Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 2/2023

03-08-2021 | Orthopaedic Surgery

Osseoperception in transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation: a prospective study

Authors: Marcus Örgel, Mohamed Elareibi, Tilman Graulich, Christian Krettek, Claudia Neunaber, Horst-Heinrich Aschoff, Alexander Ranker, Marcel Winkelmann

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2023

Login to get access

Abstract

Background

Endo-exo prosthetics (EEP), which belongs to the transcutaneous osseointegrated prosthetic systems (TOPS), provides an alternative bone-anchored rehabilitation method for transfemoral amputees. It led to the question of whether transmitted forces from prosthetic feet are perceptible by osseoperception resulting in proprioceptive feedback of ground conditions.

Objectives

The following hypotheses emerged for our trial with the null hypothesis: EEP fitting after transfemoral amputation does not influence osseoperception. Alternative hypothesis 1: EEP patients achieve better osseoperception results than transfemoral amputees fitted with socket prosthesis. Alternative hypothesis 2: EEP carriers achieve comparable results with regards to their osseoperception as non-amputees.

Methods

N = 25 patients with EEP (mean age = 50,6 ± 9,4, male/female = 15/10) N = 25 patients with socket prostheses (mean age = 52,6 ± 13,1, male/female = 19/6) and N = 25 healthy volunteers were included in the experimental case–control study. In three blinded test modules (V1, V2, V3), the participants had to identify different degrees of shore hardness (c) of different materials (rubber balls (shore = 5–25c), foam cushions (shore = 5–30c), foam mats (shore = 5–30c) with their prosthetic foot (or a personally defined foot in healthy volunteers) without footwear and had to rank them into the correct order according to their tactile sensation and the degree of hardness. A maximum of 10 points could be scored per run.

Results

This experimental observational study included N = 75 participants. The mean age for the entire cohort was 42.8 ± 16.6 years and the BMI was 26.0 ± 4.8. Our results show a significant level of differences in tactile osseoperception between all groups (p < 0.001). A correlation between the mean values of V1-3 and the PMQ2.0 as well as the mean values of K-Level and the prosthesis wearing time per day showed for PMQ (r = 0.387, p = 0.006) and K-level (r = 0.448, p = 0.001) which is a moderate effect according to Cohen.

Conclusion

Our study results suggest that the EEP treatment can lead to an improvement in tactile sensory perception via the bone-anchored implant, which can lead to an increase in quality of life and improved gait safety.
Literature
3.
go back to reference Ranker Alexander ÖM, Peter BJ, Christian K, Heinrich AH (2020) Transcutaneous osseointegrated prosthetic systems (TOPS) for transfemoral amputees a six-year retrospective analysis of the latest prosthetic design in Germany. Rehabilitation 59:51–59. https://doi.org/10.1055/a-1223-3205CrossRef Ranker Alexander ÖM, Peter BJ, Christian K, Heinrich AH (2020) Transcutaneous osseointegrated prosthetic systems (TOPS) for transfemoral amputees a six-year retrospective analysis of the latest prosthetic design in Germany. Rehabilitation 59:51–59. https://​doi.​org/​10.​1055/​a-1223-3205CrossRef
18.
go back to reference Leijendekkers RA, van Hinte G, Frolke JP, van de Meent H, Atsma F, Nijhuis-van der Sanden MW, Hoogeboom TJ (2019) Functional performance and safety of bone-anchored prostheses in persons with a transfemoral or transtibial amputation: a prospective one-year follow-up cohort study. Clin Rehabil 33(3):450–464. https://doi.org/10.1177/0269215518815215CrossRefPubMed Leijendekkers RA, van Hinte G, Frolke JP, van de Meent H, Atsma F, Nijhuis-van der Sanden MW, Hoogeboom TJ (2019) Functional performance and safety of bone-anchored prostheses in persons with a transfemoral or transtibial amputation: a prospective one-year follow-up cohort study. Clin Rehabil 33(3):450–464. https://​doi.​org/​10.​1177/​0269215518815215​CrossRefPubMed
21.
go back to reference 2 ITS (2010) Rubber, vulcanized or thermoplastic—determination of indentation hardness —part 4: durometer method (Shore hardness) (ISO 7619-1:2010) 2 ITS (2010) Rubber, vulcanized or thermoplastic—determination of indentation hardness —part 4: durometer method (Shore hardness) (ISO 7619-1:2010)
22.
go back to reference Wolfgang Grellmann SS (2015) Kunststoffprüfung. Carl Hanser Verlag Wolfgang Grellmann SS (2015) Kunststoffprüfung. Carl Hanser Verlag
23.
go back to reference Herrmann K (2007) Härteprüfung an Metallen und Kunststoffen : Grundlagen und Überblick zu modernen Verfahren; mit 66 Tabellen. Expert Verlag Herrmann K (2007) Härteprüfung an Metallen und Kunststoffen : Grundlagen und Überblick zu modernen Verfahren; mit 66 Tabellen. Expert Verlag
26.
go back to reference US Health Care Financing Administration (2001) Health and human services (ed) healthcare common procedure cod-ing system. US Health Care Financing Administration US Health Care Financing Administration (2001) Health and human services (ed) healthcare common procedure cod-ing system. US Health Care Financing Administration
27.
go back to reference Cohen J (1988) Statistical power analysis for the behavioral sciences, vol 2. Lawrence Erlbaum Associates Cohen J (1988) Statistical power analysis for the behavioral sciences, vol 2. Lawrence Erlbaum Associates
29.
go back to reference Engstrom B, Van de Ven C (1999) Therapy for Amputees 3rd Edition. Churchill Livingstone Engstrom B, Van de Ven C (1999) Therapy for Amputees 3rd Edition. Churchill Livingstone
30.
go back to reference Cohen J (1992) Statistical power analysis. Curr Dir Psychol Sci 1(3):98–101CrossRef Cohen J (1992) Statistical power analysis. Curr Dir Psychol Sci 1(3):98–101CrossRef
32.
33.
go back to reference Verrillo RT (1966) Vibrotactile sensitivity and the frequency response of the Pacinian corpuscle. Psyc Sci 4(1):135–136CrossRef Verrillo RT (1966) Vibrotactile sensitivity and the frequency response of the Pacinian corpuscle. Psyc Sci 4(1):135–136CrossRef
48.
go back to reference Enkling N, Utz KH, Bayer S, Stern RM (2010) Osseoperception: active tactile sensibility of osseointegrated dental implants. Int J Oral Maxillofac Implants 25(6):1159–1167PubMed Enkling N, Utz KH, Bayer S, Stern RM (2010) Osseoperception: active tactile sensibility of osseointegrated dental implants. Int J Oral Maxillofac Implants 25(6):1159–1167PubMed
Metadata
Title
Osseoperception in transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation: a prospective study
Authors
Marcus Örgel
Mohamed Elareibi
Tilman Graulich
Christian Krettek
Claudia Neunaber
Horst-Heinrich Aschoff
Alexander Ranker
Marcel Winkelmann
Publication date
03-08-2021
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2023
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-021-04099-1

Other articles of this Issue 2/2023

Archives of Orthopaedic and Trauma Surgery 2/2023 Go to the issue