Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 2/2015

Open Access 01-02-2015 | Orthopaedic Surgery

Reversed shoulder arthroplasty with inversed bearing materials: 2-year clinical and radiographic results in 101 patients

Authors: Ulrich Irlenbusch, Max J. Kääb, George Kohut, Jerome Proust, Falk Reuther, Thierry Joudet

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2015

Login to get access

Abstract

Introduction

This study documents 2-year clinical and radiographic results following reversed total shoulder arthroplasty using a novel prosthesis with inverted bearing materials (polyethylene glenoid; metal humeral component). This design was intended to avoid massive PE abrasion on the humeral side. Therefore, we predicted a lack of subsequent osteolysis-induced exacerbation of scapular notching, and because of other design features and modified operating technique a reduced notching rate.

Materials and methods

An ongoing, prospective, international, multicenter study of patients implanted with a novel prosthesis at six European centers. The current analysis presents 2-year follow-up data (patients operated between December 2007 and July 2009). Clinical evaluation tools comprised the Constant–Murley score (CS), the American Shoulder and Elbow Surgeon score, range of motion, and a visual analog scale to assess pain and satisfaction. Radiographs were evaluated for notching and radiolucent lines. Any complications were recorded.

Results

In total, 113 prostheses (113 patients) with a mean follow-up of 27.6 (±3.6) months were analyzed. CS increased from 22.5 (±13.7) to 65.3 (±14.9) points (p = 0.06). Inferior scapular notching (only grade 1 and 2) was identified in 20.5 % of patients, with no signs of PE-induced osteolysis. 4.4 % of patients experienced an implant-related complication.

