Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible

Authors: Keizo Wada, Hiroshi Mikami, Daisuke Hamada, Hiroshi Yonezu, Koichi Oba, Koichi Sairyo

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2016

Login to get access

Abstract

Introduction

Intraoperative kinematic analysis using a navigation system in total knee arthroplasty (TKA) has been increasing. The purpose of the present study was to assess the reproducibility of the intraoperative kinematics analysis in TKA using the image-free knee navigation system.

Materials and methods

Fifty-one knees in 45 patients who received TKA, performed by a single surgeon (the senior consultant) with the resident, were included in this retrospective study. There were 7 men and 38 women and the mean age was 74.3 years. Cruciate retaining (CR) type and posterior stabilized (PS) type implants were inserted into 38 and 13 knees. The senior consultant and the resident analyzed initial kinematics, the axial rotation of the tibia and the coronal alignment of the lower limb, three times in each knee on manual passive knee flexion intraoperatively using the navigation system. Intra-class correlation coefficients (ICC) with 95 % confidence intervals were calculated to determine the reproducibility of this analysis.

Results

In regard to intra-rater reproducibility with axial rotation of the tibia, the ICC of the senior consultant was 0.965 for CR knees and 0.972 for PS knees while the ICC of the resident were 0.966 and 0.956. Inter-rater reproducibility was excellent for both knee types (ICC, 0.885 for CR knees and 0.864 for PS knees). In regard to intra-rater reproducibility with coronal alignment of the lower limb, ICC of the senior consultant was 0.990 for CR knees and 0.996 for PS knees while those of the resident were 0.990 and 0.995. Inter-rater reproducibility was also excellent for both knee types (ICC, 0.978 for CR knees and 0.994 for PS knees).

Conclusions

Manual intraoperative kinematic analysis using a navigation system in TKA showed excellent reproducibility. This result may encourage further studies about intraoperative kinematic analysis using a navigation system in TKA.
Literature
3.
go back to reference Singisetti K, Muthumayandi K, Abual-Rub Z, Weir D (2015) Navigation-assisted versus conventional total knee replacement: no difference in patient-reported outcome measures (PROMs) at 1 and 2 years. Arch Orthop Trauma Surg 135:1595–1601. doi:10.1007/s00402-015-2314-7 CrossRefPubMed Singisetti K, Muthumayandi K, Abual-Rub Z, Weir D (2015) Navigation-assisted versus conventional total knee replacement: no difference in patient-reported outcome measures (PROMs) at 1 and 2 years. Arch Orthop Trauma Surg 135:1595–1601. doi:10.​1007/​s00402-015-2314-7 CrossRefPubMed
8.
go back to reference Hanson GR, Suggs JF, Freiberg AA et al (2006) Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24:974–981. doi:10.1002/jor.20141 CrossRefPubMed Hanson GR, Suggs JF, Freiberg AA et al (2006) Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res 24:974–981. doi:10.​1002/​jor.​20141 CrossRefPubMed
9.
10.
11.
12.
go back to reference Casino D, Martelli S, Zaffagnini S et al (2009) Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation. J Orthop Res 27:202–207. doi:10.1002/jor.20746 CrossRefPubMed Casino D, Martelli S, Zaffagnini S et al (2009) Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation. J Orthop Res 27:202–207. doi:10.​1002/​jor.​20746 CrossRefPubMed
14.
go back to reference Akagi M, Mori S, Nishimura S et al (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRefPubMed Akagi M, Mori S, Nishimura S et al (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRefPubMed
15.
go back to reference Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRefPubMed Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRefPubMed
16.
17.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
18.
go back to reference Klein GR, Parvizi J, Rapuri VR et al (2004) The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty. J Arthroplasty 19:986–991. doi:10.1016/j.arth.2004.07.002 PubMed Klein GR, Parvizi J, Rapuri VR et al (2004) The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty. J Arthroplasty 19:986–991. doi:10.​1016/​j.​arth.​2004.​07.​002 PubMed
20.
go back to reference Ishida K, Shibanuma N, Matsumoto T et al (2015) Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty. Knee Surg, Sport Traumatol Arthrosc. doi:10.1007/s00167-015-3572-1 Ishida K, Shibanuma N, Matsumoto T et al (2015) Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty. Knee Surg, Sport Traumatol Arthrosc. doi:10.​1007/​s00167-015-3572-1
21.
go back to reference Matsuzaki T, Matsumoto T, Kubo S et al (2014) Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor. Knee Surg Sports Traumatol Arthrosc 22:615–620. doi:10.1007/s00167-013-2627-4 CrossRefPubMed Matsuzaki T, Matsumoto T, Kubo S et al (2014) Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor. Knee Surg Sports Traumatol Arthrosc 22:615–620. doi:10.​1007/​s00167-013-2627-4 CrossRefPubMed
24.
go back to reference Zaffagnini S, Bignozzi S, Martelli S et al (2006) New intraoperative protocol for kinematic evaluation of ACL reconstruction: preliminary results. Knee Surg, Sport Traumatol Arthrosc 14:811–816. doi:10.1007/s00167-006-0057-2 CrossRef Zaffagnini S, Bignozzi S, Martelli S et al (2006) New intraoperative protocol for kinematic evaluation of ACL reconstruction: preliminary results. Knee Surg, Sport Traumatol Arthrosc 14:811–816. doi:10.​1007/​s00167-006-0057-2 CrossRef
25.
go back to reference Hauschild O, Konstantinidis L, Strohm PC et al (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg, Sport Traumatol Arthrosc 17:1143–1151. doi:10.1007/s00167-009-0825-x CrossRef Hauschild O, Konstantinidis L, Strohm PC et al (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg, Sport Traumatol Arthrosc 17:1143–1151. doi:10.​1007/​s00167-009-0825-x CrossRef
Metadata
Title
Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
Authors
Keizo Wada
Hiroshi Mikami
Daisuke Hamada
Hiroshi Yonezu
Koichi Oba
Koichi Sairyo
Publication date
01-02-2016
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2016
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2402-8

Other articles of this Issue 2/2016

Archives of Orthopaedic and Trauma Surgery 2/2016 Go to the issue