Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 2/2010

01-02-2010 | Orthopaedic Surgery

Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2010

Login to get access

Abstract

Introduction

When highly conforming polyethylene inlays were introduced into total knee arthroplasty (TKA), they were characterized as adding anteroposterior stability to the reconstructed knee. The aim of this study was to examine the patellofemoral pressure with the designs of a highly conforming and a posterior stabilized inlay. The patellofemoral pressure depends among other factors on the anteroposterior stability of the knee joint.

Materials and methods

Eight fresh frozen human knee specimens underwent testing in a kinematic device. Knee motion was driven by a hydraulic cylinder at an extension moment of 31 Nm. The patellofemoral contact pressure was measured using a pressure sensitive film (Tekscan®, Inc., Boston, USA). First, this was assessed after implantation of a cruciate retaining (CR) TKA with a highly conforming polyethylene insert before and after resection of the posterior cruciate ligament. After that, the same measurements were performed with a similar posterior stabilized prosthesis.

Results

Patellofemoral contact pressures in the CR prosthesis using the highly conforming inlay were not significantly different before and after resection of the posterior cruciate ligament. However, after implantation of a posterior stabilized prosthesis peak pressure was significantly lower [Mean: 6.12, (SD 2.37) MPa] in comparison to the highly conforming type [7.12, (SD 2.53) MPa, P < 0.01] at a preserved posterior cruciate ligament. Further to that, the mean contact pressure turned out to be lower with the posterior stabilized design (P < 0.006).