Conclusions

Inversion of the materials led to another type of notching with no signs of PE-induced osteolysis and no increase in the risk of short-term complications. Clinical results were comparable with other prostheses. Mid- to long-term results are required before any firm conclusions on clinical outcome and survival can be drawn.
Literature
1.
go back to reference Nam D, Kepler CK, Neviaser AS, Jones KJ, Wright TM, Craig EV, Warren RF (2010) Reverse total shoulder arthroplasty: current concepts, results, and component wear analysis. J Bone Joint Surg Am 92(Suppl 2):23–35PubMedCrossRef Nam D, Kepler CK, Neviaser AS, Jones KJ, Wright TM, Craig EV, Warren RF (2010) Reverse total shoulder arthroplasty: current concepts, results, and component wear analysis. J Bone Joint Surg Am 92(Suppl 2):23–35PubMedCrossRef
2.
go back to reference Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D (2004) Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 86(3):388–395PubMedCrossRef Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D (2004) Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 86(3):388–395PubMedCrossRef
3.
go back to reference Nicholson GP, Strauss EJ, Sherman SL (2011) Scapular notching: recognition and strategies to minimize clinical impact. Clin Orthop Relat Res 469(9):2521–2530PubMedCentralPubMedCrossRef Nicholson GP, Strauss EJ, Sherman SL (2011) Scapular notching: recognition and strategies to minimize clinical impact. Clin Orthop Relat Res 469(9):2521–2530PubMedCentralPubMedCrossRef
4.
go back to reference Nyffeler RW, Werner CM, Simmen BR, Gerber C (2004) Analysis of a retrieved delta III total shoulder prosthesis. J Bone Joint Surg Br 86(8):1187–1191PubMedCrossRef Nyffeler RW, Werner CM, Simmen BR, Gerber C (2004) Analysis of a retrieved delta III total shoulder prosthesis. J Bone Joint Surg Br 86(8):1187–1191PubMedCrossRef
5.
go back to reference Boileau P, Watkinson D, Hatzidakis AM, Hovorka I (2006) Neer Award 2005: the Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty. J Shoulder Elb Surg 15(5):527–540CrossRef Boileau P, Watkinson D, Hatzidakis AM, Hovorka I (2006) Neer Award 2005: the Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty. J Shoulder Elb Surg 15(5):527–540CrossRef
6.
go back to reference Levigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, Walch G (2008) Scapular notching in reverse shoulder arthroplasty. J Shoulder Elb Surg 17(6):925–935CrossRef Levigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, Walch G (2008) Scapular notching in reverse shoulder arthroplasty. J Shoulder Elb Surg 17(6):925–935CrossRef
7.
go back to reference Cazeneuve JF, Cristofari DJ (2009) Delta III reverse shoulder arthroplasty: radiological outcome for acute complex fractures of the proximal humerus in elderly patients. Orthop Traumatol Surg Res 95(5):325–329PubMedCrossRef Cazeneuve JF, Cristofari DJ (2009) Delta III reverse shoulder arthroplasty: radiological outcome for acute complex fractures of the proximal humerus in elderly patients. Orthop Traumatol Surg Res 95(5):325–329PubMedCrossRef
8.
go back to reference Grassi FA, Murena L, Valli F, Alberio R (2009) Six-year experience with the Delta III reverse shoulder prosthesis. J Orthop Surg (Hong Kong) 17(2):151–156 Grassi FA, Murena L, Valli F, Alberio R (2009) Six-year experience with the Delta III reverse shoulder prosthesis. J Orthop Surg (Hong Kong) 17(2):151–156
10.
go back to reference Kohut G, Dallmann F, Irlenbusch U (2012) Wear-induced loss of mass in reversed total shoulder arthroplasty with conventional and inverted bearing materials. J Biomech 45(3):469–473PubMedCrossRef Kohut G, Dallmann F, Irlenbusch U (2012) Wear-induced loss of mass in reversed total shoulder arthroplasty with conventional and inverted bearing materials. J Biomech 45(3):469–473PubMedCrossRef
11.
go back to reference Nyffeler RW, Werner CM, Gerber C (2005) Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elb Surg 14(5):524–528CrossRef Nyffeler RW, Werner CM, Gerber C (2005) Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elb Surg 14(5):524–528CrossRef
12.
go back to reference Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C (2007) Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am 89(3):588–600PubMedCrossRef Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C (2007) Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am 89(3):588–600PubMedCrossRef
13.
go back to reference Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed
14.
