blockage.
Literature
1.
go back to reference Dahl R (1993) Rhinitis and asthma. In: Mygind N, Naclerio R (eds) Allergic and nonallergic rhinitis. Munksgaard, Copenhagen, pp 184–188 Dahl R (1993) Rhinitis and asthma. In: Mygind N, Naclerio R (eds) Allergic and nonallergic rhinitis. Munksgaard, Copenhagen, pp 184–188
2.
go back to reference Lofaso F, Coste A, d’Ortho M, Zerah-Lancner F, Delclaux C, Goldenberg F (2000) Nasal obstruction as a risk factor for sleep apnoea syndrome. Eur Respir J 16:639–643PubMedCrossRef Lofaso F, Coste A, d’Ortho M, Zerah-Lancner F, Delclaux C, Goldenberg F (2000) Nasal obstruction as a risk factor for sleep apnoea syndrome. Eur Respir J 16:639–643PubMedCrossRef
3.
go back to reference Craig T, Teets S, Lehman E, Chinchilli V, Zwillich C (1998) Nasal congestion secondary to allergic rhinitis as a cause of sleep disturbance and daytime fatigue and the response to topical nasal corticosteroids. J Allergy Clin Immunol 101:633–637PubMedCrossRef Craig T, Teets S, Lehman E, Chinchilli V, Zwillich C (1998) Nasal congestion secondary to allergic rhinitis as a cause of sleep disturbance and daytime fatigue and the response to topical nasal corticosteroids. J Allergy Clin Immunol 101:633–637PubMedCrossRef
4.
go back to reference Lucente F (1989) Rhinitis and nasal obstruction. Otolaryngol Clin North Am 2:307–318 Lucente F (1989) Rhinitis and nasal obstruction. Otolaryngol Clin North Am 2:307–318
6.
go back to reference Fadal R (1987) The medical management of rhinitis. In: English G (ed) Otolaryngology. Lippincott, Philadelphia, pp 1–25 Fadal R (1987) The medical management of rhinitis. In: English G (ed) Otolaryngology. Lippincott, Philadelphia, pp 1–25
7.
go back to reference Corey J, Houser S, Bernard A (2000) Nasal congestion: a rewiev of its etiology, evaluation, and treatment. Ear Nose Throat J 79:690–703PubMed Corey J, Houser S, Bernard A (2000) Nasal congestion: a rewiev of its etiology, evaluation, and treatment. Ear Nose Throat J 79:690–703PubMed
8.
go back to reference Griffin J, Hunter G, Ferguson D, Sillers M (1997) Physiologic effects of an external nasal dilator. Laryngoscope 107:1235–1238PubMedCrossRef Griffin J, Hunter G, Ferguson D, Sillers M (1997) Physiologic effects of an external nasal dilator. Laryngoscope 107:1235–1238PubMedCrossRef
9.
go back to reference Shaida A, Kenyon G (2000) The nasal valves: changes in anatimy and physiology in normal subjects. Rhinology 38:7–12PubMed Shaida A, Kenyon G (2000) The nasal valves: changes in anatimy and physiology in normal subjects. Rhinology 38:7–12PubMed
10.
go back to reference Graf P (1999) Adverse effects of benzalkonium chloride on the nasal mucosa: allergic rhinitis and rhinitis medicamentosa. Clin Ther 21:1749–1755PubMedCrossRef Graf P (1999) Adverse effects of benzalkonium chloride on the nasal mucosa: allergic rhinitis and rhinitis medicamentosa. Clin Ther 21:1749–1755PubMedCrossRef
11.
go back to reference Hilberg O (2002) Objective measurement of nasal airway dimensions using acoustic rhinometry: methodological and clinical aspects. Allergy 57:5–39PubMedCrossRef Hilberg O (2002) Objective measurement of nasal airway dimensions using acoustic rhinometry: methodological and clinical aspects. Allergy 57:5–39PubMedCrossRef
12.
go back to reference O’Kroy J, James T, Miller J, Torok D, Campbell K (2001) Effects of an external nasal dilator on the work of breathing during exercise. Med Sci Sports Exerc 33:454–458PubMedCrossRef O’Kroy J, James T, Miller J, Torok D, Campbell K (2001) Effects of an external nasal dilator on the work of breathing during exercise. Med Sci Sports Exerc 33:454–458PubMedCrossRef
13.
go back to reference Kirkness J, Wheatley J, Amis T (2000) Nasal airflow dynamics: mechanisms and responses associated with an external nasal dilator strip. Eur Respir J 15:929–936PubMedCrossRef Kirkness J, Wheatley J, Amis T (2000) Nasal airflow dynamics: mechanisms and responses associated with an external nasal dilator strip. Eur Respir J 15:929–936PubMedCrossRef
14.
go back to reference Wihl J-A, Malm L 1988 Rhinomanometry and nasal peak expiratory and inspiratory flow rate. Ann Allergy 6:50–55 Wihl J-A, Malm L 1988 Rhinomanometry and nasal peak expiratory and inspiratory flow rate. Ann Allergy 6:50–55
15.
go back to reference Taverner D, Bickford L, Latte J (2002) Validation by fluid volume of acoustic rhinometry before and after decongestant in normal subjects. Rhinology 40:135–140PubMed Taverner D, Bickford L, Latte J (2002) Validation by fluid volume of acoustic rhinometry before and after decongestant in normal subjects. Rhinology 40:135–140PubMed
16.
go back to reference Lorino A, Lofaso F, Drogou I, Abi-Nader F, Dahan E, Coste A 1998 Effects of different mechanical treatments on nasal resistance assessed by rhinometry. Chest 114:166–167PubMed Lorino A, Lofaso F, Drogou I, Abi-Nader F, Dahan E, Coste A 1998 Effects of different mechanical treatments on nasal resistance assessed by rhinometry. Chest 114:166–167PubMed
17.
go back to reference Clark R, Jones A, Richardson H (1995) Peak nasal inspiratory flow-the plateau effect. J Laryngol Otol 109:399–402 Clark R, Jones A, Richardson H (1995) Peak nasal inspiratory flow-the plateau effect. J Laryngol Otol 109:399–402
18.
go back to reference Pevernaige D, Hamans E, Van Cauvenberge P, Pauwels R (2000) External nasal dilatation reduces snoring in chronic rhinitis patients: a randomized controlled trial. Eur Respir J 15:996–1000CrossRef Pevernaige D, Hamans E, Van Cauvenberge P, Pauwels R (2000) External nasal dilatation reduces snoring in chronic rhinitis patients: a randomized controlled trial. Eur Respir J 15:996–1000CrossRef
21.
go back to reference Vermoen C, Verbraak A, Bogaard J (1998) Effect of a nasal dilator on nasal patency during normal and forced nasal breathing. Int J Sports Med 19:109–913PubMedCrossRef Vermoen C, Verbraak A, Bogaard J (1998) Effect of a nasal dilator on nasal patency during normal and forced nasal breathing. Int J Sports Med 19:109–913PubMedCrossRef
Metadata
Title
Effects of an external nasal dilator strip (ENDS) compared to xylometazolin nasal spray
Authors
L. R. Høyvoll
K. Lunde
Henrik S. Li
S. Dahle
T. Wentzel-Larsen
S. K. Steinsvåg
Publication date
01-11-2007
Publisher
Springer-Verlag
Published in
European Archives of Oto-Rhino-Laryngology / Issue 11/2007
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-007-0345-6

Other articles of this Issue 11/2007

European Archives of Oto-Rhino-Laryngology 11/2007 Go to the issue