Conclusion

The results of this study suggest that a posterior stabilized prosthesis design reduces the patellofemoral peak and mean pressure in comparison with a high conforming design. The better reproducible femoral rollback with a posterior stabilized model at a tibial ventral shift could serve as a possible explanation.
Literature
1.
go back to reference Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRefPubMed Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRefPubMed
2.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13CrossRefPubMed Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13CrossRefPubMed
3.
go back to reference Hsieh HH, Walker PS (1976) Stabilizing mechanisms of the loaded and unloaded knee joint. J Bone Joint Surg Am 58(1):87–93PubMed Hsieh HH, Walker PS (1976) Stabilizing mechanisms of the loaded and unloaded knee joint. J Bone Joint Surg Am 58(1):87–93PubMed
4.
go back to reference Scott RD, Thornhill TS (1994) Posterior cruciate supplementing total knee replacement using conforming inserts and cruciate recession. Effect on range of motion and radiolucent lines. Clin Orthop Relat Res 309:146–149PubMed Scott RD, Thornhill TS (1994) Posterior cruciate supplementing total knee replacement using conforming inserts and cruciate recession. Effect on range of motion and radiolucent lines. Clin Orthop Relat Res 309:146–149PubMed
5.
go back to reference Stukenborg-Colsman C, Ostermeier S, Hurschler C, Wirth CJ (2002) Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs. Acta Orthop Scand 73(6):638–646CrossRefPubMed Stukenborg-Colsman C, Ostermeier S, Hurschler C, Wirth CJ (2002) Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs. Acta Orthop Scand 73(6):638–646CrossRefPubMed
6.
go back to reference Stukenborg-Colsman C, Ostermeier S, Wenger KH, Wirth CJ (2002) Relative motion of a mobile bearing inlay after total knee arthroplasty–dynamic in vitro study. Clin Biomech (Bristol, Avon) 17(1):49–55CrossRef Stukenborg-Colsman C, Ostermeier S, Wenger KH, Wirth CJ (2002) Relative motion of a mobile bearing inlay after total knee arthroplasty–dynamic in vitro study. Clin Biomech (Bristol, Avon) 17(1):49–55CrossRef
7.
go back to reference Matsuda S, Ishinishi T, White SE, Whiteside LA (1997) Patellofemoral joint after total knee arthroplasty. Effect on contact area and contact stress. J Arthroplasty 12(7):790–797CrossRefPubMed Matsuda S, Ishinishi T, White SE, Whiteside LA (1997) Patellofemoral joint after total knee arthroplasty. Effect on contact area and contact stress. J Arthroplasty 12(7):790–797CrossRefPubMed
8.
go back to reference Bohnsack M, Klages P, Hurschler C, Halcour A, Wilharm A, Ostermeier S, Ruhmann O, Wirth CJ (2006) Influence of an infrapatellar fat pad edema on patellofemoral biomechanics and knee kinematics: a possible relation to the anterior knee pain syndrome. Arch Orthop Trauma Surg 13 Bohnsack M, Klages P, Hurschler C, Halcour A, Wilharm A, Ostermeier S, Ruhmann O, Wirth CJ (2006) Influence of an infrapatellar fat pad edema on patellofemoral biomechanics and knee kinematics: a possible relation to the anterior knee pain syndrome. Arch Orthop Trauma Surg 13
9.
go back to reference Huberti HH, Hayes WC, Stone JL, Shybut GT (1984) Force ratios in the quadriceps tendon and ligamentum patellae. J Orthop Res 2(1):49–54CrossRefPubMed Huberti HH, Hayes WC, Stone JL, Shybut GT (1984) Force ratios in the quadriceps tendon and ligamentum patellae. J Orthop Res 2(1):49–54CrossRefPubMed
10.
go back to reference Kaufer H (1971) Mechanical function of the patella. J Bone Joint Surg Am 53(8):1551–1560PubMed Kaufer H (1971) Mechanical function of the patella. J Bone Joint Surg Am 53(8):1551–1560PubMed
11.
go back to reference Ostermeier S, Hurschler C, Stukenborg-Colsman C (2004) Quadriceps function after TKA—an in vitro study in a knee kinematic simulator. Clin Biomech (Bristol, Avon) 19(3):270–276CrossRef Ostermeier S, Hurschler C, Stukenborg-Colsman C (2004) Quadriceps function after TKA—an in vitro study in a knee kinematic simulator. Clin Biomech (Bristol, Avon) 19(3):270–276CrossRef
12.
go back to reference Ostermeier S, Hurschler C, Windhagen H, Stukenborg-Colsman C (2006) In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 14(10):934–939CrossRefPubMed Ostermeier S, Hurschler C, Windhagen H, Stukenborg-Colsman C (2006) In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 14(10):934–939CrossRefPubMed
13.
go back to reference Rand JA (1994) The patellofemoral joint in total knee arthroplasty. J Bone Joint Surg Am 76(4):612–620PubMed Rand JA (1994) The patellofemoral joint in total knee arthroplasty. J Bone Joint Surg Am 76(4):612–620PubMed
14.
go back to reference Lynch AF, Rorabeck CH, Bourne RB (1987) Extensor mechanism complications following total knee arthroplasty. J Arthroplasty 2(2):135–140CrossRefPubMed Lynch AF, Rorabeck CH, Bourne RB (1987) Extensor mechanism complications following total knee arthroplasty. J Arthroplasty 2(2):135–140CrossRefPubMed
15.
go back to reference Boyd AD Jr, Ewald FC, Thomas WH, Poss R, Sledge CB (1993) Long-term complications after total knee arthroplasty with or without resurfacing of the patella. J Bone Joint Surg Am 75(5):674–681PubMed Boyd AD Jr, Ewald FC, Thomas WH, Poss R, Sledge CB (1993) Long-term complications after total knee arthroplasty with or without resurfacing of the patella. J Bone Joint Surg Am 75(5):674–681PubMed
16.
go back to reference Stukenborg-Colsman C, Ostermeier S, Burmester O, Wirth CJ (2003) Dynamic in vitro measurement of retropatellar pressure after knee arthroplasty. Orthopade 32(4):319–322CrossRefPubMed Stukenborg-Colsman C, Ostermeier S, Burmester O, Wirth CJ (2003) Dynamic in vitro measurement of retropatellar pressure after knee arthroplasty. Orthopade 32(4):319–322CrossRefPubMed
17.
go back to reference Fuchs S, Skwara A, Tibesku CO, Rosenbaum D (2005) Retropatellar contact characteristics before and after total knee arthroplasty. Knee 12(1):9–12CrossRefPubMed Fuchs S, Skwara A, Tibesku CO, Rosenbaum D (2005) Retropatellar contact characteristics before and after total knee arthroplasty. Knee 12(1):9–12CrossRefPubMed
18.
go back to reference Wendt PP, Johnson RP (1985) A study of quadriceps excursion, torque, and the effect of patellectomy on cadaver knees. J Bone Joint Surg Am 67(5):726–732PubMed Wendt PP, Johnson RP (1985) A study of quadriceps excursion, torque, and the effect of patellectomy on cadaver knees. J Bone Joint Surg Am 67(5):726–732PubMed
19.
go back to reference Insall JN, Lachiewicz PF, Burstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. J Bone Joint Surg Am 64(9):1317–1323PubMed Insall JN, Lachiewicz PF, Burstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. J Bone Joint Surg Am 64(9):1317–1323PubMed
Metadata
Title
Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays
Publication date
01-02-2010
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2010
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0920-y

Other articles of this Issue 2/2010

Archives of Orthopaedic and Trauma Surgery 2/2010 Go to the issue

Orthopaedic Surgery

Total femur replacement