go back to reference Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, Iannotti JP, Mow VC, Sidles JA, Zuckerman JD (1994) A standardized method for the assessment of shoulder function. J Shoulder Elb Surg 3(6):347–352CrossRef Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, Iannotti JP, Mow VC, Sidles JA, Zuckerman JD (1994) A standardized method for the assessment of shoulder function. J Shoulder Elb Surg 3(6):347–352CrossRef
15.
go back to reference Valenti P, Boutens D, Nerot C (2001) Delta 3 reversed prosthesis for ostreoarthritis with massive rotator cuff tear: long term results (>5 years). In: Walch G, Boileau P, Molé D (eds) Shoulder prosthesis. Sauramps Medical, Montpellier, pp 253–259 Valenti P, Boutens D, Nerot C (2001) Delta 3 reversed prosthesis for ostreoarthritis with massive rotator cuff tear: long term results (>5 years). In: Walch G, Boileau P, Molé D (eds) Shoulder prosthesis. Sauramps Medical, Montpellier, pp 253–259
16.
go back to reference Boileau P, Watkinson DJ, Hatzidakis AM, Balg F (2005) Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elb Surg 14(1 Suppl S):147S–161SCrossRef Boileau P, Watkinson DJ, Hatzidakis AM, Balg F (2005) Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elb Surg 14(1 Suppl S):147S–161SCrossRef
17.
go back to reference Stechel A, Fuhrmann U, Irlenbusch L, Rott O, Irlenbusch U (2010) Reversed shoulder arthroplasty in cuff tear arthritis, fracture sequelae, and revision arthroplasty. Acta Orthop 81(3):367–372PubMedCentralPubMedCrossRef Stechel A, Fuhrmann U, Irlenbusch L, Rott O, Irlenbusch U (2010) Reversed shoulder arthroplasty in cuff tear arthritis, fracture sequelae, and revision arthroplasty. Acta Orthop 81(3):367–372PubMedCentralPubMedCrossRef
18.
go back to reference Kepler CK, Nho SJ, Bansal M, Ala OL, Craig EV, Wright TM, Warren RF (2010) Radiographic and histopathologic analysis of osteolysis after total shoulder arthroplasty. J Shoulder Elb Surg 19(4):588–595CrossRef Kepler CK, Nho SJ, Bansal M, Ala OL, Craig EV, Wright TM, Warren RF (2010) Radiographic and histopathologic analysis of osteolysis after total shoulder arthroplasty. J Shoulder Elb Surg 19(4):588–595CrossRef
19.
go back to reference Gutierrez S, Comiskey CAT, Luo ZP, Pupello DR, Frankle MA (2008) Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors. J Bone Joint Surg Am 90(12):2606–2615PubMedCrossRef Gutierrez S, Comiskey CAT, Luo ZP, Pupello DR, Frankle MA (2008) Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors. J Bone Joint Surg Am 90(12):2606–2615PubMedCrossRef
20.
go back to reference Roche CP, Marczuk Y, Wright TW, Flurin PH, Grey S, Jones R, Routman HD, Gilot G, Zuckerman JD (2013) Scapular notching and osteophyte formation after reverse shoulder replacement: radiological analysis of implant position in male and female patients. Bone Joint J 95-b(4):530–535PubMedCrossRef Roche CP, Marczuk Y, Wright TW, Flurin PH, Grey S, Jones R, Routman HD, Gilot G, Zuckerman JD (2013) Scapular notching and osteophyte formation after reverse shoulder replacement: radiological analysis of implant position in male and female patients. Bone Joint J 95-b(4):530–535PubMedCrossRef
21.
go back to reference Valenti P, Sauzieres P, Katz D, Kalouche I, Kilinc AS (2011) Do less medialized reverse shoulder prostheses increase motion and reduce notching? Clin Orthop Relat Res 469(9):2550–2557PubMedCentralPubMedCrossRef Valenti P, Sauzieres P, Katz D, Kalouche I, Kilinc AS (2011) Do less medialized reverse shoulder prostheses increase motion and reduce notching? Clin Orthop Relat Res 469(9):2550–2557PubMedCentralPubMedCrossRef
22.
go back to reference Cuff D, Clark R, Pupello D, Frankle M (2012) Reverse shoulder arthroplasty for the treatment of rotator cuff deficiency: a concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 94(21):1996–2000PubMedCrossRef Cuff D, Clark R, Pupello D, Frankle M (2012) Reverse shoulder arthroplasty for the treatment of rotator cuff deficiency: a concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 94(21):1996–2000PubMedCrossRef
23.
go back to reference Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH (1992) Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res 285:13–29PubMed Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH (1992) Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res 285:13–29PubMed
24.
go back to reference Harman M, Frankle M, Vasey M, Banks S (2005) Initial glenoid component fixation in “reverse” total shoulder arthroplasty: a biomechanical evaluation. J Shoulder Elb Surg 14(1 Suppl S):162s–167sCrossRef Harman M, Frankle M, Vasey M, Banks S (2005) Initial glenoid component fixation in “reverse” total shoulder arthroplasty: a biomechanical evaluation. J Shoulder Elb Surg 14(1 Suppl S):162s–167sCrossRef
25.
go back to reference Hopkins AR, Hansen UN, Bull AM, Emery R, Amis AA (2008) Fixation of the reversed shoulder prosthesis. J Shoulder Elb Surg 17(6):974–980CrossRef Hopkins AR, Hansen UN, Bull AM, Emery R, Amis AA (2008) Fixation of the reversed shoulder prosthesis. J Shoulder Elb Surg 17(6):974–980CrossRef
26.
go back to reference Middernacht B, De Roo PJ, Van Maele G, De Wilde LF (2008) Consequences of scapular anatomy for reversed total shoulder arthroplasty. Clin Orthop Relat Res 466(6):1410–1418PubMedCentralPubMedCrossRef Middernacht B, De Roo PJ, Van Maele G, De Wilde LF (2008) Consequences of scapular anatomy for reversed total shoulder arthroplasty. Clin Orthop Relat Res 466(6):1410–1418PubMedCentralPubMedCrossRef
27.
go back to reference Chou J, Malak SF, Anderson IA, Astley T, Poon PC (2009) Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching. J Shoulder Elb Surg 18(3):354–359CrossRef Chou J, Malak SF, Anderson IA, Astley T, Poon PC (2009) Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching. J Shoulder Elb Surg 18(3):354–359CrossRef
28.
go back to reference Werner CM, Steinmann PA, Gilbart M, Gerber C (2005) Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am 87(7):1476–1486PubMedCrossRef Werner CM, Steinmann PA, Gilbart M, Gerber C (2005) Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am 87(7):1476–1486PubMedCrossRef
29.
go back to reference Roche C, Flurin PH, Wright T, Crosby LA, Mauldin M, Zuckerman JD (2009) An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. J Shoulder Elb Surg 18(5):734–741CrossRef Roche C, Flurin PH, Wright T, Crosby LA, Mauldin M, Zuckerman JD (2009) An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. J Shoulder Elb Surg 18(5):734–741CrossRef
30.
go back to reference Mizuno N, Denard PJ, Raiss P, Walch G (2012) The clinical and radiographical results of reverse total shoulder arthroplasty with eccentric glenosphere. Int Orthop 36(8):1647–1653PubMedCentralPubMedCrossRef Mizuno N, Denard PJ, Raiss P, Walch G (2012) The clinical and radiographical results of reverse total shoulder arthroplasty with eccentric glenosphere. Int Orthop 36(8):1647–1653PubMedCentralPubMedCrossRef
31.
go back to reference Nam D, Kepler CK, Nho SJ, Craig EV, Warren RF, Wright TM (2010) Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty. J Shoulder Elb Surg 19(7):1003–1012CrossRef Nam D, Kepler CK, Nho SJ, Craig EV, Warren RF, Wright TM (2010) Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty. J Shoulder Elb Surg 19(7):1003–1012CrossRef
32.
go back to reference Edwards TB, Trappey GJ, Riley C, O’Connor DP, Elkousy HA, Gartsman GM (2012) Inferior tilt of the glenoid component does not decrease scapular notching in reverse shoulder arthroplasty: results of a prospective randomized study. J Shoulder Elb Surg 21(5):641–646CrossRef Edwards TB, Trappey GJ, Riley C, O’Connor DP, Elkousy HA, Gartsman GM (2012) Inferior tilt of the glenoid component does not decrease scapular notching in reverse shoulder arthroplasty: results of a prospective randomized study. J Shoulder Elb Surg 21(5):641–646CrossRef
33.
go back to reference Clavert P, Deves O, Krier J, Mille P, Kahn JL, Kempf JF (2006) Étude du comportement des vis de la prothèse inversée lors de différentes mises en charge. Rev Chir Orthop 92(Suppl 6):3S146 Clavert P, Deves O, Krier J, Mille P, Kahn JL, Kempf JF (2006) Étude du comportement des vis de la prothèse inversée lors de différentes mises en charge. Rev Chir Orthop 92(Suppl 6):3S146
34.
go back to reference Day JS, MacDonald DW, Olsen M, Getz C, Williams GR, Kurtz SM (2012) Polyethylene wear in retrieved reverse total shoulder components. J Shoulder Elb Surg 21(5):667–674CrossRef Day JS, MacDonald DW, Olsen M, Getz C, Williams GR, Kurtz SM (2012) Polyethylene wear in retrieved reverse total shoulder components. J Shoulder Elb Surg 21(5):667–674CrossRef
Metadata
Title
Reversed shoulder arthroplasty with inversed bearing materials: 2-year clinical and radiographic results in 101 patients
Authors
Ulrich Irlenbusch
Max J. Kääb
George Kohut
Jerome Proust
Falk Reuther
Thierry Joudet
Publication date
01-02-2015
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2015
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-014-2135-0

Other articles of this Issue 2/2015

Archives of Orthopaedic and Trauma Surgery 2/2015 Go to the issue